• Title/Summary/Keyword: Posture measurement system

Search Result 106, Processing Time 0.033 seconds

Implementation of a Sensor Fusion FPGA for an IoT System (사물인터넷 시스템을 위한 센서 융합 FPGA 구현)

  • Jung, Chang-Min;Lee, Kwang-Yeob;Park, Tae-Ryong
    • Journal of IKEEE
    • /
    • v.19 no.2
    • /
    • pp.142-147
    • /
    • 2015
  • In this paper, a Kalman filter-based sensor fusion filter that measures posture by calibrating and combining information obtained from acceleration and gyro sensors was proposed. Recent advancements in sensor network technology have required sensor fusion technology. In the proposed approach, the nonlinear system model of the filter is converted to a linear system model through a Jacobian matrix operation, and the measurement value predicted via Euler integration. The proposed filter was implemented at an operating frequency of 74 MHz using a Virtex-6 FPGA Board from Xilinx Inc. Further, the accuracy and reliability of the measured posture were validated by comparing the values obtained using the implemented filters with those from existing filters.

Change of arterial pulse wave characteristic by measurement posture and brachial blood pressure (측정 자세 및 상완 혈압에 의한 맥파 특성 변화)

  • Nam, Ki-Chang;Kim, Eun-Gun;Hoe, Hyun;Huh, Young
    • Science of Emotion and Sensibility
    • /
    • v.12 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • In this study, pulse waves were measured at radial artery using non-invasive tonometric pulse pressure measurement system, SphygmoCor(AtCor, Australia), according to subject's posture. Then it was analysed whether the pulse wave parameters, which contain heart activities, change among three different postures (upright stand, sit, and supine). And it was also verified that the pulse wave parameters change among blood pressure level groups(hypotensive, normotensive, and hypertensive). As a results, posture effects were verified in time information of pulse wave rather than amplitude. But some parameters calculated by ratio of two amplitude, such as augmented index(AI) and ratio of central aortic pulse and radial artery pulse, showed significant difference according to postures. In post hoc test, time to the $1^{st}$ and $2^{nd}$ pulse peak(P_$T_1$, and P_$T_2$), ED(ejection duration), and HR(heart rate) showed significant difference among posture groups with each other. In comparison of blood pressure groups, it was verified that the parameters related to amplitude of pulse wave showed significant difference rather than time information.

  • PDF

Development of Relative Position Measuring Device for Moving Target in Local Area (국소영역에서 이동표적의 상대위치 측정 장치 개발)

  • Seo, Myoung Kook
    • Journal of Drive and Control
    • /
    • v.17 no.4
    • /
    • pp.8-14
    • /
    • 2020
  • Intelligent devices using ICT technology have been introduced in the field of construction machinery to improve productivity and stability. Among the intelligent devices, Machine Guidance is a device that provides real-time posture, location, and work range to drivers by installing various sensors, controllers, and satellite navigation systems on construction machines. Conversely, the efficiency of equipment that requires location information, such as machine guidance, will be greatly reduced in buildings, and tunnels in the GPS blind spots. Thus, the other high-precision positioning technologies are required in the GPS blind spot zone. In this study, we will develop a relative position measurement system that provides precise location information such as construction machinery and robots in a local area where the GPS reception is difficult. A relative position measurement system tracks a marker in the form of a sphere installed on a vehicle by using the image base tracking technology, and measures the distance and direction information to the marker to calculate a position.

Measurement of Breast Volume and the Area of Breast Base Using 3D Measurement System (3차원 측정시스템을 이용한 유방부피 및 유저면적의 측정)

  • 이현영;이옥경;홍경희
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.27 no.2
    • /
    • pp.270-276
    • /
    • 2003
  • Methodology was suggested to analyze breast volume, base area of breast bulk. and surface area of breast using the 3D measurement system. Thirty-seven middle-aged (30s-40s) women wearing 80A brassiere were participated in this study. Image of the upper body was captured by Phase-shifting moire. The posture of the subject was adjusted to get the full image of the right breast. Rapidform 2001 was used for the analysis of the images. The mean breast volume was 547.0㎤ and mean base area of breast bulk was 235. I$\textrm{cm}^2$ It was also found that the volume(r=0.169) and surface area of breast(r=10.242) were loosely correlated with the circumference difference between top and under breast. Therefore, it is noted that current selection criterion of cup size based on the difference in the two kinds of breast circumference is inadequate. The result of this study is expected to contribute to the design of ergonomic brassiere as well as surgical operations in the medical field.

