• Title/Summary/Keyword: Posture measuring

Search Result 177, Processing Time 0.024 seconds

A Work-related Musculoskeletal Disorder Risk Assessment Platform using Smart Sensor (스마트센서를 활용한 근골격계 질환 위험 평가 플랫폼)

  • Loh, Byoung Gook
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.3
    • /
    • pp.93-99
    • /
    • 2015
  • Economic burden of work-related musculoskeletal disorder(WMDs) is increasing. Known causes of WMDs include improper posture, repetition, load, and temperature of workplace. Among them, improper postures play an important role. A smart sensor called SensorTag is employed to estimate the trunk postures including flexion-extension, lateral bend, and the trunk rotational speeds. Measuring gravitational acceleration vector in the smart sensor along the tri-orthogonal axes offers an orientation of the object with the smart sensor attached to. The smart sensor is light in weight and has small form factor, making it an ideal wearable sensor for body posture measurement. Measured data from the smart senor is wirelessly transferred for analysis to a smartphone which has enough computing power, data storage and internet-connectivity, removing need for additional hardware for data post-processing. Based on the estimated body postures, WMDs risks can be conviently gauged by using existing WMDs risk assesment methods such as OWAS, RULA, REBA, etc.

Ergonomic Factors Assessment on Hand Tool Handle (수공구 손잡이의 인간공학적 요소 평가)

  • Yang Sung-Hwan;Cho Mun-Son;Kang Young-Sig
    • Journal of the Korea Safety Management & Science
    • /
    • v.8 no.1
    • /
    • pp.43-52
    • /
    • 2006
  • The goal of this study is to investigate the ergonomic factors in designing or selecting the hand tool handle. Electromyogram (EMG) were measured for various wrist postures and handle sizes under two loading conditions. Anthropometric data were measured and the correlation with EMG measurement data were analyzed. Investigations of this study show that wrist posture should be neutral for minimum muscle tension and optimum handle size can be found by measuring the EMG measurement data. It show that hand width and EMG measurement data is greatly correlated also. This study can be a guide of designing or selecting a hand tool, but further study with large sample sizes and various groups is needed for making general conclusion.

Clothing Pressure Sensation and Discomfort Experience of Skinny Jean (여대생의 스키니 진 착용 실태 및 주관적 압박감)

  • Na, Young-Joo;Lee, Dong-Wook
    • Korean Journal of Human Ecology
    • /
    • v.19 no.4
    • /
    • pp.655-665
    • /
    • 2010
  • This study analyzed the effects of skinny jean on women's health by questionnaire survey and measuring the pressure experienced under the clothing and participants' subjective view of the pressure level. The average size women in their 20s' waists is 26 inches and so three pairs of jeans were prepared and worn by 4 female participants. A survey was conducted to investigate how often participants wear skinny jeans and whether they had had any feelings of discomfort as a result of this. Participants responded that they hadexperienced middle to high levels of discomfort due to the high pressure inside skinny jeans. For the maximum value of clothing pressures, jean f2 at the part of buttocks showed $48.7gf/cm^2$. The pressure inside the clothing was found to be highest around the buttocks followed by the knees and finally the belly. The mean values of 7 measuring parts are different according to the jean type; f3 $20.8gf/cm^2$ > f2 $16.4gf/cm^2$ > f1 $15.5gf/cm^2$, which is corresponding to the order of pressure sensation, but not corresponding to the order of ease amount of clothing pattern: f2 > f3 > f1. Mean pressure values were also measured according to the body posture: they were found to by highest when sitting on a chair (21.3gf/$cm^2$), second highest when sitting on the floor ($19.2gf/cm^2$) and lowest when standing ($15.0gf/cm^2$). This is not always same to the order of participants subjective perceptions of the pressure, which is, they estimated pressure to be highest when sitting on the floor followed by sitting on a chair and lowest in a standing position.

