• Title/Summary/Keyword: Posterior facet

Search Result 74, Processing Time 0.025 seconds

Correlation Analysis of Reduction for Intra-Articular Calcaneal Fracture and Clinical Outcomes Using Postoperative Computed Tomography (수술 후 컴퓨터 단층촬영을 이용한 관절 내 종골 골절의 정복과 임상 결과 간의 연관성 분석)

  • Eom, Joon-Sang;Joo, Young-Deuk;Kim, Seong-Jun;Shin, Min-Ho;Lee, Dong-Oh;Jung, Hong-Geun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.18 no.4
    • /
    • pp.165-172
    • /
    • 2014
  • Purpose: We evaluated the correlation of postoperative clinical outcomes and radiologic findings using computed tomography and simple X-ray in intra-articular calcaneal fractures. Materials and Methods: The current study is based on 41 feet, 38 patients with displaced intra-articular fracture who underwent surgical treatment with at least one year of follow-up. Evaluation of clinical outcome included American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score, visual analogue scale (VAS) score, and subjective satisfaction. A simple X-ray was used in evaluation of preoperative and postoperative Gissane angle, B${\ddot{O}}$hler angle, and calcaneal fracture width. Computed tomography scan was performed for evaluation of preoperative and postoperative articular step-off and articular gap in all cases. Finally, we evaluated the correlation of the postoperative clinical outcomes and radiologic findings based on the measurement. Results: The average postoperative AOFAS score and VAS score was $84.1{\pm}8.5$ and $2.2{\pm}2.2$. Subjective satisfaction was excellent in 15 cases, good in 19 cases, and fair in seven cases. The average B${\ddot{O}}$hler angle was restored from $11.1^{\circ}$ to $24.7^{\circ}$(p<0.05), Gissane angle was changed from $121.0^{\circ}$ to $119.0^{\circ}$ (p>0.05), and the average width was restored from 45.8 to 35.0 mm (p<0.05). The average articular step-off and gap were decreased from 6.3 to 2.0 mm and from 11.1 to 4.6 mm, respectively (p<0.05). No significant correlations were observed between the clinical outcome and Gissane angle, B${\ddot{O}}$hler angle, and width, and there was no significant correlation between the clinical outcome and Sanders classification. However, postoperative articular step-off showed correlation with VAS and AOFAS score and articular gap showed correlation with VAS score. Conclusion: The clinical outcome did not show correlation with B${\ddot{O}}$hler angle and Gissane angle but did show correlation with anatomical reduction of the posterior facet joint.

Impact of Chronic Lateral Ankle Instability with Lateral Collateral Ligament Injuries on Biochemical Alterations in the Cartilage of the Subtalar and Midtarsal Joints Based on MRI T2 Mapping

  • Hongyue Tao;Yiwen Hu;Rong Lu;Yuyang Zhang;Yuxue Xie;Tianwu Chen;Shuang Chen
    • Korean Journal of Radiology
    • /
    • v.22 no.3
    • /
    • pp.384-394
    • /
    • 2021
  • Objective: To quantitatively assess biochemical alterations in the cartilage of the subtalar and midtarsal joints in chronic lateral ankle instability (CLAI) patients with isolated anterior talofibular ligament (ATFL) injuries and combined calcaneofibular ligament (CFL) injuries using MRI T2 mapping. Materials and Methods: This study was performed according to regulations of the Committee for Human Research at our institution, and written informed consent was obtained from all participants. Forty CLAI patients (26 with isolated ATFL injuries and 14 with combined ATFL and CFL injuries) and 25 healthy subjects were recruited for this study. All participants underwent MRI scans with T2 mapping. Patients were assessed with the American Orthopedic Foot and Ankle Society (AOFAS) rating system. The subtalar and midtarsal joints were segmented into 14 cartilage subregions. The T2 value of each subregion was measured from T2 mapping images. Data were analyzed with ANOVA, the Student's t test, and Pearson's correlation coefficient. Results: T2 values of most subregions of the subtalar joint and the calcaneal facet of the calcaneocuboid joint in CLAI patients with combined CFL injuries were higher than those in healthy controls (all p < 0.05). However, there were no significant differences in T2 values in subtalar and midtarsal joints between patients with isolated ATFL injuries and healthy controls (all p > 0.05). Moreover, T2 values of the medial talar subregions of the posterior subtalar joint in patients with combined CFL injuries showed negative correlations with the AOFAS scores (r = -0.687, p = 0.007; r = -0.609, p = 0.021, respectively). Conclusion: CLAI with combined CFL injuries can lead to cartilage degeneration in subtalar and calcaneocuboid joints, while an isolated ATFL injury might not have a significant impact on the cartilage in these joints.

