• Title/Summary/Keyword: Power Distribution Systems

Search Result 1,306, Processing Time 0.023 seconds

Power Transmission Optimization Based on the Driving Gear of a Cross Drilling/Milling Unit using a Micro Geometry Method (마이크로 지오메트리 방법을 이용한 크로스 드릴링/밀링 유닛 구동기어의 동력전달 최적화에 관한 연구)

  • Kim, Dong-Seon;Zhen, Qin;Beak, Gwon-In;Wu, Yu-Ting;Jeon, Nam-Sul;Lyu, Sung Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.4
    • /
    • pp.93-99
    • /
    • 2019
  • A cross drilling/milling Unit is an important mechanical part which is widely used in many kinds of machining tool, and various gear trains with good accuracy and reliability features are widely used in power transmission systems. A study on a novel power transmission optimization method for driving gear trains in cross drilling/milling units is presented in this paper. A commercial program for gear system simulation, Romax Designer, was used in this research to intuitively observe the gear meshing and the load distribution conditions on the gear teeth. We obtained the optimal modification value through comparing the results of repeated experiments. For validation, optimized gears were fabricated and then measured with a precision tester.

Resource Allocation for Heterogeneous Service in Green Mobile Edge Networks Using Deep Reinforcement Learning

  • Sun, Si-yuan;Zheng, Ying;Zhou, Jun-hua;Weng, Jiu-xing;Wei, Yi-fei;Wang, Xiao-jun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.7
    • /
    • pp.2496-2512
    • /
    • 2021
  • The requirements for powerful computing capability, high capacity, low latency and low energy consumption of emerging services, pose severe challenges to the fifth-generation (5G) network. As a promising paradigm, mobile edge networks can provide services in proximity to users by deploying computing components and cache at the edge, which can effectively decrease service delay. However, the coexistence of heterogeneous services and the sharing of limited resources lead to the competition between various services for multiple resources. This paper considers two typical heterogeneous services: computing services and content delivery services, in order to properly configure resources, it is crucial to develop an effective offloading and caching strategies. Considering the high energy consumption of 5G base stations, this paper considers the hybrid energy supply model of traditional power grid and green energy. Therefore, it is necessary to design a reasonable association mechanism which can allocate more service load to base stations rich in green energy to improve the utilization of green energy. This paper formed the joint optimization problem of computing offloading, caching and resource allocation for heterogeneous services with the objective of minimizing the on-grid power consumption under the constraints of limited resources and QoS guarantee. Since the joint optimization problem is a mixed integer nonlinear programming problem that is impossible to solve, this paper uses deep reinforcement learning method to learn the optimal strategy through a lot of training. Extensive simulation experiments show that compared with other schemes, the proposed scheme can allocate resources to heterogeneous service according to the green energy distribution which can effectively reduce the traditional energy consumption.

A Study on the Deterioration Process of 22kV Power Cables in Operation (운전 중인 상태에 있는 22kV 전송선로 케이블의 열화 과정해석에 대한 연구)

  • Lee, Kwan-Woo;Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.3
    • /
    • pp.127-133
    • /
    • 2013
  • As an essential part of current industrial society, electric power energy is contantaly increasing in pace with the development of science and technology. In order to meet the demand of electric power, power facilities which take care of the higher voltage and bigger capacity is required. To produce and supply electric power on a sound basis the electric facilities should operate with reliability. To prevent disasters in advance, the high quality facilities should be manufactured, and a constant management should be done. When the power facilities cause accidents, the result is huge national deficits. Since the power facilities play a pivotal role in the key industry of national infrastructures of they should operate for a long time in maintaining a stable state, and the accidents can be prevented in advance. The lifetime of a power cable is considered to be 30 years at the time of manufacture, but in real fields, accidents of cable occur 8-12 years from the start of operation, resulting in a heavy loss of properties. In this paper, we will show that we have found out the cause and process of the deterioration of 22kV cable systems in operation. The result is that the process of deterioration does not follow the Weibull distribution only ; but rather, after the heat deterioration the Weibull distributed deterioration comes, then the cable is destroyed due to the partial discharge resulting from the Weibull distributed deterioration.

