• Title/Summary/Keyword: Positive and negative sequence

Search Result 245, Processing Time 0.026 seconds

An Effective Rotor Current Controller for Unbalanced Stand-Alone DFIG Systems in the Rotor Reference Frame

  • Phan, Van-Tung;Lee, Hong-Hee;Chu, Tae-Won
    • Journal of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.724-732
    • /
    • 2010
  • This paper presents an effective rotor current controller for variable-speed stand-alone doubly fed induction generator (DFIG) systems feeding an unbalanced three-phase load. The proposed current controller is developed based on proportional plus two resonant regulators, which are tuned at the positive and negative slip frequencies and implemented in the rotor reference frame without decomposing the positive and negative sequence components of the measured rotor current. In addition, the behavior of the proposed controller is examined in terms of control performance and stability with respect to rotor speed variations, i.e., slip frequency variations. Simulations and experimental results are shown to validate the robustness and effectiveness of the proposed control method.

Intrusion Detection based on Intrusion Prediction DB using System Call Sequences (시스템 호출을 이용한 침입예상 데이터베이스 기반 침입탐지)

  • Ko, Ki-Woong;Shin, Wook;Lee, Dong-Ik
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2002.04b
    • /
    • pp.927-930
    • /
    • 2002
  • 본 논문에서는 중요 프로세스(privileged process)의 시스템 호출 순서(system call sequence)를 이용한 침입탐지 시스템을 제안한다. 기존 연구의 정상행위 기반 침입탐지 시스템은 정상행위를 모델링하여 시스템을 구성하고, 이와 비교를 통해 프로세스의 이상(anomaly) 여부를 결정한다. 이러한 방법은 모델링되지 않은 미지의 행위에 대한 적절한 판단을 행할 수 없으므로, 높은 오류율(false-positive/negative)을 보인다. 본 논문에서는 현재까지 알려진 공격에서 공통적으로 나타나는 윈도우들을 수집하여 침입예상윈도우를 구축하고, 이를 기존의 침입탐지 시스템에 부가적으로 사용하여 효과적으로 오류율(false-positive/negative)을 낮출 수 있음을 보인다. 실험 결과 제안된 방법을 통한 침입탐지는 기존의 방법에 비해 공격 탐지율은 증가하고 정상행위에 대한 오류율은 감소하였다.

  • PDF

The New Finding on BOLD Response of Motor Acupoint KI6(照海) by fMRI (fMRI를 이용하여 수지굴신운동(手指屈伸運動)과 조해(照海)(KI6) 자침(刺鍼)에 의(依)한 대뇌운동피질(大腦運動皮質)의 활성변화(活性變化)에 관(關)한 비교(比較) 연구(硏究))

  • Kwon, Cheol-hyeon;Lee, Jun-beom;Hwang, Min-seob;Yoon, Jong-hwa
    • Journal of Acupuncture Research
    • /
    • v.21 no.6
    • /
    • pp.177-186
    • /
    • 2004
  • Introduction : Recent studies Suggested that there is a strong correlation between acupuncture stimulation and its related cortical activation. Anther study showed that either positive or negative BOLD effects could be observed depending on anatomical structure in acupuncture stimulation. In ttis study, we investigated a new acupoint $KI_6$ (照海), which was known as motor-related acupoint and obtained an evidence that the stimulation of $KI_6$ resulted in either negative or positive BOLD response to stimulation. Methods & Results : 1. Subjects and paradigms : Two separate stimulation paradigms were performed on five healthy (aged 22-23 yrs) in this study. First, the paradigm of acupuncture stimulation was that the acupuncture needle was inserted in acupoints $KI_6$, which is located in lateral side of the foot and then continuously twisted(補瀉를 除外한 捻轉法) for 70 seconds for 10 cycles of activation. During rest period (70 seconds), the needle was completed removed from acupoint. Total 60 cycles were performed and 10 images were obtained per cycle. Second, nonacupoint was randomly selected and the same paradigm was performed as acupoint stimulation. The stimulation protocol comprised 10 cycles of alternating. activation and rest (10 images per cycle). Total 60 cycles were performed and each cycle take about 1.5 sec for motor task. Subjects take an at least 15 minutes break before starting anther paradigm. 2. fMRI mapping : Multi-slice functional images were obtained on a 1.5T Magnetom Vision MRI scanner (Simens Medical, Erlangen, Germany) equipped with high performance whole-body gradients. The BOLD T2 * - weighted images were acquired with acho planar imaging sequence (TR = 1.2 sec, TE = 60 msec, and flip angle = $90_{\circ}$). The other sequence parameter are : FOV = 210 mm, matrix=$64{\times}128$ or $64{\times}64$, slice number=10 and slice thickness = 5 or 8 mm. the anatomic images were obtained with Spin-echo T1-weighted images. The resulting images were then anaiyzed with STIMULATE (CMRR, U. of Minnesota) to generate functional maps using a student T-test (p < 0.005) and cluster analysis. Both positive and negative response were evaluated. Conclusions : We have observed the activation of the motor cortex by stimulating motor-related acupoint ($KI_6$). Among five subjects, negative BOLD response was shown in four and positive response in one. All subjects showed positive response to conventional finger flexion-extension task. To understand the detailed mechanisms of correlation between acupuncture stimulation and BOLD fMRI changes and two typs of response, further study strongly required.

