• Title/Summary/Keyword: Post removal

Search Result 441, Processing Time 0.026 seconds

Method for contaminant removal from leachate induced by buried livestock carcasses (매몰 사축에 의한 침출수내 오염물질 제거 방법)

  • Haeseong Jeon;Joonkyu Park;Geonha Kim
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.6
    • /
    • pp.395-408
    • /
    • 2023
  • This study presents a novel method for addressing the issue of high-concentration contaminants (ammonium, phosphate, antibiotics) in leachate arising from decomposing livestock carcasses. Antibiotics, developed to eliminate microorganisms, often have low biodegradability and can persist in the ecosystem. This research proposes design elements to prevent contamination spread from carcass burial sites. The adsorbents used were low-grade charcoal (an industrial by-product), Alum-based Adsorbent (ABA), and Zeolite, a natural substance. These effectively removed the main leachate contaminants: low-grade charcoal for antibiotics (initial concentration 1.05 mg/L, removal rate 73.4%), ABA for phosphate (initial concentration 2.53 mg/L, removal rate 99.9%), and zeolite for ammonium (initial concentration 38.92 mg/L, removal rate 100.0%). The optimal mix ratio for purifying leachate is 1:1:10 of low-grade charcoal, ABA, and zeolite. The average adsorbent usage per burial site was 1,800 kg, costing KRW 2,000,000 per ton. The cost for the minimum leachate volume (about 12.4 m3) per site is KRW 2,880,000, and for the maximum volume (about 19.7 m3) is KRW 4,620,000. These findings contribute to resolving issues related to livestock carcass burial sites and suggest post-management strategies by advocating for the effective use of adsorbents in leachate purification.

Evaluation of the Nutrient Removal Performance of the Pilot-scale KNR (Kwon's Nutrient Removal) System with Dual Sludge for Small Sewage Treatment (소규모 하수처리를 위한 파일럿 규모 이중슬러지 KNR® (Kwon's nutrient removal) 시스템의 영얌염류 제거성능 평가)

  • An, Jin-Young;Kwon, Joong-Chun;Kim, Yun-Hak;Jeng, Yoo-Hoon;Kim, Doo-Eon;Ryu, Sun-Ho;Kim, Byung-Woo
    • Clean Technology
    • /
    • v.12 no.2
    • /
    • pp.67-77
    • /
    • 2006
  • A simple dual sludge process, called as $KNR^{(R)}$ (Kwon's Nutrient Removal) system, was developed for small sewage treatment. It is a hybrid system that consists of an UMBR (Upflow multi-layer bioreactor) as anaerobic and anoxic reactor with suspended denitrifier and a post aerobic biofilm reactor, filled with pellet-like media, with attached nitrifier. To evaluate the stability and performance of this system for small sewage treatment, the pilot-scale $KNR^{(R)}$ plant with a treatment capacity of $50m^3/d$ was practically applied to the actual sewage treatment plant, which was under retrofit construction during pilot plant operation, with a capacity of $50m^3/d$ in a small rural community. The HRTs of a UMBR and a post aerobic biofilm reactor were about 4.7 h and 7.2 h, respectively. The temperature in the reactor varied from $18.1^{\circ}C$ to $28.1^{\circ}C$. The pilot plant showed stable performance even though the pilot plant had been the severe fluctuation of influent flow rate and BOD/N ratio. During a whole period of this study, average concentrations of $COD_{cr}$, $COD_{Mn}$, $BOD_5$, TN, and TP in the final effluent obtained from this system were 11.0 mg/L, 8.8 mg/L, 4.2 mg/L, 3.5 mg/L, 9.8 mg/L, and 0.87/0.17 mg/L (with/without poly aluminium chloride(PAC)), which corresponded to a removal efficiency of 95.3%, 87.6%, 96.3%, 96.5%, 68.2%, and 55.4/90.3%, respectively. Excess sludge production rates were $0.026kg-DS/m^3$-sewage and 0.220 kg-DS/kg-BOD lower 1.9 to 3.8 times than those in activated sludge based system such as $A_2O$ and Bardenpho.

