• 제목/요약/키워드: Potential interference

검색결과 321건 처리시간 0.04초

Study on the Influence of Stray current Between Sacrificial Anode Cathodic Protection and Impressed Current Cathodic Protection in Marine Environment

  • Jeong, Jin-A;Kim, Ki-Joon
    • Corrosion Science and Technology
    • /
    • 제11권3호
    • /
    • pp.77-81
    • /
    • 2012
  • Cathodic protection(CP) is widely used as a means of protecting corrosion for not only marine structures like ship hulls and offshore drilling facilities, but also underground structures like buried pipelines and oil storage tanks. The principle of CP is that the anodic dissolution of metal can be protected by supplying electrons to the cathode metal. When unprotected structures are nearby to CP systems, interference problems between unprotected and protected structures may be happened. The stray current interference can accelerate the corrosion of nearby structures. So far many efforts have been made to reduce the interference in the electric railway systems adjacent to the underground metal structures like buried pipelines and gas/oil tanks. During recent few decades the protection technologies against stray current induced corrosion have been significantly improved and a number of techniques have been developed. However, there is very limited information an marine environments. Some complex harbor structures are protected by two cathodic protection systems, i.e. sacrificial anode cathodic protection(SACP) and impressed current cathodic protection(ICCP). In this case, when the protection current from sacrificial anodes returns to the cathode through electrolyte, it passes through nearby other low resistance metal structures. In many cases the stray current of ICCP systems influences the function of SACP. In this study, the risk of stray current from the SACP system to adjacent reinforced concrete structures has been verified through laboratory experiments. Concrete and steel pile structures modeled a part of bridge have been investigated in terms of CP potential and current between the two. The variation of stray current according to the magnitude of ICCP/SACP has been studied to mitigate it and to suggest the proper protection criteria.

DTV 서비스와 IMT 서비스간 간섭 영향 연구 (A Study on Interference Effect between DTV Service and IMT Service)

  • 심용섭;이일규;장상현;조인경
    • 한국인터넷방송통신학회논문지
    • /
    • 제10권3호
    • /
    • pp.61-68
    • /
    • 2010
  • 국내에서는 아날로그 TV를 디지털 TV (DTV)로 전환하는 과정에서 채널 14 ~ 채널 51(470 MHz ~ 698 MHz)에 DTV 서비스의 할당을 계획하고 있다. 그러므로 DTV 서비스와 인접한 채널에 할당될 잠재적 서비스와의 간섭영향 분석이 필요하다. 이에 본 논문은 DTV 서비스가 채널 51(692 MHz ~ 698 MHz), IMT 서비스가 채널 52(698 MHz ~ 704 MHz)의 할당을 가정한 후, Spectrum Engineering Advanced Monte Carlo Analysis Tool(SEAMCAT)을 이용하여 DTV 서비스와 IMT 서비스간의 간섭 영향을 분석하였다. 분석을 위해 네 가지 시나리오를 설정하고 IMT 서비스로부터 DTV 서비스에 미치는 간섭의 확률과 DTV 서비스로부터 IMT 서비스에 미치는 용량의 손실을 분석하여 이를 바탕으로 보호 대역을 산출하였다. 그 결과 편파감쇠를 반영한 IMT 서비스의 다운링크(Downlink)와 DTV간에 간섭 분석시 8 MHz의 보호대역이 산출되었고, 최악의 경우인 도심지역에서 IMT 서비스 BS(Base Station)의 블러킹 레벨을 15 dB 증가한 후 DTV 서비스와 IMT 서비스 업링크(Uplink)간에 간섭 분석시 6 MHz의 보호 대역이 산출되었다.

수중에서 광대역 간섭 패턴 정합을 이용한 음원의 위치 추정 연구 (A Study on Underwater Source Localization Using the Wideband Interference Pattern Matching)

  • 천승용;김세영;김기만
    • 한국음향학회지
    • /
    • 제26권8호
    • /
    • pp.415-425
    • /
    • 2007
  • 본 논문에서는 간섭 패턴 정합을 이용한 수중 광대역 음원의 위치 추정법을 제안한다. 두 개의 센서 스펙트로그램에 나타나는 간섭 패턴의 정합을 통해 음원과 두 센서간의 상대적인 거리비를 추정하고 이를 아폴로니오스 원의 방정식에 적용하였다. 아폴로니오스의 원은 두 정점에 이르는 거리비가 일정한 값으로 운동하는 점의 자취로 정의되며, 음원의 위치로 추정 가능한 궤적을 나타낼 수 있다. 그러나 아폴로니오스의 원 하나만으로는 정확한 음원의 위치추정이 어렵다. 그러므로 또 하나의 위치 궤적을 추정 할 수 있는 방정식이 필요하다. 따라서 음원과 두 센서간의 신호도달 시간차이를 이용한 쌍곡선의 방정식을 도입하여 최종적인 음원의 위치는 두 방정식의 교점의 좌표로 추정하였다. 제안된 방법의 성능 평가를 위하여 모의실험을 통해 위치 추정 오차율을 분석하고, 해상실험을 통하여 실제 적용 가능성을 분석하였다. 모의실험 및 해상실험 결과 본 논문에서 제안된 위치 추정 알고리즘이 오차율 10% 이내의 성능을 나타내었다.

