• Title/Summary/Keyword: Post-operative CT

Search Result 71, Processing Time 0.029 seconds

Role of $^{18}F$-fluoro-2-deoxyglucose Positron Emission Tomography in Gastric GIST: Predicting Malignant Potential Pre-operatively

  • Park, Jeon-Woo;Cho, Chang-Ho;Jeong, Duck-Su;Chae, Hyun-Dong
    • Journal of Gastric Cancer
    • /
    • v.11 no.3
    • /
    • pp.173-179
    • /
    • 2011
  • Purpose: It is difficult to obtain biopsies from gastrointestinal stromal tumors (GISTs) prior to surgery because GISTs are submucoal tumors, despite being the most common nonepithelial neoplasms of the gastrointestinal tract. Unlike anatomic imaging techniques, PET-CT, which is a molecular imaging tool, can be a useful technique for assessing tumor activity and predicting the malignant potential of certain tumors. Thus, we aimed to evaluate the usefulness of PET-CT as a pre-operative prognostic factor for GISTs by analyzing the correlation between the existing post-operative prognostic factors and the maximum SUV uptake (SUVmax) of pre-operative 18F-fluoro-2-deoxyglucose (FDG) PET-CT. Materials and Methods: The study was conducted on 26 patients who were diagnosed with gastric GISTs and underwent surgery after being examined with pre-operative FDG PET-CT. An analysis of the correlation bewteen (i) NIH risk classification and the Ki-67 proliferation index, which are post-operative prognostic factors, and (ii) the SUVmax of PET-CT, which is a pre-operative prognostic factor, was performed. Results: There were significant correlations between (i) SUVmax and (ii) Ki-67 index, tumor size, mitotic count, and NIH risk group (r=0.854, 0.888, 0.791, and 0.756, respectively). The optimal cut-off value for SUVmax was 3.94 between "low-risk malignancy" and "high-risk malignancy" groups. The sensitivity and specificity of SUVmax for predicting the risk of malignancy were 85.7% and 94.7%, respectively. Conclusions: The SUVmax of PET-CT is associated with Ki-67 index, tumor size, mitotic count, and NIH classification. Therefore, it is believed that PET-CT is a relatively safe, non-invasive diagnostic tool for assessing malignant potential pre-operatively.

Deviations of Implant Position between Pre- and Post-operation in Computer-guided Template-based Implant Placement (Computer-guided template를 이용한 임플란트 식립에서 술 전과 술 후 사이의 임플란트 위치에 따른 변위량 검사)

  • Kim, Won;Kim, Seung-Mi;Kim, Hyo-Jung;Song, Eun-Young;Lee, Si-Ho;Oh, Nam-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.175-184
    • /
    • 2011
  • With a development of implant restoration technique, there are increasing use of computer-guided system for edentulous patients. It was carried out simulated operation based on CT information about patient's bone quantity, quality and anatomical landmark. However, there are some difference between the programmed implant and post-operative implant about it's position. If the deviation was severe, it could happen a failure of 'passive fit' and not suited for path of implant restoration. The aim of this presentation is to evaluate about a degree of deviations between programmed implant and post-operative implant. Five patients treated by 'NobelGuide' system (Nobel Biocare AB, G$\ddot{o}$teborg, Sweden) in Department of Prosthodontics, Inha University were included in this study. The patients were performed CT radiograph taking and intra-oral impression taking at pre-operation. Based on CT images and study model, surgical stent was produced by NobelBiocareTM. To fabricated a pre-operative study model, after connected lab analog to surgical template, accomplished a pre-operative model using type 4 dental stone. At final impression, a post-operative study model was fabricated in the conventional procedures. Each study model was performed CT radiograph taking. Based on CT images, each implant was simulated in three dimensional position using $Procera^{(R)}$ software (Procera Software Clinical Design Premium, version 1.5; Nobel Biocare AB). In 3D simulated model, length and angulation between each implant of both pre- and post-operative implants were measured and recorded about linear and angular deviation between pre-and post-operative implants. A total of 24 implants were included in this study and 58 inter-implant sites between each implant were measured about linear and angular deviations. In the linear deviation a mean deviation of 0.41 mm (range 0~1.7 mm) was reported. In the angular deviation, a mean deviation was $1.99^{\circ}$ (range $0^{\circ}{\sim}6.7^{\circ}$). It appears that the both linear and angular mean deviation value were well acceptable to application of computer-guided implant system.

