• 제목/요약/키워드: Power Closed-Loop Control

검색결과 265건 처리시간 0.026초

모드절환식 다기능 무정전 전원장치 (Multifunctional UPS with Mode Transfer Method)

  • 김제흥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1049-1051
    • /
    • 2001
  • This paper proposes a new control strategy of multifunctional uninterruptible power supply(UPS) with the performance of active power filter which compensate the harmonics and reactive power. To improve the transient response for the effective compensation in active power filter mode, it is considered that a simple and precise calculation method of the compensation reference current for the harmonics and reactive power compensation. So a novel closed-loop control strategy is used to calculate the reference current. And the current regulated instantaneous voltage control scheme is used in back-up power mode. The system model and control algorithm are described and analyzed, and the system performance is verified by the simulation results.

  • PDF

Improvement of Channel Estimation Algorithm in Mobile/Satellite Communication Systems

  • Kim, Byung-Gi;Ryoo, Sang-Jin;Lee, Chang-Hun;Choi, Kwang-Seok;Kim, Seong-Hwan;Kang, Seong-Jun;Na, Cheol-Hun
    • Journal of information and communication convergence engineering
    • /
    • 제7권3호
    • /
    • pp.404-411
    • /
    • 2009
  • In this paper, in order to increase system capacity and reduce the transmitting power of the user's equipment, we propose an efficient power estimation consisting of a modified open-loop power control (OLPC) and closed-loop power control (CLPC) schemes for mobile/satellite communications systems. The OLPC works well if the forward and reverse links are perfectly correlated and the CLPC is sensitive to round-trip delay (RTD). Therefore, it is not effective in mobile/satellite system. In order to solve the above problem, we added monitoring equipment to both the OLPC and CLPC to use information about transmitting power that has not yet been received by the receiver over the satellite/ATC channel. Moreover, we adapted an efficient pilot diversity of both OLPC and CLPC in order to get a better signal to interference plus noise ratio (SIR) estimation of the received signal.

미사용 OVSF 부호를 이용한 WCDMA 역방향 링크 수신기의 SIR 기반 전력제어 성능 분석 (Performance of SIR-based power control using unused OVSF codes for WCDMA reverse link receiver)

  • 이영용;박수진;안재민;임민중;정성현;최형진
    • 대한전자공학회논문지TC
    • /
    • 제40권7호
    • /
    • pp.282-292
    • /
    • 2003
  • 본 논문에서는 폐루프 고속 전력 제어를 수행하여 WCDMA(Wideband Code Division Multiple Access) 역방향 링크 수신기 시스템의 성능을 분석하였다. 고속 전력 제어를 수행하기 위해서는 기지국에서 SIR(Signal to Interference power Ratio)이 정확히 측정되어야 한다. 이를 위해 본 논문에서는 간단한 구조를 갖는 SIR 측정 알고리즘을 제안하였다. 제안한 구조는 미사용 OVSF(Orthogonal Variable Spreading Factor) 부호를 이용하여 간섭 전력을 측정하는 새로운 방식이다. 본 논문에서 제안된 SIR 측정 알고리즘과 참고 문헌 [1]에 제시된 기존외 SIR 측정 알고리즘을 폐루프 고속 전력 제어에 적용하여 성능을 비교하였다. 동기 데이터 복조를 수행하기 위한 채널 추정 알고리즘으로는 Κ=2인 WMSA (Weighted Multi-Slot Averaging) 채밀 추정 필터를 적용하였다. 모의 실험 결과를 통해 제안한 SIR 측정 방식이 평균 BER 10/sup -3/관점에서 수신 Ε/sub b//Ι/sub 0/를 최대 0.9㏈ 감소시킬 수 있으며 다중 경로 수가 증가할수록 그리고 페이딩 속도가 더 빨라질수록 성능 차이는 더욱 커진다는 것을 제시하였다.

Implementation of Robust Prediction Observer Controller for DC-DC Converter

  • Shenbagalakshmi, R.;Raja, T. Sree Renga
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1389-1399
    • /
    • 2013
  • A discrete controller is designed for low power dc-dc switched mode power supplies. The approach is based on time domain and the control loop continuously and concurrently tunes the compensator parameters to meet the converter specifications. A digital state feedback control combined with the load estimator provides a complete compensation, which further improves the dynamic performance of the closed loop system. Simulation of digitally controlled Buck converter is performed with MATLAB/Simulink. Experimental results are given to demonstrate the effectiveness of the controller using LabVIEW with a data acquisition card (model DAQ Pad - 6009).

Multifunctional Uninterruptible Power Supply (UPS) System

  • Kim, Je-Hong;Choi, Yong-Joon;Choi, Jae-Ho
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.813-817
    • /
    • 1998
  • This paper proposes a new control strategy of bidirectional uninterruptible power supply(UPS) with the performance of active power filter which compensate the harmonics and reactive power. To improve the transient response for the effective compensation in active power filter mode. It is considered that a simple and precise calculation method of the compensation reference current for the harmonics and reactive power compensation. So a novel closed-loop control strategy is used to calculate the reference current. The system model and control algorithm are described and the system performance is verified by the simulation and experimental results.

