• 제목/요약/키워드: Potable

검색결과 212건 처리시간 0.023초

진공청소기를 이용한 휴대용 유출기름 회수기의 개발 (Development of a Potable Skimmer with a Vacuum Cleaner)

  • 박외철
    • 한국안전학회지
    • /
    • 제10권1호
    • /
    • pp.41-49
    • /
    • 1995
  • A potable oil skimmer is in need to remove spilt oils before they spread, which is applicable to various situations of oil viscosity, spill location, current, tides, waves and wind. An air suction skimmer was selected to be developed because of its advantages such as simple structure, excellent transportability, and easy deployment. A prototype operating by a commercial vacuum cleaner was fabricated. Tests of the skimmer showed good performance : the maximum suction rate of water and suction head were 18㎥/h and 2.7m, respectively.

  • PDF

A STUDY ON THE ELIMINATION OF FLUORIDE IN A HOT SPRING WATER

  • Lee, Hyeon-Ki;Kim, Hwan-Gi
    • Environmental Engineering Research
    • /
    • 제11권2호
    • /
    • pp.77-83
    • /
    • 2006
  • The hot spring water of the north Jeonla province such as Wanggung, Jookrim, Seokjung, and Hwasim, has fluoride concentration of 3.9 mg/L, 12.7 mg/L, 1.9 mg/L, and 6.3 mg/L, respectively. These figures fairly exceed the Korean and WHO standard for potable water, which is 1.5 mg/L. Therefore, in this study, research on elimination of fluoride in a hot spring water of Jookrim region, which has the highest level of fluoride concentration level in the north Jeonla province, was carried out. In analysis of Jookrim hot spring water according to the water quality standard for potable water, pH was very high at 9.25 and the concentration of fluoride was 10 times higher than the standard at 18.2 mg/L. Other measurements were within the standard or not detected. After injecting 10g of activated carbon for elimination of fluoride, the fluoride concentration was measured at 13.5 mg/L, and when 70mL or more of alum 10 g/L solution was injected, the concentration was measured at 2.8 mg/L, and injecting 3g of lime was measured at 9 mg/L. Alum showed the best elimination performance among all individual injections. Injection of 25 mL of activated carbon and 100 mL of alum solution together reduced the fluoride concentration down to 1.3 mg/L, which is under the potable standard. Injection of lime 1g and 75 mL of alum 10 g/L solution together reduced fluoride concentration to 4.1 mg/L. From the modifying HRT, by using ion exchange resin column, the pH was stabilized when HRT was Imin and showed range of $6.7{\sim}7.8$. The fluoride concentration reduced gradually as the HRT increased, and satisfied the potable standard when HRT passed 6 min, and after 30 min HRT, the concentration of fluoride was 0.05 mg/L: almost eliminated.

Municipal wastewater reclamation for non-potable use using hollow- fiber membranes

  • Waghmare, Sujata;Masid, Smita;Rao, A. Prakash;Roy, Paramita;Reddy, A.V.R.;Nandy, T.;Rao, N.N.
    • Membrane and Water Treatment
    • /
    • 제1권3호
    • /
    • pp.207-214
    • /
    • 2010
  • Approximately 80% of water used in urban areas reappears as municipal wastewater (MWW). Reclamation of MWW is an attractive proposition under the present scenario of water stressed cities in India. In this paper, we attempted to reclaim MWW using lab-scale hollow- fiber (HF) membrane modules for possible reuse in non-potable applications. Experiments were conducted to evaluate the efficiency of virgin HF ($M_1$) and modified HF ($M_2$) modules. The $M_2$ module consists of HF modified with a skin layer formed through interfacial polymerization of m-phenylenediamine with trimesoyl chloride (MPD-TMC). The molecular weight cut-off (MWCO) of $M_1$ was 44000 g/mol and that of $M_2$ 10000 -14000 g/mol on the basis of rejection of polyethylene glycol. The combination of $M_1$ and $M_2$ modules was able to reduce concentrations of most of the pollutants in sewage and improved the treated water quality to the acceptable limits for non potable reuse applications. It is found that about 98-99% of the initial flux is recovered by the backwashing process, which was approximately two times in a month when operated continuously.