A Study on the Optimization of Heat Flux in Engine Room of Auxiliary Power Unit for Self-Propelled Artillery (자주포용 보조동력장치 엔진룸의 열유동 최적화에 관한 연구)

  • Noh, Sang Wan;Park, Young Min;Kim, Sung Hoon;Lee, Jae Dong;Kim, Byung Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.629-635
    • /
    • 2019
  • In this study, we analyzed the effect of FAN and oil cooler application on APU. MIL-STD-810 was applied to the atmospheric environment and radiation dose in order to perform thermal flow analysis. The heat flow was analyzed for the case in which the inlet / outlet fan was applied (Case 1), the case in which the inlet fan and the oil cooler were applied (Case 2), and the case in which the inlet / outlet fan and the oil cooler were applied (Case 3). As a result, it was confirmed that the cylinder head temperature of Case 3 was 21.4 times lower than that of Case 1 and 8.0 times lower than that of Case 2. Experiments were conducted under the same ambient conditions in order to examine the validity of the results. The numerical values and experimental results showed a difference of less than 7%. Through this, we were able to confirm that the APU heat flow optimization model satisfies the design conditions. The results of this study are expected to be used as basic data for optimizing heat flow of APU.

Numerical simulation of three-dimensional flow and heat transfer characteristics of liquid lead-bismuth

  • He, Shaopeng;Wang, Mingjun;Zhang, Jing;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.6
    • /
    • pp.1834-1845
    • /
    • 2021
  • Liquid lead-bismuth cooled fast reactor is one of the most promising reactor types among the fourth-generation nuclear energy systems. The flow and heat transfer characteristics of lead-bismuth eutectic (LBE) are completely different from ordinary fluids due to its special thermal properties, causing that the traditional Reynolds analogy is no longer recommended and appropriate. More accurate turbulence flow and heat transfer model for the liquid metal lead-bismuth should be developed and applied in CFD simulation. In this paper, a specific CFD solver for simulating the flow and heat transfer of liquid lead-bismuth based on the k - 𝜀 - k𝜃 - 𝜀𝜃 model was developed based on the open source platform OpenFOAM. Then the advantage of proposed model was demonstrated and validated against a set of experimental data. Finally, the simulation of LBE turbulent flow and heat transfer in a 7-pin wire-wrapped rod bundle with the k - 𝜀 - k𝜃 - 𝜀𝜃 model was carried out. The influence of wire on the flow and heat transfer characteristics and the three-dimensional distribution of key thermal hydraulic parameters such as temperature, cross-flow velocity and Nusselt number were studied and presented. Compared with the traditional SED model with a constant Prt = 1.5 or 2.0, the k - 𝜀 - k𝜃 - 𝜀𝜃 model is more accurate on predicting the turbulence flow and heat transfer of liquid lead-bismuth. The average relative error of the k - 𝜀 - k𝜃 - 𝜀𝜃 model is reduced by 11.1% at most under the simulation conditions in this paper. This work is meaningful for the thermal hydraulic analysis and structure design of fuel assembly in the liquid lead-bismuth cooled fast reactor.

The Characteristics Study of Vehicle Evaporative Emission and Performance according to the Bio-Fuel Application (바이오 연료 적용에 따른 차량 증발가스 및 성능특성 연구)

