• Title/Summary/Keyword: Potential Interference

Search Result 325, Processing Time 0.024 seconds

Applications of fiber optic sensors for structural health monitoring

  • Kesavan, K.;Ravisankar, K.;Parivallal, S.;Sreeshylam, P.
    • Smart Structures and Systems
    • /
    • v.1 no.4
    • /
    • pp.355-368
    • /
    • 2005
  • Large and complex structures are being built now-a-days and, they are required to be functional even under extreme loading and environmental conditions. In order to meet the safety and maintenance demands, there is a need to build sensors integrated structural system, which can sense and provide necessary information about the structural response to complex loading and environment. Sophisticated tools have been developed for the design and construction of civil engineering structures. However, very little has been accomplished in the area of monitoring and rehabilitation. The employment of appropriate sensor is therefore crucial, and efforts must be directed towards non-destructive testing techniques that remain functional throughout the life of the structure. Fiber optic sensors are emerging as a superior non-destructive tool for evaluating the health of civil engineering structures. Flexibility, small in size and corrosion resistance of optical fibers allow them to be directly embedded in concrete structures. The inherent advantages of fiber optic sensors over conventional sensors include high resolution, ability to work in difficult environment, immunity from electromagnetic interference, large band width of signal, low noise and high sensitivity. This paper brings out the potential and current status of technology of fiber optic sensors for civil engineering applications. The importance of employing fiber optic sensors for health monitoring of civil engineering structures has been highlighted. Details of laboratory studies carried out on fiber optic strain sensors to assess their suitability for civil engineering applications are also covered.

Anodic Stripping Voltammetric Detection of Arsenic(III) at Platinum-Iron(III) Nanoparticle Modified Carbon Nanotube on Glassy Carbon Electrode

  • Shin, Seung-Hyun;Hong, Hun-Gi
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.11
    • /
    • pp.3077-3083
    • /
    • 2010
  • The electrochemical detection of As(III) was investigated on a platinum-iron(III) nanoparticles modified multiwalled carbon nanotube on glassy carbon electrode(nanoPt-Fe(III)/MWCNT/GCE) in 0.1 M $H_2SO_4$. The nanoPt-Fe(III)/MWCNT/GCE was prepared via continuous potential cycling in the range from -0.8 to 0.7 V (vs. Ag/AgCl), in 0.1 M KCl solution containing 0.9 mM $K_2PtCl_6$ and 0.6 mM $FeCl_3$. The Pt nanoparticles and iron oxide were co-electrodeposited into the MWCNT-Nafion composite film on GCE. The resulting electrode was examined by cyclic voltammetry (CV), scanning electron microscopy (SEM), and anodic stripping voltammetry (ASV). For the detection of As(III), the nanoPt-Fe(III)/MWCNT/GCE showed low detection limit of 10 nM (0.75 ppb) and high sensitivity of $4.76\;{\mu}A{\mu}M^{-1}$, while the World Health Organization's guideline value of arsenic for drinking water is 10 ppb. It is worth to note that the electrode presents no interference from copper ion, which is the most serious interfering species in arsenic detection.

Development of Optical Pickup for ElectroAcoustic Guitar (일렉트로어쿠스틱 기타용 광 픽업의 개발)

  • Shin, Bong-Hi;Park, Young-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.5
    • /
    • pp.417-422
    • /
    • 2014
  • A guitar pickup is a transducer that converts string vibration to an electrical signal. The magnetic and piezo pickups are the most commonly used for the respective electric and electroacoustic guitars. The magnetic pickups are prone to magnetic interference between the steel strings and permanent magnets, while the piezo ones are not free from signal inference between the strings. Thus, this paper presents the development of an optical pickup for the electroacoustic guitar. The proposed optical pickup has the top-to-bottom structure. It uses two of Infrared (IR) Light Emitting Diode (LED) and one photodetector. The developed optical pickup is subjected to the evaluation with commonly used piezoelectric pickup. It becomes obvious that SNR with the optical pickup is increased by 45 percent in average, compared with the piezoelectric pickup. It can be concluded that the developed optical pickup has a potential to be applied to the acoustic guitar.