대지저항률에 따른 최적화 접지 해석 (The Optimization Grounding Analysis for Soil Resistivity)

  • 정연하;장태준;곽희로;노영수;송길목
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.241-245
    • /
    • 2004
  • The electric safety tends to be more important according to electric facilities's increase and its use in these days. This paper analyzes soil resistivity of two areas in the country using CDEGS(Current Distribution, Electromagnetic Interference, Grounding and Soil Structure, Canada). We designed rod and mesh grounding system and made a comparative study of ground resistance, GPR(Main Electrode Potential Rin), step voltage and touch voltage. Then we could analyz only the safety but also economical efficiency in elocution of grounding. As a result of simulation, ground resistance, GPR(Main Electrode Potential Rise), step voltage and touch voltage became higher in proportion to soil resistivity. Therefore we expect to estimate the propriety of grounding system design through accumulation and analysis of data in consideration of characteristics of soil.

  • PDF

지하철 누설전류 무선 원격 감시시스템 적용 사례 (A case study of remote wireless monitoring system for stray current due to subway system)

  • 배정효;하윤철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.1817-1818
    • /
    • 2006
  • In present, most of metallic structures (gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway in Seoul and Pusan.In this case, subway system make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential, amplitude of stray current, point of source of stray current and so on. In this paper, results of development about Wireless Remote Monitoring and Control System on Underground Pipeline in Stray Current Conditions are presented. And also field test data should be reporting.

  • PDF

Beta-spectra for the Radionuclides in Medicine

  • Yi, Chul-Young;Kim, Kyung-Hwa;Park, Kyung-Bae;Han, Hyon-Soo;Jun, Jae-Shik;Chai, Ha-Seok
    • 한국의학물리학회지:의학물리
    • /
    • 제9권1호
    • /
    • pp.37-46
    • /
    • 1998
  • Beta-particle energy distributions of the radionuclides in medicine are calculated for the medical physics applications. The radial component solutions of Dirac wave equations are evaluated for a point-nucleus un screened Coulomb potential. The WKB method is employed to correct the screening due to the orbital-electron cloud. Fierz interference terms are ignored. The radionuclides considered are $\^$32/P, $\^$90/Y, $\^$131/I, $\^$166/Ho, $\^$192/Ir, $\^$198/Au, $\^$153/Sm, $\^$169/Er and $\^$188/Re. A total of 9 beta-spectra for the radionuclides, currently in domestic use or potential use in the near future, are calculated with enough accuracy and presented in graphs and tables.

  • PDF

교류전기철도 매설접지방식에서의 레일전위 해석 (Analysis on Rail Potential on the AC Electric Railway Grounding System)

  • 창상훈;오광해;김주락;최규형;김정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.446-448
    • /
    • 2001
  • Railway electrification results in Electromagnetic Interference, which affects a life and a equipment. Therefore, a plan against EMI must be considered. This study presents accurate simulation to examine a reason rail potential rise and how to design ground connection and draw up a plan of an optimal buried grounding system according to section.

  • PDF

Graphene field-effect transistor for radio-frequency applications : review

  • Moon, Jeong-Sun
    • Carbon letters
    • /
    • 제13권1호
    • /
    • pp.17-22
    • /
    • 2012
  • Currently, graphene is a topic of very active research in fields from science to potential applications. For various radio-frequency (RF) circuit applications including low-noise amplifiers, the unique ambipolar nature of graphene field-effect transistors can be utilized for high-performance frequency multipliers, mixers and high-speed radiometers. Potential integration of graphene on Silicon substrates with complementary metal-oxide-semiconductor compatibility would also benefit future RF systems. The future success of the RF circuit applications depends on vertical and lateral scaling of graphene metal-oxide-semiconductor field-effect transistors to minimize parasitics and improve gate modulation efficiency in the channel. In this paper, we highlight recent progress in graphene materials, devices, and circuits for RF applications. For passive RF applications, we show its transparent electromagnetic shielding in Ku-band and transparent antenna, where its success depends on quality of materials. We also attempt to discuss future applications and challenges of graphene.

지하철과 전력선의 누설전류 측정을 위한 저장형 데이터 계측장치 (DATA LOGGER APPARATUS FOR MEASUREMENT STRAY CURRENT OF SUBWAY AND POWER LINE)

  • 배정효;하윤철;하태현;이현구;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.731-734
    • /
    • 2003
  • In present, most of metallic structures(gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway and power line in seoul. Moreover subway system and power line make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential, amplitude of stray current, point of source of stray current and so. In this paper, results of development about data logger apparatus for measurement stray current of subway and power line are presented.

  • PDF

Hydrodynamic characteristics of a fixed semi-submersible platform interacting with incident waves by fully nonlinear method

  • Zhang, Zi-Lin;Yuan, Hong-Tao;Sun, Shi-Li;Ren, Hui-Long
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제13권1호
    • /
    • pp.526-544
    • /
    • 2021
  • Based on the potential flow theory, a fully nonlinear numerical procedure is developed with boundary element method to analyze the interaction between a fixed semi-submersible platform and incident waves in open water. The incident wave is separated from the scattered wave under fully nonlinear boundary conditions. The mixed Euler-Lagrangian method is used to capture the position of the disturbed wave surface in local coordinate systems. The wave forces exerted on an inverted conical frustum are used to ensure the accuracy of the present method and good agreements with published results are obtained. The hydrodynamic characteristics of the semi-submersible platform interacting with regular waves are analyzed. Pressure distribution with time and space, tension and compression of the platform under wave action are investigated. 3D behaviors of wave run-ups are predicted. Strong nonlinear phenomena such as wave upwelling and wave interference are observed and analyzed.