  • PDF

Performance Analysis of Upgrading Process with Amine-Based CO2 Capture Pilot Plant

  • Kwak, No-Sang;Lee, Junghyun;Lee, Dong Woog;Lee, Ji Hyun;Shim, Jae-Goo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.4 no.1
    • /
    • pp.33-38
    • /
    • 2018
  • This study applied upgrades to the processes of a 10 MW wet amine $CO_2$ capture pilot plant and conducted performance evaluation. The 10 MW $CO_2$ Capture Pilot Plant is a facility that applies 1/50 of the combustion flue gas produced from a 500 MW coal-fired power plant, and is capable of capturing up to 200 tons of $CO_2$. This study aimed to quantitatively measure efficiency improvements of post-combustion $CO_2$ capture facilities resulting from process upgrades to propose reliable data for the first time in Korea. The key components of the process upgrades involve absorber intercooling, lean/rich amine exchanger efficiency improvements, reboiler steam TVR (Thermal Vapor Recompression), and lean amine MVR (Mechanical Vapor Recompression). The components were sequentially applied to test the energy reduction effect of each component. In addition, the performance evaluation was conducted with the absorber $CO_2$ removal efficiency maintained at the performance evaluation standard value proposed by the IEA-GHG ($CO_2$ removal rate: 90%). The absorbent used in the study was the highly efficient KoSol-5 that was developed by KEPCO (Korea Electric Power Corporation). From the performance evaluation results, it was found that the steam consumption (regeneration energy) for the regeneration of the absorbent decreased by $0.38GJ/tonCO_2$ after applying the process upgrades: from $2.93GJ/ton\;CO_2$ to $2.55GJ/tonCO_2$. This study confirmed the excellent performance of the post-combustion wet $CO_2$ capture process developed by KEPCO Research Institute (KEPRI) within KEPCO, and the process upgrades validated in this study are expected to substantially reduce $CO_2$ capture costs when applied in demonstration $CO_2$ capture plants.

Immediate Postoperative Epidural Hematomas Adjacent to the Craniotomy Site

  • Jeon, Jin-Soo;Chang, In-Bok;Cho, Byung-Moon;Lee, Ho-Kook;Hong, Seung-Koan;Oh, Sae-Moon
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.5
    • /
    • pp.335-339
    • /
    • 2006
  • Objective : The authors present eight cases of immediate post-operative epidural hematomas[EDHs] adjacent to the craniotomy site, describe clinical details of them, and discuss their pathogenesis. Methods : Medical records of eight cases were retrospectively reviewed and their clinical data, operation records, and radiological findings analyzed. Any risk factors of the EDHs were searched. Results : In 5 of 8 cases, adjacent EDHs developed after craniotomies for the surgical removal of brain tumors. Three cases of adjacent EDHs developed after a pterional approach and neck clipping of a ruptured anterior communicating artery aneurysm, a ventriculoperitoneal shunt, and a craniotomy for a post-traumatic EDH, respectively. In all eight cases, brain computed tomography[CT] scans checked immediately or a few hours after the surgery, revealed large EDHs adjacent to the previous craniotomy site, but there was no EDH beneath the previous craniotomy flap. After emergent surgical removal of the EDHs, 7 cases demonstrated good clinical outcomes, with one case yielding a poor result. Conclusion : Rapid drainage of a large volume of cerebrospinal fluid or intra-operative severe brain collapse may separate the dura from the calvarium and cause postoperative EDH adjacent to the previous craniotomy site. A high-pressure suction drain left in the epidural space may contribute to the pathogenesis. After the craniotomy for brain tumors or intracranial aneurysms, when remarkable brain collapse occurs, an immediate postoperative brain CT is mandatory to detect and adequately manage such unexpected events as adjacent EDHs.

Analysis of Neurotoxins, Anatoxin-a, Saxitoxin in Algae Cultured and Algae in Dam Reservoir and its Water Treatment (배양조류 및 댐 저수지 조체중 신경독소 Anatoxin-a, Saxitoxin류의 분석 및 수처리방안)

  • Kim, Hak-Chul;Choi, Il-Whan
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.4
    • /
    • pp.37-44
    • /
    • 2008
  • In this study we developed the analytical methods for the determination of three neurotoxin; anatoxin-a, saxitoxin and neosaxitoxin using HPLC/FLD system and this analytical methods were applied to real sample; algae culture and algae extracts. For the HPLC/FLD analysis of anatoxin-a samples were concentrated on WCX(Weak Cation Exchanger) SPE and then anatoxin-a in concentrate was derivatized with NBD-F solution. Supernatant was injected on HPLC system. For the HPLC/FLD analysis of saxitoxin and neosaxitoxin samples were separated on the column and then derivatizied by post column reactor for fluorescen detection. For post column reaction of saxitoxin we feed two kinds of reaction solution; Oxidizing Reagent of which composition was periodic acid(7mM) in 50mM potassium phosphate buffer, pH 9 and acidifying reagent of which Composition was 0.5M acetic acid. The LOD value for anatoxin-a, saxitoxin and neosaxitoxin in HPLC/FLD method was 24.3 ng. $35{\mu}g/L$, $27{\mu}g/L$ respectively. We determined the anatoxin-a content of lyophilized anabaena flos-aquae and $20{\mu}g/g$ d.w. of anatoxin-a was detected. We analyzed saxitoxin and neosaxitoxin in algae culture media and extracts of lypopyllized algal cell cultured and that of Deachung reservior. Saxitoxin and neosaxitoxin in real sample were below the limit of detection. Although there are various water treatment processes for removing neurotoxins were suggested no process give simultaneous and complete removal of neurotoxins. It was cocluded that nanofiltration which reject material by size can be a process for removal of neurotoxins.

