• Title/Summary/Keyword: Power Detector

Search Result 748, Processing Time 0.033 seconds

Design and Implementation of L/Ku-band Broadband Power Detector using Schottky Diode (Schottky 다이오드를 이용한 Six-port용 L/Ku-band 광대역 Power detector 설계 제작)

  • Kim Young-Wan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.615-618
    • /
    • 2006
  • The broadband power detector for direct- onversion Six-port output circuit was designed and implementaed in this paper. The power detector should linearly operated to produce the linear amplitude and phase signal fer input RF signal in required broadband. So, the power detector should be designed under conditions of matching circuit with low VSWR. The designed power detectors, which were implemented in L-band with 50 ohm matching and Ku-band with matching circuit and isolator, respectively, were evaluated in the performances.

  • PDF

Design and Implementation of Broadband Power Detector for Six-port Direct Conversion Receiver (Six-port 직접 변환 수신을 위한 광대역 Power detector 설계 제작)

  • Lee, Yong-Ju;Kim, Yeong-Wan;Park, Dong-Cheol
    • Journal of Satellite, Information and Communications
    • /
    • v.1 no.1
    • /
    • pp.59-64
    • /
    • 2006
  • The broadband power detector for power amplitude envelope detection of the direct-conversion Six-port output signal was designed and implemented in this paper. The power detector should be linearly operated to produce the linear amplitude and phase signal for input RF signals in required broadband frequency range. The power detector should be designed under conditions of matching circuit with low VSWR, which protect unbalanced phase signal from reflection signal due to mismatch between the output port of a six-port and the input port of a power detector. The designed power detectors, which were implemented in L-band with 50 ohm matching and Ku-band with multiple LC matching circuits and isolator, respectively, were analyzed in viewpoints of the utilization as a power detector of direct conversion Six-port. The dynamic range of designed power detectors were also measured and rvaluated as a power detector of Six-port circuit.

  • PDF

Analysis of fluctuations in ex-core neutron detector signal in Krško NPP during an earthquake

  • Tanja Goricanec;Andrej Kavcic;Marjan Kromar;Luka Snoj
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.575-600
    • /
    • 2024
  • During an earthquake on December 29th 2020, the Krško NPP automatically shutdown due to the trigger of the negative neutron flux rate signal on the power range nuclear instrumentation. From the time course of the detector signal, it can be concluded that the fluctuation in the detector signal may have been caused by the mechanical movement of the ex-core neutron detectors or the pressure vessel components rather than the actual change in reactor power. The objective of the analysis was to evaluate the sensitivity of the neutron flux at the ex-core detector position, if the detector is moved in the radial or axial direction. In addition, the effect of the core barrel movement and core inside the baffle movement in the radial direction were analysed. The analysis is complemented by the calculation of the thermal and total neutron flux gradient in radial, axial and azimuthal directions. The Monte Carlo particle transport code MCNP was used to study the changes in the response of the ex-core detector for the above-mentioned scenarios. Power and intermediate-range detectors were analysed separately, because they are designed differently, positioned at different locations, and have different response characteristics. It was found that the movement of the power range ex-core detector has a negligible effect on the value of the thermal neutron flux in the active part of the detector. However, the radial movement of the intermediate-range detector by 5 cm results in 7%-8% change in the thermal neutron flux in the active part of the intermediate-range detector. The analysis continued with an evaluation of the effects of moving the entire core barrel on the ex-core detector response. It was estimated that the 2 mm core barrel radial oscillation results in ~4% deviation in the power and intermediate-range detector signal. The movement of the reactor core inside baffle can contribute ~6% deviation in the ex-core neutron detector signal. The analysis showed that the mechanical movement of ex-core neutron detectors cannot explain the fluctuations in the ex-core detector signal. However, combined core barrel and reactor core inside baffle oscillations could be a probable reason for the observed fluctuations in the ex-core detector signal during an earthquake.

Design of RF Power Detector Module with Switch for W-CDMA Optic Repeater (스위치를 이용한 W-CDMA 광중계기용 RF 전력 검출기 모듈의 설계)

  • Lee, Yun-Bok;Cho, Jung-Yong;Shin, Kyung-Sub;Lee, Yong-An;Lee, Hong-Min
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.389-393
    • /
    • 2003
  • This paper describes the design of enhanced TSSI RF Power Detector which has wide dynamic range using switch and Log amp. This Power Detector consists of low and high gain loops, and they adaptively switched by output DC voltage which is proportioned to input power level. Because Power Detector needs to separate the channel, so architecture is heterodyne system having 70MHz intermediate frequency. This proposed RF Power Detector is settle to the satisfaction of Closed loop power control system for W-CDMA optic repeater, and the obtained dynamic range cover the higher than 50dB.

  • PDF

2.4-GHz Power Amplifier with Power Detector Using Metamaterial-Based Transformer-Type On-Chip Directional Coupler

  • Dang, Trung-Sinh;Tran, Anh-Dung;Lee, Bomson;Yoon, Sang-Woong
    • ETRI Journal
    • /
    • v.35 no.3
    • /
    • pp.554-557
    • /
    • 2013
  • This letter presents a power amplifier (PA) with an on-chip power detector for 2.4-GHz wireless local area network application. The power detector consists of a clamp circuit, a diode detector, and a coupled line directional coupler. A series inductor for an output matching network in the PA is combined with a through line of the coupler, which reduces the coupling level. Therefore, the coupler employs a metamaterial-based transformer configuration to increase coupling. The amount of coupling is increased by 2.5 dB in the 1:1 symmetric transformer structure and by 4.5 dB from two metamaterial units along the coupled line.