  • Noh, Kyeong-Ha;Lee, Min-Ho;Kim, Ki-Ho;Kim, Sin;Park, Cheon-Kyu
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.874-882
    • /
    • 2017
  • As the interest on the air-pollution is gradually rising up at home and abroad, automotiv e and fuel researchers have been working on the exhaust emission reduction from vehicles through a lot of approaches, which consist of new engine design, innovative after-treatment systems, using clean (eco-friendly alternative) fuels and fuel quality improvement. This research has brought forward three main issues : evaporative, performance, air pollution. In addition, researcher studied the environment problems of the bio-ethanol, bio-butanol, bio-ETBE (Ethyl Tertiary Butyl Ether), MTBE (Methyl Tert iary Butyl Ether) fuel contained in the fuel as octane number improver. The researchers have many dat a about the health effects of ingestion of octane number improver. However, the data support the con clusion that octane number improver is a potential human carcinogen at high doses. Based on the bio-fuel and octane number improver types (bio-ethanol, bio-butanol, bio-ETBE, MTBE), this paper dis cussed the influence of gasoline fuel properties on the evaporative emission characteristics. Also, this p aper assessed the acceleration and power performance of gasoline vehicle for the bio-fuel property. As a result of the experiment, it was found that all the test fuels meet the domestic exhaust gas standards, and as a result of measurement of the vapor pressure of the test fuels, the bio - ethanol : 15 kPa and the biobutanol : 1.6 kPa. thus when manufacturing E3 fuel, Increasing the biobutanol content reduces evaporation gas and vapor pressure. In addition, Similar accelerating and powering performance was shown for the type of biofuel and when bio-butanol and bio-ethanol were compared accelerated perf ormance was improved by about 3.9% and vehicle power by 0.8%.

A Study on Improving Scheme and An Investigation into the Actual Condition about Components of Physical Distribution System (물류시스템 구성요인에 관한 실태분석과 개선방안에 관한 연구)

  • Kim, Kyeong-Cho
    • Journal of Distribution Science
    • /
    • v.7 no.4
    • /
    • pp.47-56
    • /
    • 2009
  • The purpose of this study is to present an alternative improving the efficient and reasonable of the physical distribution system management is influenced by many factors. Therefore, the study depends on the documentary method and survey method to achieve the purpose of this study. The major components of a physical distribution system are refers to as elements, include warehouse·storage system, transportation system, inventory system, physical distribution information system. The factors used in this study are ① factor of product(quality·A/S·added value of product·adaption of product·technical competitive power to other enterprises), ② factor of market(market channel·kinds of customer·physical distribution share), ③ factor of warehouse·storage(warehouse design·size·direction·storage ability·warehouse quality), ④ factor of transportation(promptness·reliability·responsibility·kinds of transportation·cooperation united transportation system·national transportation network), ⑤ factor of packaging (packaging design·material·educating program·pollution degree measure program), ⑥ factor of inventory(ordinary inventory criterion·consistence for inventories record), ⑦ factor of unloaded(unloaded machine·having machine ratio), ⑧ factor of information system (physical distribution quantity analysis·usable computer part), ⑨ factor of physical distribution cost(sales ratio to product) ⑩ factor of physical distribution system(physical distribution center etc). The implication of this study can be summarized as follows: ① In firms that have not adopted a systems integrative approach, physical distribution is a fragmented and often uncoordinated set of activities spread throughout various functions with function having its own set of priorities and measurements. ② The physical distribution is recognized as more an important strategic factor than a simple cost reduction factor, ③ It can be used a strategic competition tool to enterprise.

  • PDF

Sediment monitoring for hydro-abrasive erosion: A field study from Himalayas, India

  • Rai, Anant Kr.;Kumar, Arun
    • International Journal of Fluid Machinery and Systems
    • /
    • v.10 no.2
    • /
    • pp.146-153
    • /
    • 2017
  • Sediment flow through hydropower components causes hydro-abrasive erosion resulting in loss of efficiency, interruptions in power production and downtime for repair/maintenance. Online instruments are required to measure/capture the variations in sediment parameters along with collecting samples manually to analyse in laboratory for verification. In this paper, various sediment parameters viz. size, concentration (TSS), shape and mineral composition relevant to hydro-abrasive erosion were measured and discussed with respect to a hydropower plant in Himalayan region, India. A multi-frequency acoustic instrument was installed at a desilting chamber to continuously monitor particle size distribution (PSD) and TSS entering the turbine during 27 May to 6 August 2015. The sediment parameters viz. TSS, size distribution, mineral composition and shape entering the turbine were also measured and analysed, using manual samples collected twice daily from hydropower plant, in laboratory with instruments based on laser diffraction, dynamic digital image processing, gravimetric method, conductivity, scanning electron microscope, X-ray diffraction and turbidity. The acoustic instrument was able to capture the variation in TSS; however, significant deviations were found between measured mean sediment sizes compared to values found in the laboratory. A good relation was found for turbidity ($R^2=0.86$) and laser diffraction ($R^2=0.93$) with TSS, which indicated that turbidimeter and laser diffraction instrument can be used for continuous monitoring of TSS at the plant. Total sediment load passed through penstock during study period was estimated to be 15,500 ton. This study shall be useful for researchers and hydropower managers in measuring/monitoring sediment for hydro-abrasive erosion study in hydropower plants.

