• 제목/요약/키워드: Post tensioned

검색결과 196건 처리시간 0.029초

사전균열이 발생한 철근콘크리트 보의 외적 포스트텐셔닝 전단보강에서 보강깊이의 효과 (Strengthening Depth Effect in Externally Post-tensioning Shear Strengthening of Pre-cracked Reinforced Concrete Beam)

  • 이수헌;신경재;이희두
    • 대한건축학회논문집:구조계
    • /
    • 제34권11호
    • /
    • pp.19-26
    • /
    • 2018
  • This paper presents the shear strengthening effect of externally post-tensioning (EPT) method using high-strength steel rod in pre-cracked reinforced concrete (RC) beams. Three- and four-point bending tests were performed on a total of 8 specimens by adjusting the strengthening depths in the deviator position of EPT. The effective strengthening depths were 435, 535, and 610 mm. The pre-loading up to about 2/3 of ultimate load capacity measured in unstrengthened RC beam were applied in the beam to be post-tensioned. The EPT method was then applied to the pre-damaged RC beams and re-loading was added until the end of the test. EPT restored deflections of 3 mm or more, which account for about 40% of deflection when the pre-loading was applied. The shear strengthening increases more than 3 times and 36~107% in terms of the stiffness and load-carrying capacity compared to unstrengthening RC beams. The increased load-carrying capacities of the post-tensioned beam with strengthening depths of 435 and 535 mm are almost the same as 36~61%, and those of 610 mm are 84~107%, which shows the greatest shear strengthening effect.

포스트 텐션 플랫 플레이트 외부 접합부의 내진 거동 (Seismic Behaviour of Exterior Joints in Post-Tensioned Flat Plate Systems)

  • 한상환;기성훈;강현구;조종;이리형
    • 콘크리트학회논문집
    • /
    • 제18권5호
    • /
    • pp.595-602
    • /
    • 2006
  • 본 연구의 목적은 중력 하중에 저항하도록 설계된 플랫 플레이트 외부 접합부의 이력 거동을 평가하는 데 있다. 이러한 목적을 위하여 2/3의 크기가 조정된 PT 슬래브-기둥 외부 접합부 2개와 RC 슬래브-기둥 외부 접합부 1개를 대상으로 실험적 연구를 수행하였다. 여기서 각각의 PT 실험체는 서로 다른 강선 배치 형태를 띄고 있다. 중력 하중은 동일하게 설정하였고, 지속적인 정적 하중 하에서 유사 정적 횡하중을 적용하였다. 한편 모든 실험체는 ACI 318-05과 ACI 352.1R-89에 근거하여 기둥 폭 내에 하부 철근을 배근 하였다. 또한 PT 외부 접합부의 이력 거동에 대한 일반적인 결론을 얻기 위하여 기존 연구자들의 실험 결과와 함께 비교하였다. 이번 연구를 통하여 강선의 배치는 PT 접합부의 이력 거동을 결정하는 중요한 변수임을 확인하였다. 즉 횡변형 성능, 에너지 소산 능력, 파괴 메커니즘, 그리고 연성 능력이 강선의 배치에 따라 다르게 나타났다. 또한 ACI 352.1R-89에서 구조적 일체성을 위해 제공된 하부 철근의 양은 모멘트 역전에 의해 발생된 정모멘트를 저항하는데 있어서도 적절하다는 것이 밝혀졌다. 또한 실험체의 전단 강도는 강선의 포스트 텐션에 의한 평균 콘크리트 압축 응력($f_{pc}$)의 효과가 고려된 식이 그렇지 않은 식보다 전단 강도를 정확히 예측하는 것으로 나타났다.

