• Title/Summary/Keyword: Positional relationship

Search Result 90, Processing Time 0.025 seconds

A STUDY ON POSITIONAL CHANCE OF THE HYOID BONE BEFORE AND AFTER ACTIVATOR THERAPY IN ANGLE'S CLASS III MALOCCLUSION PATIENTS (Angle씨 III급 부정교합 환자중 Activator사용 전후의 설골의 위치 변화에 관한 연구)

  • Koh, Sang-Duk;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.24 no.4 s.47
    • /
    • pp.827-839
    • /
    • 1994
  • This study was conducted to assess the positional changes of hyoid bone following the use of activator in Angles class III malocclusion patients with functional factors. For this study, 40 Angle's class I patients and 40 Angle's class III patients, totally 80 subjects were used. They are all in Hellman's dental age IIIB-IIIC ranges. In lateral cephalogram to compare Angle's class I group and Angle's class III group, and the positional changes of the hyoid bone before and after the use of activator in Angle's class III malocclusion group. The results were obtained as follows; 1. Comparison of Angle's class I group and Angle's class III group. In comparison to Angle's class I group, hyoid bone is more anteriorly and superiorly positioned in Angle's class III group. The hyoid bone showed reverse inclination to the mandibular plane in Angle's class III malocclusion group. 2. Comparison of the hyoid positional change before and after use of Activator in Angle's class III malocclusion group. The hyoid bone is displaced posteriorly and inferiorly in vertical relationship. The hyoid bone also showed counter-clockwise rotation. 3. No statistical difference was found between after Activator use data of Angle's class m malocclusion group and Angle's class I group. It is concluded that the hyoid bone in Angle's class III malocclusion group changed its position, similar to Angle's class I malocclusion group.

  • PDF

Positional change of the condylar heads after wearing complete denture on dental cone beam CT (치과용 콘빔 CT영상에서 총의치 장착 후 하악과두의 위치변화)

  • Lee, Bong-Ho;Kim, Jae-Duk;Chung, Chae-Heon
    • Imaging Science in Dentistry
    • /
    • v.38 no.1
    • /
    • pp.23-27
    • /
    • 2008
  • Purpose: The aim of this study was to evaluate the change in the position of the mandibular condyle within articular fossa by a CBCT after wearing complete denture (CD). Materials and Methods: CBCT of 34 temporomandibular joints were taken from 9 male and 8 female patients with CB $Mercuray^{TM}$ (Hitachi, Japan) before and after wearing a CD for rehabilitation. Position of mandibular condyle within articular fossa at centric occlusion was evaluated with $Vimplant2.0^{TM}$ (CyberMed, Korea) on the central parasagittal view and curved panoramic coronal view of the condylar head. A statistical evaluation was done with SPSS. Results: The range of anteroposterior positional rate (AP) of condylar head within articular fossa was -16-5 and -10-12 respectively on the right and left sides. Before wearing CD, the AP rate showed discrepancy between right and left sides (p<0.05). After wearing CD, both condyles showed a tendency to decrease in posterior condylar position (right side; p<0.05). The average discrepancy between right and left side in mediolateral positional rate (MD) was 15.5 and 4.5 respectively before and after wearing CD. The improvement was observed in mediolateral relationship of both condylar heads after wearing CD (p< 0.01). Before wearing CD, the average horizontal angle of long axis of condylar head was $79.6{\pm}2.7^{\circ}\;and\;80.1{\pm}5.7^{\circ}$ respectively on the right and left sides. After wearing CD, both condyles were rotated in the same direction in average on axial plane. Conclusion: We observed with CBCT the significant clinical evidence in case of positional change of mandibular condyle after wearing complete denture.

  • PDF

Determination of Target Value under Automatic Vision Inspection Systems (자동시각검사환경하에서 공정 목표치의 설정)

  • 서순근;이성재
    • Journal of Korean Society for Quality Management
    • /
    • v.29 no.3
    • /
    • pp.66-78
    • /
    • 2001
  • This paper deals with problem of determining process target value under automated visual inspection(AVI) system. Three independent error sources - digitizing error, illumination error, and positional error - which have a close relationship with the performance of the AVI system, are considered. Assuming that digitizing error is uniformly or normally distributed and illumination and positional errors are normally distributed, respectively, the distribution function for the error of measured lengths is derived when the length of a product is measured by the AVI system. Then, Optimal target values under two error models of AVI system are obtained by minimizing the total expected cost function which consists of give away, rework and penalty cost. To validate two process setting models, AVI system for drinks filling process is made up and test results are discussed.

  • PDF

Modeling of a 4-axis redundant stage by using SimMechanics (SimMechanics를 이용한 4축 과구동 스테이지의 모델링)

  • Lee, Jin-Young;Park, Won-Jun;Won, Chong-Jin;Jeong, Jay-I.
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.827-831
    • /
    • 2008
  • In this paper, kinematic analysis for a planar 3-DOF redundant stage which has four actuators is presented by using SimMechanics software package. SimMechanics is a block sets of the Matlab/Simulink package. The SimMechanics enables a simplified model for a complex kinematic mechanism, since kinematic relationship between joints and linkages for the kinematic chains are expressed as line vectors and block diagrams. Here, positional error and limit values of movement ranges of the stage are evaluated by using the SimMechanics. The validity of the kinematic characteristics model was compared with theoretical kinematic analyses for the 3-DOF stage.

