• Title/Summary/Keyword: Posterior trans-septal portal

Search Result 9, Processing Time 0.026 seconds

Observation of Lateral Compartment through Posteromedial Trans-posterior Septal Portal in Knee Joints (슬관절 후내측 후격막 통과 도달법을 이용한 외측 구획의 관찰)

  • Lee, Ghun-Shik;Park, Han-Sung;Kim, Sang-Hyo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.1
    • /
    • pp.56-59
    • /
    • 2005
  • Trans-posterior septal posterior arthroscopic portals are useful in performing arthroscopic diagnosis and treatment of the lesions located in posterior aspect of knee joints. Except inferior surface of posterior horn of lateral meniscus, we easily observed entire lateral compartment, especially inferior surface of anterior horn and lateral tibial condyle by figure of 4 position through posteromedial trans-posterior septal arthroscopic portal. And it was possible to obtain visual field from posterior aspect and we could use anteromedial and anterolateral portals for instrumentation without clouding. So, this procedure may be useful in performing surgery of lateral compartment especially, anterior aspect in the knee joints.

  • PDF

Intra-articular Giant Cell Tumor of Tendon Sheath Arising from Posterior Cruciate Ligament - Arthroscopic Excision Using Posterior Trans-septal Portal - (후방 십자 인대에서 발생한 건초성 거대 세포종 - 후격막 통과 도달법을 이용한 관절경적 절제 -)

  • Ahn, Jin Hwan;Seo, Jai Gon;Ha, Chul Won
    • Journal of the Korean Arthroscopy Society
    • /
    • v.2 no.1
    • /
    • pp.97-100
    • /
    • 1998
  • The giant cell tumor of tendon sheath is very rarely present inside the knee joint. The authors report a case of intraarticular giant cell tumor of tendon sheath arising from posterior cruciate ligament which was successfully excised arthroscopically using posterior trans-septal portal at the time of arthroscopic reconstruction of anterior cruciate ligament.

  • PDF

Arthroscopic Repair of the Postero-medial or Postero-lateral Capsule Tear in the Knee Joint - Technical Note - (슬관절 후내측 혹은 후외측 관절막 파열의 관절경적 봉합술 - 수술 수기 -)

  • Ahn Jin-Hwan;Cho Yang-Bum;Lee Yong-Seuk
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.2
    • /
    • pp.135-139
    • /
    • 2001
  • Purpose : Repair of the posterior capsule tear at the time of the operation for the chronic postero-lateral or postero-medial rotary instability has not been reported. We describe the arthroscopic repair of the posterior capsule tear using the posterior trans-septal portal. Method : After conducting basic arthroscopic examination of the knee, postero-medial and postero-lateral portals are secure to make the posterior trans-septal portal, through which the postero-medial and postero-lateral capsule tears are repaired using the suture hook under the arthroscopic guidance. Conclusion : When arthroscopic reconstruction of PCL insufficiency or postero-lateral rotaty instability that accompanies postero-medial or postero-lateral capsular tears. rising the posterior traits-septal portal could ensure better visualization of the capsule and a subsequent more accurate repair of the capsule. Since it significantly lessened instability, it could contribute to an achievement of successful clinical results.

  • PDF

Removal of a Femoral Interference Screw that Migrated Posteriorly after ACL Reconstruction, Using Posterior Trans-septal Portal - A Case Report - (전방 십자 인대 재건술 후 후방으로 전위된 대퇴 간섭 나사의 후방 경격막 도달법을 이용한 제거 - 증례 보고 -)

  • Ahn, Jin-Hwan;Lee, Sang-Hak;Ha, Hae-Chan
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.2
    • /
    • pp.187-191
    • /
    • 2006
  • Few cases have been reported in which the femoral interference screw has migrated into the posterior compartment after an ACL reconstruction. It usually requires removal, because it leads usually to mechanical symptom. However, the arthroscopic removal of a screw is a technically demanding procedure, especially in the case of an intact integrated ACL graft or one that is encapsulated around the screw. We present a case in which a displaced femoral interference screw migrated within the posterior compartment 11 years postoperatively, after the graft had been successfully incorporated at the femoral site and showed good continuity on MRI and arthroscopic examination. Although it is often technically challenging, through the use of a posterior trans-septal portal, we can successfully remove a displaced femoral interference screw even in the most difficult locations in the posterior compartment without damage to ACL graft.

