• 제목/요약/키워드: Position Resolution

검색결과 763건 처리시간 0.042초

The detection efficiency study of NaI(Tl) scintillation detector with the different numbers of SiPMs

  • Wang, Bao;Zhang, Xiongjie;Wang, Qingshan;Wang, Dongyang;Li, Dong;Xiahou, Mingdong;Zhou, Pengfei;Ye, Hao;Hu, Bin;Zhang, Lijiao
    • Nuclear Engineering and Technology
    • /
    • 제54권7호
    • /
    • pp.2564-2571
    • /
    • 2022
  • SiPMs are generally coupled into whole columns in gamma energy spectrum measurement, but the relationship between the distribution of whole SiPM columns and the energy resolution of the measured energy spectra is rarely reported. In this work, ∅ 3 × 3 inch NaI scintillator is placed on an 8 × 8 SiPM array, and the energy resolution of the 137Cs peak at 662 keV corresponding to the γ-ray is selected as a reference. Each SiPM is switched to explore the influence of the number of SiPM arrays, distribution position, and reflective layer on the energy resolution of SiPMs. Results show that without coupling, the energy resolution is greatly improved when the number of SiPMs ranges from 4 to 32. However, after 32 slices (the area covered by SiPMs relative to the scintillator reaches 25.9%), the improvement in energy resolution and total pulse count is not obvious. In addition, the position of SiPMs relative to the scintillator does not exert much impact on the energy resolution. Results also indicate that by adding a reflective film (ESR), the energy resolution of the tested group increases by 10.38% on average. This work can provide a reference for the design and application of miniaturized SiPM gamma spectrometers.

Performance Evaluation of MTF Peak Detection Methods by a Statistical Analysis for Phone Camera Modules

  • Kwon, Jong-Hoon;Rhee, Hyug-Gyo;Ghim, Young-Sik;Lee, Yun-Woo
    • Journal of the Optical Society of Korea
    • /
    • 제20권1호
    • /
    • pp.150-155
    • /
    • 2016
  • To evaluate the autofocusing performance of recent mobile phone cameras, it is necessary to determine the peak position of the center field MTF (Modulation Transfer Function), -known as the through focus MTF- of the module. However, the MTF peak position found by conventional methods deviates from the ideal position due to the focus scanning resolution of mobile phone cameras. This inaccurate peak position results in false judgements of the optical performance, leading to yield losses or customer complaints. An increase in the focus scanning resolution can address this problem, but the manufacturing UPH (Unit per Hour) level will also unfortunately increase as well, resulting in a loss of manufacturing capabilities. In this paper, several fitting models are studied to find an accurate MTF peak position within a short period of time. With an analysis of a large amount of manufacturing data, it is demonstrated that the fitting methods can reduce false judgements and simultaneously increase the capabilities of the manufacturing system.

PSD의 출력특성향상을 위한 경사 입력광의 특성해석에 대한 기본연구 (Basic Study of the Improvement of PSD Output by Inclined Light Input)

  • 권현규;박창용
    • 한국기계가공학회지
    • /
    • 제9권4호
    • /
    • pp.53-58
    • /
    • 2010
  • In this paper, the output characteristics of PSD(Position Sensetive Detector) used in measurement system are described. Most of the precision measurment systems are accomplished by a laser diode(LD), a photo diode(PD) and PSD(Position Sensetive Detector), which are used in reflection of mirror or projection of infrared spectrometer. But it is especially restricted by resolution of PD and PSD in nano-measurement. A new inclined light methods into the PSD are employed in the surface measurement system for increasing the resolution. As the results, we can know that the output characteristics of detective senser (PSD) become more than 2 or 3 times by changing inclined angle(range: 5 degree) compared with common angle. In addition, the experiment results are confirmed that the change of inclined angle is not affecting to the linearity and repeating.

High Resolution Time Delay Estimation Technique for Position Location

  • Park, Woon-Yong;Lee, Won-Ro;Kong, Seung-Hyun;Lee, Won-Cheol
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -3
    • /
    • pp.1610-1613
    • /
    • 2002
  • This paper analyses the performance of PE-IPDL technique fer the wireless mobile position location, which have been considered as a major candidate for 3GPP position location due to its capability in mitigating the hearability problem and DOP problem. To improve the location performance of PE-IPDL, this paper introduces the high-resolution estimation technique for the first arrival multipath delay, and simulation results verify its superiority. For a systematic analysis of above location method, its performances are exploited by obeying the CODIT channel model specially bad urban channel environment. Simulation results verify its efficiency of enhancing the degree of accuracy in positioning.

  • PDF

정현파 엔코더를 이용한 서보전동기 초정밀 위치 제어에 관한 연구 (A Study on Ultra Precise Position Control of Servomotor using Analog Quadrature Encoder)

  • 김주찬;김장목;김철우;최철;조한익
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.237-239
    • /
    • 2005
  • This paper describes the ultra precise position estimation of a servomotor using sinusoidal encoder based on Arcsine Interpolation Method. The amplitude and offset errors of the sinusoidal encoder output signals are effectively compensated and on-line tuned by utilizing a low cost programmable differential amp without any special expensive equipments. To theoretically evaluate the practical resolution of this system, the relationship between the amplitude of A/D converter input signal errors and the anticipated resolution is briefly dealt with. The performance of the proposed method is verified by the experiments, by comparing it with position and speed control characteristics of the servomotor driving system using a digital incremental 50,000ppr encoder.