Performance Characteristics of Interference-Type Floating Breakwaters with Various two-dimensional Sectional Shapes (간섭식 부방파제의 2차원 단면형상 소파성능)

  • Song, Mu-Seok;Kim, Do-Young
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.8 no.2
    • /
    • pp.67-73
    • /
    • 2005
  • The characteristics of the floating breakwater is briefly reviewed and their performance is numerically investigated. The numerical scheme is a boundary integral method for inviscid potential flows, and various two-dimensional floating breakwater modules are studied focusing on the transmission coefficient. The general characteristics of pontoons is studied as function of mooring line stiffness, mass moment inertia and draft. Trapezoidal-, hat- and table-shape cross-sections are also studied with varying shape-parameters. The efficiency varies with changes in each shape-parameter and for some cases satisfying tranquility can be expected with even longer waves.

  • PDF

An Antioxidative and Antiinflammatory Agent for Potential Treatment of Osteoarthritis from Ecklonia cava

  • Shin Hyeon-Cheol;Hwang Hye Jeong;Kang Kee Jung;Lee Bong Ho
    • Archives of Pharmacal Research
    • /
    • v.29 no.2
    • /
    • pp.165-171
    • /
    • 2006
  • Osteoarthritis is thought to be induced by the ageing-related loss of homeostatic balance between degeneration and repair mechanism around cartilage tissue in which inflammatory mediators such as reactive oxygen species, cytokines and prostaglandins are prone to overproduction under undesirable physiological conditions. Phlorotannins are unique polyphenolic compounds bearing dibenzo-1,4-dioxin skeleton which are not found in terrestrial plants but found only in some brown algal species such as Ecklonia and Eisenia families. Phlorotanninrich extracts of Ecklonia cava including LAD103 showed significant antioxidant activities such as DPPH radical scavenging, ferric ion reduction, peroxynitrite scavenging, and inhibition of LDL oxidation, indicating their possible antioxidative interference both in onset and downstream consequences of osteoarthritis. LAD103 also showed significant down regulation of $PGE_2$ generation in LPS-treated RAW 246.7 cells, and significant inhibition of human recombinant interleukin-$1{\alpha}$-induced proteoglycan degradation, indicating its beneficial involvement in pathophysiological consequences of osteoarthritis, the mechanism of which needs further investigation. Since LAD103 showed strong therapeutic potentials in arthritic treatment through several in vitro experiments, it is highly encouraged to perform further mechanistic and efficacy studies.

NOMA Transceiver Design for Highway Transportation in Mobile Hotspot Networks

  • Hui, Bing;Kim, Junhyeong;Choi, Sung-Woo;Chung, Heesang;Kim, Ilgyu;Lee, Hoon
    • ETRI Journal
    • /
    • v.38 no.6
    • /
    • pp.1042-1051
    • /
    • 2016
  • The mobile hotspot network (MHN), which is capable of providing a data rate of gigabits per second at high speed, is considered a potential use case of the future enhanced mobile broadband for 5G. Because a unidirectional network deployment has been considered for an MHN, non-orthogonal multiple access (NOMA) can be employed to improve the system performance. For a practical implementation of NOMA under an MHN highway scenario where multiple pieces of MHN terminal equipment are served through the same beam simultaneously, a NOMA transceiver is proposed in this paper. For the NOMA transmitter, Gray-coded QAM constellation mapping is extended to arbitrary modulation order q. For the NOMA receiver, successive interference cancellation (SIC) is no longer necessary, and instead, a parallel demodulation is proposed. The numerical and simulation results suggest that the proposed NOMA transceiver outperforms the conventional NOMA SIC receiver and can be flexibly used for an MHN highway scenario.

Interference effect by electric utilities at electric resistivity Survey of fill dam (필댐의 전기비저항 탐사시 전기매체에 의한 영향 분석 연구)

  • Kim, Jae-Hong;Shin, Dong-Hoon;Im, En-Sang
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1037-1040
    • /
    • 2009
  • Using much most electricity electric resistivity survey by nondestructiveness inquiry enforcement design of country base equipment business and facilities preservation administration dimension electric resistivity survey sends and cause much effects in survey believability by electricity medium of survey personality survey contiguity that grasp base special quality by potential difference flowing current artificially in base. Is item that enforce in most in-suite although when make electric resistivity survey until present, electricity medium or effect research by electricity origination was gone much. There is shortcoming that must be difficult to know correct underground utilities establishment state in-suite in this research and do comparison examination running parallel drilling investigation to heighten believability of electric resistivity survey. Did to dam that censure data that regulate grading from construction and is censure construction which can know correctly interior base situation comparatively to electricity medium of interior and electricity eruption won of contiguity and base condition (base rock).

