• Title/Summary/Keyword: Power Distance

Search Result 2,402, Processing Time 0.03 seconds

A Study on the Analysis of Correlation Decay Distance(CoDecDist) Model for Enhancing Spatial Prediction Outputs of Spatially Distributed Wind Farms (풍력발전출력의 공간예측 향상을 위한 상관관계감소거리(CoDecDist) 모형 분석에 관한 연구)

  • Hur, Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.7
    • /
    • pp.80-86
    • /
    • 2015
  • As wind farm outputs depend on natural wind resources that vary over space and time, spatial correlation analysis is needed to estimate power outputs of wind generation resources. As a result, geographic information such as latitude and longitude plays a key role to estimate power outputs of spatially distributed wind farms. In this paper, we introduce spatial correlation analysis to estimate the power outputs produced by wind farms that are geographically distributed. We present spatial correlation analysis of empirical power output data for the JEJU Island and ERCOT ISO (Texas) wind farms and propose the Correlation Decay Distance (CoDecDist) model based on geographic correlation analysis to enhance the estimation of wind power outputs.

A Study on the Separation Distance to Protection of Buried Pipeline from Arc Strikes Caused by Power Line Ground Fault Current (지락사고시 지중금속배관에 대한 아크이격거리에 관한 연구)

  • Ha, Tae-Hyun;Bae, Jeong-Hyo;Lee, Hyun-Goo;Kim, Dae-Kyeong;Kim, Suk-Won
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.154-155
    • /
    • 2002
  • The demand of the power and gas energy have been rapidly increasing with the industralization, therefore, the area where buried pipelines run parallel with the adjacent power lines and cross them increases in Seoul as well as other cities. These situation cause AC interference from the power lines. However, there aren't any standards to preserve the pipelines from AC interference in Korea. This study introduces the separation distance to protection of buried pipeline from arc strikes caused by power line ground fault current. And this study examines and compares the arc distance through case study.

  • PDF

New Experimental Investigation of Magnetic and Electric Fields in the Vicinity of High-Voltage Power Lines

  • Ghnimi, Said;Rajhi, Adnen;Gharsallah, Ali
    • Journal of Magnetics
    • /
    • v.21 no.1
    • /
    • pp.102-109
    • /
    • 2016
  • In this paper, the theoretical and experimental characteristics of magnetic and electric fields in the vicinity of high voltage lines are investigated. To realize these measurements and calculations, we have developed some equations for two overhead power line configurations of 150 kV (single circuit, double circuit), based on Biot-savart law, image and Maxwell theories, in order to calculate the magnetic and electric fields. The measurements were done to a maximum distance from the tower of 50 m, at a height of 1m from the ground. These experiments take into consideration the real situations of the power lines and associated equipment. The experimental results obtained are near to that of the Biot-Savart theoretical results for a far distance from the tower; and for a distance close to the power line, the results from the image theory are in good agreement with the experimental results.

Development of An Expert System to Decide the Resetting Area of Protective Distance Relay in Power Transmission Systems (송전계통 보호 거리계전기 재정정 영역 판정 전문가시스템 개발)

  • 최면송;민병운;김기화;현승호;이승재
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.8
    • /
    • pp.437-443
    • /
    • 2003
  • In this paper an expert system is developed to decide the resetting area of protective devices in power transmission systems. A configuration change in power transmission networks from a substation extension such as new line or bus addition need resetting of protective devices around the point of configuration changes. To find the resetting area in complex power system is very difficult, especially when the distance protective relays are considered to be reset. The proposed expert system, in this paper to find the resetting area has many rules based on the changes of fault currents and apparent factors from the power system alteration. It solves the problem to find relay resetting area using the network information in the database and the rule-base. The case study shows a result of the problem to find relay resetting area in KEPCO system when there is any configuration change.

Analysis of Laser-protection Performance of Asymmetric-phase-mask Wavefront-coding Imaging Systems

  • Yangliang, Li;Qing, Ye;Lei, Wang;Hao, Zhang;Yunlong, Wu;Xian'an, Dou;Xiaoquan, Sun
    • Current Optics and Photonics
    • /
    • v.7 no.1
    • /
    • pp.1-14
    • /
    • 2023
  • Wavefront-coding imaging can achieve high-quality imaging along with a wide range of defocus. In this paper, the anti-laser detection and damage performance of wavefront-coding imaging systems using different asymmetric phase masks are studied, through modeling and simulation. Based on FresnelKirchhoff diffraction theory, the laser-propagation model of the wavefront-coding imaging system is established. The model uses defocus distance rather than wave aberration to characterize the degree of defocus of an imaging system. Then, based on a given defocus range, an optimization method based on Fisher information is used to determine the optimal phase-mask parameters. Finally, the anti-laser detection and damage performance of asymmetric phase masks at different defocus distances and propagation distances are simulated and analyzed. When studying the influence of defocus distance, compared to conventional imaging, the maximum single-pixel receiving power and echo-detection receiving power of asymmetric phase masks are reduced by about one and two orders of magnitude respectively. When exploring the influence of propagation distance, the maximum single-pixel receiving power of asymmetric phase masks decreases by about one order of magnitude and remains stable, and the echodetection receiving power gradually decreases with increasing propagation distance, until it approaches zero.

