• Title/Summary/Keyword: Power Circuit Breaker

Search Result 329, Processing Time 0.036 seconds

A Study On The Arc Resistance of $SF_6$ Gas Circuit Breaker ($SF_6$ 가스차단기의 아크저항에 관한 연구)

  • Chong, Jin-Kyo;Lee, Woo-Young;Kim, Gyu-Tak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1566-1570
    • /
    • 2007
  • [ $SF_6$ ] gas circuit breakers are widely used for short circuit current interruption in EHV(Extra High Voltage) or UHV(Ultra High Voltage) power systems. To develop $SF_6$ gas circuit breakers, the arc resistance value is necessary to compare experimental results to numerical ones. The arc resistance value can be obtained from a breaking test with a $SF_6$ gas circuit breaker. The direct testing or synthetic testing facility is widely used to verify the breaking ability for $SF_6$ gas circuit breakers. We employed the simplified synthetic testing facility to test a $SF_6$ gas circuit breaker prototype. The arc resistance characteristic was measured and calculated under the various experimental conditions. This arc resistance value can be used for verifying the numerical results from arc simulation in a circuit breakers.

A Vacuum Circuit Breaker Model for simulation of Transient Overvoltages Using the PSCAD/EMTDC (PSCAD/EMTDC를 이용한 과도전압 모의를 위한 진공차단기 모델 개발)

  • Lee, Wook-Hwa;Lee, J.H.;Lee, Jin;Choi, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.232-234
    • /
    • 2002
  • A Vacuum Circuit Breaker Model for simulation of transient overvoltages was developed by using the PSCAD/EMTDC. The Model includes the power frequency chopping current. Breaker withstand voltage, and quenching capability of High frequency currents. To verify the abilities of the breaker model, the simulation on the Lindmayer's single-phase circuit was carried out. The results show that using the proposed model, the transient overvoltages, current chopping, and multiple reignitions of vacuum breaker are properly reproduced as real phenomena. In further study, virtual chopping current will be incorporated into the model for 3 phase system.

  • PDF

Study of Self-excited Resonant DC Circuit Breaker in Future DC Grid (향후 DC 전력 계통에서의 자려 공진 DC 차단기에 관한 연구)

  • Guo, Qinglei;Yoon, Minhan;Jang, Gilsoo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.396-397
    • /
    • 2015
  • With the increasing utilization of high-voltage, direct current (HVDC) transmissions in modern power systems, the DC grid is becoming a hot topic in academic and practical systems. In the DC grid, one of the urgent problems is the fast clearance of the DC fault in the DC network. One preferred method is to isolate the faulty point from the DC network in a short time. The DC circuit breaker is to interrupt the overcurrent after DC faults occur. In this paper, a self-excited resonant DC circuit breaker is an easy and cheap equipment to interrupt the DC fault current. The Mayr's arc model is utilized to simulate the self-excited DC circuit breaker in a DC test system in PSCAD/EMTDC.

  • PDF

Breaking test of UHV circuit breaker by ANSI/IEEE standard (ANSI/IEEE를 적용한 초고압 차단기의 차단시험)

  • Park, Seung-Jae;Rhyou, Hyeong-Kee;Kang, Young-Sik;Koh, Heui-Seog
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.467-469
    • /
    • 2003
  • IEC(International Electrotechnical Commission) 62271-100 has been adopted for the design test of circuit breaker which is used as the main protecting device of power system. But, it is also necessary to separately receive the testing certificate in accordance with ANSI/IEEE standard for getting into the american market. Up to now, several domestic companies have completed the ANSI/IEEE testing in medium circuit breaker of distribution system, but they recently started the ANSI/IEEE testing in ultra high-voltage class of transmission and substation system. This paper introduces the testing techniques and its results for the making and breaking performance of 145kV, 40kA $SF_6$ gas circuit breaker which was firstly performed in KERI(Korea Electrotechnology Institute) by the ANSI/IEEE standard.

  • PDF

Implementation of Solid-State Circuit Breaker for DC gird (DC 그리드를 위한 Solid-State Circuit Breaker의 구현)

  • Kim, Jin-Young;Sim, Jae-Hyeok;Kim, In-Dong;Nho, Eui-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.111-112
    • /
    • 2012
  • 전력효율을 높일 수 있는 DC 전송이 주요 관심사가 됨에 따라 전력품질에 대한 기술이 요구된다. DC 그리드의 전력품질을 위해서는 반도체 차단기(Solid-State Circuit Breaker : SSCB)는 필수요소이다. 하지만 기존의 반도체 차단기는 AC 그리드에 기반을 두고 제안되었기 때문에 DC 그리드에 적용하기 어렵다. 따라서 본 연구에서는 DC 그리드에 적용 가능한 SSCB (Solid-State Circuit Breaker : SSCB)을 제안한다. 제안하는 DC SSCB는 사고 전류를 제한하며 사고 지점의 신속한 차단이 가능하다. 제안한 회로는 시뮬레이션을 통해 단락 사고를 모의하여 시스템의 동작 특성을 검증하였다.

