• 제목/요약/키워드: Potential Rise

Search Result 666, Processing Time 0.028 seconds

Analysis of the Ground Surface Potential Rise using a Hemisphere-Shaped Test Model (반구형 실험모델을 이용한 대지표면 전위상승의 분석)

  • Yoo, Jae-Duk;Cho, Yong-Seung;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.208-213
    • /
    • 2010
  • This paper deal with an analysis of the ground surface potential profiles using a hemispherical scaled-model. Because it is very difficult to draw valid conclusions concerning a general grounding problem from actual field data, scale model tests can be used to determine the ground surface potential profile around the grounding electrodes according to the configuration of grounding electrodes. In this work, a hemispherical vessel with a diameter of 1,100 [mm] was employed to simulate uniform soil and CDEGS program was employed to compare the measured and simulated results. As a result, the ground surface potential around the grounding electrode was significantly raised and the ground surface potential at the just upper point of ground electrode particularly was higher than other points. The ground surface potential of counterpoise was higher than other grounding electrodes such as mesh and grounding rods and the ground surface potential strongly depends on the frequency responses of grounding electrodes. Also the results measured with the small-sized model were in reasonably agreement with the data obtained from simulation.

A Study on the Generation of the Earth Potential and Communication Line Noise (대지전위와 통신회선 잡음.발생에 대한 고찰)

  • Yeo, Sang-Kun;Park, Chan-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.181-189
    • /
    • 2007
  • This paper presents a experimental evidence of the generation of the earth potential and communication line noise from the electric railway. There is a critical measurement err in case of measuring the electrical power induced noise voltage and degree of cable balance in the field of earth potential generated. As a results, it has been found that the conventional cable has more noise immunity than shielded cable near the railway where the earth current flows through the sheath layer.

Induced Potential Rises between the Neigboring Grounding Electrodes due to the Impulse Voltages (임펄스전압에 의한 근접 접지전극사이의 유도전위상승)

  • Lee, B.H.;Eom, J.H.;Lee, S.C.;Jeon, D.K.;Lee, K.O.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1741-1743
    • /
    • 2001
  • This paper presents the induced ground potential rise distributions on several ground electrodes buried nearby. These experiments were conducted with the impulse currents as a function of the ground electrodes types and distances from the current injection point. The ground potential is significantly induced in the vicinity of ground electrodes, and the induced ground potential rises can caused unwanted erratic operation of electronic device.

  • PDF

Effective Impulse Impedances of Deeply Driven Grounding Electrodes

  • Lee, Bok-Hee;Jeong, Dong-Cheol;Lee, Su-Bong;Chang, Keun-Chul
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.5
    • /
    • pp.207-214
    • /
    • 2004
  • This paper presents the characteristics of transient and effective impulse impedances for deeply driven grounding electrodes used in soil with high resistivity or in downtown areas. The laboratory test associated with the time domain performance of grounding piles subjected to a lightning stroke current has been carried out using an actual-sized model grounding system. The ground impedances of the deeply driven ground rods and grounding pile under impulse currents showed inductive characteristics, and the effective impulse ground impedance owing to the inductive component is higher than the power frequency ground impedance. Both power frequency ground impedance and effective impulse ground impedance decrease upon increasing the length of the model grounding electrodes. Furthermore, the effective impulse ground impedances of the deeply driven grounding electrodes are significantly amplified in impulse currents with a rapid rise time. The reduction of the power frequency ground impedance is decisive to improve the impulse impedance characteristics of grounding systems.

DESIGN OF OPTIMUM GROUNDING BY THE RESISTIVITY ANALYSIS OF MULTI-LAYERED SUBSURFACE (다층 대지비저항 해석에 의한 최적 접지설계)

  • HyoungSooKim
    • Journal of the Korean Geophysical Society
    • /
    • v.6 no.3
    • /
    • pp.179-188
    • /
    • 2003
  • The object of grounding of electrical facility is to protect human and machine damage from the power supply interruption high voltage by use of the accident current dissipating into the ground. Generally, it is not easy to make suitable ground design for inhomogeneous subsurface geology and the variability of accident current in magnitude and duration time. To make efficient ground, ground potential rise must be controlled in the way of overall lowering and evenness. This study shows the case of optimized ground design by use of subsurface resistivity structure from electrical soundings.

  • PDF

Adsorbed Water in Soil a Interpreted by Its Potentials Based on Gibbs Function (Gibbs 함수의 포텐샬로 해석한 토양 흡착수)

  • 오영택;신제성
    • Journal of the Mineralogical Society of Korea
    • /
    • v.9 no.1
    • /
    • pp.17-25
    • /
    • 1996
  • Usual experimental adsorption isotherms as a function of relative humidity were constructed from adsorbed water contents in soils, which were kept more than 2 days in vacuum desiccators with constant humidities controlled by sulfuric acids of various concentrations. From the experimental data, the adsorption surface areas were calculated on the basis of the existing adsorption theory, such as Langmuir, BET, and Aranovich. Based on the Gibbs function describing chemical potential of perfect gas, the relative humidities in the desiccators were transformed into their chemical potentials, which were assumed to be the same as the potentials of equilibratedly adsorbed water in soils. Moreover, the water potentials were again transformed into the equivalent capillary pressures, heads of capillary rise, and equivalent radius of capillary pores, on the basis of Laplace equation for surface tension pressure of spherical bubbles in water. Adsorption quantity distributions were calculated on the profile of chemical potentials of the adsorbed water, equivalent adsorption and/or capillary pressures, and equivalent capillary radius. The suggested theories were proved through its application for the prediction of temperature rise of sulfuric acid due to hydration heat. Adsorption heat calculated on the basis of the potential difference was dependant on various factors, such as surface area, equilibrium constants in Langumuir, BET, etc.