The effects of increased unilateral and bilateral calcaneal eversion on pelvic and trunk alignment in standing position

  • Yi, Jaehoon
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.2
    • /
    • pp.84-88
    • /
    • 2016
  • Objective: Generally, it is known that there is a correlation between excessive calcaneus eversion and a patient with low back pain and it also affects pelvic alignment. However, there are not enough studies that show calcaneal eversion having an effect on the alignment of the trunk. Design: Cross-sectional study. Methods: A 3-dimensional motion analysis system was used to assess the lower limbs, pelvic alignment, and trunk alignment with increased unilateral and bilateral calcaneal eversion in twenty-one subjects. All subjects were asked to maintain a static posture for seven seconds on a wedge three times per posture for measurement and analysis purposes. The wedge used in the process was a lateral wedge with a 10-degree tilt to the lateral direction. To unify all of the subjects' foot position, the front and inner side of the wedge were marked. The height of the tilted wedge's inner side and flat wedge were balanced equally in order to be able to maintain the lateral part of the foot to the same height when producing an increased calcaneal eversion. Results: Comparing the changes in trunk and pelvic alignment in accordance to calcaneal eversion for each posture, there was a significant different in the X and Y-axis for each posture, but not in the Z-axis (p<0.05). Thus, it can be confirmed that calcaneal eversion in the sagittal plane and frontal plane may have and effect on the pelvis and the trunk. Conclusions: Postures with increased bilateral and unilateral calcaneal eversion has an effect on pelvic alignment, but does not cause any changes in trunk alignment.

Effects of the Cranio-cervical Static Stabilization Exercises among the Using Small Tools

  • Bae, Won-Sik;Lee, Keon-Cheol;Lee, Hyun-Ok
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.11 no.3
    • /
    • pp.65-72
    • /
    • 2016
  • PURPOSE: The purpose of this study is to determine the differences between the muscle activity of cranio-cervical flexion and extension muscles according to the types of tools used through a short-term intervention of cranio-cervical static stabilization exercises using small tools. METHODS: A total of fifteen male and female adults in their 20s who showed forward head posture in the overall body posture measurement system participated in this study. Each subject performed cranio-cervical static stabilization exercises about flexion and extension while using a sling, a foam roller, a TOGU ball, and without tools separately, and the muscle activity of the sternocleidomastoid muscle, scalenus anterior and splenius capitis was measured. Each value was measured for 10 seconds a total of three times. The maximum voluntary isometric contraction value was computed using the average during the middle four seconds. RESULTS: Cranio-cervical flexion exercises using various tool types, the average activity of the sternocleidomastoid and scalenus anterior muscles was significantly higher when applying the TOGU ball (p<.05). According to the results of implementing cranio-cervical flexion exercise using various tools, the maximum muscle activity of the sternocleidomastoid muscle was significantly higher for the TOGU ball (p<.05). CONCLUSION: Based on these results, the provision of an unstable surface using small tools rather than a stable surface is recommended as an exercise scheme for proprioceptive stimulation in a forward head posture. Particularly, we recommend using the TOGU ball for the provision of an unstable surface to increase the muscle activity of the sternocleidomastoid muscle and scalenus anterior.

Clinical Features Related to Occlusion and Head and Neck Posture in Patients with Internal Derangement of Temporomandibular Joint (악관절내장환자에서 교합관계와 두경부자세의 임상적 양상에 관한 연구)

  • 정호인;한경수;이규미
    • Journal of Oral Medicine and Pain
    • /
    • v.23 no.2
    • /
    • pp.127-141
    • /
    • 1998
  • This study was performed to investigate the clinical features of internal derangement of temporomandibular joint. For this study, 117 patients with temporomandibular disorders and 81 dental students without any signs and symptoms of temporomandibular disorders were selected as the patients group and as the control group, respectively. Preferred chewing side, Angle's classification, lateral guidance pattern, maximal mouth opening range, and affected side were recorded clinically. Head and shouldeer posture was measured in a groundplate on which square diagram of five centimeters each had been drawn, and cephalograph was also taken for measurement of head and neck posture. Sonopak of Biopak system (Bioresearch inc., USA) was used to record joint vibration for evaluation of internal healthy status of temporomandibular joint. The data collected were analyzed by SAS statistical program. The results of this study were as follows : 1. Frequency of left side chewing subjects was higher in patients than in control group, but there was no difference in distribution of subjects by Angle's classification. Other types was prvalent in patients whereas group function was more in control group for lateral guidance pattern. 2. As to lateral guidance pattern by clinical diagnosis, patients with internal derangement and/or degenerative joint disease showed higher frequency was consistent with the result by Sonopak impression. 3. There was no difference for shoulder height between the two groups, however, tilting of head and backward extension of cervical spine was more frequent in control group. 4. Acromion was positioned more anteriorly in patients with internal derangement and/or degenerative joint disease than in control group and angle between eye and tragus was larger in patients. Patients with degenerative joint disease showed more flexed head posture than control group did in cephalometric profile. 5. Maximal mouth opening range in patients with internal derangement was the least in all subgroups in patients classified by Sonopak impression.