  • PDF

Localized Pigmented Villonodular Synovitis Developed on the Posterior Cruciate Ligament of the Knee: Treatment Using Posterior Trans-septal Portal - A Case Report - (후방 십자 인대에 발생한 국소형 색소 융모 결절성 활액막염 : 관절경하 후방 경격막 삽입구를 이용한 치료 - 증례 보고 -)

  • Lee, Gyu-Yeong;Lee, Hwa-Sung;Chang, Dong-Gune
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.3
    • /
    • pp.264-267
    • /
    • 2009
  • Pigmented villonodular synovitis (PVNS) is a benign proliferative disorder of the synovium of joints. It occurs most commonly in the knee joint. The disease is composed of 2 different forms: diffuse and localized. The localized form is less frequent than the diffuse one. Most cases of localized PVNS involve the anterior compartment of the knee and can be usually easily diagnosed and treated with arthroscopy. We experienced a patient of localized PVNS developed on the posterior cruciate ligament, whose main symptom was persistent pain after trauma. This case occurs rarely and complete removal of the lesion was performed arthroscopically, using posterior trans-septal portal. We report this case with review of literatures.

  • PDF

Arthroscopic Repair of Acute Posterior Cruciate Ligament Rupture with Autogenous Hamstring Tendon Graft Augmentation - Technical Note (급성 후방 십자 인대 파열의 관절경하 봉합술 및 자가 슬괵 이식건 보강술 - 수술 술기 -)

  • Ahn, Jin-Hwan;Lee, Sang-Hak;Sung, Kee-Lyong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.1
    • /
    • pp.70-76
    • /
    • 2005
  • Purpose: We describe a new technique of arthroscopic repair with using autogenous hamstring tendon graft augmentation for the acute posterior cruciate ligament rupture. Operative technique: A routine arthroscopic examination of the knee joint is initially performed, then the posterior trans-septal portal is prepared with the using the posteromedial and posterolateral portals. The torn tibial stump that is retracted to the posterior compartment is repaired by a suture hook that is introduced through the anteromedial portal; visualization during this procedure is done with the arthroscope via the posteromedial portal. Using the retrieved suture, both suture ends are brought out to the anteromedial portal. The torn tibial stump is pulled to the intercondylar notch and then repaired with stitches at the anterior compartment. After the tibial and femoral tunnels are prepared without damaging the remnant PCL bundle, the combined torn PCL fibers and the autogenous single-bundle semitendinosus and gracilis tendon grafts are passed through the femoral tunnel and fixed together Conclusion: Arthroscopic repair of the torn tibial stump and autogenous hamstring tendon graft augmentation after preparing the tibial and femoral tunnels by using the trans-septal portal, without damaging the remnant PCL bundle, seems to be a very effective method for the treatment for acute PCL injuries, and especially for tears at the femoral attachment.

  • PDF

Arthroscopic Removal of Loose Bodies from the Knee (관절경을 이용한 슬관절 유리체 제거술)

  • Ahn, Jin Hwan;Ha, Chul Won;Hwang, Tae Kyu
    • Journal of the Korean Arthroscopy Society
    • /
    • v.2 no.2
    • /
    • pp.155-158
    • /
    • 1998
  • The purpose of this study is to evaluate the cause, size, number, nature and locaton of loose bodies in the knee joint and to describe the proper arthroscopic technique to remae the loose bodies according to the location of them. We retrospectively analysed thirty-three operations of arthroscopic removal of loose bodies from the knee. Eleven males and 22 females were included with average age of 38(range 7-71). Total number of removed loose bodies were more than sixty. The loose bodies were found most commonly at anterior intercondylar notch area. The most common associated pathology was degenerative arthritis. The most common size of loose bodies was in the range of 5mm to 10mm in diameter. The most common nature of loose bodies was osteochondral. The loose bodies located in suprapatellar pouch, medial gutter, lateral gutter. anterior intercondylar notch or posterior intercondylar notch were removed using standard portals such as anteromedial, anterolateral, superomedial and posteromedial portals. The removal of loose bodies located in upper portion of posteromedial or posterolateral compartment were greatly enhanced using posterior trans-septal portal. The proper portals for the visualization and removal of loose bodies were identified according to the location of loose bodies in the knee joint. More skill in the use of the arthroscope is required for the removal of loose bodies than for simple diagnostic arthroscopy.