  • PDF

Measurement and Analysis of Risk Voltages by Various Current Sources in Grounding System (다양한 전류원에 대한 접지시스템의 위험전압 측정과 분석)

  • Kil, Gyung-Suk;Moon, Byoung-Doo;Kim, Hwang-Kuk;Park, Dae-Won;Gil, Hyoung-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.113-118
    • /
    • 2009
  • Grounding systems set the reference voltage level of electric circuits and suppress the Ground Potential Rise (GPR) by flowing fault currents to the ground safely. There are several parameters which evaluate the performance of grounding systems as ground resistance, touch voltage and step voltage. The touch and step voltages, which is called "risk voltage", are especially important to ensure the safety of human body. This paper dealt with the influence of current sources with the different frequency components on the touch and the step voltages. Three types of current sources as commercial frequency, square wave, and surge with the fast risetime of $50\;ns{\sim}500\;ns$ were used to analyze the risk voltages in a grounding system. The risk voltages showed remarkable difference in the same current amplitude depending on the current sources, and increased linearly with the current amplitude in the same current source. From the experimental results, it was confirmed that the risk voltages can be evaluated by a small current application in large-scale grounding systems and the possible largest risk voltage can be calculated by a surge current with the risetime of 200 ns or a current source with the same frequency component as the surge current.

Analysis of Conductive Interference nearby High Voltage Power Lines under Fault Condition (송전선로 지락시 철탑 인근의 대지전위간섭 해석모델)

  • Choi, J.K.;Lee, W.K.;Ryu, H.Y.;Shin, B.H.;Son, K.M.;Kim, T.Y.;Hwang, G.C.
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.466-467
    • /
    • 2008
  • In case of a line-to-ground fault at transmission lines, a portion of fault current will flow into the earth through the footings of the faulted tower causing electrical potential rise nearby the faulted tower footings. In this situation, any buried pipelines or structures nearby the faulted tower can be exposed to the electrical stress by earth potential rise. Although many research works has been conducted on this phenomena, there has been no clear answer of the required separation distance between tower footings and neary buried pipeline because of its dependancy on the soil electrical charactersics of the concerned area and the faulted system.

  • PDF

Analysis of Risk Voltage for Grounding Electrode by Injection of Earth Leakage Current

  • Gil, Hyoung-Jun;Kim, Dong-Woo;Kim, Dong-Ook;Lee, Ki-Yeon;Moon, Hyun-Wook;Kim, Hyang-Kon;Kil, Gyung-Suk
    • International Journal of Safety
    • /
    • v.8 no.2
    • /
    • pp.9-14
    • /
    • 2009
  • This paper describes analysis of risk voltage for grounding electrode where earth leakage current is injected. To assess risk voltage of grounding electrode, the grounding simulator and CDEGS program were used to obtain measured data and theoretical results of this study. The grounding simulator was composed of a hemispherical water tank, AC power supply, a movable potentiometer, and test grounding electrodes. The shapes of grounding electrode model was ground rod. The potential rise was measured by grounding simulator, and the touch and step voltages were computed by CDEGS program. As a consequence, the potential rise of ground rod abruptly decreases with increasing the distance from the grounding electrode to the point to be tested. The touch voltage above the ground rod was low, but the step voltage was high. The measured results were compared with the computer calculated data and were known in good agreement.

Upward Flame Spread for Fire Risk Classification of High-Rise Buildings

  • McLaggan, Martyn S.;Gupta, Vinny;Hidalgo, Juan P.;Torero, Jose L.
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.4
    • /
    • pp.299-310
    • /
    • 2021
  • External fire spread has the potential to breach vertical compartmentation and violate the fire safety strategy of a building. The traditional design solution to this has been the use of non-combustible materials and spandrel panels but recent audits show that combustible materials are widespread and included in highly complex systems. Furthermore, most jurisdictions no longer require detailing of spandrel panels under many different circumstances. These buildings require rapid investigation using rational scientific methods to be able to adequately classify the fire risk. In this work, we use an extensive experimental campaign of material-scale data to explore the critical parameters driving upward flame spread. Two criteria are outlined using two different approaches. The first evaluates the time to ignition and the time to burnout to assess the ability for a fire to spread, and can be easily determined using traditional means. The second evaluates the preheated flame length as the critical parameter driving flame spread. A wide range of cladding materials are ranked according to these criteria to show their potential propensity to flame spread. From this, designers can use conservative approaches to perform fire risk assessments for buildings with combustible materials or can be used to aid decision-making. Precise estimates of flame spread rates within complex façade systems are not achievable with the current level of knowledge and will require a substantial amount of work to make progress.