  • PDF

Analysis of Active Characteristic the Low-voltage Circuit Breaker for Harmonics (고조파에 의한 저압용 차단기의 동작특성 해석)

  • Choi, M.G.;Jeong, B.H.;Park, J.C.;Kim, H.G.;Mok, H.S.;Choe, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1474-1476
    • /
    • 2005
  • Because MCCB, ELB, etc. discharge both technical and economical duty, it is important that the study of circuit breaker guarantee high-performance and realize the power distribution system with reliability. Because of complexity electrical equipment, the accident with imbalance and flicker occur often according to technical improvement. However, study of accident with harmonics remains. In this paper, the essential characteristic of circuit breaker is introduced. To analysis operation of circuit breaker, theoretical model and several simulations have been performed.

  • PDF

Extension of Cut-off Capacity of DC Circuit Breaker due to Superconducting Coil Application (초전도 코일 적용으로 인한 DC 차단기의 차단 용량 증대)

  • Choi, Hye-Won;Choi, Hyo-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.4
    • /
    • pp.593-597
    • /
    • 2019
  • We proposed a current Interruption type DC superconducting circuit breaker(I-DC SCB), a protection device that combines the current limiting technology of a superconductor with the cut-off technology of circuit breaker. Unlike existing protective devices, the current I-DC SCB is a device that combines two protection functions, notably improving failure probability and operational reliability. It is also applicable to all DC systems, such as HV, MV, and LVDC, due to the ease in capacity increase. The 100 kV I-DC SCB was designed after taking into account the actual power system conditions, followed by an analysis of the transient characteristics and the breaking range of the limiter. The results of the analysis showed that the I-DC SCB had a fault current limit of about 75% at the rated voltage, and completed the cut-off operation within about 20 ms.

The Transient Analysis of Instant Short-Circuit Test Equipment For Earth Leakage Circuit Breaker (IEC60947-2에 따른 누전차단기의 순시단락시험 과도현상에 대한 연구)

  • Ryu, Haeng-Soo;Kim, Myeong-Seok;Han, Gyu-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.357-359
    • /
    • 2003
  • This paper is for the transient analysis of instant short-circuit test equipment according to the test of tripping limits and characteristics under IEC 60947-2. The in-rush current is harmful to almost equipments and the exact testing is not made because of it. LGIS has a instant short-circuit test equipment, but it is not suitable for carrying out instant short-circuit test on ELB(Earth Leakage Circuit breaker) by reason of that. Now, I am going to show a solution for that problem. After applying this method, manufacturer is going to acquire the exact testing result according to the IEC standard. Moreover, Testing laboratory will be trusted by clients.

  • PDF

The Protective Co-ordination between Low-Voltage Circuit-Breaker (저압차단기기의 보호협조)

  • Park, S.C.;Oh, J.S.;Lee, B.W.;Ryu, M.J.;Seo, J.M.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.340-343
    • /
    • 2001
  • In an electrical network, electrical power are transmitted by a various of protection, isolation and control electric circuit devices. This thesis deals with the protection function between circuit-breakers. The protective coordination concerns the behaviour of two devices placed in series in an electrical network, with a short-circuit downstream circuit-breaker. It has two basic principles: First, discrimination which is an increasing requirement of low voltage electrical distribution systems. Second, which is less well known: cascading, which consists of installing a device, whose breaking capacity is less than the three-phase short-circuit current at its terminals and helped by main circuit-breaker. The important advantage of cascading is to be able to install at a branch circuit-breaker of a lesser performance without endangering the safety of the installation for more economical usage. To determine and guarantee co-ordination between two circuit breakers, it is necessary to carry out a theoretical approach, first, and then confirm the results by means of standard tests. This is illustrated in appendix A of IEC 947-2.

  • PDF

Arc Resistance and Light Reflectance of PTFE for Circuit Breaker (차단기용 PTFE의 내아크성과 광반사율)

  • Park, Hoy-Yul;Kang, Dong-Pil;Ahn, Myeong-Sang;Lee, Tae-Joo;Lee, Tae-Hui;Myung, In-Hae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.200-203
    • /
    • 2003
  • A study on the arc resistance and light reflectance of PTFE (polytetrafluoroethylene) nozzle for circuit breaker is presented. PTFE has been used widely as a material for circuit breaker nozzle. PTFE has excellent electrical resistivity, high melt viscosity, chemical inertness, heat resistance and low loss factor. PTFE melts at $327\;^{\circ}C$ but the viscosity is very high above the melting point. In the arcing environment in a circuit breaker, the fraction of the power is emitted out of the arc and reaches the nozzle wall by radiation, causing ablation at the surface and in the depth of the wall. Some fraction of the radiation power emitted out of the arc directly break up the chemical bonds at the surface while some fraction of the radiation power penetrates into the wall, heats up the material to evaporation temperature and causes damages deeper inside the volume of the nozzle. In this paper, some fillers that have endurance in the high temperature arc environment were added into PTFE. Adding some fillers into PTFE was expected to be efficient in improving the endurability against radiation. The light reflectance and arc resistance of PTFE composites were investigated.

  • PDF