Evaluation of the postoperative maxillary sinus with computed tomography

  • Kim Hee-Kyung;Heo Min-Suk;Lee Sam-Sun;Choi Hyun-Bae;Choi Soon-Chul;Park Tae-Won
    • Imaging Science in Dentistry
    • /
    • v.32 no.4
    • /
    • pp.195-200
    • /
    • 2002
  • Purpose: To evaluate the computed tomographic appearances of post-operative maxillary sinuses. Materials and Methods: 33 asymptomatic cases of post-operative maxillary sinus without evidence of any pathologic changes and clinical symptoms were selected. CT images were classified as opacification, soft tissue shadow, anterior wall depression, naso-antral communication, and compartmentalization. The relationships between the CT image and the age of patients at the time of operatation, and between the CT image and the duration of time elapsed since the surgical procedure were evaluated. Results: The most commonly presented radiological characteristics that occurred after the Caldwell-Luc procedure were opacification and soft tissue shadow. Anterior wall depression and naso-antral communication were radiographic indications that a Caldwell-Luc operation had been carried out. The age of patients when they had been first operated on, and the duration between the surgical procedure and the time of evaluation had no effect on the CT appearances of normal changes. In cases involving a longer time interval between the antral surgery and evaluation, the anterior wall depression with bony healing was more commonly observed than soft tissue healing. Conclusion: The radiographic information regarding the normal healing state using computed tomography can distinguish post-operative changes from inflammatory and cystic disease in patients who have undergone a Caldwell-Luc type of radical maxillary antrostomy.

  • PDF

CT Observation of Alloplastic Materials Used in Blow Out Fracture (안와골절 정복술에 사용된 인공삽입물의 전산화단층촬영 추적관찰)

  • Lee, Won;Kang, Dong-Hee
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.380-384
    • /
    • 2010
  • Purpose: Distinguishing different types of implants and assessing the position and size of implants by radiologic exam after orbital wall reconstruction is important in determining the surgery outcome and forecasting prognosis. We observed time-dependent density changes in three types of implants (porous polyethylene, resorbing plate and titanium mesh plate) by performing facial bone CT after orbital wall reconstructions. Methods: A total of 32 patients, who had underwent orbital wall fracture surgery from October 2006 to March 2009 and received facial bone CT as outpatients at 1 postoperative year were included in the study. Follow-up facial bone CT was performed on the patients pre- operatively, 1 month post-operatively, and 1 year post-operatively to observe the status of the orbital implants. Medpor $^{(R)}$ (Porex Surgical, Inc., Newnan, Ga.) was used as porous polyethylene and followed-up in 14 cases; for resorbing plate, Synthes mesh plate (Synthes, Oberdorf, Switzerland) was used in the reconstruction, and followed-up in 11 cases; and titanium mesh plate usage was followed-up in 7 cases. Computed tomographic scan (CT) and water's view were done for radiography, and hounsfield unit (HU) was used to compare density of those facial bone CT. Wilcoxon signed rank test was applied to statistically verify measurement difference in each group of hounsfield units. Results: Facial bone CT examination performed in 1 month post-operative showed that the density of porous polyethylene, resorbing plate and titanium mesh plate were -42.07, 105.67 and 539.48 on average, respectively. Among the three types of implants, titanium mesh plate showed the highest density due to its radiopaque feature. Following up the density of three types of implants in CT during 1 year after the orbital wall fracture surgery, the density of porous polyethylene increased in 10.52 House Field Units and the resorbing plate was decreased in 26.87 HouseField Units. There were no significant differences between densities in 1 month post-operatively and 1 year post-operatively in each group ($p{\geq}0.05$). Conclusion: We performed facial bone CT on patients with orbital fractures during follow-up period, distinguishing the types of implants by the different concentration of implant density, and the densities showed little change even at 1 year post-operative. To observe how implant densities change in facial bone CT, further studies with longer follow-up periods should be carried out.