  • PDF

Reduction of biofouling using vanillin as a quorum sensing inhibitory agent in membrane bioreactors for wastewater treatment

  • Nam, AnNa;Kweon, JiHyang;Ryu, JunHee;Lade, Harshad;Lee, ChungHak
    • Membrane and Water Treatment
    • /
    • v.6 no.3
    • /
    • pp.189-203
    • /
    • 2015
  • Membrane biofouling impedes wide application of membrane bioreactor (MBR) for wastewater treatment. Recently, quorum sensing (QS) mechanisms are accounted for one of major mechanisms in biofouling of MBRs. In this study, vanillin was applied to investigate reduction of biofouling in MBRs. MBR sludge was analyzed to contain QS signal molecules by cross-feeding biosensor assay and HPLC. In addition, the inhibitory activity of vanillin against bacterial quorum sensing was verified using an indicator strain CV026. The vanillin doses greater than 125 mg/L to 100 mL of MBR sludge showed 25% reduction of biofilm formed on the membrane surfaces. Two MBRs, i.e., a typical MBR as a control and an MBR with vanillin, were operated. The TMP increases of the control MBR were more rapid compared to those of the MBR with the vanillin dose of 250 mg/L. The treatment efficiencies of the two MBRs on organic removal and MLSS were maintained relatively constant. Extracellular polymeric substance concentrations measured at the end of the MBR operation were 173 mg/g biocake for the control MBR and 119 mg/g biocake for the MBR with vanillin. Vanillin shows great potential as an anti-biofouling agent for MBRs without any interference on microbial activity for wastewater treatment.

Bioinformatics Approach to Direct Target Prediction for RNAi Function and Non-specific Cosuppression in Caenorhabditis elegans (생물정보학적 접근을 통한 Caenorhabditis elegans 모델시스템의 생체내 RNAi 기능예측 및 비특이적 공동발현억제 현상 분석)

  • Kim, Tae-Ho;Kim, Eui-Yong;Joo, Hyun
    • KSBB Journal
    • /
    • v.26 no.2
    • /
    • pp.131-138
    • /
    • 2011
  • Some computational approaches are needed for clarifying RNAi sequences, because it takes much time and endeavor that almost of RNAi sequences are verified by experimental data. Incorrectness of RNAi mechanism and other unaware factors in organism system are frequently faced with questions regarding potential use of RNAi as therapeutic applications. Our massive parallelized pair alignment scoring between dsRNA in Genebank and expressed sequence tags (ESTs) in Caenorhabditis elegans Genome Sequencing Projects revealed that this provides a useful tool for the prediction of RNAi induced cosuppression details for practical use. This pair alignment scoring method using high performance computing exhibited some possibility that numerous unwanted gene silencing and cosuppression exist even at high matching scores each other. The classifying the relative higher matching score of them based on GO (Gene Ontology) system could present mapping dsRNA of C. elegans and functional roles in an applied system. Our prediction also exhibited that more than 78% of the predicted co-suppressible genes are located in the ribosomal spot of C. elegans.

Optimal Electrode Selection for Detection of Human Leg Movement Using Bio-Impedance (생체 임피던스를 이용한 인체 하지운동 출을 위한 최적 전극위치 선정)

  • 송철규;윤대영;이동헌;김승찬;김덕원
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.8
    • /
    • pp.506-509
    • /
    • 2003
  • This paper describes the possibility of analyzing gait pattern from the changes of the lower leg electrical impedance. This impedance was measured by the four-electrode method. Two current electrodes were applied to the thigh, knee, and foot., and two potential electrodes were applied to the lateral, medial, and posterior position of human leg. The correlation coefficients of the joint angle and the impedance change from human leg movement was obtained using a electrogoniometer and 4ch impedance measurement system developed in this study. We found the optimal electrode position for knee and ankle joint movements based on high correlation coefficient, least interference, and maximum magnitude of impedance change. The correlation coefficients of the ankle, knee, and the hip movements were -0.913, 0.984 and 0.823, respectively. From such features of the human leg impedance, it has been made clear that different movement patterns exhibit different impedance patterns and impedance level. This system showed feasibility that lower leg movement could be easily measured by impedance measurement system with a few skin-electrodes.