• Title/Summary/Keyword: Posterior restorations

Search Result 111, Processing Time 0.028 seconds

A full-mouth rehabilitation using zirconia all-ceramic crowns: a case report (지르코니아 전부 도재관을 이용한 구강 완전 회복 증례)

  • Choi, In-Seon;Kim, Dong-Woon;Lee, Jung-Jin;Kim, Kyoung-A;Seo, Jae-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.3
    • /
    • pp.231-241
    • /
    • 2015
  • As patients' esthetic expectations increase, there is an increase in demand for cosmetic restorations of anterior and posterior teeth that resemble the natural tooth morphology and color. An example of high-strength all-ceramic systems is zirconia with CAD/CAM application. This case report describes a full-mouth rehabilitation using zirconia all-ceramic crowns supported by upper and lower implants and by a minimal increase in the occlusal vertical dimension in a patient with severe abrasion due to loss of posterior teeth.

Development of dental zirconia (치과용 지르코니아의 발전)

  • Kim Sung-Hun
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.32 no.1
    • /
    • pp.4-7
    • /
    • 2023
  • Since the end of the 1990s, zirconia, which has been applied to dental prostheses, has been used in the form of coping or framework. The prostheses made in this way have been successfully used in the anterior teeth because they have no metal components as a structure. But in the posterior teeth, its use was limited due to the fracture or chipping of the veneering porcelain during the function. Later, as a solution to this shortcoming, a monolithic zirconia restoration was proposed in which a strong coping material was used in the form of a complete prosthesis. But, this resulted in some unesthetic results due to the characteristics of zirconia, which has excellent resistance to strong forces but is very white and opaque. However, now, due to technological advances in increasing the translucency of zirconia, it is possible to produce strong and esthetic zirconia restorations not only in the posterior region but also in the anterior region. In this article, the structural characteristics of various types of zirconia materials that have been developed so far, were discussed, and where the zirconia products actually in use belong to was explained.

A comparative study on the correlation between Korean foods and the fractures of PFG and all ceramic crowns for posterior applications (구치용 도재소부금관과 전부도재관에 파절을 일으키는 한국음식에 관한 연구)

  • Kim, Jeong-Ho;Lee, Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.156-163
    • /
    • 2009
  • Statement of problem: Recently, there have been increased esthetic needs for posterior dental restorations. The failure of posterior dental ceramic restoration are possible not only by the characters of the component materials but also by the type of food. Purpose: The research aim was to compare the in vitro fracture resistance of simulated first molar crowns fabricated using 4 dental ceramic systems, full-porcelain-occlusal-surfaced PFG, half-porcelain-occlusal-surfaced PFG, Empress 2, Ice Zirkon and selected Korean foods. Material and methods: Eighty axisymmetric crowns of each system were fabricated to fit a preparation with 1.5- to 2.0-mm occlusal reduction. The center of the occlusal surface on each of 15 specimens per ceramic system was axially loaded to fracture in a Instron 4465, and the maximum load(N) was recorded. Afterwards, selected Korean foods specimens(boiled crab, boiled chicken with bone, boiled beef rib, dried squid, dried anchovy, round candy, walnut shell) were prepared. 15 specimens per each food were placed under the Instron and the maximum fracture loads for them were recorded. The 95% confidence intervals of the characteristic failure load were compared between dental ceramic systems and Korean foods. Afterwards, on the basis of previous results, 14Hz cyclic load was applied on the 4 systems of dental ceramic restorations in MTS. The reults were analyzed by analysis of variance and Post Hoc tests. Results: 95% confidence intervals for mean of fracture load 1. full porcelain occlusal surfaced PFG Crown: 2599.3 to 2809.1 N 2. half porcelain occlusal surfaced PFG Crown: 3689.4 to 3819.8 N 3. Ice Zirkon Crown: 1501.2 to 1867.9 N 4. Empress 2 Crown: 803.2 to 1188.5 N 5. boiled crab: 294.1 to 367.9 N 6. boiled chicken with bone: 357.1 to 408.6 N 7. boiled beef rib: 4077.7 to 4356.0 N 8. dried squid: 147.5 to 190.5 N 9. dried anchovy: 35.6 to 46.5 N 10. round candy: 1900.5 to 2615.8 N 11. walnut shell: 85.7 to 373.1 N under cyclic load(14Hz) in MTS, fracture load and masticatory cycles are: 1. full porcelain occlusal surfaced PFG Crown fractured at 95% confidence intervals of 4796.8-9321.2 cycles under 2224.8 N(round candy)load, no fracture under smaller loads. 2. half porcelain occlusal surfaced PFG Crown fractured at 95% confidence intervals of 881705.1-1143565.7 cycles under 2224.8 N(round candy). no fracture under smaller loads. 3. Ice Zirkon Crown fractured at 95% confidence intervlas of 979993.0-1145773.4 cycles under 382.9 N(boiled chicken with bone). no fracture under smaller loads. 4. Empress 2 Crown fractured at 95% confidence intervals of 564.1-954.7 cycles under 382.9 N(boiled chicken with bone). no fracture under smaller loads. Conclusion: There was a significant difference in fracture resistance between experimental groups. Under single load, Korean foods than can cause fracture to the dental ceramic restorations are boiled beef rib and round candy. Even if there is no fracture under single load, cyclic dynamic load can fracture dental posterior ceramic crowns. Experimental data with 14 Hz dynamic cyclic load are obtained as follows. 1. PFG crown(full porcelain occlusion) was failed after mean 0.03 years under fracture load for round candy(2224.8 N). 2. PFG crown(half porcelain occlusion) was failed after mean 4.1 years under fracture load for round candy(2224.8 N). 3. Ice Zirkon crown was failed after mean 4.3 years under fracture load for boiled chicken with bone(382.9 N). 4. Empress 2 crown was failed after mean 0.003 years under fracture load for boiled chicken with bone(382.9 N).