Influence of Removed Web Members in Shaping Formation for Hypar Space Truss

  • 김진우
    • 한국해양공학회지
    • /
    • 제20권2호
    • /
    • pp.16-21
    • /
    • 2006
  • This paper discusses the behavior of post-tensioned and shaped hypar space truss, with consideration of the influence of removing some web members. Hypar space truss is post-tensioned at the bottom chords of one diagonal on the ground; the essential behavior characteristic of shape formation is discussed by using a small-scale test model. Results of experiments and nonlinear finite-element analysis indicate that a planar, rectangular- arranged structure can be deformed to a predicted hyper shape, by the proposed shape formation method. Also the feasibility of the proposed method for furnishing of a hypar shaped face truss has been presented, under the condition of both non-removed and partially removed web members. It follows that a nonlinear finite element analysis method can be used in predicting the behavior of the space shape and the post-tensioning force in sharing of hypar space truss. Further, in comparison to the other cases, the results of test and analysis show that the active diagonal shaping in the non-removed web members and passive diagonal shaping of partially removed web members are in relatively good agreement.

Snap back testing of unbonded post-tensioned concrete wall systems

  • Twigden, Kimberley M.;Henry, Richard S.
    • Earthquakes and Structures
    • /
    • 제16권2호
    • /
    • pp.209-219
    • /
    • 2019
  • Unbonded Post-Tensioned (UPT) precast concrete systems have been shown to provide excellent seismic resistance. In order to improve understanding of the dynamic response of UPT systems, a series of snap back tests on four UPT systems was undertaken consisting of one Single Rocking Wall (SRW) and three Precast Wall with End Columns (PreWEC) systems. The snap back tests provided both a static pushover and a nonlinear free vibration response of a system. As expected the SRW exhibited an approximate bi-linear inertia force-drift response during the free vibration decay and the PreWEC walls showed an inertia force-drift response with increased strength and energy dissipation due to the addition of steel O-connectors. All walls exhibited negligible residual drifts regardless of the number of O-connectors or the post-tensioning force. When PreWEC systems of the same strength were compared the inclusion of further energy dissipating O-connectors was found to decrease the measured peak wall acceleration. Both the local and global wall parameters measured at pseudo-static and dynamic loading rates showed similar behaviour, which demonstrates that the dynamic behaviour of UPT walls is well represented by pseudo-static tests. The SRW was found to have Equivalent Viscous Damping (EVD) between 0.9-3.8% and the three PreWEC walls were found to have maximum EVD of between 14.7-25.8%.

하이브리드 프리스트레스트 프리캐스트 콘크리트 구조시스템의 부모멘트 영역 휨거동 (Flexural Response of Negative Moment Region of Hybrid Prestressed Precast Concrete (HPPC) System)

  • 최승호;황진하;허인욱;김강수;우운택
    • 대한건축학회논문집:구조계
    • /
    • 제34권10호
    • /
    • pp.3-10
    • /
    • 2018
  • Hybrid Prestressed Precast Concrete System (HPPC system) is a newly developed frame system that can improve the performance of precast concrete (PC) joints by post-tensioning. In particular, the details proposed in this study can reduce the lifting weight of the PC members and eliminate problems caused by cracks in the joints that occur under service loads. This study performed an evaluation on the negative moment performance of full-scaled HPPC girders. The test specimens were cast with or without slabs, with bonded or unbonded tendons, and had different post-tensioned lengths in tensile section. The test results showed that the specimens with slabs had significantly higher stiffness and strength than those without slabs. There were no differences in the flexural behavior between those with bonded or unbonded tendons, and between those with short or long post-tensioned lengths in the negative moment region.

포스트텐션을 도입한 넓은 보에서 기둥 폭 내부에 배근된 보강재의 정착비에 따른 비탄성 거동 평가 (Inelastic Behavior of Post-tensioned Wide Beam System with different Reinforcement ratios within Column core)

