• 제목/요약/키워드: Potential interference

검색결과 321건 처리시간 0.027초

접지전류의 주파수에 따른 수직 접지전극 주변에서 전위간섭 영향 분석 (An Analysis of Potential Interference Effects in the Vicinity of Ground Rod Depending on Frequency of Ground Currents)

  • 이복희;조용승;최종혁;양순만
    • 조명전기설비학회논문지
    • /
    • 제25권12호
    • /
    • pp.88-93
    • /
    • 2011
  • When the ground current is injected into the adjacent ground electrode, the potential interference is caused between ground electrodes, the ground potential interferences have been largely studied with power frequency fault currents. Many attempts to find the frequency-dependent grounding impedance report that the high frequency grounding impedance is very different with the ground resistance. This paper presents experimental data on the frequency-dependent potential interference effects in the vicinity of ground rod. The ground potential rises around the test ground rod of 4 or 6[m] were measured and discussed. As a result, the ground potential rises and potential interference factor are decreased with decreasing the grounding impedance. It was found that the lowering of grounding impedance is critical to reduce the ground potential interference effects.

Research on Assessment of Potential Interference between Individual Grounding Electrodes Using an Electrolytic Tank Modeling Method

  • Gil, Hyoung-Jun;Kim, Dong-Ook;Choi, Chung-Seog
    • 조명전기설비학회논문지
    • /
    • 제22권3호
    • /
    • pp.27-33
    • /
    • 2008
  • This paper deals with the assessment of potential interference between individual grounding electrodes using an Electrolytic Tank Modeling method. When a test current was passed through a grounding electrode, potential rise was measured and analyzed using an electrolytic tank in real time. In order to analyze the potential interference between grounding electrodes, a reduced scale modeling method was studied. Potential interference between isolated grounding electrodes was evaluated as a function of the separation distance between grounding electrodes and the configuration of grounding electrode to be induced. It was found that the separation distance between grounding electrodes was a major factor in reducing the potential interference.

접지극의 전위간섭 (Potential Interference between the Earth Electrode)

  • 김주찬;김성삼;고희석
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.48-52
    • /
    • 2004
  • Recently, there are many electricity, electronics, and communication equipment which need to earthing in the building. When electric current flows into a certain earthing system in the same building, the potential of other earthing system rises. This potential interference repuire surface potential of electrodes by electrode shape. In this paper basic formula is deduced on the basis of both electrodes surface potential of earth electrode as a source of the potential interference and earth electrode which receive the potential interference. The degree of potential interference as multiple earth electrode is verified the simulated results by means of the simple model in advance.

  • PDF

복수접지극의 전위간섭 (Potential Interference of Plural Grounding Electrodes)

  • 김주찬;최종규;이충식;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.27-29
    • /
    • 2004
  • Recently, there are many electricity, electronics, and communication equipment which need to earthing in the building. When electric current flows into a certain earthing system in the same building, the potential of other earthing system rises. This potential interference require surface potential of electrods by electrode shape. In this paper basic formula is deduced on the basis of both electrodes surface potential of earth electrode as a source of the potential interference and earth electrode which receive the potential interference. The degree of potential interference as multiple earth electrode is verified the simulated results by means of the simple model in advance.

  • PDF

ETM 기법을 이용한 접지전극의 전위간섭 평가 (Assessment of Potential Interference between Grounding Electrodes Using ETM Method)

  • 길형준;김동욱;김동우;이기연;최충석
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 추계학술대회 논문집
    • /
    • pp.333-336
    • /
    • 2007
  • This paper deals with assessment of potential interference between grounding electrodes using ETM(Electrolytic Tank Modeling) method. When a test current flowed through grounding electrode, potential rise was measured and analyzed using an electrolytic tank in real time. In order to analyze the potential interference between grounding electrodes, ETM method was studies. Potential interference between isolated grounding electrodes was evaluated as functions of the separation distance between grounding electrodes and the configuration of grounding electrode to be induced. It was found that the separation distance between grounding electrodes in reducing the potential interference was a major factor.