Development of an Automatic Measuring Program for the Craniovertebral Angle Using Photographic Image (사진 영상을 이용한 머리척추각 자동 측정 프로그램 개발)

  • Soo-Young Ye;Jong-Soon Kim
    • PNF and Movement
    • /
    • v.22 no.1
    • /
    • pp.1-11
    • /
    • 2024
  • Purpose: The prevalent use of mobile devices may contribute to musculoskeletal disorders, such as forward head posture (FHP), among users. The measurement of the craniovertebral angle (CVA) using photographic images is frequently employed in assessing FHP. Although manual CVA measurement using photographic images is reliable in clinical settings, computer programs or mobile applications to support tele-physical therapy are not yet fully developed. Therefore, in the current study, we propose an automatic method for extracting CVA from photographic images of FHP subjects to facilitate tele-physical therapy. Methods: To develop the automatic CVA measuring computer program, photographic images were obtained from 10 FHP participants. The location information obtained from the markers attached to the tragus and the spinous process of the seventh cervical vertebra were used as coordinates. Using these coordinates, straight line 1 was generated by connecting the seventh spinous process of the cervical vertebra and the tragus, while straight line 2 was drawn parallel to the coordinate obtained from the seventh spinous process of the cervical vertebra. The arc tangent function was used to calculate the angle between the two straight lines. The automatic CVA measurement computer program utilizing photographic images was developed using MATLAB (ver. 2016b). Results: The results showed that the automatic CVA measurement computer program demonstrated stable repeatability and high accuracy. Conclusion: The proposed approach was able to automatically estimate the CVA using photographic images. The developed computer program can potentially be used for easier and more reliable clinical assessment of FHP.

A Study for the Appropriateness of the Different Reference Points in the Analysis of Working Posture

  • Kim, Day-Sung;Kim, Chol-Hong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.5
    • /
    • pp.637-644
    • /
    • 2011
  • Objective & Background: When applying various evaluation tools that analyze work posture risk through observation, accurate measurement of body flexion angle is very important. Method: This study investigated differences and appropriateness of 5 different existing reference points commonly used in the analysis of the work posture. Twenty five ergonomist and trained professionals were participated in this study. A Same flexion angle was utilized for the evaluation of risk assessment of musculoskeletal disorders using five different reference points to investigate the degree of difference between them. To investigate how different the observers' preferred flexion angle measuring methods were compared to the ISO 11226 Reference Posture, a virtual body model was constructed using the Poser 6.0 program. Six types of body flexion postures were constructed, and since neck flexion differs according to body angle, five types of neck flexion postures were constructed with the trunk bending $20^{\circ}$ forward, making up a total of 30 virtual flexion postures. Results: Results showed that the observers used personally preferred reference points instead of reference points recommend in the evaluation tools. Also the results revealed the their seems to be 6 types of flexion angle for the trunk and 11 types of measurement methods for the neck flexion angle in the form of personally preferred reference points. The results showed that a mean difference of $14^{\circ}$($4{\sim}23^{\circ}$) occurred in the trunk, and a mean difference of $20^{\circ}$($-8{\sim}51^{\circ}$) occurred in the neck. To increase accuracy when using the 5 evaluation tools in combination, the ISO 11226 standards, observers' preferred flexion posture standards, and common flexion posture standards of the evaluation tools were compared with the reference points of the 5 evaluation tools. Results showed considerable variance in angle difference for each evaluation tool. Conclusion: According to the results of this study, considering the angle difference between the flexion angle reference points of the evaluation tool and the reference points selected by the observers, it is concluded that instead of personally preferred reference points, the standardized reference points to enhance the accuracy and the objectivity. Application: The result of this study can be used as reference guide to develop the standardized reference point in the future.

