• 제목/요약/키워드: Power Conversion Unit

검색결과 146건 처리시간 0.035초

전력변환장치를 이용한 상용차용 무시동 에어컨 압축기 시스템 (Commercial Vehicle Anti-Start Air Conditioner Compressor System Using a Power Conversion Unit)

  • 한근우;김성곤;이충훈;최명현;정영국;임영철
    • 조명전기설비학회논문지
    • /
    • 제29권6호
    • /
    • pp.96-108
    • /
    • 2015
  • his study deals with a power conversion unit of an anti-start air conditioner compressor system for the commercial vehicle. In case of converter, to reduce the switching losses and current stresses of the device, applies LLC resonant topology. Transformer leakage inductance in the full-bridge converter is used for making the resonance with the capacitor of the voltage-doubler. Through this method we can increase power and decrease volume of system. Both circuit analysis and design guideline are described. So in this paper, power conversion unit is designed. 2.5kW anti-start air conditioner compressor system was implemented, and system operation and stability was verified through experiment.

FPGA-based Centralized Controller for Multiple PV Generators Tied to the DC Bus

  • Ahmed, Ashraf;Ganeshkumar, Pradeep;Park, Joung-Hu;Lee, Hojin
    • Journal of Power Electronics
    • /
    • 제14권4호
    • /
    • pp.733-741
    • /
    • 2014
  • The integration of photovoltaic (PV) energy sources into DC grid has gained considerable attention because of its enhanced conversion efficiency with reduced number of power conversion stages. During the integration process, a local control unit is normally included with every power conversion stage of the PV source to accomplish the process of maximum power point tracking. A centralized monitoring and supervisory control unit is required for monitoring, power management, and protection of the entire system. Therefore, we propose a field-programmable gate array (FPGA) based centralized control unit that integrates all local controllers with the centralized monitoring unit. The main focus of this study is on the process of integrating many local control units into a single central unit. In this paper, we present design and optimization procedures for the hardware implementation of FPGA architecture. Furthermore, we propose a transient analysis and control design methodology with consideration of the nonlinear characteristics of the PV source. Hardware experiment results verify the efficiency of the central control unit and controller design.

강체전차선로의 특성을 고려한 급전시스템에서 이선에 따른 철도차량 전력변환장치에 대한 특성에 관한 연구 (A Study on Characteristic of Power Conversion System in Electric Railway Vehicle According to Contact Loss in Feeding System Considering Characteristic of Rigid Bar)

  • 정노건;이환;김재문
    • 전기학회논문지
    • /
    • 제65권3호
    • /
    • pp.520-525
    • /
    • 2016
  • In this paper, Characteristic of power conversion unit of a railway vehicles according to contact loss in feeding system that applied impedance of rigid conductor is analyzed. It applied impedance of rigid bar in modeling of electric railway system. Railway vehicles are performed of modeling based on the performance of the electric railway vehicle. Effects of the contact loss in the power conversion unit were analyzed via main transformer of railway vehicle, the input and output voltage characteristics of the converter through contact loss was generated after linking the vehicle with feeding system.

8200호대 전기기관차 추진시스템 모델링을 이용한 응답특성분석 (Response Characteristic Analysis using Modeling of Propulsion System for 8200 Electric Locomotive)

  • 정노건;장진영;윤차중;김재문
    • 전기학회논문지
    • /
    • 제62권11호
    • /
    • pp.1640-1646
    • /
    • 2013
  • Conventional power conversion unit that is a major part of the propulsion system has applied GTO thyristor as a switching semiconductor device of main circuit since introduction of the 8200 electric locomotive. But problem that quick maintenance is difficult and its cost is increasing occurs because major components of the power conversion unit are slowly discontinued. To solve these, in this paper, it was analyzed the response characteristic of the propulsion system modeling of the 8200 electric locomotive using IGBT which is applied recently to ensure propulsion control technology. As results of response for a Propulsion system modeling, it show that a power conversion unit is controlled by PLL(Phase-locked loop) and SVPWM(Space Voltage PWM) respectively.

A New Symmetric Cascaded Multilevel Inverter Topology Using Single and Double Source Unit

  • Mohd. Ali, Jagabar Sathik;Kannan, Ramani
    • Journal of Power Electronics
    • /
    • 제15권4호
    • /
    • pp.951-963
    • /
    • 2015
  • In this paper, a new symmetric multilevel inverter is proposed. A simple structure for the cascaded multilevel inverter topology is also proposed, which produces a high number of levels with the application of few power electronic devices. The symmetric multilevel inverter can generate 2n+1 levels with a reduced number of power switches. The basic unit is composed of a single and double source unit (SDS-unit). The application of this SDS-unit is for reducing the number of power electronic components like insulated gate bipolar transistors, freewheeling diodes, gate driver circuits, dc voltage sources, and blocked voltages by switches. Various new algorithms are recommended to determine the magnitude of dc sources in a cascaded structure. Furthermore, the proposed topology is optimized for different goals. The proposed cascaded structure is compared with other similar topologies. For verifying the performance of the proposed basic symmetric and cascaded structure, results from a computer-based MATLAB/Simulink simulation and from experimental hardware are also discussed.

