• Title/Summary/Keyword: Positive sequence

Search Result 874, Processing Time 0.024 seconds

Effect of antioxidation and antibacterial activity on crude extract and Characterization of American Cockroaches (Periplaneta americana L.) in Korea (국내 서식 미국바퀴(Periplaneta americana L.)의 특성 및 추출물의 항산화·항균 효과)

  • Kim, Jung-Eun;Kim, Seon-Gon;Kang, Sung-Ju;Kim, Chun-Sung;Choi, Yong-Soo
    • Journal of Sericultural and Entomological Science
    • /
    • v.53 no.2
    • /
    • pp.135-142
    • /
    • 2015
  • The American cockroaches, Periplaneta americana L. was the most important worldwide pest species. It has been an public health problems. We were determinated life cycle and extraction of crude extracts by chemical reagents from cockraches (P. americana L.). The extracted crude solution has been antibacterial activity to gram negative bacteria (Pseudomonas aeruginosa, $6.44{\pm}1.03mm$), gram positive bacteria (Bacillus subtilis, $1.88{\pm}0.40mm$), and fungus (Candida albicans, $5.61{\pm}0.57mm$) using radial diffusion assay. We were analysed of up-regulation of Glutathione-S-transferases (GSTs) stimulation, indicating that antioxidantial protein from various classes are simultaneously expressed in a single insect upon infection or injury. The gene from Periplaneta americana L. were cloned, analysed sequence, and measured protein expression by Real Time PCR (Polymerase Chain Reaction).

Reduction of Artifacts in Magnetic Resonance Imaging with Diamagnetic Substance (반자성 물질을 이용한 자기공명영상검사에서의 인공물 감소)

  • Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.581-588
    • /
    • 2019
  • MRI is superior when contrasted to help the organization generate artifacts resolution, but also affect the diagnosis and create a image that can not be read. Metal is inserted into the tooth, it is necessary to often be inhibited in imaging by causing the geometric distortion due to the majority and if the difference between the magnetic susceptibility of a ferromagnetic material or paramagnetic reducing them. The purpose of this study is to conduct a metal artefact in accordance with the analysis using a diamagnetic material. The magnetic material include a wire for the orthodontic bracket and a stainless steel was used as a diamagnetic material was used copper, zinc, bismuth. Testing equipment is sequenced using 1.5T, 3T was used was measured using a SE, TSE, GE, EPI. A self-produced phantom material was used for agarose gel (10%) to a uniform signal artifacts causing materials are stainless steel were tested by placing in the center of the phantom and cover inspection of the positive cube diamagnetic material of 10mm each length.After a measurement artefact artifact zone settings area was calculated using the Wand tool After setting the Low Threshold value of 10 in the image obtained by subtracting images, including magnetic material from a pure tool phantom images using Image J. Metal artifacts occur in stainless steel metal artifact reduction was greatest in the image with the bismuth diamagnetic materials of copper and zinc is slightly reduced, but the difference in degree will not greater. The reason for this is thought to be due to hayeotgi offset most of the susceptibility in bismuth diamagnetic susceptibility of most small ferromagnetic. Most came with less artifacts in image of bismuth in both 1.5T and 3T. Sequence-specific artifact reduction was most reduced artifacts from the TSE 1.5T 3T was reduced in the most artifacts from SE. Signal-to-noise ratio was the lowest SNR is low, appears in the implant, the 1.5T was the Implant + Bi Cu and Zn showed similar results to each other. Therefore, the results of artifacts variation of diamagnetic material, magnetic susceptibility (${\chi}$) is the most this shows the reduced aspect lower than the implant artificial metal artifacts criteria in the video using low bismuth susceptibility to low material the more metal artifacts It was found that the decrease. Therefore, based on the study on the increase, the metal artifacts reduction for the whole, as well as dental prosthesis future orthodontic materials in a way that can even reduce the artifact does not appear which has been pointed out as a disadvantage of the solutions of conventional metal artifact It is considered to be material.

Correlation of p53 Protein Overexpression, Gene Mutation with Prognosis in Resected Non-Small Cell Lung Cancer(NSCLC) Patients (비소세포폐암에서 p53유전자의 구조적 이상 및 단백질 발현이 예후에 미치는 영향)