Relation of head posture and occlusal contact area using photo occlusion analysis (광조사교합분석법을 이용한 머리 위치와 교합접촉면적의 관계)

  • Kim, Chang-Hwan;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.2
    • /
    • pp.90-97
    • /
    • 2019
  • Purpose: Previous studies related with occlusal contact area were limited that interocclusal thickness level or the method of measurement has not been accurate in measuring. The purpose of this study was to investigate the relation between head posture and occlusal contact area using photo occlusion analysis. Materials and Methods: 54 subjects with complete dentition (44 men, 10 women / 23 to 33 years of age) were included. To identify the relationship between head posture and occlusal contact area, subjects took interocclusal record in maximal intercuspal position with three different positions(supine position ($0^{\circ}$) / inclined position ($45^{\circ}$) / upright position ($90^{\circ}$)) on the dental unit chair. Occlusal contact area was analyzed using photo occlusion analysis. Statistical analyses were performed with SPSS ver.25.0 at 95% confidence interval. Results: Head posture has no significant effect on the changes of occlusal contact area (P > 0.05). Conclusion: When interocclusal relation is stable, head posture does not change a interocclusal record because head posture has no significant effect on occlusal contact area. Analysis of occlusal contact area using photo occlsion analysis device is useful due to its material property and simplicity.

The Effect of Lower Trapezius Muscle Exercise According to the Abduction Position of the Shoulder Joint on Round Shoulder Posture and Muscle Activity of the Lower Trapezius Muscle (어깨관절의 벌림 위치에 따른 아래등세모근 운동이 둥근어깨와 아래등세모근의 근활성도에 미치는 영향)

  • Chung-Yoo Kim;Won-Sik Bae;Hyeon-Su Kim;In-Seop Kim
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.11 no.4
    • /
    • pp.213-220
    • /
    • 2023
  • Purpose : The purpose of this study is to investigate the effect of each lower trapezius muscle exercise performed according to the abduction position (Y type - shoulder joint abduction 145 °, T type - shoulder joint abduction 90 °, and MPC type - shoulder joint 45 ° abduction) of the shoulder joint on the muscle activity of the round shoulder and lower trapezius muscle. Methods : This study was conducted on 31 adult men and women. Through random assignment, they were assigned to the Y group, T group, and MPC group. A 4-week intervention was performed for each group of 31 subjects who participated in the experiment, and shoulder height and lower trapezius muscle activity were measured before and after the intervention. Shoulder height measurement is a test to measure rounded shoulder posture. When the value is low, it means that rounded shoulder posture is improved. The muscle activity of the lower trapezius muscle was measured using the %MVIC method, and when the value is high, it means that the lower trapezius muscle is active. All measured data were verified using dependent t-tests for before and after comparisons and one-way analysis of variance for comparisons between groups. Results : The results of this study showed a significant decrease after intervention only in shoulder height. Muscle activity of the lower trapezius muscle decreased after intervention, but did not show a significant difference. Both variables showed no significant differences between groups. Conclusion : The results of this study show that three lower trapezius muscle exercises were performed on subjects in rounded shoulder posture. All three groups showed a significant decrease in the shoulder height value, a method of measuring rounded shoulder posture, and no significant differences between groups could be confirmed. Therefore, all three exercises can be considered effective in reducing shoulder posture.

The Effects of Flexion Angle of Shoulder Joints in Various Postures on Grip Strength (자세에 따른 어깨관절 굽힘 각도가 악력에 미치는 영향)