Improved Clinical Staging of Esophageal Cancer with FDG-PET (양전자단층촬영술을 이용한 식도암의 병기 결정 성적 향상)

  • Kim, Young-Hwan;Choi, Joon-Young;Lee, Kyug-Soo;Choi, Yong-Soo;Lee, Eun-Jeong;Chung, Hyun-Woo;Lee, Su-Jin;Lee, Kyung-Han;Shim, Young-Mog;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.282-287
    • /
    • 2004
  • Purpose: Since preoperative staging in esophageal cancer is important in both therapy and prognosis, there had been many efforts to improve its accuracy. Recent studies indicate that whole body FDG-PET has high sensitivity in detection of metastasis in esophageal cancer. Therefore, we added FDG-PET to other conventional methods in staging esophageal cancer to evaluate the usefulness of this method. Materials & Methods: Subjects were 142 esophageal cancer patients (average $62.3{\pm}8.3$ yrs) who received CT and PET just before operation. First, we compared N stage and M stage of the CT or PET with those of the post-operative results. Then we compared the stage according to the EUS (T stage) and CT (N and M stage) or SUS (T stage) and CT & PET (N and M stage) to that according to the post-operative results. Results: Among 142 patients, surgical staging of 69 were N0 and 73 were N1. In M staging, 128 were M0 and 14 were M1. Sensitivity, specificity, and accuracy of N staging were 35.6%, 89.9%, 62.0% with CT and 58.9%, 71.0%, 64.7% with PET, respectively. In M staging, 14.3%, 96.9%, 88.7% with CT and 50.0%, 94.5%, 90.1%, with PET, respectively. The concordances of [EUS+CT] and [EUS+CT+PET] with post-operative results were 41.2% and 54.6%, respectively and there was significant improvement of staging with additional PET scan (p<0.005). Conclusion: The concordance of [EUS+CT+PET] with post-operative result was significantly increased compared to that of [EUS+CT]. Thus, the addition of FDG-PET with other conventional methods may enable more accurate preoperative staging.

Evaluation of canal preparation with Ni-Ti rotary files by micro computed tomography

  • Lee, Jeong-Ho;Kim, Mi-Ja;Seok, Chang-In;Lee, Woo-Cheol;Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.4
    • /
    • pp.378-385
    • /
    • 2004
  • The purpose of this study was to compare the effects of preparation with GT files and profiles .04 in shaping of root canals and reconstruct the three-dimensional root canal system using micro computed tomography 40 canals of the extracted human mandibular molars were used, and randomly distributed into two experimental groups. In group 1. canals were prepared by GT files. In group 2, Profiles .04. were used. Apical preparation size was #30. For each tooth pre and post operative cross-sectional images were obtained by the micro CT at 50 micron intervals. Pre and post operative cross-sectional images of 1, 2, 3, 5, and 8mm from the apex were compared. For each section. canal area and centering ratio were determined. For each tooth pre- and post-operative root canal volume from the furcation to the apex of the roots was calculated by three-dimensional image software. Following results were obtained: 1. At 8mm from the apex, area of dentin removed by GT rotary file was significantly larger than that by Profile .04. And at the other levels there was not a significant difference. 2. There was a trend for GT rotary file to remain more centered in the canals than Profile .04 at all levels. But at 3mm level. there was a statistically significant difference. 3. In root canal volume increments after instrumentation, there was no significant difference between two groups.

Transcranial Doppler and Cerebrospinal Fluid Flow Study in Normal Pressure Hydrocephalus

  • Lee, Hui-Keun;Hu, Chul;Whang, Kum;Kim, Hun-Joo
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.1
    • /
    • pp.20-25
    • /
    • 2006
  • Objective : The authors analyze prospectively the result of transcranial doppler[TCD] in normal pressure hydrocephalus and compared its cerebral blood flow parameters to radionuclide cerebrospinal fluid[CSF] flow study, postoperative brain computed tomography[CT] findings and clinical outcome, and studied the relationship between cerebral hemodynamics and clinical performance. Methods : Twenty five patients with hydrocephalus undertook pre- and post-operative TCD but only preoperative CSF flow study was performed. Mean flow velocity[Vm], pulsatility index[PI] and resistance index[RI] were assessed through TCD and changes in ventricle size and cortical gyral atrophy were checked through brain CT. Results : Postoperative hydrocephalus showed an increase in Vm[ACA P=0.037, MCA P=0.034], decrease in PI[ACA P=0.019, MCA P=0.017] and decrease in RI [ACA P=0.017, MCA P=0.021] compared to preoperative TCD parameters in the postoperative improvement group. In the postoperative improvement group, postoperative TCD parameters correlated with CSF flow study grade [Vm : $R^2=-0.75$, PI : $R^2=0.86$, RI : $R^2=0.78$] and ventriculocranial ratio change correlated with PI change [$R^2=0.73$]. The convexity gyral atrophy and initial TCD parameters showed close relationship to outcome. Conclusion : PI and RI can be used as an indicator of post operative prognosis, and with the addition of CSF flow study values, can also be used as a tool to predict pre-op and post-op patient status and successful shunt surgery.