Osteoporotic Vertebral Fractures: SPECT Findings (골다공증에 동반된 척추골절의 골 SPECT 소견)

  • Baik, Jun-Hyun;Park, Young-Ha;Ihn, Yon-Kwon;Kim, Sung-Hoon;Chung, Yong-An;Yoo, Ie-Ryung;Kim, Jee-Yeung;Jung, Hyun-Seok;Sohn, Hyung-Seon;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.6
    • /
    • pp.522-527
    • /
    • 2004
  • Purpose: The purpose of this study was to evaluate the usefulness of single photon emission computed tomography (SPECT) of bone using Tc-99m MDP in the diagnosis of osteoporotic vertebral fractures. Materials and Methods: Thirty two patients with osteoporotic vertebral fracture were included in this study (mean age: $67{\pm}8$, male: 5, female: 27). Seventy nine vertebral fractures were detected (38 thoracic/thoracolumbar lesions and 41 lumbar lesions), which were classified by type of deformity (wedge, biconcave or compression). The patterns and locations of increased uptakes were examined and analyzed. Results: Forty seven wedge fractures, 20 biconcave fractures and 12 compression fractures were found. Diffuse and asymmetric uptakes were common in fractured bodies. More than one uptake were examined in 69 posterior elements of fractured vertebrae (87.3%) including 40 of 47 wedge fractures (85.1%), 17 of 20 biconcave fractures (85.0%) and 12 of 12 compression fractures (100%). Wedge fractures were predominant fracture in thoracic/thoracolumbar spine whereas incidence of biconcave or compression type war similar to that of wedge fracture in lumbar spine (p=0.04). Spinous process uptake was more frequently seen in lumbar lesions than thoracic/thoracolumbar lesions (p=0.009). Facet joint uptake in biconcave fracture was more common in lumbar spine (92.3%) than thoracic/thoracolumbar spine (57.1%). Spinous process uptake in biconcave fracture was also more frequently detected in lumbar spine (p=0.043). Conclusion: Bone SPECT was useful in the evaluation of osteoporotic vertebral fracture, especially posterior elements of vertebrae.

Effect of Implant Types and Bone Resorption on the Fatigue Life and Fracture Characteristics of Dental Implants (임플란트 형태와 골흡수가 임플란트 피로 수명 및 파절 특성에 미치는 효과에 관한 연구)

  • Won, Ho-Yeon;Choi, Yu-Sung;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.121-143
    • /
    • 2010
  • To investigate the effect of implant types and bone resorption on the fracture characteristics. 4 types of Osstem$^{(R)}$Implant were chosen and classified into external parallel, internal parallel, external taper, internal taper groups. Finite elements analysis was conducted with ANSYS Multi Physics software. Fatigue fracture test was performed by connecting the mold to the dynamic load fatigue testing machine with maximum load of 600N and minimum load of 60N. The entire fatigue test was performed with frequency of 14Hz and fractured specimens were observed with Hitachi S-3000 H scanning electron microscope. The results were as follows: 1. In the fatigue test of 2 mm exposed implants group, Tapered type and external connected type had higher fatigue life. 2. In the fatigue test of 4 mm exposed implants group, Parallel type and external connected types had higher fatigue life. 3. The fracture patterns of all 4 mm exposed implant system appeared transversely near the dead space of the fixture. With a exposing level of 2 mm, all internally connected implant systems were fractured transversely at the platform of fixture facing the abutment. but externally connected ones were fractured at the fillet of abutment body and hexa of fixture or near the dead space of the fixture. 4. Many fatigue striations were observed near the crack initiation and propagation sites. The cleavage with facet or dimple fractures appeared at the final fracture sites. 5. Effective stress of buccal site with compressive stress is higher than that of lingual site with tensile stress, and effective stress acting on the fixture is higher than that of the abutment screw. Also, maximum effective stress acting on the parallel type fixtures is higher. It is careful to use the internal type implant system in posterior area.