MAXILLARY SINUS GRAFT FOR ENDOSSEOUS IMPLANT PLACEMENT : REVIEW OF THE LITERATURES (임프란트 식립을 위한 상악동점막 거상술: 문헌고찰)

  • Kim, Su-Gwan;Gang, Tae-Ho;Park, Jeong-Yeol;Kim, Soo-Min;Park, In-Soon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.5
    • /
    • pp.527-532
    • /
    • 2000
  • A review of the literature, provided by a MEDLINE search from 1980 through June 1999, was performed. This study was screened that 649 patients received 679 sinus lift grafts in which 2056 implants were placed. The types of grafts in sinus augmentation were autogenous bone, corticocancellous block bone, allogenic bone, and a variety of alloplastic materials. Results of these grafts are presented. The most frequent complications was the infection of maxillary sinus. Long-term follow-up is necessary to advance the sinus elevation and to support posterior maxillary restorations.

  • PDF

Long-term results of new deproteinized bovine bone material in a maxillary sinus graft procedure

  • Shin, Seung-Yun;Hwang, You-Jeong;Kim, Jung-Hoon;Seol, Yang-Jo
    • Journal of Periodontal and Implant Science
    • /
    • v.44 no.5
    • /
    • pp.259-264
    • /
    • 2014
  • Purpose: The aim of this case report is to present the longitudinal results of sinus grafting using a new demineralized bovine bone material (DBBM) in human cases. Methods: A patient with a resorbed maxilla was treated by maxillary sinus grafting using a new deproteinized bovine bone material. After a healing period of 6.5 months, three implants were placed and restored. The patient was periodically recalled and followed up for 5 years after restoration. Results: Twelve partially edentulous patients (average age, 55.7 years) were followed up. All patients had insufficient residual height in their maxillary posterior area and underwent maxillary sinus graft surgery to increase the height of their maxilla. In all, 27 fixtures were placed in the augmented bone area. On average, 8.6 months later, implants were loaded using provisional or final restorations. The observation period ranged from 27 to 75 months (average, 43.3 months), and the patients did not show any severe resorption of the graft material or any infection during this time. Conclusions: Our results show that the new DBBM is useful for a maxillary sinus graft procedure. Good healing responses as well as reliable results were obtained for an average follow-up period of 43.3 months.