Admittance Model-Based Nanodynamic Control of Diamond Turning Machine (어드미턴스 모델을 이용한 다이아몬드 터닝머시인의 초정밀진동제어)

  • Jeong, Sanghwa;Kim, Sangsuk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.10
    • /
    • pp.154-160
    • /
    • 1996
  • The control of diamond turning is usually achieved through a laser-interferometer feedback of slide position. The limitation of this control scheme is that the feedback signal does not account for additional dynamics of the tool post and the material removal process. If the tool post is rigid and the material removal process is relatively static, then such a non-collocated position feedback control scheme may surfice. However, as the accuracy requirement gets tighter and desired surface cnotours become more complex, the need for a direct tool-tip sensing becomes inevitable. The physical constraints of the machining process prohibit any reasonable implementation of a tool-tip motion measurement. It is proposed that the measured force normal to the face of the workpiece can be filtered through an appropriate admittance transfer function to result in the estimated dapth of cut. This can be compared to the desired depth of cut to generate the adjustment control action in additn to position feedback control. In this work, the design methodology on the admittance model-based control with a conventional controller is presented. The recursive least-squares algorithm with forgetting factor is proposed to identify the parameters and update the cutting process in real time. The normal cutting forces are measured to identify the cutting dynamics in the real diamond turning process using the precision dynamoneter. Based on the parameter estimation of cutting dynamics and the admitance model-based nanodynamic control scheme, simulation results are shown.

  • PDF

Glutamic Acid-Grafted Metal-Organic Framework: Preparation, Characterization, and Heavy Metal Ion Removal Studies

  • Phani Brahma Somayajulu Rallapalli;Jeong Hyub Ha
    • Applied Chemistry for Engineering
    • /
    • v.34 no.5
    • /
    • pp.556-565
    • /
    • 2023
  • Fast industrial and agricultural expansion result in the production of heavy metal ions (HMIs). These are exceedingly hazardous to both humans and the environment, and the necessity to eliminate them from aqueous systems prompts the development of novel materials. In the present study, a UIO-66 (COOH)2 metal-organic framework (MOF) containing free carboxylic acid groups was post-synthetically modified with L-glutamic acid via the solid-solid reaction route. Pristine and glutamic acid-treated MOF materials were characterized in detail using several physicochemical techniques. Single-ion batch adsorption studies of Pb(II) and Hg(II) ions were carried out using pristine as well as amino acid-modified MOFs. We further examined parameters that influence removal efficiency, such as the initial concentration and contact time. The bare MOF had a higher ion adsorption capacity for Pb(II) (261.87 mg/g) than for Hg(II) ions (10.54 mg/g) at an initial concentration of 150 ppm. In contrast, an increased Hg(II) ion adsorption capacity was observed for the glutamic acid-modified MOF (80.6 mg/g) as compared to the bare MOF. The Hg(II) ion adsorption capacity increased by almost 87% after modification with glutamic acid. Fitting results of isotherm and kinetic data models indicated that the adsorption of Pb(II) on both pristine and glutamic acid-modified MOFs was due to surface complexation of Pb(II) ions with available -COOH groups (pyromellitic acid). Adsorption of Hg(II) on the glutamic acid-modified MOF was attributed to chelation, in which glutamic acid grafted onto the surface of the MOF formed chelates with Hg(II) ions.