Design of a Low-Power MOS Monolithic Peak Detector (저전력 MOS 모놀리식 피크 감지기의 설계)

  • 박광민;백경호
    • Proceedings of the IEEK Conference
    • /
    • 2000.06b
    • /
    • pp.217-220
    • /
    • 2000
  • In this paper, A low-power MOS monolithic peak detector is presented. Designed for monolithic and low-power characteristics, this MOS peak detector can be integrated easily on the same chip as a module of large communication systems. The simulation results of this peak detector which was composed with four NMOSs and two capacitors show the power dissipation of 0.972㎽ and the good operations for 2㎓ operating pulse frequency. Therefore, it may be used as a functional block for various signal processing systems.

  • PDF

Low-Complexity and Low-Power MIMO Symbol Detector for Mobile Devices with Two TX/RX Antennas

  • Jang, Soohyun;Lee, Seongjoo;Jung, Yunho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.2
    • /
    • pp.255-266
    • /
    • 2015
  • In this paper, a low-complexity and low-power soft output multiple input multiple output (MIMO) symbol detector is proposed for mobile devices with two transmit and two receive antennas. The proposed symbol detector can support both the spatial multiplexing mode and spatial diversity mode in single hardware and shows the optimal maximum likelihood (ML) performance. By applying a multi-stage pipeline structure and using a complex multiplier based on the polar-coordinate, the complexity of the proposed architecture is dramatically decreased. Also, by applying a clock-gating scheme to the internal modules for MIMO modes, the power consumption is also reduced. The proposed symbol detector was designed using a hardware description language (HDL) and implemented using a 65nm CMOS standard cell library. With the proposed architecture, the proposed MIMO detector takes up an area of approximately $0.31mm^2$ with 183K equivalent gates and achieves a 150Mbps throughput. Also, the power estimation results show that the proposed MIMO detector can reduce the power consumption by a maximum of 85% for the various test cases.

DSP based Narrow-Band Signal Power Detector for Tracking Control of Satellite Antenna (위성통신안테나 추적제어를 위한 DSP 기반의 협대역신호 전력 검출기)

  • Kim, Won-Ho
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.7 no.4
    • /
    • pp.184-188
    • /
    • 2006
  • This paper presents DSP based narrow band satellite communication signal power detector for tracking control of mobile satellite antenna system. An analog filter based conventional power detector has poor performance due to frequency drift of carrier. Also, it is very difficult to change an analog filter bandwidth according to changed bandwidth of transmitted signal. To solve these difficulties, we proposed DSP based signal power detector, which is easy to change bandwidth of filter and to match shifted frequency of carrier. The proposed signal power detector consists of a FFT function to measure frequency drift of carrier, a programmable filter bank function to limit of received signal bandwidth and a power calculation function to measure power of filtered signal in 12-bit linear scale. Test results of implemented signal power detector, based on TMS320C5402 DSP, showed that it satisfied required functions and performances and properly operated.

  • PDF

Design of n Miniaturized LTCC Power Detector for the Tx Power Control in Wireless Communication System (무선통신시스템 송신측 제어를 위한 초소형 LTCC 전력검출부의 설계)

  • Hwang, Mun-Su;Lim, Jong-Sik;Yang, Gyu-Ryeol;Ahn, Dal
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.3
    • /
    • pp.621-627
    • /
    • 2008
  • This paper presents a compact and miniaturized power detector utilizing low temperature co-fired ceramics(LTCC) technology for the application in wireless handset system to monitor the transmitting power at the frequency of 824-849MHz. The proposed power detector is composed of detector diode, lumped components for matching network, and LTCC stripline coupler based on LTCC substrate technology. A 20dB LTCC stripline direction coupler is designed and implemented with many bending section in order to reduce the practically occupied area for miniaturization. A zero bias schottky diode is adopted for detector design because of its high speed operation with minimized loss. The measured performances of fabricated detector agree well with the predicted results with a good linearity within the effective input RF power range.

Development of the Low Power Stand-Alone Smoke and Heat Detector for the Reliability Improvement (신뢰성 개선을 위한 저전력 열연 복합식 단독경보형 감지기 개발)

  • Jee, Seung-Wook;Kim, Si-Kuk;Lee, Jae-Jin;Kim, Pil-Young;Lee, Chun-Ha
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.74-79
    • /
    • 2012
  • This study is described for development of the stand-alone smoke and heat detector (SASHD) according to the revised in 2011 type approval and performance inspection code for detector. The main improvement of the revised regulation is source. CMOS microcontroller with nano watt technology is use for development of the workable SASHD over 10 years. The low-power SASHD is developed by using the power-saving sleep mode of microcontroller, by making the low-power source voltage checker, heat detector and smoke detector. The stand-alone detector is developed by smoke and heat detector type for reduce false fire alarm. User can choose type of work between the heat detection mode and smoke & heat detection mode. The SASHD can communicate with each them using RS-485 communication supported from microcontroller. So, this study can develop the SASHD that is able to alarm more wide area when fire occurs and reduce a flash fire alarm.