음용 지하수중에 분포하는 저영양세균의 계통학적 해석 (Phylogenetic Analysis of Oligotrophic Bacteria Found in Potable Groundwater)

  • 김인기;;황경숙
    • 미생물학회지
    • /
    • 제38권4호
    • /
    • pp.293-298
    • /
    • 2002
  • 다양한 농도의 영양배지(nutrient broth, NB; diluted nutrient broth, DNB)를 이용하여 음용 지하수중의 세균수를 계수한 결과, 통상농도의 NB배지에 비해 저영양배지인 DNB배지에서 2~50배 이상 높은 계수치를 나타내었다. 이와 같은 결과로부터 지하수중에는 NB배지에서는 중식이 현저히 저해되고 DNB배지에서만 중식이 가능한 저영양세균(oligotrophic bacteria)이 다수 분포하고 있음이라 판단되어 DNB배지로부터 184균주의 저영양세균을 분리하였다. 본 연구에서는 시판 음용수(CW, CJ )와 광천수(DPG, CJG1)에서 분리된 저영양세균 102 균주의 165 rDNA 염기서열을 결정하여 계통분류학적 특성을 검토한 결과 세 개의 주요한 계통군: Proteobacteria $\alpha$-subdivision (49 균주), $\beta$-subdivision (50 균주), $\gamma$-subdivision (3 균주)으로 분류되었다. Proteobacteria $\alpha$-subdivision에는 Afipia, Blastobacter, Bradyrhizobium, Caulobacter, Phenylobacterium, Rhizobioum, Sphingomonas가 포함되었으며, $\beta$-subdivision에는 Acidovorax, Azonexus, Ferribacterium, Janthinobacterium, Leptothrix, Polaromonas, Variovorax가 포함되었고, $\gamma$-subdivision에는 Rhodanobacter 등 다양한 계통군이 확인되었다.

목장지역 음용수의 위생학적 조사연구 (Studies on the Sanitation of Potable Water in Farm Areas)

  • 박석기;이강문;김성원;임봉택;박성배;이용욱
    • 한국환경보건학회지
    • /
    • 제19권1호
    • /
    • pp.44-50
    • /
    • 1993
  • In order to investigate the hygienic conditions of potable water in farm area, we examined the hygienic bacteriological and chemical tests of the 159 waters in the farm areas of Kwangjugun, Namyangju-gun, Yangpyung-gun Paju-gun and Hwasung-gun.The results were as follows: 1. Of the 159 waters, the average numbers of standard plate count and coliform were 920 $\pm$ 250ml and 450 $\pm$ 380/100 ml, respectively. The average pH was 6.74 $\pm$ 0.08, KMnO$_4$ consumption 4.18 $\pm$ 0.23 mg/l, turbidity 0.74 $\pm$ 0.08 degree, NH$_3$-N 0.07 $\pm$ 0.02 mg/l, NO$_3$-N 7.76 $\pm$ 0.48 mg/l, total hardness 101.3 $\pm$ 4.7mg/l, chlorine 18.6 $\pm$ 1.3mg/l, sulfate 12.9 $\pm$ 1.0 mg/l, lead 0.036 $\pm$ 0.003 mg/l, manganese 0.017 $\pm$ 0.003 mg/l, zinc 0.064 $\pm$ 0.005 mg/l, and copper 0.010 $\pm$ 0.001 mg/l, respectively. 2. Of the 159 waters, 84 samples (52.8%) were over 100 per ml of SPC or detected coliform per 100 ml water and 63 samples (39.6%) exceed over physicochemical limited criteria for potable water. NO$_3$-N was the primary item among excess contents of potable water in farm areas. 3. The contents of total hardness, chlorine and NO$_3$-N in Hwasung-gun were higher than those in the other regions, but the numbers of SPC and coliform in Yangpyung-gun and Namyangjugun were higher than those in the other regions. 4. The correlationships among many items were highly significant (SPC, Coliform, KMnO$_4$ consumption NH$_4$-N, NO$_3$-N, KMnO$_4$, Total hardness, Chlorine, Sulfate).