An Integrated Model of Static and Dynamic Measurement for Seat Discomfort

  • Daruis, Dian Darina Indah;Deros, Baba Md;Nor, Mohd Jailani Mohd;Hosseini, Mohammad
    • Industrial Engineering and Management Systems
    • /
    • v.10 no.3
    • /
    • pp.185-190
    • /
    • 2011
  • A driver interacts directly with the car seat at all times. There are ergonomic characteristics that have to be followed to produce comfortable seats. However, most of previous researches focused on either static or dynamic condition only. In addition, research on car seat development is critically lacking although Malaysia herself manufactures its own car. Hence, this paper integrates objective measurements and subjective evaluation to predict seat discomfort. The objective measurements consider both static and dynamic conditions. Steven's psychophysics power law has been used in which after expansion; ${\psi}\;=\;a+b{\varphi}_s^{\alpha}+c{\varphi}_v^{\beta}$ where ${\psi}$ is discomfort sensation, ${\varphi}_s^{\alpha}$ is static modality with exponent ${\alpha}$ and ${\varphi}_v^{\beta}$ is dynamic modality with exponent ${\beta}$. The subjects in this study were local and the cars used were Malaysian made compact car. Static objective measurement was the seat pressure distribution measurement. The experiment was carried out on the driver's seat in a real car with the engine turned off. Meanwhile, the dynamic objective measurement was carried out in a moving car on real roads. During pressure distribution and vibration transmissibility experiments, subjects were requested to evaluate their discomfort levels using vehicle seat discomfort survey questionnaire together with body map diagram. From subjective evaluations, seat pressure and vibration dose values exponent for static modality ${\alpha}$ = 1.51 and exponent for dynamic modality ${\beta}$ = 1.24 were produced. The curves produced from the $E_{q.s}$ showed better $R_{-sq}$ values (99%) when both static and dynamic modalities were considered together as compared to Eq. with single modality only (static or dynamic only R-Sq = 95%). In conclusion, car seat discomfort prediction gives better result when seat development considered both static and dynamic modalities; and using ergonomic approach.

A Comparative Study on Daylighting Performance Prediction of Light Tube and Dish Concentrator (광튜브와 디쉬형 집광기의 자연채광 성능 예측 및 비교 연구)

  • Oh, Seung Jin;Han, Hyun Joo;Chun, Wongee
    • Journal of Energy Engineering
    • /
    • v.21 no.2
    • /
    • pp.124-132
    • /
    • 2012
  • This study presents the simulation results of Photopia when a lecture room with north-facing windows were illuminated by two different types of daylighting systems to improve the imbalance in its lighting conditions. Especially, the candela power distribution curves (CDCs) on a clear sunny day at the summer solstice, reaching $80^{\circ}$ in solar altitude, were analyzed with respect to the illuminance available at task areas (work planes). The difference between its illuminance on the north and south areas exceeded 1,000 lux without any daylighting system. This, however, decreased drastically with the application of a daylighting system. When a light tube system was introduced, it reduced from 906lx to 603lx and, even further to 308lx with the application of a dish concentrator system. Generally, the performance of a light tube system was greatly influenced by solar altitude while its effect on the dish concentrator system was rather negligible.