• Title/Summary/Keyword: Power Control Dynamic Range

Search Result 163, Processing Time 0.029 seconds

Parameter Optimization of the LC filters Based on Multiple Impact Factors for Cascaded H-bridge Dynamic Voltage Restorers

  • Chen, Guodong;Zhu, Miao;Cai, Xu
    • Journal of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.165-174
    • /
    • 2014
  • The cascaded H-Bridge Dynamic Voltage Restorer (DVR) is used for protecting high voltage and large capacity loads from voltage sags. The LC filter in the DVR is needed to eliminate switching ripples, which also provides an accurate tracking feature in a certain frequency range. Therefore, the parameter optimization of the LC filter is especially important. In this paper, the value range functions for the inductance and capacitance in LC filters are discussed. Then, parameter variations under different conditions of voltage sags and power factors are analyzed. In addition, an optimized design method is also proposed with the consideration of multiple impact factors. A detailed optimization procedure is presented, and its validity is demonstrated by simulation and experimental results. Both results show that the proposed method can improve the LC filter design for a cascaded H-Bridge DVR and enhance the performance of the whole system.

Supplementary Control of Conventional Coordinated Control for 1000 MW Ultra-supercritical Thermal Power Plant using Dynamic Matrix Control

  • Lee, Youngjun;Yoo, Euiyeon;Lee, Taehyun;Moon, Un-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.97-104
    • /
    • 2018
  • This paper proposes supplementary control of conventional coordinated control of a power plant which directly affects network frequency. The supplementary control with dynamic matrix control is applied for 1000 MW power plant with ultra-supercritical (USC) once-through boiler. The supplementary control signal is added to the boiler feedforward signal in the existing coordinated control logic. Therefore, it is a very practical structure that can maintain the existing multi-loop control system. This supplementary controller uses the step response model for the power plant system, and on-line optimization is performed at every sampling step. The simulation results demonstrate the effectiveness of the proposed supplementary control in a wide operating range of a practical 1000 MW USC power plant simulator. These results can contribute the stable operation of power system frequency.

Adaptive Power Control Dynamic Range Algorithm in WCDMA Downlink Systems (WCDMA 하향 링크 시스템에서의 적응적 PCDR 알고리즘)

  • 정수성;박형원;임재성
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.8A
    • /
    • pp.918-927
    • /
    • 2004
  • WCDMA system is 3rd generation wireless mobile system specified by 3GPP. In WCDMA downlink, two power control schemes are operated. One is inner loop power control operated in every slot. Another is outer loop power control based on one frame time. Base station (BS) can estimate proper transmission power by these two power control schemes. However, because each MS's transmission power makes a severe effect on BS's performance, BS cannot give excessive transmission power to the specific user. 3GPP defined Power Control Dynamic Range (PCDR) to guarantee proper BS's performance. In this paper, we propose Adaptive PCDR algorithm. By APCDR algorithm, Radio Network Controller (RNC) can estimate each MS's current state using received signal to interference ratio (SIR). APCDR algorithm changes MS's maximum code channel power based on frame. By proposed scheme, each MS can reduce wireless channel effect and endure outages in cell edge. Therefore, each MS can obtain better QoS. Simulation result indicate that APCDR algorithm show more attractive output than fixed PCDR algorithm.

A Study on the Dynamic Analysis of Micro-Grid System (Micro-Grid 시스템의 동특성 해석에 관한 기초 연구)

  • Son, Kwang-M.;Lee, Kye-B.;Jeon, In-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.543-544
    • /
    • 2007
  • Micro-grid consists of micro-sources which adopt environmentally friendly and reliable power sources with independent real and reactive power control capability for providing premium power quality. This paper presents dynamic modeling and the stable operating range of the micro-grid system varying the parameters of the micro-sources. Case study results show the parameters affecting the stability of the micro-grid and the stable operating range of the micro-sources.

  • PDF

Adaptive Power Control Dynamic Range Algorithm in WCDMA Downlink Systems (WCDMA 하향 링크 시스템에서의 적응적 PCDR 알고리즘)

  • Jung, Soo-Sung;Park, Hyung-Won;Lim, Jae-Sung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.9A
    • /
    • pp.1048-1057
    • /
    • 2004
  • WCDMA system is 3rd generation wireless mobile system specified by 3GPP. In WCDMA downlink, two power control schemes are operated. One is inner loop power control operated m every slot Another is outer loop power control based on one frame time. Base staion (BS) can estimate proper transmission power by these two power control schemes. However, because each MS's transmission power makes a severe effect on BS's performance, BS cannot give excessive transmission power to the speclfic user 3GPP defined Power Control Dynamic Range (PCDR) to guarantee proper BS's performance. In this paper, we propose Adaptive PCDR algorithm. By APCDR algorithm, Radio Network Controller (RNC) can estimate each MS's current state using received signal to interference ratio (SIR) APCDR algorithm changes MS's maximum code channel power based on frame. By proposed scheme, each MS can reduce wireless channel effect and endure outages in cell edge. Therefore, each MS can obtain better QoS. Simulation result indicate that APCDR algorithm show more attractive output than fixed PCDR algorithm.