A Case Report of Voiding Dysfunction after Intracerebral Hemorrhage in CKD Patient Improved with Yeoldahanso-tanggamibang (만성 신부전환자의 뇌출혈 후 배뇨곤란에 대한 열다한소탕가미방 치험례)

  • Won Kyoung Moon;Sang Woo Park;Hyun Ji Yoo;Eui Ju Lee
    • Journal of Sasang Constitutional Medicine
    • /
    • v.36 no.2
    • /
    • pp.65-75
    • /
    • 2024
  • Objectives This case study was aimed to report improvement of taeum-in patient with chronic kidney disesase who had voiding dysfunction after intracerebral hemorrhage using Yeoldahanso-tanggamibang. Methods A patient who complained of voiding dysfunction after intracerebral hemorrhage was administered with Yeoldahanso-tanggamibang through sasang consitutional medicine approach. To evaluate the improvement of voiding dysfunction, the number of nelaton catheterizations after removal of foley catheter and the amount of post void residual volume were compared, and laboratory follow-up was performed to determine whether renal function deteriorated. Results After treatment with Yeoldahanso-tanggamibang for 8 weeks, the number of nelaton catheterizations after removal of foley catheter decreased, the amount of post void residual volume decreased, and the renal function did not change. Conclusions This case study suggests the significance of Yeoldahanso-tanggamibang treatment for taeum-in patient who had voiding dysfunction after intracerebral hemorrhage.

A Study on the Removal of Organics and Nutrients in the Process Using Attached Biomass and Aquatic Floating Plants (부착미생물과 부유수생식물을 이용한 공정에서 유기물 및 영양염류 제거에 관한 연구)

  • Seon, Yong-Ho
    • KSBB Journal
    • /
    • v.23 no.4
    • /
    • pp.323-328
    • /
    • 2008
  • This study was accomplished using Anaerobic/Anoxic/Oxic biofilm reactors with fixed media and post-treatment reactor for natural purification with aquatic floating plants. The objectives of this study was to investigate the characteristics of organics, nitrogen and phosphorus removal from sewage with the HRT. The average removal efficiency of SS and $COD_{Cr}$ increases as increasing the hydraulic retention time (HRT) until 12 hr of the HRT, and it was constant over 12 hr of the HRT. The removal efficiency of them was about 93% and 89% respectively over the 12 hr of HRT. The average $BOD_5$ and $COD_{Mn}$ increases as increasing the HRT and the removal efficiency of them was 84.91 % and 76.03% respectively at the 26 hr of HRT. The removal efficiency of T-N and T-P increases as increasing the HRT until 61 hr of the HRT, and it was constant over 61 hr of the HRT. At the HRT of 61 hr, it was 70.20%, 77.86% respectively. It was found that the optimum HRT was 61 hr in case of the nutrients. Before and after experiment, the nitrogen content was similar in leaves of the water hyacinths but the nitrogen content in roots after experiment was 5.5% more than its content before experiment. It was known that the nitrogen was absorbed by the water hyacinths.

Evaluation of Filter-Adsorber(F/A) Process for Removal of Disinfection By-products(DBPs) (소독부산물 제어를 위한 실공정 F/A 운영에 관한 고찰)

  • Kim, Seong-Su;Lee, Kyung-Hyuk;Lim, Jae-Lim;Chae, Seon-Ha;Kang, Byeong-Soo;Moon, Pil-Joong;Ahn, Hyo-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.10
    • /
    • pp.1035-1042
    • /
    • 2005
  • Granular Activated Carbon(GAC) is widely used in drinking water treatment. At S and B Water Treatment Plant, GAC is used in place of granular media in conventional rapid filters(GAC Filter-Adsorber) for removal of Disinfection By-products(DBPs). The primary focus of this study is on the performance of existing filter-adsorber, and their operation. It was found that F/A process removed turbidity as effective as sand system. The ratio of Hydrophobic DOM (HPO) and hydrophilic DOM (HPI) fraction in the raw water at S and B WTP was similar. Filter Adsorber presented earlier DOC breakthrough and steady state condition which was contributed by biodegradation during operation period. The removal efficiency of DBPs were used to evaluate the filter performance. The DBPs concentration of F/A treated water was below treatment goal level (THM < $80\;{\mu}g/L$, HAA < $60{\mu}g/L$). The removal efficiency of THM decreased rapidly during operation period. However, HAA were removed steadily regardless of the influent concentration of HAA. These results indicate that the removal of THM depend upon the adsorption mechanism while the removal of HAA depend upon biodegradation as well as adsorption. The decrease of adsorption capacity and characteristic value of GAC may be attributed to the effect of high organic loading, residual free chlorine, coagulants, manganese oxidants and frequently backwashing. This study has confirmed that Filter adsorber process can be considered as effective alternatives for the removal of DBPs, especially HAA.