Analysis on the Effects of the Induced Noise with Change of the Separation Distance between Grounding Equipment at End of Telecommunication Line and the Inducting Facilities in Power Inducting Situation (전력 유도 장애 시 통신 선로 케이블의 접지체와 유도원간의 이격거리에 의한 유도 잡음 영향 분석)

  • Choi, Mun-Hwan;Lee, Sang-Mu;Cho, Pyoung-Dong
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.215-218
    • /
    • 2007
  • In this paper, we have analyzed the effects from the change of separation distance between grounding equipment at end of telecommunication line and the inducting facilities in power inducting situation. In the result of measurement, we can see that as the separation distance between grounding equipment ant end of telecommunication line and the inducting facility become longer, the induced noise level and PIF level is decreased. From the another experiment results about the effect of changing the impedance size in both ends of telecommunication line, however, we already knew that as the ground impedance at either end of the telecommunication line become grower, the noise level is increased, and as the ground impedance at either end of the telecommunication line become smaller, the noise level is decreased. Hence we can not define the relationship exactly between separation distance from inducting facility to inducted facility and the induced noise level because when the grounding equipment is moved, its impedance size is changed too. In conclusion, changing the separation distance between grounding equipment at end of telecommunication line and the inducting facilities have not influence on the induced noise level.

  • PDF

Implementation of Power Control System for a Long Distance Transmission in Wireless Mesh Network (무선 메쉬 네트워크에서 장거리 전송을 위한 전력제어 시스템 구현)

  • Park, Tae-Jin;Park, Man-Gon
    • Journal of Korea Multimedia Society
    • /
    • v.10 no.4
    • /
    • pp.516-526
    • /
    • 2007
  • Wireless mesh network is not only WLAN technology but it says core technology for implementation of ubiquitous network and we have to application on a various field through connection with the sensor network. However, there are limited to 100mW in the maximum power because WLAN is used into transmission frequency band to ISM band. The mesh network based on WLAN is essential study for a long distance transmission in the limited maximum power that it is doing to cost-efficient network of backbone. Therefore, in this paper, we have presented an conquerable method to limitation of reaching distance of wireless mesh network and made several experiments to presentation the proposed method. The results show that it is possible to rise a long distance transmission and power efficiency into application of various antenna and function definition and implementation of device driver.

  • PDF

Estimate of Flashover Position from E-field Calculation along Electrode Gap Distance (진공인터럽터 극간 랩거리 조정에 따른 각 부위의 전계값 계산을 통한 진공인터럽터 내부 절연파괴부위 예측)

  • Yoon, Jae-Hun;Lim, Kee-Jo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.23-23
    • /
    • 2010
  • Because of power consumption increase, global warming, and limitation of installation, not only high reliability and interruption capability but also compact and light power apparatuses are needed. In this paper, various models that short and long gap distance were used to analyze E field of each model. Calculation value was estimated of flashover position. As a result, short and long gap distance that vacuum interrupter inner between move electrode and fix electrode not coincided flashover position of each model. short gap distance estimated flashover position at electrode edge. but long gap distance model confirmed $E_{max}$ value at center shield. in this paper was compared electric field value. and estimated of flashover position from electric field calculation.

  • PDF

Distance Measurement by Automatic Peak Detection for Indoor Positioning Using Spread Spectrum Ultrasonic Waves

  • Suzuki, Akimasa;Miyara, Yasuaki;Iyota, Taketoshi;Kim, Young-Bok;Choi, Yong-Woon
    • Journal of Power System Engineering
    • /
    • v.19 no.2
    • /
    • pp.33-39
    • /
    • 2015
  • In conducting indoor positioning by code division multiple access using spread spectrum ultrasonic waves, it is required to detect signals under the influence of near-far problem occurred by difference on signal power, caused by distance between transmitter and receiver. For discussing robustness to the problem, we verified measuring accuracy on distance from an experiment on a real space with a hardware device where our proposed method is mounted. The proposed method performs automatic signal detection by setting threshold level dynamically. As an experimental result, measurable distance were improved by the proposed method, and measurement errors were up to 50mm in distances from 1000mm to 6000mm; therefore, enough accuracy to realize self-localization or navigation for autonomous mobile robot or human was obtained.

A Study of Distance Relay Characteristic of Transmission Line including FACTS Devices (FACTS 기기가 설치된 송전선로에서 거리계전기의 응동특성)

  • Jung, Chang-Ho;Suh, Jung-Nam;Bang, Seong-Won;Kim, Jin-O
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.31-33
    • /
    • 2000
  • This paper discusses the operational characteristic analysis of distance relay depending on the power system parameters in transmission line including FACTS devices. Distance relay requires protective coordination because the FACTS devices change power system parameters to increase power transmission capacity. In this paper, the dynamic operational characteristics of distance relay are analyed for the effect of fault resistance and operation mode of FACTS devices according to the installed points of these devices.

  • PDF