  • PDF

Protection for a Wind Turbine Generator in a Large Wind Farm

  • Zheng, Tai-Ying;Kim, Yeon-Hee;Kang, Yong-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.4
    • /
    • pp.466-473
    • /
    • 2011
  • This paper proposes a protection algorithm for a wind turbine generator (WTG) in a large wind farm. To minimize the outage section, a protection relay for a WTG should operate instantaneously for an internal fault or a connected feeder fault, whereas the relay should not operate for an internal fault of another WTG connected to the same feeder or an adjacent feeder fault. In addition, the relay should operate with a delay for an inter-tie fault or a grid fault. An internal fault of another WTG connected to the same feeder or an adjacent feeder fault, where the relay should not operate, is determined based on the magnitude of the positive sequence current. To differentiate an internal fault or a connected feeder fault from an inter-tie fault or a grid fault, the phase angle of the negative sequence current is used to distinguish a fault type. The magnitude of the positive sequence current is then used to decide either instantaneous operation or delayed operation. The performance of the proposed algorithm is verified under various fault conditions with EMTP-RV generated data. The results indicate that the algorithm can successfully distinguish instantaneous operation, delayed operation, or non-operation depending on fault positions and types.

Comparison of the Real-Time Nucleic Acid Sequence-Based Amplification (NASBA) Assay, Reverse Transcription-PCR (RT-PCR) and Virus Isolation for the Detection of Enterovirus RNA. (엔테로바이러스 검출을 위한 real-time nucleic acid sequence-based amplification (NASBA), reverse transcription-PCR (RT-PCR) 및 바이러스 배양법의 비교)

  • Na, Young-Ran;Joe, Hyeon-Cheol;Lee, Young-Suk;Bin, Jae-Hun;Cheigh, Hong-Sik;Min, Sang-Kee
    • Journal of Life Science
    • /
    • v.18 no.3
    • /
    • pp.374-380
    • /
    • 2008
  • Rapid detection of enterovirus (EVs) is important in the management of aseptic meningitis. We examined the relative efficiency and specificity of the real-time nucleic acid sequence-based amplification (NASBA) comparing with the established reverse transcription polymerase chain reaction (RT-PCR) and viral culture method which were used for the detection of enterovirus RNA in clinical specimens. Of the total 292 samples, 145 were found to be positive to enterovirus RNA by real-time NASBA, 101 were positive by viral culture, and 86 were positive by RT-PCR. 147 samples and 46 samples were determined to be negative and positive by all methods respectively, but 4 samples were positive only by real-time NASBA. To compare the specificity of each method, various clinical samples which were diagnosed for herpes simplex virus (HSV)-1, HSV-2, adenovirus, mumps, and rhinovirus were applied. Except one rhinovirus sample which was false positive to enterovirus RNA by RT-PCR, the other different samples were negative to all three methods. The real-time NASBA procedure can be completed within 5 hours in contrast with 9 hours for the RT-PCR and 3-14 days for the viral culture. From this study, it was suggested that the real-time NASBA assay could be a standardized, rapid, specific, and sensitive procedure for the detection of enterovirus RNA.