  • PDF

Community-acquired Legionnaires' Disease in a Newly Constructed Apartment Building

  • Ryu, Sukhyun;Yang, Kyungho;Chun, Byung Chul
    • Journal of Preventive Medicine and Public Health
    • /
    • 제50권4호
    • /
    • pp.274-277
    • /
    • 2017
  • Objectives: Legionnaires' disease (LD) is a severe type of pneumonia caused by inhalation of aerosols contaminated with Legionella. On September 22, 2016, a single case of LD was reported from a newly built apartment building in Gyeonggi province. This article describes an epidemiologic investigation of LD and identification of the possible source of infection. Methods: To identify the source of LD, we interviewed the patient's husband using a questionnaire based on the Legionella management guidelines from the Korea Centers for Disease Control and Prevention. Water samples from the site were collected and analyzed. An epidemiological investigation of the residents and visitors in the apartment building was conducted for 14 days before the index patient's symptoms first appeared to 14 days after the implementation of environmental control measures. Results: Legionella pneumophila serogroup 1 was isolated from the heated-water samples from the patient's residence and the basement of the apartment complex. Thirty-two suspected cases were reported from the apartment building during the surveillance period, yet all were confirmed negative based on urinary antigen tests. Conclusions: The likely source of infection was the building's potable water, particularly heated water. Further study of effective monitoring systems in heated potable water should be considered.

Comparative analysis for the corrosion susceptibility of copper alloys in sandy soil

  • Galai, Mouhsine;Benqlilou, Hanane;Touhami, Mohamed Ebn;Belhaj, Tounsi;Berrami, Khalifa;El Kafssaoui, Hassan
    • Environmental Engineering Research
    • /
    • 제23권2호
    • /
    • pp.164-174
    • /
    • 2018
  • Corrosion of copper alloys (copper, bronze and brass) in soil was evaluated at ambient temperature using various methods such as electrochemical impedance spectroscopy (EIS), polarization curves and Scanning Electron Microscopy (SEM) coupled with Energy Dispersive Spectroscopy microanalysis measurements. Three equivalent circuits were separately used to interpret the obtained impedance spectra. The EIS measurements indicated that the polarization resistance of all electrodes increases with increasing the immersion time. SEM showed a presence of three layers of corrosion products with various composition and morphology covering each electrode. In addition, it was found that at 20% of moisture content the $R_p$ values and the current density of all electrodes in the studied soil give the following order: copper > bronze > brass. Good consistency between the data obtained from EIS and PP measurements was observed.

전오존과 중공사형 한외여과막을 이용한 간이정수처리시스템에 관한 연구 (A Study on the Potable Water Purification System with Pre-Ozone and Ultra Filtration Membrane of Hollow Fiber Type)

  • 김민국;전양근
    • 한국물환경학회지
    • /
    • 제21권2호
    • /
    • pp.196-204
    • /
    • 2005
  • The objective of this study is to evaluate the possibility to apply pre-ozone and membrane system for drinking water. This system is improved in fouling control by pre-ozone system. It is composed of ultrafiltration hollow fiber type membrane and ozone reactor. The result of this study is that the flux is increased about 10.7% and decreased in TMP by the pre-ozone. Also, backwashing pressure decreased about 18%. The optimum concentration of residual ozone is 0.3~0.5 ppm. During the period, the recovery ratio of this system was turned out to be 90% as the flowrate of effluent is $67.1m^3/day$. When the TMP and backwashing pressure was $0.85kg/cm^2$ and $1.10kg/cm^2$, this system was stable without sudden fouling. Finally, the quality of effluent is satisfied the guidelines for potable water quality such as turbidity, color, E.coli, Mn, Al, Fe and so on.

휴대형 고전압 발생기에 대한 전자기기의 내성 (Immunity of Electronic Equipments Against Potable High Voltage Generator)

  • 이종익;여준호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2017년도 추계학술대회
    • /
    • pp.61-62
    • /
    • 2017
  • 본 연구에서는 최근 상용화된 휴대 가능한 소형 고전압 발생기의 주요 기능과 제원에 대해 소개한다. USB 킬러는 USB 포트를 사용하는 전자기기의 과전압 입력에 대한 보호회로를 시험하기 위한 용도로 개발되었다. USB 포트에서 공급되는 5 V 직류 전압을 발진기, 변압기, 배전압 정류회로를 통해 200 V이상의 충분히 높은 직류 전압으로 변환시킨다. 고용량 커패시터에 충전된 전압을 USB 포트를 통해 역방향으로 전자기기에 충격을 가하여 전자기기를 파괴하거나 보호회로를 시험 할 수 있다. USB 킬러는 개인이 쉽게 구입하여 전자기기를 시험해 볼 수 있다. 인터넷을 통해 공개된 시험 결과들과 실제 시험을 통해 확인된 결과들을 소개한다.

  • PDF