철도차량내의 전력변환장치 출력전원 분석을 통한 스위칭 기법 추정 (The Estimation on Switching Technique via Output Power Source Analysis of Power Conversion System in an Electric Railway Vehicle)

  • 김재문;이을재;윤차중;김양수
    • 전기학회논문지P
    • /
    • 제59권2호
    • /
    • pp.185-190
    • /
    • 2010
  • This paper presents the estimation on switching technique via output power source analysis of power conversion unit in electric railway vehicle. The focus of this study suggested an alternative on critical problems by using head electric power(HEP). To achieve this, we have measured output power of HEP, and measurement devices set up at output of transformer connected HEP to analysis quality on output power source of head electric power(HEP) unit in electric railway vehicle. Using results of measurement of it, parameters are assumed for simulation to confirm estimation on switching technique. It is confirmed that switching technique is Selected Harmonic Elimination PWM(SHEPWM) and inverter switching frequency is less than 500[Hz]. Throughout experiment and simulation, it is estimated that switching technique used HEP is advanced SHEPWM and switching frequency is about 300[Hz]. Also leakage inductance in transformer is about $180[{\mu}H]$ less than $365[{\mu}H]$ known.

시험용 자기부상열차의 전력변환장치 개발 특성 (Development Characteristics of a Power Conversion System in a Maglev)

  • 송병문;홍준표;김기회;오성철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.718-720
    • /
    • 1993
  • Power conversion system for a magnetically levitated vehicle consists of propulsion inverter to drive linear motor, levitation chopper to drive magnet and power source unit. This paper presents the characteristics of power conversion system in prototype Maglev system. In order to improve performance of electrical equipment IGBT is adopted in a main circuit. Audible noise is reduced to below 60 dB and size is also reduced to 1/3. This system is verified through experiment.

  • PDF

자기부상열차용 전원공급장치 설계 (Design of the Power Conversion System for the Magnetic Levitation System)

  • 송병문;계문호;오성철;조기연;김요희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.384-387
    • /
    • 1990
  • This paper describes the design of the power conversion system for the 3-ton prototype magnetic levitation system. Electric power needed for the propulsion and levitation system of the vehicle is supplied by the wayside rectifier through the power rail and is picked up by the on board power collector, and is supplied to the propulsion VVVF inverter and levitation chopper. In this paper, design characteristic of the VVVF inverter, chopper and power source unit which provides control power to the levitation controller and levitation power to the chopper is described.

  • PDF

CIM 기반의 배전자동화 시뮬레이터 (CIM based Distribution Automation Simulator)

  • 박지승;임성일
    • 조명전기설비학회논문지
    • /
    • 제27권3호
    • /
    • pp.87-94
    • /
    • 2013
  • The main purpose of the distribution automation system (DAS) is to achieve efficient operation of primary distribution systems by monitoring and control of the feeder remote terminal unit(FRTU) deployed on the distribution feeders. DAS simulators are introduced to verify the functions of the application software installed in the central control unit(CCU) of the DAS. Because each DAS is developed on the basis of its own specific data model, the power system data cannot be easily transferred from the DAS to the simulator or vice versa. This paper presents a common information model(CIM)-based DAS simulator to achieve interoperability between the simulator and the DASs developed by different vendors. The CIM-based data model conversion between Smart DMS (SDMS) and Total DAS (TDAS) has been performed to establish feasibility of the proposed scheme.

전력변환반도체 냉각용 수냉각장치의 작동특성에 관한 연구 (Study on Operating Characteristics of a Water Cooling System for cooling Power Conversion Semiconductors)

  • 유성열;김성대;임광빈;김철주
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집 특별세미나,특별/일반세션
    • /
    • pp.249-256
    • /
    • 2009
  • The cooling technology of power conversion semiconductors in the propulsion system for the HEMU(High Electrical Multi Unit) are applied in water cooling method and phase change method such as the immersed type and the heat pipe type. This research designs and manufactures the water cooling system that could cool about heat load Q=2kW and performance tests to apply it by an electric power conversion semiconductors(IGBT) cooling technology. Experimental condition made change of a flow rate, an air velocity and a heat load to confirm operation characteristics of water cooling device, and when is heat load 2kW, air velocity 20 m/s, and water flow rate 7kg/s, it is about $80^{\circ}C$ to temperature of cooling plate.

  • PDF