  • Lee, Y.H.;Shin, D.H.;Kim, J.H.;Lim, H.Y.;Chung, K.Y.;Yang, W.I.;Kim, S.K.;Chang, J.;Roh, J.K.;Kim, S.K.;Lee, W.Y.;Kim, B.S.;Kim, B.S.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.4
    • /
    • pp.339-353
    • /
    • 1994
  • Background : The p53 gene codes for a DNA-binding nuclear phosphoprotein that appears to inhibit the progression of cells from the G1 to the S phase of the cell cycle. Mutations of the p53 gene are common in a wide variety of human cancers, including lung cancer. In lung cancers, point mutations of the p53 gene have been found in all histological types including approximately 45% of resected NSCLC and even more frequently in SCLC specimens. Mutant forms of the p53 protein have transforming activity and interfere with the cell-cycle regulatory function of the wild-type protein. The majority of p53 gene mutations produce proteins with altered conformation and prolonged half life; these mutant proteins accumulate in the cell nucleus and can be detected by immunohistochemical staining. But protein overexpression has been reported in the absence of mutation. p53 protein overexpression or gene mutation is reported poor prognostic factor in breast cancer, but in lung cancer, its prognostic significance is controversial. Method : We investigated the p53 abnormalities by nucleotide sequencing, polymerase chain reaction-single strand conformation polymorphism(PCR-SSCP), and immunohistochemical staining. We correlated these results with each other and survival in 75 patients with NSCLC resected with curative intent. Overexpression of the p53 protein was studied immunohistochemically in archival paraffin- embedded tumor samples using the D07(Novocastra, U.K.) antibody. Overexpression of p53 protein was defined by the nuclear staining of greater than 25% immunopositive cells in tumors. Detection of p53 gene mutation was done by PCR-SSCP and nucleotide sequencing from the exon 5-9 of p53 gene. Result: 1) Of the 75 patients, 36%(27/75) showed p53 overexpression by immunohistochemical stain. There was no survival difference between positive and negative p53 immunostaining(overall median survival of 26 months, disease free median survival of 13 months in both groups). 2) By PCR-SSCP, 27.6%(16/58) of the patients showed mobility shift. There was no significant difference in survival according to mobility shift(overall median survival of 27 in patients without mobility shift vs 20 months in patients with mobility shift, disease free median survival of 8 months vs 10 months respectively). 3) Nucleotide sequence was analysed from 29 patients, and 34.5%(10/29) had mutant p53 sequence. Patients with the presence of gene mutations showed tendency to shortened survival compared with the patients with no mutation(overall median survival of 22 vs 27 months, disease free median survival of 10 vs 20 months), but there was no statistical significance. 4) The sensitivity and specificity of immunostain based on PCR-SSCP was 67.0%, 74.0%, and that of the PCR-SSCP based on the nucleotide sequencing was 91.8%, 96.2% respectively. The concordance rate between the immunostain and PCR-SSCP was 62.5%, and the rate between the PCR-SSCP and nucleotide sequencing was 95.3%. Conclusion : In terms of detection of p53 gene mutation, PCR-SSCP was superior to immunostaining. p53 gene abnormalities either overexpression or mutation were not a significant prognostic factor in NSCLC patients resected with curative intent. However, patients with the mutated p53 gene showed the trends of early relapse.

  • PDF

Evaluation of Parameters of Gas Exchange During Partial Liquid Ventilation in Normal Rabbit Lung (토끼의 정상 폐 모델에서 부분액체환기 시 가스교환에 영향을 주는 인자들에 대한 연구)

  • An, Chang-Hyeok;Koh, Young-Min;Park, Chong-Wung;Suh, Gee-Young;Koh, Won-Jung;Lim, Sung-Yong;Kim, Cheol-Hong;Ahn, Young-Mee;Chung, Man-Pyo;Kim, Ho-Joong;Kwon, O-Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.1
    • /
    • pp.14-23
    • /
    • 2002
  • Background: The opitmal ventilator setting during partial liquid ventilation(PLV) is controversial. This study investigated the effects of various gas exchange parameters during PLV in normal rabbit lungs in order to aid in the development of an optimal ventilator setting during PLV. Methods: Seven New-Zealand white rabbits were ventilated in pressure-controlled mode with the following settings; tidal volume($V_T$) 8 mL/kg, positive end-expiratory pressure(PEEP) 4 $cmH_2O$, inspiratory-to-expiratory ratio(I:E ratio) 1:2, fraction of inspired oxygen($F_TO_2$) 1.0. The respiration rate(RR) was adjusted to keep $PaCO_2$ between 35~45 mmHg. The ventilator settings were changed every 30 min in the following sequence : (1) Baseline, as the basal ventilator setting, (2) Inverse ratio, I:E ratio 2:1, (3) high PEEP, adjust PEEP to achieve the same mean inspiratory pressure (MIP) as in the inverse ratio, (4) High $V_T$, $V_T$ 15 mL/kg, (5) high RR, the same minute ventilation (MV) as in the High $V_T$. Subsequently, the same protocol was repeated after instilling 18 mL/kg of perfluorodecalin for PLV. The parameters of gas exchange, lung mechanics, and hemodynamics were examined. Results: (1) The gas ventilation(GV) group showed no significant changes in the $PaO_2$ at all phases. The $PaCO_2$ was lower and the pH was higher at the high $V_T$ and high RR phases(p<0.05). No significant changes in the lung mechanics and hemodynamics parameters were observed. (2) The baseline $PaO_2$ for the PLV was $312{\pm}$ mmHg. This was significantly lower when decreased compared to the baseline $PaO_2$ for GV which was $504{\pm}81$ mmHg(p=0.001). During PLV, the $PaO_2$, was significantly higher at the high PEEP($452{\pm}38$ mmHg) and high $V_T$ ($461{\pm}53$ mmHg) phases compared with the baseline phase. However, it did not change significantly during the inverse I:E ratio or the high RR phases. (3) The $PaCO_2$ was significantly lower at high $V_T$ and RR phases for both the GV and PLV. During the PLV, $PaCO_2$ were significantly higher compared to the GV (p<0.05). (4) There were no important or significant changes in of baseline and high RR phases lung mechanics and hemodynamics parameters during the PLV. Conclusion: During PLV in the normal lung, adequate $V_T$ and PEEP are important for optimal oxygenation.