• Title/Summary/Keyword: Power Conditioning

Search Result 1,093, Processing Time 0.033 seconds

Design of 1kW Hybrid CC/CV PCS (정전류·정전압 기능의 1kW급 하이브리드 PCS 설계)

  • Lee, Jae Min
    • Journal of Digital Contents Society
    • /
    • v.14 no.4
    • /
    • pp.529-536
    • /
    • 2013
  • Lack of proper amount of sun lights and wind strength which are major factors of solar power and wind power system may cause poor electric power generation and decrease the lifetime of batteries that are major energy saving units. Because the PCS, which is essential in solar and wind power system, for small power generation system has been rarely developed an efficient and stable PCS for small power generation system is highly required. In this paper, we design a new constant current/constant voltage type hybrid PCS by which stand alone/grid connected operation with commercial power system is available and implement the designed PCS as a protype for performance verification.

Implementation of Grid-interactive Current Controlled Voltage Source Inverter for Power Conditioning Systems

  • Ko Sung-Hun;Shin Young-Chan;Lee Seong-Ryong
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.4
    • /
    • pp.382-391
    • /
    • 2005
  • Increasing of the nonlinear type power electronics equipment, power conditioning systems (PCS) have been researched and developed for many years in order to compensate for harmonic disturbances and reactive power. PCS's not only improve harmonic current and power factor in the ac grid line but also achieves energy saving used by the renewable energy source (RES). In this paper, the implementation of a current controlled voltage source inverter (CCVSI) using RES for PCS is presented. The basic principle and control algorithm is theoretically analyzed and the design methodology of the system is discussed. The proposed system could achieve power quality control (PQC) to reduce harmonic current and improve power factor, and demand side management (DSM) to supply active power simultaneously, which are both operated by the polarized ramp time (PRT) current control algorithm and the grid-interactive current control algorithm. A 1KVA test model of the CCVSI has been built using IGBT controlled by a digital signal processor (DSP). To verify the proposed system, a comprehensive evaluation with theoretical analysis, simulation and experimental results is presented.

A Study on the Yearly Thermal Environmental Characteristics in Underground Space (지하거주공간의 연간 열환경에 관한 연구)

  • Jeong, H.M.;Chung, H.S.
    • Journal of Power System Engineering
    • /
    • v.2 no.3
    • /
    • pp.27-33
    • /
    • 1998
  • The room temperature and air conditioning load in the underground space have been investigated numerically by the unsteady heat conduction equation. The model room has 3 m in height and 10 m in width, and it's position in the underground depth are 0.5 m to 5 m. When the room was located around surface, the room temperatures were strongly influenced by the atmosphere. But the underground depth is more than 2 m, the yearly temperature amplitude was small and the temperature phase was delayed. Up to 5 m of the depth, the cooling and heating load was decreased rapidly, but over 10 m of the depth, the air conditioning load was constant.

  • PDF

The optimal parameters in series-series counterflow chillers system within air conditioning (공조장치내의 직렬-직렬 대향류 냉각기에서 최적 변수)

  • Phu, Nguyen Minh;Hung, Bui Ngoc;Lee, Geun-Sik
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1332-1336
    • /
    • 2009
  • If water-chillers are arranged in series-series counterflow, compressor lift of each chiller will be decreased in comparison with water-chillers in parallel. That means that compressor power of the chillers in series will be lower than that of chillers in parallel. However, the pressure drop of the water flow through the chillers in series will increase, and thus increase the power of water pumps. This disadvantage will be made good by increasing the temperature difference of water flow through evaporator and condenser, but the water flow rates will decrease. This paper explores the optimal parameters in system of series-series counterflow for central chilled water plants such as the leaving chilled water temperature, the leaving condenser water temperature, condenser water flow rate and number of chillers in series.

