• 제목/요약/키워드: Power Coupling

검색결과 1,296건 처리시간 0.025초

불연속 경계면을 갖는 광 방향성 결합기의 최적 결합효율을 위한 새로운 통합기준 (Novel Unified Criterion to Optimize Power Coupling at Optical Directional Couplers with Discontinuity Interface)

  • 호광춘
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.627-630
    • /
    • 2005
  • Novel unified criterion to optimize power coupling at optical directional couplers with discontinuous input/output interfaces is first defined and evaluated numerically. The numerical results reveal that maximum power transfer between guiding slabs without discontinuous interfaces is dominated by conventional phase-matching condition while the guiding structures with discontinuous interfaces has maximum power transfer at an equi-partition condition, which describes the power distribution condition between two rigorous modes propagating through optical couplers.

  • PDF

Control Strategy Compensating for Unbalanced Grid Voltage Through Negative Sequence Current Injection in PMSG Wind Turbines

  • Kang, Jayoon;Park, Yonggyun;Suh, Yongsug;Jung, Byoungchang;Oh, Juhwan;Kim, Jeongjoong;Choi, Youngjoon
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.244-245
    • /
    • 2013
  • This paper proposes a control algorithm for permanent magnet synchronous generator with a back-to-back three-level neutral-point clamped voltage source converter in a medium-voltage offshore wind power system under unbalanced grid conditions. The proposed control algorithm particularly compensates for the unbalanced grid voltage at the point of common coupling in a collector bus of offshore wind power system. This control algorithm has been formulated based on the symmetrical components in positive and negative rotating synchronous reference frames under generalized unbalanced operating conditions. Instantaneous active and reactive power are described in terms of symmetrical components of measured grid input voltages and currents. Negative sequential component of ac input current is injected to the point of common coupling in the proposed control strategy. The amplitude of negative sequential component is calculated to minimize the negative sequential component of grid voltage under the limitation of current capability in a voltage source converter. The proposed control algorithm makes it possible to provide a balanced voltage at the point of common coupling resulting in the generated power of high quality from offshore wind power system under unbalanced network conditions.

  • PDF

Development and verification of PWR core transient coupling calculation software

  • Li, Zhigang;An, Ping;Zhao, Wenbo;Liu, Wei;He, Tao;Lu, Wei;Li, Qing
    • Nuclear Engineering and Technology
    • /
    • 제53권11호
    • /
    • pp.3653-3664
    • /
    • 2021
  • In PWR three-dimensional transient coupling calculation software CORCA-K, the nodal Green's function method and diagonal implicit Runge Kutta method are used to solve the spatiotemporal neutron dynamic diffusion equation, and the single-phase closed channel model and one-dimensional cylindrical heat conduction transient model are used to calculate the coolant temperature and fuel temperature. The LMW, NEACRP and PWR MOX/UO2 benchmarks and FangJiaShan (FJS) nuclear power plant (NPP) transient control rod move cases are used to verify the CORCA-K. The effects of burnup, fuel effective temperature and ejection rate on the control rod ejection process of PWR are analyzed. The conclusions are as follows: (1) core relative power and fuel Doppler temperature are in good agreement with the results of benchmark and ADPRES, and the deviation between with the reference results is within 3.0% in LMW and NEACRP benchmarks; 2) the variation trend of FJS NPP core transient parameters is consistent with the results of SMART and ADPRES. And the core relative power is in better agreement with the SMART when weighting coefficient is 0.7. Compared with SMART, the maximum deviation is -5.08% in the rod ejection condition and while -5.09% in the control rod complex movement condition.

Optical Power Transfer of Grating - Assisted Directional Coupler with Three - Guiding Channels : TM modes Case

  • Ho, Kwang-Chun;Ho, Kwang-Soo
    • Journal of the Optical Society of Korea
    • /
    • 제8권4호
    • /
    • pp.149-155
    • /
    • 2004
  • Newly developed modal transmission-line theory(MTLT) is used to analyze rigorously the optical power distribution in grating-assisted directional couplers(GADCs) with three guiding channels. By defining a novel coupling efficiency ${\eta}$ amenable to the rigorous analytical solutions of modal transmission-line theory, we explicitly evaluate the power coupling and distribution of TM modes. The results reveal that the incident power is sensitively partitioned through three output channels in terms of such grating parameters as the grating period, the duty cycle, and the operating wavelength.