A 2-year clinical evaluation of Sculpture crowns

  • Ku, Chul-Whoi;Yang, Hong-So
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.6
    • /
    • pp.806-813
    • /
    • 2000
  • Statement of problems. There are only a few studies available that deal with the clinical behavior of ceromer systems as potential substitutes for metal-ceramic crowns. Purpose. This prospective study was initiated to evaluate the clinical performance of 35 Sculpture crowns after 2 years in service. Material and methods. Thirty five Sculpture crowns were placed for 20 patients (7 men and 13 women). All patients were treated by the same dentist, and all restorations were fabricated by the same dental laboratory. Crown placement involved both the anterior and posterior regions of the dental arches. Patients were evaluated by two examiner at baseline, 12, and 24 months using the CDA quality assessment system in addition to periodontal criteria. Results. Of 34 crowns remaining in the study after 2 years, only one crown had experienced a marginal fracture. The crown was replaced as a result of recurrent caries. All remaining crowns were ranked as either excellent or acceptable for surface and color, anatomic form, and marginal integrity. Conclusion. The 2-year clinical observations and ranking with the CDA quality assessment criteria supported the conclusion that Sculpture crowns may be used in substitutes for metal-ceramic crowns.

  • PDF

Wear of contemporary dental composite resin restorations: a literature review

  • Dimitrios Dionysopoulos;Olga Gerasimidou
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.2
    • /
    • pp.18.1-18.13
    • /
    • 2021
  • Composite resins are the most commonly used dental restorative materials after minimally invasive dental procedures, and they offer an aesthetically pleasing appearance. An ideal composite restorative material should have wear properties similar to those of tooth tissues. Wear refers to the damaging, gradual loss or deformation of a material at solid surfaces. Depending on the mechanism of action, wear can be categorized as abrasive, adhesive, fatigue, or corrosive. Currently used composite resins cover a wide range of materials with diverse properties, offering dental clinicians multiple choices for anterior and posterior teeth. In order to improve the mechanical properties and the resistance to wear of composite materials, many types of monomers, silane coupling agents, and reinforcing fillers have been developed. Since resistance to wear is an important factor in determining the clinical success of composite resins, the purpose of this literature review was to define what constitutes wear. The discussion focuses on factors that contribute to the extent of wear as well as to the prevention of wear. Finally, the behavior of various types of existing composite materials such as nanohybrid, flowable, and computer-assisted design/computer-assisted manufacturing materials, was investigated, along with the factors that may cause or contribute to their wear.

Photoelastic Stress Analysis of Fixed Partial Dentures (가공의치(架工義齒)에 작용(作用)하는 Stress에 관(關)한 광탄성학적(光彈性學的) 분석(分析))

  • Cho, Won-Haeng
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.18 no.1
    • /
    • pp.15-35
    • /
    • 1980
  • The purpose of this study was to investigate stresses in the various components of fixed partial dentures restoring the posterior teeth of the lower jaw, and to measure quantitatively the effects of certain modifications in structural design on the stresses in the restorations using two-dimensional photoelasticity. Two-dimensional photoelastic methods were used in this study. Several models of fixed partial dentures were constructed. Shoulder less margins and anatomic occlusal reduction were incorporated in Model 1. Rounded shoulders and flat occlusal reduction were incorporated in Model 2, while Model 3 was a cantilever fixed partial denture. Other similar fixed partial dentures were constructed with V and U notches deliverately included in the region of the fixed joints for comparative reasons. The birefringent materials used in this study were PSM-1 and PSM-5 in standard sheets. PSM-1 was used for constructing the substructure, and PSM-5 was used in making the components of the fixed partial dentures. The two materials were used in the construction of composite photoelastic models. Improved artificial stone was used to represent dental cement in luting the composite photoelastic models. Static loading procedures were used at preplanned sites to represent occlusal loads in the mouth. 35 mm color and B/W film were used to record isochromatics in accordance with photoelastic procedures. Data reduction was performed using the grid method, which helped in, the mathematical integration procedure (Shear difference method) to separate the principal stresses. The results were as follows. 1. Fixed partial dentures do not function in bending as a symmetrical beam. Alternate areas of tension and compression were demonstrated when multiple contact loading was used. 2. The weakest part in posterior fixed partial dentures is the fixed joint. 3. (1) Models I and modified Model I were loaded on the pontic using a 50 pound vertical static load. The shear stress near the posterior fixed joint in Model 1 (U notches) was+129.4 p.s.i., and at the same fixed joint in modified Model 1 (V notches) was+239.4 p.s.i. The concentration of stress in fixed joint was reduced by 50% when U notches replaced the V notches. (2) Modified Model 2 was loaded using a multiple contact loader at a total load of 125 pounds. The difference between the principal stresses (${\sigma}_1-{\sigma}_2$), shear stress, at the V notches was+600 p.s.i., and at the U notches was+3l7 p.s.i. The shear stress was reduced by 50% when U notches replaced the V notches. V-grooves at the fixed joints should be avoided, and should be replaced by regular shaped U-grooves. 4. Cantilever fixed partial dentures had much higher stresses at the fixed joint than fixed partial dentures that were attached at both ends.