  • PDF

격자형 접지전극의 전위간섭 (The Potential Interference of the Grounding Grids)

  • 이복희;이태형;이수봉;정현욱;길형준
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 학술대회 논문집
    • /
    • pp.261-263
    • /
    • 2005
  • This paper presents the potential interferences between various grounding electrodes. The ground potential rise and potential interference coefficient between grounding grid and ground rod were calculated. The potential rise and potential interference coefficient strongly depend on the distance between grounding electrodes.

  • PDF

봉상 접지전극-수평매설 접지전극 상호간의 전위간섭 (The Potential Interference between Ground Rod and Counterpoise)

  • 이복희;이수봉;정동철
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.351-354
    • /
    • 2006
  • This paper deals with the potential interferences between ground rod and counterpoise. The ground potential rise and coefficient of potential interference were measured by using the hemispherical water tank grounding simulator and calculated from CDEGS program as functions of the configuration and size of grounding electrodes and the distance between grounding electrodes. The ground potential un and potential interference coefficient strongly depend on the distance between grounding electrodes, the arrangement and size of grounding electrodes.

  • PDF

30MHz 이하 무선 서비스에 대한 전자기기의 잠재적 간섭 영향 (Potential Interference of Electric Equipments on Radio Service below 30MHz)

  • 윤혜주;이일규
    • 한국인터넷방송통신학회논문지
    • /
    • 제13권2호
    • /
    • pp.269-273
    • /
    • 2013
  • 본 논문은 대표적인 전파응용기기로 알려진 PDP(Plasma Display Panel) TV와 RF(Radio Frequency) 전구가 30MHz 이하 무선 서비스에 대한 전자기기의 잠재적 간섭 영향을 분석한 것이다. PDP TV와 RF 전구의 방사 크기를 전자파무반사실에서 측정하였고 이를 바탕으로 다수의 간섭 신호가 존재하는 경우에 결합된 간섭신호의 크기를 계산하였다. 분석 결과, 간섭원의 수에 따라 결합된 간섭 신호의 크기가 증가되는 경향을 확인하였다. 실험을 통해 얻어진 전자기기의 방사 측정값과 CISPR(International Special Committee on Radio Interference) 11의 제한치를 비교함으로 30MHz 이하의 무선 서비스에 대한 전자기기 간섭 잠재성을 확인하였다.

각판상전극의 접지저항에 관한 연구 (Research on Grounding Resistance for the Grounding Plate Electrodes)

  • 고희석;신수한;김주찬;최종규
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.111-114
    • /
    • 2004
  • There are many electricity, electronics, and communication equipment which need to Grounding in the building. When electric current flows into a certain Grounding system in the same building, the potential of other Grounding system rises. This potential interference repuire surface potential of electrods by electrode shape. In this paper basic formula is deduced on the basis of both electrodes surface potential of Grounding electrode as a source of the potential interference and Grounding electrode which receive the potential interference. The degree of potential interference as multiple Grounding electrode is verified the simulated results by means of the simple model in advance.

  • PDF

복수접지극의 변화에 따른 전극의 X축 간섭계수 (Interference Coefficient of X axis for Electrodes using Variation of Plural Earth Electrodes)

  • 김성삼;김주찬;송원표;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.449-451
    • /
    • 2004
  • In the building, there are a lot of electricity, electrodes, and communication equipment. Many of those equipment needs to earthing. Naturally, the earth electrodes are constructed in the site of a building. In such a situation, when electric current flows into a certain earthing system the potential of other earthing systems rises. That is, the potential interference will take place between the earth electrodes. The conventional study has been considered by only the relation of the distance between the earth electrodes using the potential distribution formula of earth surface. However, it is necessary to inquire strictly, taking the surface potential of electrodes by electrode form into consideration. In this paper, basic formula is deduced on the basis of both electrodes surface potential of earth electrode as a source of the potential interference and earth electrode which receives the potential interference.

  • PDF