Proficiency Test for the Dosimetry Audit Service Provider

  • Chul-Young Yi;In Jung Kim;Jong In Park;Yun Ho Kim;Young Min Seong
    • 한국의학물리학회지:의학물리
    • /
    • 제33권4호
    • /
    • pp.72-79
    • /
    • 2022
  • Purpose: The proficiency test was conducted to assess the performance of the dosimetry audit service provider in the readout practice of the dose delivered to patients in medical institutions. Methods: A certain amount of the absorbed dose to water for the high-energy X-ray from the medical linear accelerator (LINAC) installed in the Korea Research Institute of Standards and Science (KRISS) was delivered to the postal dose audit package given by the dosimetry audit service provider, in which the radio-photoluminescence (RPL) glass dosimeters were mounted. The dosimetry audit service provider read the RPL glass dosimeters and sent the readout dose value with its uncertainty to KRISS. The performance of the dosimetry audit service provider was evaluated based on the En number given in ISO/IEC 17043:2010. Results: The evaluated En number was -0.954. Based on the ISO/IEC 17043, the performance of the dosimetry service provider is "satisfactory." Conclusions: As part of the conformity assessment, the KRISS performed the proficiency test over the postal dose audit practice run by the dosimetry audit service provider. The proficiency test is in line with confirming the traceability of the medical institutions to the primary standard of absorbed dose to the water of the KRISS and ensuring the confidence of the dosimetry audit service provider.

Postal Dosimetry Audits for the Domestic Medical Linear Accelerator

  • Kim, Kum Bae;Choi, Sang Hyoun
    • 한국의학물리학회지:의학물리
    • /
    • 제31권2호
    • /
    • pp.20-28
    • /
    • 2020
  • Purpose: The objective of this study is to perform Postal dosimetry audits for medical linear accelerators in radiation therapy institutions using glass dosimeters and Gafchromic film reading systems and postal dosimetry audit procedures, and to evaluate radiation therapy doses and mechanical accuracy in medical institutions. Methods: Photon output measured and analyzed using a standard phantom for measuring photon output dose using a glass dosimeter for medical linear accelerators. Mechanical accuracy was measured and analyzed using software for film measurement. Results: Measurement and analysis of photon beam output dose using a standard phantom glass dosimeter for photon beam output dose measurement was completed. All tolerance doses were within 5%. Mechanical accuracy measurement and analysis using a standard phantom for verifying the mechanical accuracy of linear accelerator (LINAC) using a Gafchromic film were completed, and all results were shown within tolerances (2 mm or less). Conclusions: In this study, Postal dosimetry audits were performed on the output dose and mechanical accuracy of photon beams (207 beams) for 106 LINACs from 48 institutions. As a result of corrective action and re-execution, it was confirmed that all engines met the acceptable standard within 2 mm in the linear accelerator.

식품의약품안전청의 치료방사선 선량보증과 측정불확도 (KFDA TLD Dose Quality Audit and Measurement Uncertainty)

  • 정희교;이현구;김귀야;양현규;임천일
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.153-156
    • /
    • 2004
  • 식품의약품안전청은 1978년 12월 방사선 분야의 국가교정검사기관으로 지정되어 현재까지 Co-60선원을 이용 치료준위 방사선측정기에 대한 교정을 수행하고 있다. 식약청의 에어커마와 물 흡수선량 측정값은 국제도량형국(BIPM)과 측정소급성을 유지하고 있으며, 교정계수의 확장불확도는 0.9 %(k=2)이다. 식약청에서는 외부방사선에 대한 선량보증의 일환으로 1999년 전리함을 이용하여 방사선치료기관의 선량측정을 수행하였으며, 2002년부터 열형광선량계(TLD)를 이용한 선량측정체계를 확립 ${\cdot}$ 운영하고 있다. TLD 판독에 대한 측정불확도는 1.6 %(k=1)이며, 측정불확도를 감안하여 선량보증의 허용한계를 ${\pm}$ 5 %로 설정하였다. TLD 판독값을 선량으로 전환하는 과정에서 선질, 비선형성, 홀더사용 등의 영향을 보정하기 위한 보정정수를 사용하였다. 2003년도 치료방사선 선량보증사업에는 53개 기관(71개 선질)이 참여하였다. 선량보증 결과 71개 선질 중63개 선질(89 %)이 1차 측정에서 허용한계를 만족하였다. 허용한계 초과기관에 대해서는 재측정을 수행하였고, 그 결과 모두 허용한계 이내의 값을 나타냄을 확인하였다.