  • PDF

Impact of Dental Treatment under General Anesthesia or Intravenous Sedation on Oral Health-related Quality of Life in Pediatric Dental Patients (전신마취 또는 정주진정 하 치과치료가 소아 환자의 구강 건강과 관련된 삶의 질에 미치는 영향)

  • Song, Jisoo;Kim, Youngjae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.1
    • /
    • pp.27-35
    • /
    • 2016
  • The present study aimed to assess the perception of a child's primary caregiver on the oral health-related quality of life (OHRQoL) of dental treatment under general anesthesia (GA) or intravenous sedation (IV-SED) in pediatric dental patients. Self-administered questionnaires were completed before dental treatment under GA or IV-SED by 52 primary caregivers of healthy pediatric patients (10 years old or younger), and 43 (84%) of these caregivers completed the same questionnaires within 6 months after treatment. The Korean version of Child Oral Health Impact Profile (COHIP) and the Family Impact Scale (FIS) were used to assess OHRQoL in the questionnaires. The scores of COHIP and FIS improved after dental treatment. Demographic variables such as gender did not affect the improvement of COHIP and FIS, and age did not affect that of COHIP. However, baseline FIS score of younger patients was better than that of older patients before dental treatment. Regardless of the treatment variables, all COHIP and FIS scores were improved after dental treatment. COHIP score improved more in cases with pulp treatments compared to those without the treatments. On the other hand, FIS score improved less in cases with posterior stainless steel crown restorations compared to those without them. Anterior esthetic restorations and anterior teeth extractions did not affect the degree of improvement. Based on the primary caregiver's perceptions, the OHRQoL of healthy pediatric patients was improved by dental treatment under GA or IV-SED.

Full-mouth rehabilitation in an amelogenesis imperfecta patient with anterior open bite using CAD/CAM system (전치부 개방교합을 보이는 법랑질형성부전증 환자의 CAD/CAM system을 이용한 전악 수복 증례)

  • Lee, Sang-Hoon;Yi, Yang-Jin;Jo, Deuk-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.4
    • /
    • pp.410-418
    • /
    • 2017
  • Amelogenesis imperfecta characterized as abnormally formed enamel is caused by a defect of unique group of genes. Patients affected by this disease might have difficulties in social and psychological aspects due to non-esthetic teeth as well as functional problems caused by enamel detachment and tooth wear from their early ages. Adult patients with amelogenesis imperfecta can be treated with full-mouth restorations, which make functional and esthetic rehabilitations of severely worn tooth. However, the anterior open bite and lack of occlusal clearance for posterior teeth restorations due to compensatory extrusion are the intervening factors in the prosthetic treatment. Therefore, the determination of anterior tooth lengths, vertical dimension, and anterior guidance should be set carefully. Recently, computer-aided design and computer-aided manufacturing (CAD/CAM) techniques help systematic approaches and enable dentists to reduce time-consuming procedures in the diagnosis and treatment of full-mouth rehabilitation. This case report demonstrates the successful full mouth rehabilitation using a CAD/CAM system in a young adult patient with amelogenesis imperfecta and anterior open bite.