  • Lee, Sam Cheol;Kim, Bong Whan;Woo, Jung Jae
    • Journal of Korean Physical Therapy Science
    • /
    • v.20 no.1
    • /
    • pp.43-49
    • /
    • 2013
  • Background and purpose : The shoulder joints permit the greatest mobility of any joint area carries out the important function of stabilization for hand use. Research has now shown that grip strength has proven to be a reliable indicator for quality of life at an older age. The purpose of this study was to investigate the effects of testing posture and shoulder position on grip strength for repetitive gripping task. Methods : Forty(20male, 20female) college adult volunteers with no known shoulder dysfunction participated subject in two testing posture(sitting and standing) and three positions with shoulder flexion: (1) shoulder $0^{\circ}$ flexion (2) shoulder $90^{\circ}$ flexion (3) shoulder $180^{\circ}$ flexion. The paired t-test was used to determine any significant difference in grip strength between the testing posture and shoulder position. Results : The higher grip strength gained in the sitting with the shoulder $180^{\circ}$ flexion and the higher grip strength gained in the standing with the shoulder $180^{\circ}$ flexion. The second experiment showed that the grip strength was significant for sitting, standing position of shoulder $0^{\circ}$ flexion( p<0.05). Grip strength goes up as increase height and weight. Conclusion : These findings demonstrate that the theory does not fit with, because of the influence of gravity, a measure from the shoulder joint is the most high, $0^{\circ}$. And sitting posture and stance in the grip of a difference when compared SIT $0^{\circ}$ and standing position $0^{\circ}$ significant difference in indicated but, $90^{\circ}$ and $180^{\circ}$ in the sitting position and stance in the grip of the difference was not significant difference. To demonstrate the universality of this study's results, future studies should have a larger and more subject as well as a more even distribution of male and female subject. Therefore future research is needed to refine the definition and identify optimal methods of measuring this grip strength.

  • PDF

Changes in Balance Ability and Muscle Thickness of the Transverse Abdominis and Multifidus of Elderly Females after Eight Weeks of the Lumbar Stabilization Exercise (8주간의 요부안정화운동 시 여성노인의 균형능력 및 복횡.다열근 두께의 변화)

  • Ko, Dae-Sik;Kim, Gwon-Yeong;Lee, Chul-Gab;Lee, Kyoung-Il;Kim, Chan-Kyu;Jeong, Dae-In
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.4
    • /
    • pp.689-696
    • /
    • 2009
  • This study was conducted to examine the effects of the lumbar stabilization exercise (LSE) on fall prevention in elderly females (n = 21) by measuring changes in the isometric strength, multifidus, transverse abdominis muscle thickness, and posture stability index. The strength of isometric contraction was measured by the 3-D Pegasus system ; the thickness of the multifidus and transverse abdominis were measured by using Sonoace 6000C, and the posture stability index was measured using a computerized Biodex Balance System SD apparatus analysis. These results lead us to the conclusion that flexion and extension, left rotation on strength of isometric contraction, and thickness of the transverse abdominis (when released) statically increased. Overall, the anterior/posterior and medial/lateral elements in the posture stability index statically decreased, Consequently, the LSE should the prevent falls in elderly females.

Development of Textile Sensors for Prevention of Forward Head Posture (거북목 예방을 위한 텍스타일 센서 개발)

  • Minsuk kim;Jinhee Park;Jooyong Kim
    • Journal of Fashion Business
    • /
    • v.27 no.4
    • /
    • pp.125-140
    • /
    • 2023
  • This study aimed to develop a smart wearable device for assessing the risk angle associated with turtle neck syndrome in patients with Video Display Terminal (VDT) syndrome. Turtle neck syndrome, characterized by forward head posture resulting from upper cross syndrome, leads to thoracic kyphosis. In this research, a stretch sensor was used to monitor the progression of turtle neck syndrome, and the sensor data was analyzed using a Universal Testing Machine (UTM) and the Gauge Factor (GF) calculation method. The scapula and cervical spine angles were measured at five stages, with 15-degree increments from 0° to 60°. During the experimental process, the stretch sensor was attached to the thoracic spine in three different lengths: 30mm, 50mm, and 100mm. Among these, the attachment method yielding the most reliable data was determined by measuring with three techniques (General Trim Adhesive, PU film, and Heat Transfer Machine), and clothing using the heat transfer machine was selected. The experimental results confirmed that the most significant change in thoracic kyphosis occurred at approximately 30° of forward head posture. Prolonged deformity can lead to various issues, highlighting the need for textile sensor solutions. The developed wearable device aims to provide users with real-time feedback on their turtle neck posture and incorporate features that can help prevent or improve the condition.