Design of optimal control system of nuclear reactor for direct digital control (원자로의 직접 디지탈 제어를 위한 최적 제어계통의 설계)

  • 천희영;박귀태;이기상
    • 전기의세계
    • /
    • v.30 no.8
    • /
    • pp.509-516
    • /
    • 1981
  • The optimal control theory is applied to the design of a digital control system for a nuclear reactor. A linear dynamic model obtained at 85% of rated power and a quadratic performance index are used. A minimal order observer used in cascade with the feedback controller is suggested as a state estimator. The total reactor power control is studied in the range of 80% to 100% of rated power, with the steady state and load-following control. The control algorithm considered is suitable for implementation in direct digital control.

  • PDF

A Dual-Channel CMOS Transimpedance Amplifier Array with Automatic Gain Control for Unmanned Vehicle LADARs (무인차량 라이다용 CMOS 듀얼채널 자동 이득조절 트랜스임피던스 증폭기 어레이)

  • Hong, Chaerin;Park, Sung Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.831-835
    • /
    • 2016
  • In this paper, a dual-channel feed-forward transimpedance(TIA) array is realized in a standard $0.18-{\mu}m$ CMOS technology which exploits automatic gain control function to provide 40-dB input dynamic range for either detecting targets nearby or sensing imminent danger situations. Compared to the previously reported conventional feed-forward TIA, the proposed automatic-gain-control feed-forward TIA(AFF-TIA) extends the input dynamic range 25 dB wider by employing a 4-level automatic gain control circuit. Measured results demonstrate the linearly varying transimpedance gain of 47 to $72dB{\Omega}$, input dynamic range of 1:100, the bandwidth of $${\geq_-}670MHz$$, the equivalent input referred noise current spectral density of 6.9 pA/${\surd}$HZ, the maximum sensitivity of -26.8 dBm for $10^{-12}BER$, and the power consumption of 27.6 mW from a single 1.8-V supply. The dual-channel chip occupies the area of $1.0{\times}0.73mm^2$ including I/O pads.

Operation Results and Utility of Dynamic Pricing Response Control-Applied VRF System in Summer Season

  • Kim, Min-seok;Lee, Je-hyeon;Song, Young-hak
    • Architectural research
    • /
    • v.19 no.3
    • /
    • pp.71-77
    • /
    • 2017
  • Dynamic pricing refers to a system in which a tariff varies, according to a level of charging and applied time depending on time change. The power billing system used in the Korean Electric Power Corporation (KEPCO) is based on time of use (TOU) pricing, which is one of the dynamic pricing systems. This paper aimed to determine the operational results of a variable refrigerant flow system, to which a new control algorithm was applied, in order to respond to dynamic pricing, in summer and the utility of the new control. To do this, real measured data was acquired from a VRF system installed in a building for educational purposes, where dynamic pricing was applied for about 100 days during summer time. At the maximum load operation time period in TOU, the new control minimized operation within the indoor comfort range, an increase in refrigerant evaporation temperature in the indoor unit and the number of revolutions in a compressor in the outdoor unit was limited. As a result, power usage was decreased by 11%, and the operational cost by 14.6%. Furthermore, measurement results using the Predicted Mean Vote (PMV) model, that represented satisfaction of thermal environment, showed that 82.8% to 90.4% of the occupants of the building were satisfied during operation when the new control was applied.

Design of RF Power Detector Module with Switch for W-CDMA Optic Repeater (스위치를 이용한 W-CDMA 광중계기용 RF 전력 검출기 모듈의 설계)

  • Lee, Yun-Bok;Cho, Jung-Yong;Shin, Kyung-Sub;Lee, Yong-An;Lee, Hong-Min
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.389-393
    • /
    • 2003
  • This paper describes the design of enhanced TSSI RF Power Detector which has wide dynamic range using switch and Log amp. This Power Detector consists of low and high gain loops, and they adaptively switched by output DC voltage which is proportioned to input power level. Because Power Detector needs to separate the channel, so architecture is heterodyne system having 70MHz intermediate frequency. This proposed RF Power Detector is settle to the satisfaction of Closed loop power control system for W-CDMA optic repeater, and the obtained dynamic range cover the higher than 50dB.

  • PDF

Control and Implementation of Dual-Stator-Winding Induction Generator for Variable Frequency AC-Generating System

  • Bu, Feifei;Hu, Yuwen;Huang, Wenxin;Shi, Kai
    • Journal of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.798-805
    • /
    • 2013
  • This paper presents the control and implementation of the dual-stator-winding induction generator for variable frequency AC (VFAC) generating system. This generator has two sets of stator windings embedded into the stator slots. The power winding produces the VFAC power to feed the loads, and the control winding is connected to the static excitation controller to control the generator for output voltage regulation with speed and load variations. On the basis of the idea of power balance, an instantaneous slip frequency control (ISFC) strategy using the information of both the output voltage and the output power is used in this system. A series of experiments is carried out on a 15 kW prototype for verification. Results show that the system has good static and dynamic performance in a wide speed range, which demonstrates that the ISFC strategy is suitable for this system.