Neutral Point Balancing Algorithm for Multi-level Converter under Unbalanced Operating Conditions

  • Jung, Kyungsub;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.177-178
    • /
    • 2015
  • This paper presents a neutral point deviation compensating control algorithm applied to a 3-level NPC converter. The neutral point deviation is analyzed with a focus on the current flowing out of or into the neutral point of the dc link. Based on the zero sequence components of the reference voltages, this paper analyzes the neutral point deviation and balancing control for 3-level NPC converter. An analytical method is proposed to calculate the injected zero sequence voltage for NP balancing based on average neutral current. This paper also proposes a control scheme compensating for the neutral point deviation under generalized unbalanced grid operating conditions. The positive and negative sequence components of the pole voltages and ac input currents are employed to accurately explain the behavior of 3-level NPC converter. Simulation and experimental results for a test set up of 30kW are shown to verify the validity of the proposed algorithm.

  • PDF

Study on Direct Dipolar Effect of Neighboring Protons in Proton Coupled $^{13}C$ Relaxation Experiment

  • NamGung, Hyeon;Lee, Im Pyo;Lee, Jo Ung
    • Bulletin of the Korean Chemical Society
    • /
    • v.21 no.11
    • /
    • pp.1077-1084
    • /
    • 2000
  • The dipolar effect of neighboring protons that are not directly bonded to the carbon of interest on coupled carbon-13 relaxation in a simple organic molecule has been studied by comparing the relaxation behaviors of labeled carbon-13 in $Br13CH_2COOH$ with those in $BrCH_213COOH.$ Various pulse sequences, such as coupled inversion recovery pulse sequence, J-negative and J-positive pulse sequence, and nonselective and selective proton ${\pi}pulse$ sequence, were employed to perform the required coupled spin relaxation experiments. To gain information on various spectral densities, including that of dipolar-CSA cross correlation, the experiments were performed on two different spectrometers, operating, respectively, at 50.31 and 125.51MHz for 13C. The magnitude of CH dipolar spectral densities for $BrCH_213COOH$ was found to be about 8% of those for $Br13CH_2COOH$, which means the effect due to the protons not directly bonded to the carbon of interest is small but not completely negligible.

A New Control Algorithm for Instantaneous Voltage Sag Corrector (순시전압강하 보상기의 새로운 제어 기법)

  • Lee, Sang-Hoon;Choi, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.172-176
    • /
    • 2001
  • In this paper, a new detection algorithm of faulted voltages under the unbalanced condition and a control algorithm of the instantaneous voltage sag corrector (IVSC) are proposed. To quantify the unbalance under fault conditions, the voltages are decomposed into two balanced three-phase systems using the symmetrical components of positive and negative sequence voltages, which is defined by magnitude factor (MF) and unbalance factor (UF). New control algorithm based on MF and UF values for instantaneous voltage compensation are proposed and verified through the PSCAD/EMTDC simulation and experimental results.

  • PDF

ON THE RECURSIVE SEQUENCE X_{n+1} = $\alpha$ - (X_n/X_n-1)

  • YAN XING XUE;LI WAN TONG;ZHAO ZHU
    • Journal of applied mathematics & informatics
    • /
    • v.17 no.1_2_3
    • /
    • pp.269-282
    • /
    • 2005
  • We study the global asymptotic stability, global attractivity, boundedness character, and periodic nature of all positive solutions and all negative solutions of the difference equation $$x_{n+1}\;=\;{\alpha}-{\frac{x_{n-1}}{x_{n}},\;n=0,1,\;{\cdots}$$, where ${\alpha}\;\in\; R$ is a real number, and the initial conditions $x_{-1},\;x_0$ are arbitrary real numbers.

A Syudy On DVR Control for Unbalanced Voltage Compensation (불평형 전압 보상을 위한 DVR 제어에 관한 연구)

  • Jung, Hong-Ju;Chung, Joon-Mo;Song, Jong-Whan
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.218-221
    • /
    • 2001
  • This paper presents a new control scheme for a Dynamic Voltage Restorer(DVR) system consisting of series voltage source PWM converters. The control system is designed using differential controllers and digital filters to transfer the faulted ac source voltage to a d-q model and to separate the positive and negative sequence component for individual compensation. The performance of the presented controller and scheme are confirmed through simulation and actual experiment.

  • PDF