  • PDF

디지털 폐루프 신호처리를 적용한 광섬유 자이로 설계 및 성능평가 (Design and Performance Evaluation of Fiber Optic Gyro with Digital Closed-loop Processing)

  • 도재철;정경호
    • 한국항공우주학회지
    • /
    • 제34권9호
    • /
    • pp.97-103
    • /
    • 2006
  • 본 논문에서는 디지털 폐루프 신호처리를 이용한 광섬유자이로를 설계하고 성능 시험한 결과를 제시하였다. 회전 입력에 대한 자이로의 피드백 제어를 위해 디지털 세로다인 변조기법이 적용되었고, 환산계수의 안정화를 위해 변조진폭 및 광전력 제어회로를 설계하였다. 프로토타입 광섬유자이로를 시험한 결과, 바이어스 안정도 0.34 deg/hr, 환산계수 비선형도약 100ppm , 회전감지 영역 ${\pm}500$ deg/sec의 성능을 얻었다.

시간지연을 가진 발전소 제어시스템의 자동동조를 위한 System identification 방법 (System identification method for the auto-tuning of power plant control system with time delay)

  • 윤명현;신창훈;박익수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.1008-1011
    • /
    • 1996
  • Most control systems of power plants are using classical PID controllers for their process control. In order to get the desired control performances, the correct tuning of PID controllers is very important. Sometimes, it is necessary to retune PID controllers after the change of system operating condition and system design change, etc. Commercial auto-tuning controllers such as relay feedback controller can be used for this purpose. However, using these controllers to the safety-critical systems of nuclear power plants may be cause of unsafe operation, because they are using test signals for tuning. A new system identification auto-tuning method without using test signal has been developed in this paper. This method uses process input/output signals for system identification of unknown control process. From the model information of control process which was obtained from system identification approach, the optimal PID parameters can be calculated. The method can be used in the safety-critical systems because it is not using test signals during system modeling process.

  • PDF

A Feasible Approach for the Unified PID Position Controller Including Zero-Phase Error Tracking Performance for Direct Drive Rotation Motor

  • Kim, Joohn-Sheok
    • Journal of Power Electronics
    • /
    • 제9권1호
    • /
    • pp.74-84
    • /
    • 2009
  • The design and implementation of a high performance PID (Proportional Integral & Differential) style controller with zero-phase error tracking property is considered in this article. Unlike a ball screw driven system, the controller in a direct drive system should provide a high level of tracking performance while avoiding the problems due to the absence of the gear system. The stiff mechanical element in a direct drive system allows high precise positioning capability, but relatively high tracking ability with minimal position error is required. In this work, a feasible position controller named 'Unified PID controller' is presented. It will be shown that the function of the closed position loop can be designed into unity gain system in continuous time domain to provide minimal position error. The focus of this work is in two areas. First, easy gain tunable PID position controller without speed control loop is designed in order to construct feasible high performance drive system. Second, a simple but powerful zero phase error tracking strategy using the pre-designed function of the main control loop is presented for minimal tracking error in all operating conditions. Experimental results with a s-curve based position pattern commonly used in industrial field demonstrate the feasibility and effective performance of the approach.

THE DYNAMICAL PERFORMANCE OF CONTROLLED FLYWHEELING DUAL CONVERTER-FED DC MOTOR DRIVES WITH SIMULATANEOUS CONTROL AND FUZZY PI CONTROLLER

  • Soltani, Jafar;Sojdei, Jamshid
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.414-419
    • /
    • 1998
  • This paper describes the dynamical performance of a four-quadrant circulation current mode control of dc motor drive, using the controlled flywleeling technique, a four-quadrant closed-loop control drive with an inner current control loop and a speed fuzzy PI regulator is designed. The obtained computer simulation results of a dc motor drive below and above the base speed are demonstrated. These result show that compare to a conventional dual-converter-fed dc motor drive with simultaneous control, the overal system performance has been improved and also, agood stability and robstness has been achieved.

  • PDF

PDFF 제어기법을 이용한 단상 UPS 인버터 전압, 전류제어에 관한 연구 (A study on single phase UPS inverter control with PDFF method)

  • 오방원;이상용;이용균;전윤석;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(2)
    • /
    • pp.799-802
    • /
    • 2004
  • There are many methods in controlling inverter's voltage and currents. most of all, PI control method is a general method. PI control has some merits. But, PI control has zero effect. So, steady-state response errors always exist by the zero effect. For removing the steady-state error, This paper presents the modeling, design and analysis of the double loop feedback control scheme. and computing the value of parameters and applying In the single-phase full bridge inverter for comparison and analysis between the PI control and PDFF control. The system model is employed to examine the dynamics of power circuit and select appropriate feedback variables for stable operation of the closed-loop UPS inverter system. It analyzes and proves the output characteristic of inverter system with the PDFF control.

  • PDF