• Title/Summary/Keyword: Post-closure

Search Result 144, Processing Time 0.026 seconds

The Assessment of Stabilization of Open-dumping Landfill Leachate - A Case Study of Noeun Landfill - (비위생매립지 침출수의 안정화 평가 - 노은매립지 사례연구 -)

  • Hong, Sang-Pyo
    • Journal of Environmental Impact Assessment
    • /
    • v.13 no.3
    • /
    • pp.115-124
    • /
    • 2004
  • To utilize a closed municipal solid waste landfill site in environmentally secure conditions, it is necessary to verify the stabilization level of landfill leachate. To assess leachate stabilization of an open-dumping municipal solid waste landfill (Noeun Landfill) which is located at the upper drainage basin of Namhan River which flows into Lake Paldang utilized for Seoul Metropolitan water supplies, the surrounding characteristics of the landfill site was surveyed. After then, leachate, groundwater and soil samples from this landfill were chemically analyzed, and the analysis results were evaluated by "The Criteria of Landfill Waste Stabilization(CLWS)", "Discharge Criteria of Landfill Leachate", "The Criteria of Domestic Use in Groundwater Quality", and "Soil Contamination Criteria" promulgated by Korean Ministry of Environment. The closed open-dumping landfill was equipped with the final soil cover, 3 groundwater monitoring wells and poor landfill gas extraction devices for the post-closure management of the landfill. BOD/CODcr ratios in leachate were less than or slightly higher than 1/10. This results seemed to imply that the leachate stabilization level of this landfill based on the CLWS was almost completed. Qualities of groundwater sampled from monitoring wells located at outside of landfill were adequate for "The Criteria of Domestic Use in Groundwater Quality". Finally, concentrations of soil contaminants that were likely to be influenced by this landfill site were adequate to "Soil Contamination Criteria".

Sensory Restoration of Abdomen after Free TRAM Flap for Breast Reconstruction

  • Sung, Kun Yong;Ahn, Hee Chang;Hwang, Weon Jung;Jo, Dong In
    • Archives of Plastic Surgery
    • /
    • v.32 no.1
    • /
    • pp.71-75
    • /
    • 2005
  • The purpose of this study is to assess abdominal sensation after free TRAM flap for breast reconstruction. 74 patients underwent breast reconstruction with free TRAM flap by authors and were followed up to check the sensation on abdomen following the surgery at the out patient clinic. They are compared with 20 female volunteer controls. Abdomens were divided into 13 zones, and assessed for superficial touch, superficial pain, temperature, two-point discrimination, and vibration. For all five sensory modalities, subjects were found to have decreased sensation in the umbilical and infraumbilical regions. This was statistically significant compared with controls. Division following pedicle dissection showed more reduction of sensation than non-dissection side. Both Inguinal areas below the donor site closure also showed markedly decreased sensation. Sensation on most area of abdomen recovered in postoperative 1 year, however, there were remained hypoesthesia in umbilical and infraumbilical area after post operative 1 year. This study clearly demonstrates that there is a significant and persistent reduction in abdominal sensibility following free TRAM flap surgery.

Pyknodysostosis: report of a rare case with review of literature

  • Ramaiah, Kiran Kumar Kotagudda;George, Giju Baby;Padiyath, Sheeba;Sethuraman, Rupak;Cherian, Babu
    • Imaging Science in Dentistry
    • /
    • v.41 no.4
    • /
    • pp.177-181
    • /
    • 2011
  • Pyknodysostosis is a rare autosomal recessive disorder characterized by the post natal onset of short limbs, short stature, and generalized hyperostosis along with acro-osteolysis with sclerosis of the terminal phalanges, a feature that is considered essentially pathognomonic. Other features include persistence of fontanelles, delayed closure of sutures, wormian bones, absence of frontal sinuses, and obtuse mandibular gonial angle with relative mandibular prognathism. We report a case of 17-year-old girl who presented with a chief complaint of retention of deciduous teeth. General physical examination demonstrated short stature, frontal and parietal bossing, depressed nasal bridge, beaked nose, hypoplastic midface, wrinkled skin over the finger tips, and nail abnormalities. Radiographs showed multiple impacted permanent and supernumerary teeth, hypoplastic paranasal sinuses with acro-osteolysis of terminal phalanges, and open fontanelles, and sutures along with wormian bones in the lambdoidal region.