  • PDF

Arthroscopic Synovectomy of the Knee in Hemophilic Patients (혈우병성 슬관절염의 관절경적 활액막 제거술)

  • Bae, Dae-Kyung;Yoon, Kyoung-Ho;Kim, Hee-Seon;Kim, Seung-Hwan;Chung, Sun-Teak
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.2
    • /
    • pp.177-182
    • /
    • 2002
  • Purpose : To validate the arthroscopic synovectomy for the treatment of hemophilic knee. Materials and Methods: From January 1996 to January 2001, 28 arthroscopic synovectolny were performed in 26 patients with hemophilic arthropathy of the knee. The mean age was 17.8 years. The mean follow-up period was 3 years 11 months. We used six portals (two anterior, two suprapatellar and two posterior) and posterior trans-septal portal in all cases. Result : The mean frequency of hemarthrosis was 4 times per month preoperatively and 2 postoperatively. The mean amount of factor replacement was 4,633 units preoperatively and 1,505 postoperatively. The mean range of motion was $112^{\circ}$ preoperatively and $107^{\circ}$ postoperatively. On radiographic evaluation, three cases were progressed at the latest follow-up. On the subjective evaluation, significant or moderate improvement were in 19 cases $(68\%)$, and no improvement or deterioration in 9 cases $(32\%)$. Conclusion : With complete synovectomy through the appropriate arthroscopic portals, arthroscopic synovectomy of the knee in hemophilic patients is the successful method in decreasing bleeding episodes, amount of factor replacement, knee pain and preventing or delaying onset of end-stage hemophilic arthropathy.

  • PDF

Arthroscopic Posterior Cruciate Ligament Reconstruction with Preservation of the Remnant Posterior Cruciate Ligament (남아 있는 후방 십자 인대 다발을 보존한 관절경하 후방 십자 인대 재건술)

  • Ahn Jin Hwan;Ha Kwon Ik;Chung Yoon Sung;Yang Il Soon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.4 no.2
    • /
    • pp.97-104
    • /
    • 2000
  • Purpose : The majority of PCL deficient knees have some intact remnant PCL bundles. In these cases, the remnant PCL bundles were removed fur easy passage of graft(especially in bone-patellar tendon-bone graft). The purpose of study is to report the results of PCL reconstruction by posterior transseptal portal technique and by preserving the remnant posterior cruciate ligament bundles. Materials & Methods : From November 1993 to June 1999, 44 arthroscopic posterior cruciate ligament reconstructions have been performed by one surgeon. We studied 37 knees those were followed up over 1 year among them. The mean age($14\~56$ years) was 31.8 years. The average follow-up period was 17.8 months($12\~61$ months). The graft materials were 29 double-loop hamstring autografts, 4 double-loop hamstring allografts and 4 Achilles tendon-bone allograft. Results : There are significant improvement of the preoperative subjective symptoms. The last follow-up shows that the average Lysholm knee score was markedly improved from 59.8 pre-operation to 89.2 post-operation and the average KT 2000 side difference was decreased from 11.1mm pre-operation to 2.3 mm post-operation. Follow-up MRI showed that the graft was healed with remnant posterior cruciate ligament bundles as one ligament. Conclusion : The posterior trans-septal portal makes it possible to locate the exact tibial tunnel. The arthroscopic PCL reconstruction preserving the remnant of original PCL bundles seems to provide the good result.

  • PDF