  • 최윤철;임재형;문정호;이리형;권기혁
    • 콘크리트학회논문집
    • /
    • 제17권1호
    • /
    • pp.85-94
    • /
    • 2005
  • PPS(post-tensioned precast concrete system)공법은 U자형 PC로 제작한 넓은 보와 PC 또는 현장 타설 콘크리트로 제작한 기둥으로 구성되며 PC 보와 기둥의 일체성 확보를 위하여 프리스트레스를 도입하였다. 본 연구는 PPS 공법 개발의 일부로 넓은 보의 기둥 폭 내부에 정착되어진 휨철근의 양에 따른 거동특성을 분석하고자 실험적 연구를 수행하였다. 실험체는 기둥 폭내, 외부에 위치한 휭 철근의 양을 달리한 정착비와 동일한 정착비내에서 철근과 긴장재의 양을 주요변수로 하여 대상건물의 내부접합부를 대상으로 1/2크기로 제작하였다. 그 결과 NEHRP 권고사항에서 규정한 한계변위각 0.035까지 내력저하 없이 충분한 내력을 보유하였으며, 보의 휨 파괴가 주요 파괴모드로 접합부에서 전단파괴는 일어나지 않았다. 그리고 넓은 보에 포스트텐션을 도입한 PPS 공법은 기둥 폭 내부의 정착비가 $35\%$인 경우 다소 높은 비틀림 응력을 나타내었으나, 기둥 폭 외부에 위치한 인장철근의 항복 이후 긴장재가 응력을 충분히 발휘함으로서 일체식 구조의 넓은 보-기둥 접합부와 달리 비탄성 이력거동을 통하여 에너지를 효과적으로 소산하였다. 또한 ACI의 proposed provisional standard의 PC 접합부 구조성능 평가지침에 의해 분석한 결과, 모든 실험체에서 허용기준을 모두 만족하고 있으며, 강도의 큰 저하 없이 연성적인 거동을 하고 있음을 알 수 있었다.

포스트텐션 콘크리트 포장의 시험시공 (Experimental Construction of Post-Tensioned Concrete Pavement)

  • 김동호;이현호;배종오;김기헌
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.135-136
    • /
    • 2009
  • 국내에서 처음으로 포스트텐션 콘크리트 포장의 시험시공이 2008년 10월 13일 수행되었다. 슬래브의 길이가 120m이며, 두께는 15cm의 폭 8.2m로 시공되었다. 본 시험시공을 통하여 포스트텐션 콘크리트포장(PTCP) 공법의 설계와 해석, 시공 등을 경험하였고 많은 실험데이터가 수집되었다. 또한 본 연구의 주요결과를 요약하였다.

  • PDF

포스트텐션 콘크리트 포장에서 고내구성 콘크리트의 적용 (Application of High Durable Concrete in Post-Tensioned Concrete Pavement)

  • 최판길;이봉학;정범석;김동호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.435-436
    • /
    • 2009
  • 본 논문의 목적은 PTCP포장공법에 적용하기 위하여 실리카흄과 플라이애시가 혼합된 고성능 콘크리트를 개발하는 것이다. 실험결과 실리카흄 혼입에 따라 조기재령 압축강도가 증진되었고, 투수저항성이 ASTM C 1202 기준 "Low"에서 "Very Low" 등급으로 향상되었다.

  • PDF

포스트 텐션 플랫 플레이트 해석을 위한 강성감소계수 (Stiffness Reduction Factor for Post-Tensioned Flat Plate Slabs)

  • 박영미;박진아;한상환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.125-126
    • /
    • 2009
  • 유효보폭 모델은 횡하중하의 포스트 텐션(PT) 플랫 플레이트 골조 해석에 사용된다. PT 플랫 플레이트의 정확한 해석을 위해서 슬래브의 강성감소는 정확하게 평가되어야 한다. 이 목적을 위하여 본 연구는 기존 연구자들의 PT 플랫 플레이트 실험체를 수집하였으며. 반복적인 작업으로 실험체 강성에 수렴하는 유효보폭모델의 강성을 찾기 위하여 슬래브 폭을 감소시켰다. 이러한 데이터를 수집하여 비선형 회귀분석을 통하여 PT 플랫 플레이트의 강성 감소 계수식을 제안하였다.

  • PDF