  • PDF

Modeling of Stochastic Properties of Internal Heat Generation of an Office Building for Slab Cooling Storage (사무소건물의 슬래브축냉을 위한 내부발열부하의 확률적 성상 모델화)

  • Jung, Jae-Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.12
    • /
    • pp.836-842
    • /
    • 2011
  • It has been shown that the air-conditioning system with slab cooling storage is effective in cutting peak load and utilizing nighttime electric power. The stochastic properties of internal heat generation which has great influence on the cooling load are examined in this paper. Based on the measured cooling load and electric power consumption in an office building with slab cooling storage, stochastic time series models to simulate these random processes are investigated. Furthermore, a calculated result by an optimal control method of thermal analysis taking into account the internal heat is compared with the measured cooling load.

Development of the Inverter System with UPS Function for the Air-Conditioning Blower (UPS 기능을 갖는 A/C Blower용 Inverter 시스템 개발)

  • Lim, Seung-Beom;Lee, Yun-Ha;Ji, Jun-Keun;Mok, Hyung-Soo;Hong, Soon-Chan
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.345-346
    • /
    • 2010
  • The HVAC(Heating Ventilation and Air Conditioning) system is only controlled by turn on/turn off operations against to AC 380V input. Therefore, the efficiency of the system is reduced and noise occurs. Also, the blower is shut down at the AC power failure. In this paper, the inverter system with UPS function for the A/C(Air Conditioning) blower is proposed. Proposed inverter system which is powered from the AC and DC voltage can control speed, operation mode, and soft-start time using CAN communication. In case of the CAN communication failure, RS-232 communication could be used to control the hardware directly by the engineer that can solve existing problems. To verify the validity of proposed inverter system, simulations and experiments are carried out.

  • PDF

Study on the Peltier Module to Insure the Structural Stability (Peltier module의 구조적 안정성 확보에 관한 연구)

  • Jun, Jong-Hoon;Kim, Jae-Jung;Kim, In-Kwan;Kim, Young-Soon
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1144-1149
    • /
    • 2006
  • Electric power is generated by Seeback Effect if there is thermal difference in pettier module. Peltier module is composed by alumina, Bi-Te semiconductor and insulation (or air). If load is increased in pettier module, the alumina of module will be destroyed. One of the preventing method of module destruction is using damper between module and heat source. But the electric Power is dropped because of decrease of thermal difference, if thermal conductivity of damper was tourer than other thermoelectric materials. We design, Polymer Pad for enhancing thermoelectric porter. As the result of these experiment, Polymer Pad is more superior than the Rubber in the stability and thermal conduction.

  • PDF

마이크로 유동과 마이크로 연료전지 기술

  • Im, Dong-Uk;Seong, Jae-Yong
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.37 no.7
    • /
    • pp.9-13
    • /
    • 2008
  • 첨단 건물 및 도시 등에 설치된 유비쿼터스 센서 네트워크의 안정적인 운용을 위하여, 이 시스템에 지속적으로 전력을 공급할 수 있는 Micro Power Generation기술을 소개하고자 한다.

  • PDF

Development of 250kW Power Conditioning System for Molten Carbonate Fuel Cell Power Generation System (250kW급 용융탄산염 연료전지 발전시스템용 전력변환기 개발)

  • Lee, J.H.;Jung, H.J.;Baek, S.T.;Kang, H.H.;Chung, J.M.;Suh, I.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.231-233
    • /
    • 2007
  • 본 논문은 신 발전방식 중 하나인 용융탄산염형 연료전지(Molten Carbonate Fuel Cell, 이하 MCFC) 발전시스템에서 생성된 전력을 계통에 안정적으로 변환, 주입하기 위한 계통연계형 전력변환기를 설계, 제작하고 성능 시험을 수행한 결과이다. 250kW급 MCFC 시스템의 정격 사양 및 스택의 운전 형태를 기반으로 250kW급 전력변환기 구조 및 단위기기를 설계하였고 전력변환기는 크게 DC/DC 컨버터부와 DC/AC 인버터부로 구성된다. 본 논문은 MCFC 발전 시스템에 적용되는 전력변환기(Power Conditioning System, 이하 PCS)를 제작하고 성능을 확인하는데 목적이 있다.

  • PDF