AN INTEGRATED APPROACH TO RISK-BASED POST-CLOSURE SAFETY EVALUATION OF COMPLEX RADIATION EXPOSURE SITUATIONS IN RADIOACTIVE WASTE DISPOSAL

  • Seo, Eun-Jin;Jeong, Chan-Woo;Sato, Seichi
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.6-11
    • /
    • 2010
  • Embodying the safety of radioactive waste disposal requires the relevant safety criteria and the corresponding stylized methods to demonstrate its compliance with the criteria. This paper proposes a conceptual model of risk-based safety evaluation for integrating complex potential radiation exposure situations in radioactive waste disposal. For demonstrating compliance with a risk constraint, the approach deals with important exposure scenarios from the viewpoint of the receptor to estimate the resulting risk. For respective exposure situations, it considers the occurrence probabilities of the relevant exposure scenarios as their probability of giving rise to doses to estimate the total risk to a representative person by aggregating the respective risks. In this model, an exposure scenario is simply constructed with three components:radionuclide release, radionuclide migration and environment contamination, and interaction between the contaminated media and the receptor. A set of exposure scenarios and the representative person are established from reasonable combinations of the components, based on a balance of their occurrence probabilities and the consequences. In addition, the probability of an exposure scenario is estimated on the assumption that the initiating external factors influence release mechanisms and transport pathways, and its effect on the interaction between the environment and the receptor may be covered in terms of the representative person. This integrated approach enables a systematic risk assessment for complex exposure situations of radioactive waste disposal and facilitates the evaluation of compliance with risk constraints.

Mercedes Benz Pattern Craniosynostosis: A Case Report (벤츠 패턴을 가진 두개골 조기 유합증: 증례보고)

  • Ryoo, Suk-Tae;Lim, So-Young;Mun, Goo-Hyun
    • Archives of Plastic Surgery
    • /
    • v.38 no.5
    • /
    • pp.683-686
    • /
    • 2011
  • Purpose: Craniosynostosis of three or more cranial sutures was not common. "Mercedes Benz pattern," named by Moore1 was a rare form of craniosynostosis and had an atypical pattern of premature closure of cranial suture. It was not reported in Republic of Korea. We report this case with literature review. Methods: A 13-months-old male patient visited our clinic due to exophthalmos. He showed normal developmental course. Other neurological tests were normal but he was Crouzon syndrome patient. CT scans showed bilateral lambdoid and posterior sagittal sutures were fused and the length of the skull was extended. Cranioplasty with pi craniotomy & Barrel-Stave osteotomy and recombination of the bone flap was performed. Results: The patient was discharged after post operative 10 days without any complications. In follow up visit after 2.7 years, he was in good state without recurrence and functional abnormality of skull. Conclusion: This was the first case of Mercedes Benz pattern craniosynostosis with Crouzon syndrome in Korea. This type of craniosynostosis has to be considered differently from single type of craniosynostosis or typical syndromic craniosynostosis clinically and surgically.

Clinical Study of Ventricular Function Following Open Heart Surgery by Radionuclide Angiocardiogram - left ventricular ejection fraction by ECG gated blood pool scan - (방사성 동위원소를 이용한 개심술 전후의 심실기능 변화에 관한 연구: ECG gated blood pool scan을 이용한 ejection fraction 검사)

  • Lee, Jeong-Cheol;Kim, Gyu-Tae
    • Journal of Chest Surgery
    • /
    • v.19 no.1
    • /
    • pp.25-34
    • /
    • 1986
  • Recently, radionuclide angiocardiogram is one of the most common procedure for assessment of ventricular performance due to its distinctive advantages such as safety, accuracy, and ease of repeated studies. Also, measurement and comparison between pre and postoperative left ventricular ejection fraction [LVEF] are meaningful for assessing the severity of myocardial damage which occurred during open heart surgery and the status of myocardial recovery. We obtained pre and post operative LVEF using radionuclide angiocardiogram on 30 patients composed of atrial septal defect, ventricular septal defect, cyanotic congenital heart disease, and valvular heart disease who undergone the open heart surgery from March to august 1984. The study revealed that ventricular septal defect and mitral valvular heart disease showed 8.1% and 6.2% decreases of postoperative LVEF, respectively. But, there are little increases of postoperative LVEF in the atrial septal defect and cyanotic congenital heart disease. In ventricular septal defect, each group of Qp/Qs over 2.0 and systolic pulmonary artery pressure over 50mmHg showed significant 17% and 14.7% decreases of postoperative LVEF, respectively. Considering the duration of the aortic cross clamping times and closing methods of VSD, each group of duration over 30 min. and of patch closure showed 13.9% and 14.2% decreases of LVEF between pre and postoperative status respectively which was significant finding statistically.

  • PDF

Long Term Affecting Factors on Major Water Quality Items of Landfill Leachate (매립장 침출수 주요 수질항목에 대한 장기 영향요소)

  • Chun, Seung-Kyu;Kim, Min Hyuk;Won, Jong Chul
    • Journal of Soil and Groundwater Environment
    • /
    • v.26 no.1
    • /
    • pp.24-33
    • /
    • 2021
  • Analysis of long term affecting factors on water quality items of gas emission form (BOD, COD) and leachate emission form (T-N, non-bio-degradable COD (NBDCOD)) was performed for the SUDOKWON 1st Landfill Site (LS1) and 2nd Landfill Site (LS2). As landfill gas was generated, BOD and COD decreased from 6,887 and 20,025 mg/L in 1993 to 49.5 and 670.2 mg/L in 2019, respectively. TN and NBDCOD increased with waste decomposition but gradually decreased after landfill closure because of the precipitation infiltration effect. Due to the drastic decline of carbon in the leachate, the BOD/TN ratios of LS1 and LS2 declined from 13.0 and 17.0 during early stage of the landfill to 0.07 and 0.16 in 2019, respectively; LS2 and NBDCOD/COD increased from 0.25 to 0.65 during the same period. These conditions caused carbon deficiency in denitrification treatment and a chemical post-treatment request for NBDCOD. The different behaviors of gas emission and leachate emission items suggest the necessity of different strategic approaches in the long term perspective.