Omnidirectional Resonator in X-Y Plane Using a Crisscross Structure for Wireless Power Transfer

  • Kim, Donggeon;Seo, Chulhun
    • Journal of electromagnetic engineering and science
    • /
    • 제15권3호
    • /
    • pp.194-198
    • /
    • 2015
  • Magnetic resonant coupling is more efficient than inductive coupling for transferring power wirelessly over a distance. However, a conventional resonant wireless power transfer (WPT) system requires a transmitter and receiver pair in exactly coaxial positions. We propose a resonator that can serve as an omnidirectional WPT system. A magnetic field will be generated by the current flowed through the transmitter. This magnetic field radiates omnidirectionally in the x-y plane because of the crisscross structure characteristic of the transmitter. The proposed resonator is demonstrated by using a single port. To check the received S21 and transfer efficiency, we moved the receiver around the transmitter at different distances (50-350 mm). As a result, the transmission efficiency is found to be 48%-54% at 200 mm.

Analysis of a Linkage Coil for Wireless Power Transmission by Inductive Coupling

  • Gimm, Youn-Myoung;Yoo, Ho-Sang;Kim, Myoung-Wha;Yoo, Jae-Sung
    • Journal of electromagnetic engineering and science
    • /
    • 제8권1호
    • /
    • pp.23-27
    • /
    • 2008
  • Magnetic coupling delivering wireless power in capsular endoscope(CE) is described in this paper. The characteristic of the magnetic flux linkage coil which generates the induced electromotive force(emf) under the magnetic field was analyzed. With the analyzed results, a magnetic flux linkage coil system was developed and tested. It was confirmed that the magnetic flux linkage coil system could supply more than 50 mW power at 125 kHz without changing the structure of conventional CE.

확장형 자기 구조의 다중 결합 인덕터를 적용한 역률개선회로에 관한 연구 (Study on the Power Factor Correction Circuit Applying Multiple Coupling Inductor with Expandable Integrated Magnetic Structure)

  • 유정상;길용만;안태영
    • 반도체디스플레이기술학회지
    • /
    • 제17권1호
    • /
    • pp.21-26
    • /
    • 2018
  • In this paper, a multiple coupling inductor with expandable-integrated magnetic structure was proposed to enable miniaturization of external switched mode power supply (SMPS) for a large display. Inductance formula of the proposed inductor structure was derived through magnetic circuit analysis for a simple inductance designing process. The proposed inductor was applied into a 1kW class interleaved bridgeless power factor correction circuit which requires four inductors, and experimental steady state result of the circuit was compared. According to the experimental result, it was found that the proposed multiple coupling inductor shows the electrical characteristics that can replace the conventional separated inductors and is suitable for miniaturization of the SMPS since the circuit configuration is possible with one shared inductor.

파워흐름해석법을 이용한 중고주파수 대역 소음해석 프로그램 개발 (Development of Noise Analysis Program by using Power Flow Analysis in Medium-to-high Frequency Ranges)

  • 권현웅;송지훈;홍석윤
    • 대한조선학회논문집
    • /
    • 제49권5호
    • /
    • pp.384-390
    • /
    • 2012
  • Power Flow Analysis (PFA) is introduced for solving the noise and vibration analysis of structures in medium-to-high frequency ranges. The vibration analysis software, $PFADS_{C{+}{+}}$ R4 based on Power Flow Finite Element Method (PFFEM) and the noise prediction software, $NASPFA_{C{+}{+}}$ R1 based on Power Flow Boundary Element Method (PFBEM) are developed. In this paper, the coupling equation which represents relation between structural energy and acoustic energy is developed for vibro-acoustic coupling analysis. And vibro-acoustic coupling analysis software based on PFA and coupling equation is developed. Developed software is composed of translator, cavity-finder, solver and post-processor over all. Translator can translate FE model into PFADS FE model and cavity-finder can automatically make NASPFA BE model from PFADS FE model for noise analysis. The solver module calculates the structural energy density, intensity of structures, the fictitious source on the boundary and the acoustic energy density at the field in acoustic cavities. Some applications of vibro-acoustic coupling analysis software to various structures and cruise ship are shown with reliable results.