Computer Simulation of Double Osteotomy in Tibia Using Double-Hexapod External Fixator (이중 헥사포드 외고정 기구를 이용한 선천성 왜소증 환자의 경골 교정 시뮬레이션)

  • 주상민;김윤혁
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.916-919
    • /
    • 2004
  • In this paper, we proposed a new method of pre-operative planning for tibial deformity correction using double hexapod external fixator in pseudoacondroplasia. The 3-D computer graphic model of deformed tibia was reconstructed from 3 mm sliced CT data, and CAD model of double hexapod external fixator was developed. The fixator was composed of 170 mm diameter of three rings and 90 mm of twelve struts. The bone deformities and the osteotomy lines for double osteotomy were measured using X-rays, and the necessary joint values to correct the given deformities were obtained by inverse kinematics analysis. The computer graphic simulation was performed to visualize the deformity correction process and evaluate the analysis result. By examining the pre-op and post-op X-rays, the simulation result was in good agreement with the clinical outcomes.

  • PDF

Endodermal Sinus Tumor of the Mediastinum[Yolk Sac Tumor] - A Case Report - (종격동에 발생한 내배엽 동종[난황난종]: 1례 보고)

  • 이성열
    • Journal of Chest Surgery
    • /
    • v.25 no.5
    • /
    • pp.555-561
    • /
    • 1992
  • Endodermal sinus tumor[EST] of the mediastinum is a rare germ cell neoplasm. It usually arises from the ovaries and testes but also arises from multiple extragonadal site including the mediastinum. Characteristically, alpha feto protein level is high and used for monitoring the clinical course. EST of the mediastinum is poor prognosis because of its direct invasion. The patient was 18 month old female with chief complaints of cough and fever. In the chest X-ray and CT, large encapsulated, 7x6cm sized, mass of anterior med-iastinum was found, and we could excise it completely because it was well encapsulated and not invaded but only adhered to aortic arch, pericardium and left upper lung. And confirmed it as EST by histopathology. Pre-operative alpha feto protein[AFP] level as 41,748ng/ml and decreased to 2, 663ng /ml at 14th postoperative day, 644ng /ml at 31th postoperative day. From 17th post-operative day, chemotherapy was started and keep going now.

  • PDF

Immediate Postoperative Epidural Hematomas Adjacent to the Craniotomy Site

  • Jeon, Jin-Soo;Chang, In-Bok;Cho, Byung-Moon;Lee, Ho-Kook;Hong, Seung-Koan;Oh, Sae-Moon
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.5
    • /
    • pp.335-339
    • /
    • 2006
  • Objective : The authors present eight cases of immediate post-operative epidural hematomas[EDHs] adjacent to the craniotomy site, describe clinical details of them, and discuss their pathogenesis. Methods : Medical records of eight cases were retrospectively reviewed and their clinical data, operation records, and radiological findings analyzed. Any risk factors of the EDHs were searched. Results : In 5 of 8 cases, adjacent EDHs developed after craniotomies for the surgical removal of brain tumors. Three cases of adjacent EDHs developed after a pterional approach and neck clipping of a ruptured anterior communicating artery aneurysm, a ventriculoperitoneal shunt, and a craniotomy for a post-traumatic EDH, respectively. In all eight cases, brain computed tomography[CT] scans checked immediately or a few hours after the surgery, revealed large EDHs adjacent to the previous craniotomy site, but there was no EDH beneath the previous craniotomy flap. After emergent surgical removal of the EDHs, 7 cases demonstrated good clinical outcomes, with one case yielding a poor result. Conclusion : Rapid drainage of a large volume of cerebrospinal fluid or intra-operative severe brain collapse may separate the dura from the calvarium and cause postoperative EDH adjacent to the previous craniotomy site. A high-pressure suction drain left in the epidural space may contribute to the pathogenesis. After the craniotomy for brain tumors or intracranial aneurysms, when remarkable brain collapse occurs, an immediate postoperative brain CT is mandatory to detect and adequately manage such unexpected events as adjacent EDHs.