Deterioration of Mental Health in Children and Adolescents During the COVID-19 Pandemic

  • Eunkyung Jo;Kyoil Seo;Boram Nam;Deokyong Shin;Seohyun Kim;Youngil Jeong;Aeju Kim;Yeni Kim
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.34 no.1
    • /
    • pp.21-29
    • /
    • 2023
  • This paper reviews the global effect of the coronavirus disease 2019 (COVID-19) pandemic on the mental health of children and adolescents in South Korea, the U.S., Japan, and China. We reviewed research on deteriorated mental health, including increased suicide, suicidal thoughts, and self-harm. Various studies have shown that students' mental health issues, such as depression and anxiety, have worsened during the COVID-19 pandemic. Furthermore, the number of students who committed suicide has significantly increased in the U.S. and Japan. Factors such as prior mental health status, change in daily routine, reduced physical activity, excessive screen time, overuse of electronic devices, and reduced social support have been reported to have a significant effect. The chain of deteriorating mental health among the youth began at the onset of COVID-19, social distancing, and school closure. As youths began to stay at home instead of going to school, they lost opportunities to connect with their friends or teachers, who could provide support outside of their homes. Young people spent less time on physical activity and more time online, which damaged their sleeping schedule and daily routine. In preparing for the post-pandemic phase, we should thoroughly analyze the long-term effects of the pandemic on youth mental health, while simultaneously tackling current imminent issues.

Dorsal Mini-thoracotomy for PDA Closure in Premature Neonates (후방 소개흉술을 통한 미숙아 동맥관 개존증의 수술요법)

  • Lee, Hyang-Lim;Choi, Chang-Hyu;Son, Dong-Woo;Shim, So-Yeon;Park, Kook-Yang;Park, Chul-Hyun
    • Journal of Chest Surgery
    • /
    • v.42 no.4
    • /
    • pp.434-440
    • /
    • 2009
  • Background: Surgical closure of a patent ductus arteriosus (PDA) can be considered when conservative medical treatment is ineffective or contraindicated. Low weight and earlier gestational age neonates who are treated with conservative medical therapy generally showed a higher failure rate. The morbidity of surgical PDA closure in such extremely low birth weight (ELBW) neonates is also high. Here we present the early results of a new technique for approaching the PDA through a dorsal minithoracotomy. Material and Method: From March 2006 to November 2008, 24 premature neonates underwent surgical PDA closure. The procedures were performed in the newborn intensive care unit via a 2 cm long dorsal minithoracotomy with the baby in the prone position with the left hemithorax elevated 30$^{\circ}$. Bimanual cotton swab blunt dissection completed the extrapleural accesstothe PDA and then two clips were applied. Tube thoracostomy was avoided if there was no meaningful pleural laceration. Result: The infants mean gestational age was 26.5$\pm$2.1 weeks (range: 23 to 30 weeks) and the average age at operation was 11$\pm$11 days. The mean body weight at operation was 933$\pm$271 grams (range: 570 to 1,700 grams). Eight patients expired, but there was no procedure-related death. Postoperative echocardiography revealed two cases of residual shunt but none of these shunts were detected on the follow up echocardiogram that was performed on the post operative 5 and 59 days. Conclusion: We concluded that the technique described here is an effective procedure in view of the satisfactory operative exposure and the low rate of complications.

Uncertainty Management on Human Intrusion Scenario Assessment of the Near Surface Disposal Facility for Low and Intermediate-Level Radioactive Waste: Comparative Analysis of RESRAD and GENII (중저준위방사성폐기물 표층처분시설의 인간침입 시나리오 평가에 대한 불확실성 관리: RESRAD와 GENII의 비교분석)

  • Kim, Minseong;Hong, Sung-Wook;Park, Jin Beak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.4
    • /
    • pp.369-380
    • /
    • 2017
  • In order to manage the uncertainty about the evaluation and analysis of the human intrusion scenario of the Gyeongju Low and Intermediate Level Radioactive Waste(LILW) disposal facility, the calculation result by the GENII code was assessed using the RESRAD code, which was developed to evaluate the radiation effects of contaminated soil. The post-drilling scenario was selected as a human intrusion scenario into the near-surface disposal facility to analyze the uncertainty of the modeling by identifying any limitations in the simulation of each code and comparing the evaluation results under the same input data conditions. The results revealed a difference in the migration of some nuclides between the codes, but confirmed that the dose trends at the end of the post-closure control period were similar for all exposure pathways. Based on the results of the dose evaluation predicted by RESRAD, sensitivity analysis on the input factors was performed and major input factors were derived. The uncertainty of the modeling results and the input factors were analyzed and the reliability of the safety evaluation results was confirmed. The results of this study can be applied to the implementation 'Safety Case Program' for the Gyeongju LILW disposal facility.