  • PDF

THE ANALYSIS OF THE POSITIONAL RELATIONSHIP OF CONDYLOID PROCESS WITH MANDIBULAR FOSSA AND MORPHOLOGICAL CLASSIFICATION OF CONDYLAR HEAD IN T.M.J. TROUBLE PATIENTS (악관절 기능장애 환자에 있어서 관절돌기의 위치적 관계 및 그 형태에 관한 방사선학적 연구)

  • Park Chang Sik
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.11 no.1
    • /
    • pp.7-22
    • /
    • 1981
  • A morphological and positional classification was undertaken in the transcranial and transorbital views of 174 traceable films which had been selected from those of 274 patients and previous tracing was performed. For the positional analysis, the author adopted the method which is not influenced by TMJ remodelling, and for the morphological classification, made progress the general method by adding indefinite type to four basic types. The aims of this sutudy consists in performing positional and morphological analysis of condylar head and in its morphological and positional variation in symptomatic patients. I want to express my sincere gratitude to Prof. Park, Tae Won in Seoul National University, interesting me in this field researches and for his never failing interests. I would lide to thank Prof. Ahn, Hyung Kyu and Prof. You, Dong Soo for helpful discussion and critical readings. The author is also indebted to Prof. Fuchihate Hajime in Osaka University, Prof. Uemura, Shusaburo and the late Dr. Nishihara, Heihachi for fruitful discussion and encourgements.

  • PDF

Vertical Dimension during Swallowing and Speech Pattern in Patients with Temporomandibular Disorders (측두하악장애환자에서 연하고경과 발음양상에 관한 연구)

  • Lee, Gyu-Mee;Han, Kyung-Soo;Kwag, Dong-Kon
    • Journal of Oral Medicine and Pain
    • /
    • v.25 no.2
    • /
    • pp.191-203
    • /
    • 2000
  • This study was performed to investigate the relationship between vertical dimension during swallowing and speech pattern in patients with temporomandibular disorders. For this study, 33 patients with temporomandibular disorders(TMDs), namely, 17 patients with disc displacement with reduction and 16 patients with disc displacement without reduction, and 30 normal subjects without any signs and symptoms in the masticatory system were selected as the patient group and as the normal group, respectively. Biopak $system^{(R)}$(Bioresearch Inc., Milwaukee, USA) was used for recording of electromyographic(EMG) activity(${\mu}V$) of the anterior temporalis, the superficial masseter, the sternocleidomastoideus and the trapezius insertion muscle during swallowing, and of mandibular positional change with function time(sec.) during swallowing and speech. A sentence of 'Sue is missing her house' was used for observing of speech pattern. Comparison between the two groups and relationship of the mandibular positional change and the function time between during swallowing and during speech were analysed by SPSS windows program. The results of this study were as follows : 1. Mean EMG activity of the trapezius insertion during swallowing was higher in the patient group, and the value was $3.4{\mu}V$ in patients and $2.1{\mu}V$ in normal subjects. 2. Vertica1 dimension(VD) at mandibular rest position before swallowing was slightly higher in the patient group, but VD at swallowing-late stage and at rest position after swallowing were not different between the two groups. 3. Swallowing time were 2.1 sec. in the patient group, and 1.5 sec. in the normal group, and the difference was significant. 4. VD during speech were generally higher in the normal group. In this case, speaking position showing the most difference between the two groups was 'her' position. The distance from habitual intercuspal position to 'her' position was 4.9mm in the patient group, and 6.6mm in the normal group. Speaking time was also longer in the patient group. 5. There were no difference in all observed items between the two categories of the patient group according to reduction of disc displacement. 6. Relationship between the positional changes during swallowing and speech were different between the patient group and the normal group. And in the normal group, VD at rest position before swallowing was negatively correlated with speaking time.