Equivalent Transmission-Line Sections for Very High Impedances and Their Application to Branch-Line Hybrids with Very Weak Coupling Power

  • Ahn, Hee-Ran;Kim, Bum-Man
    • Journal of electromagnetic engineering and science
    • /
    • 제9권2호
    • /
    • pp.85-97
    • /
    • 2009
  • As operating frequency is raised and as more integration with active and passive elements is required, it becomes difficult to fabricate more than 120 ${\Omega}$ characteristic impedance of a mierostrip line. To solve this problem, an equivalent high impedance transmission-line section is suggested, which consists mainly of a pair of coupled-line sections with two shorts. However, it becomes a transmission-line section only when its electrical length is fixed and its coupling power is more than half. To have transmission-line characteristics(perfect matching), independently of coupling power and electrical length, two identical open stubs are added and conventional design equations of evenand odd-mode impedances are modified, based on the fact that the modified design equations have the linear combinations of conventional ones. The high impedance transmission-line section is a passive component and therefore should be perfectly matched, at least at a design center frequency. For this, two different solutions are derived for the added open stub and two types of high impedance transmission-line sections with 160 ${\Omega}$ characteristic impedance are simulated as the electrical lengths of the coupled-line sections are varied. The simulation results show that the determination of the available bandwidth location depends on which solution is chosen. As an application, branch-line hybrids with very weak coupling power are investigated, depending on where an isolated port is located, and two types of branch-line hybrids are derived for each case. To verify the derived branch-line hybrids, a microstrip branch-line hybrid with -15 dB coupling power, composed of two 90$^{\circ}$ and two 270$^{\circ}$ transmission-line sections, is fabricated on a substrate of ${\varepsilon}_r$= 3.4 and h=0.76 mm and measured. In this case, 276.7 ${\Omega}$ characteristic impedance is fabricated using the suggested high impedance transmission-line sections. The measured coupling power is -14.5 dB, isolation and matching is almost perfect at a design center frequency of 2 GHz, showing good agreement with the prediction.

압전 지능 구조물을 이용한 통계적 에너지 해석 기법 (Application of Piezoelectric Smart Structures for Statistical Energy Analysis)

  • 김재환;김정하;김재도
    • 소음진동
    • /
    • 제11권2호
    • /
    • pp.257-264
    • /
    • 2001
  • In this research, piezoelectric smart structures are applied for SEA(Statistical Energy Analysis), which is well known approach for high frequency analysis. A new input power measurement based on piezoelectric electrical power measurement is proposed and compared with the conventional method in SEA. As an example, a simple aluminum beam on which piezoelectric actuator is attached is considered. By measuring the electrical impedance and electrical current of the piezoelectric actuator, the electrical power given on the actuator is found and this is In turn converted into the mechanical energy. From the measured value of the stored energy of the beam, the Internal loss factor is calculated and this value shows a good agreement with that given by the conventional method as well as the theoretical value. To compare the coupling loss factor, L-shape beam system which consists of a aluminum beam subsystem and a steel beam subsystem coupled by three pin is taken as second example. The input power and stored energy of each subsystem are found by the proposed approach. The coupling loss factor found by the electrical input power obtained from the piezoelectric actuator exhibits similar trend to the value found by the conventional method as well as the theoretical value. In conclusion, the use of SEA for high frequency application of piezoelectric smart structures is Possible. Especially, the input power that is essential for SEA can be found accurately by measuring the electrical input power of the piezoelectric actuator.

  • PDF