  • PDF

Effects of Body Postures on Garment Pressure in Daily Wear (평상복 착용시 인체의 자세가 의복압에 미친 영향)

  • Kim, Yang-Weon
    • Korean Journal of Human Ecology
    • /
    • v.13 no.1
    • /
    • pp.153-158
    • /
    • 2004
  • With considerable development of comfortable and functional clothing in recent years, we need to evaluate the effects of garment pressure in daily wear on each parts of human body because the garment pressure is important to design the clothing. This study was designed to examine the effects of body postures on garment pressure on each parts of human body in the actual clothing conditions. All the data were collected from 50 volunteered subjects. The Garment pressure was measured in lune and December with 8 points CPMS clothing pressure system from scapular, upper am, elbow, under arm, front waist line, side waist line, abdomen, crista ilica, upper hip, middle hip, front thigh, back thigh, front knee and back knee. The postures of subjects were controlled with 3 positions such as standing (posture 1), sitting on the chair (posture 2), and sitting on the floor (posture 3) during measurement of clothing pressure. Clothing weights were more in men than in woman. It showed that clothing weights had no effects on the garment pressure. In this study, however, just the garment pressures on scapular and top of the hip increased significantly by clothing weight (p<. 05). Clothing horizontally pressed on scapular and top of hip but not on other parts. When subjects stood up, the garment pressure was the highest on the side waist. Especially, clothing pressure on the front waist point was lower than that of the left side waist. On the upper parts of the human body, the garment pressure of left side waist was the highest, and followed by front waist, crista ilica, and abdomen in order. When subjects were sitting on the chair, the garment pressure on the lower parts of the human body was the highest on the top of hip. When the subjects were sitting on the chair or on the floor, the surface area on their skin of hip and waist parts increased by postures. In addition, it showed that men felt more comfortable than women on higher clothing pressure level.

  • PDF

Three-dimensional Analysis of the Spine using Formetric 4D according to Upper Limb Movement and Resistance Application (상지의 움직임과 저항 적용에 따른 Formetric 4D를 이용한 척추의 3차원적 분석)

  • Kim, Hyun-Jin;Shin, Won-Seob
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.15 no.3
    • /
    • pp.69-77
    • /
    • 2020
  • PURPOSE: The aim of this study was to measure changes in spine inclination and thoracolumbar structure and morphology according to upper-extremity movements with and without resistance in order to evaluate the spine stability in workers. METHODS: Forty-eight middle-aged male workers (mean age, 40.48 ± 6.27 years) participated in this study. Using the spine analysis system, changes in the inclination of the spine and structure as well as shape of the thoracolumbar spine were measured. For posture measurement, the postures of standing, lifting the right and left arms (shoulder joint 90° flexion), and lifting with both arms were measured in random order. In addition, variables were measured using a resistance of 3 kg for each posture. The statistical significance level was set at α = .05 for all variables. RESULTS: There were statistically significant differences between the front and back inclinations of the spine, kyphotic curve of the thoracic spine, lordotic curve of the lumbar spine, rotation changes in the thoracolumbar spine, and rotation changes in the T4 vertebra (p < .05). However, there was no significant difference in the left and right tilts of the spine. In the post-hoc analysis, rotation changes in the T4 vertebra showed a significant difference in posture when resistance was applied to the left and right sides CONCLUSION: Causes of musculoskeletal diseases include excessive thoracic spine rotation, torsion, and hyperlordosis of the lumbar spine. Therefore, it is necessary to improve the working environment in order to ensure a healthy posture and prevent musculoskeletal diseases that can reduce the ability to carry various and/or excessive loads.

Knitted Data Glove System for Finger Motion Classification (손가락 동작 분류를 위한 니트 데이터 글러브 시스템)

  • Lee, Seulah;Choi, Yuna;Cha, Gwangyeol;Sung, Minchang;Bae, Jihyun;Choi, Youngjin
    • The Journal of Korea Robotics Society
    • /
    • v.15 no.3
    • /
    • pp.240-247
    • /
    • 2020
  • This paper presents a novel knitted data glove system for pattern classification of hand posture. Several experiments were conducted to confirm the performance of the knitted data glove. To find better sensor materials, the knitted data glove was fabricated with stainless-steel yarn and silver-plated yarn as representative conductive yarns, respectively. The result showed that the signal of the knitted data glove made of silver-plated yarn was more stable than that of stainless-steel yarn according as the measurement distance becomes longer. Also, the pattern classification was conducted for the performance verification of the data glove knitted using the silver-plated yarn. The average classification reached at 100% except for the pointing finger posture, and the overall classification accuracy of the knitted data glove was 98.3%. With these results, we expect that the knitted data glove is applied to various robot fields including the human-machine interface.