  • PDF

Mixed-reality simulation for orthognathic surgery

  • Fushima, Kenji;Kobayashi, Masaru
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.13.1-13.12
    • /
    • 2016
  • Background: Mandibular motion tracking system (ManMoS) has been developed for orthognathic surgery. This article aimed to introduce the ManMoS and to examine the accuracy of this system. Methods: Skeletal and dental models are reconstructed in a virtual space from the DICOM data of three-dimensional computed tomography (3D-CT) recording and the STL data of 3D scanning, respectively. The ManMoS uniquely integrates the virtual dento-skeletal model with the real motion of the dental cast mounted on the simulator, using the reference splint. Positional change of the dental cast is tracked by using the 3D motion tracking equipment and reflects on the jaw position of the virtual model in real time, generating the mixed-reality surgical simulation. ManMoS was applied for two clinical cases having a facial asymmetry. In order to assess the accuracy of the ManMoS, the positional change of the lower dental arch was compared between the virtual and real models. Results: With the measurement data of the real lower dental cast as a reference, measurement error for the whole simulation system was less than 0.32 mm. In ManMoS, the skeletal and dental asymmetries were adequately diagnosed in three dimensions. Jaw repositioning was simulated with priority given to the skeletal correction rather than the occlusal correction. In two cases, facial asymmetry was successfully improved while a normal occlusal relationship was reconstructed. Positional change measured in the virtual model did not differ significantly from that in the real model. Conclusions: It was suggested that the accuracy of the ManMoS was good enough for a clinical use. This surgical simulation system appears to meet clinical demands well and is an important facilitator of communication between orthodontists and surgeons.

Three-dimensional cone beam computed tomography analysis of temporomandibular joint response to the Twin-block functional appliance

  • Jiang, Yuan-yuan;Sun, Lian;Wang, Hua;Zhao, Chun-yang;Zhang, Wei-Bing
    • The korean journal of orthodontics
    • /
    • v.50 no.2
    • /
    • pp.86-97
    • /
    • 2020
  • Objective: To propose a three-dimensional (3D) method for evaluating temporomandibular joint (TMJ) changes during Twin-block treatment. Methods: Seventeen patients with Class II division 1 malocclusion treated using Twin-block and nine untreated patients with a similar malocclusion were included in this research. We collected their cone beam computed tomography (CBCT) data from before and 8 months after treatment. Segmentations were constructed using ITK-SNAP. Condylar volume and superficial area were measured using 3D Slicer. The 3D landmarks were identified on CBCT images by using Dolphin software to assess the condylar positional relationship. 3D models of the mandible and glenoid fossa of the patients were constructed and registered via voxel-based superimposition using 3D Slicer. Thereafter, skeletal changes could be visualized using 3DMeshMetric in any direction of the superimposition on a color-coded map. All the superimpositions were measured using the same scale on the distance color-coded map, in which red color represents overgrowth and blue color represents resorption. Results: Significant differences were observed in condylar volume, superficial area, and condylar position in both groups after 8 months. Compared with the control group (CG), the Twin-block group exhibited more obvious condyle-fossa modifications and joint positional changes. Moreover, on the color-coded map, more obvious condyle-fossa modifications could be observed in the posterior and superior directions in the Twin-block group than in the CG. Conclusions: We successfully established a 3D method for measuring and evaluating TMJ changes caused by Twin-block treatment. The treatment produced a larger condylar size and caused condylar positional changes.

A SUFFICIENT CONDITION FOR HYPONORMAL TOEPLITZ OPERATORS ON THE BERGMAN SPACE

  • Sumin Kim;Jongrak Lee
    • Bulletin of the Korean Mathematical Society
    • /
    • v.61 no.4
    • /
    • pp.1019-1031
    • /
    • 2024
  • In this paper we consider the sufficient condition for hyponormal Toeplitz operators T𝛗 with non-harmonic symbols $${\varphi}(z)=\sum_{\ell=1}^{k}{\alpha}_{\ell}z^{{m_{\ell}}{\bar{z}}n_{\ell}}$$ with m-n = δ > 0 for all 1 ≤ ℓ ≤ k, and α ∈ ℂ on the Bergman spaces. In particular, we will observe the characteristics of the hyponormality of the Toeplitz operators T𝛗 according to the positional relationship of the coefficients α's.

Method of Identifying Dynamic Multileaf Collimator Irradiation that is Highly Sensitive to a Systematic MLC Calibration Error

  • Zygmanski, P.;Kung, J.H.
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.74-82
    • /
    • 2002
  • In Intensity Modulated Radiotherapy (IMRT), radiation is delivered in a multiple of Multileaf Collimator (MLC) subfields. A subfield with a small leaf-to-leaf opening is highly sensitive to a leaf-positional error. We introduce a method of identifying and rejecting IMRT plans that are highly sensitive to a systematic MLC gap error (sensitivity to possible random leaf-positional errors is not addressed here). There are two sources of a systematic MLC gap error: Centerline Mechanical Offset (CMO) and, in the case of a rounded end MLC, Radiation Field Offset (RFO). In IMRT planning system, using an incorrect value of RFO introduces a systematic error ΔRFO that results in all leaf-to-leaf gaps that are either too large or too small by (2ㆍΔRFO), whereas assuming that CMO is zero introduces systematic error ΔCMO that results in all gaps that are too large by ΔCMO = CMO. We introduce a concept of the Average Leaf Pair Opening (ALPO) that can be calculated from a dynamic MLC delivery file. We derive an analytic formula for a fractional average fluence error resulting from a systematic gap error of Δ$\chi$ and show that it is inversely proportional to ALPO; explicitly it is equal to, (equation omitted) in which $\varepsilon$ is generally of the order of 1 mm and Δx=2ㆍΔRFO+CMO. This analytic relationship is verified with independent numerical calculations.

  • PDF