  • PDF

Measurement Resolution of Edge Position in Digital Optical Imaging

  • Lee, Sang-Yoon;Kim, Seung-Woo
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제1권1호
    • /
    • pp.49-55
    • /
    • 2000
  • The semiconductor industry relies on digital optical imaging for the overlay metrology of integrated circuit patterns. One critical performance demand in the particular application of digital imaging is placed on the edge resolution that is defined as the smallest detectable displacement of an edge from its image acquired in digital from. As the critical feature size of integrated circuit patterns reaches below 0.35 micrometers, the edge resolution is required to be less than 0.01 micrometers. This requirement is so stringent that fundamental behaviors of digital optical imaging need to be explored especially for the precision coordinate metrology. Our investigation reveals that the edge resolution shows quasi-random characteristics, not being simply deduced from relevant opto-electronic system parameters. Hence, a stochastic upper bound analysis is made to come up with the worst edge resolution that can statistically well predict actual indeterminate edge resolutions obtained with high magnification microscope objectives.

  • PDF

A New Eye Tracking Method as a Smartphone Interface

  • Lee, Eui Chul;Park, Min Woo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제7권4호
    • /
    • pp.834-848
    • /
    • 2013
  • To effectively use these functions many kinds of human-phone interface are used such as touch, voice, and gesture. However, the most important touch interface cannot be used in case of hand disabled person or busy both hands. Although eye tracking is a superb human-computer interface method, it has not been applied to smartphones because of the small screen size, the frequently changing geometric position between the user's face and phone screen, and the low resolution of the frontal cameras. In this paper, a new eye tracking method is proposed to act as a smartphone user interface. To maximize eye image resolution, a zoom lens and three infrared LEDs are adopted. Our proposed method has following novelties. Firstly, appropriate camera specification and image resolution are analyzed in order to smartphone based gaze tracking method. Secondly, facial movement is allowable in case of one eye region is included in image. Thirdly, the proposed method can be operated in case of both landscape and portrait screen modes. Fourthly, only two LED reflective positions are used in order to calculate gaze position on the basis of 2D geometric relation between reflective rectangle and screen. Fifthly, a prototype mock-up design module is made in order to confirm feasibility for applying to actual smart-phone. Experimental results showed that the gaze estimation error was about 31 pixels at a screen resolution of $480{\times}800$ and the average hit ratio of a $5{\times}4$ icon grid was 94.6%.

Target Size Dependence of Spatial Resolution in Heavy Ion CT

  • Ohno, Yumiko;Kohno, Toshiyuki;Kanai, Tatsuaki;Sasaki, Hitomi;Nanbu, Syuya
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.94-96
    • /
    • 2002
  • In order to achieve the radiotherapy more precisely using highly energetic heavy charged particles, it is important to know the distribution of the electron density in a human body, which is highly related to the range of charged particles. We can directly obtain the 2-D distribution of the electron density in a sample from a heavy ion CT image. For this purpose, we have developed a heavy ion CT system using a broad beam. The performance, especially the position resolution, of this system is estimated in this work. All experiments were carried out using the heavy ion beam from the HIMAC. We have obtained the projection data of polyethylene samples with various sizes using He 150 MeV/u, C 290 MeV/u and Ne 400 MeV/u beams. The used targets are the cylinders of 40, 60 and 80 mm in diameter, each of them has a hole of 10 mm in diameter at the center of it. The dependence of the spatial resolution on the target size and the kinds of beams will be discussed.

  • PDF

디지털 엑스선유방촬영장치에서 검출기 위치에 따른 공간분해능의 변화 (Changes in Spatial Resolution at Position of the Detector in Digital Mammography System)

  • 김민혜;천권수
    • 한국방사선학회논문지
    • /
    • 제10권3호
    • /
    • pp.215-222
    • /
    • 2016
  • 엑스선유방촬영술은 다양한 유방질환 중 석회화 병변을 진단하는데 가장 효과적인 방법이다. 환자의 의료피폭 저감과 진단에 필요한 최적의 영상을 얻기 위해서는 성능유지를 지속적으로 관리해야 한다. 엑스선유방촬영술에서 엑스선을 발생시키는 양극의 경사각도는 중심선을 기준으로 하기 때문에 조사야 내의 위치에 따라 엑스선관의 유효초점이 미세하게 달라질 수 있어 공간분해능의 차이가 발생할 수 있다. 본 연구에서는 디지털 엑스선유방촬영장치에서 검출기 위치에 따른 LSF를 측정하여 MTF를 계산함으로써 공간분해능 변화에 대해서 연구하였다. 와이어 직경에 대한 변화에서 $50{\mu}m$ 직경의 와이어의 경우 가장 높은 공간주파수 값을 나타냈으며 검출기의 픽셀보다 작은 직경을 갖는 와이어를 사용해야 검출기의 공간주파수에 따른 응답을 바르게 구할 수 있다는 것을 알 수 있었다. 조사야 내의 검출기의 위치에 따라서 공간주파수는 중심부분의 와이어가 나머지 와이어보다 우수한 MTF 특성을 보였으나, 그 차이는 미소하게 나타났다. 또한 중앙부분에서 반치폭 또는 유효초첨이 가장 작게 나타났으며 중앙에서 벗어날수록 반치폭이 증가하여 공간분해능이 낮아진 것으로 나타났다.

Piezo Actuator를 이용한 초정밀 위치결정기구의 Computer Simulation 및 제어 성능평가 (Computer Simulation and Control performance evaluation of Ultra Precision Positioning Apparatus using Piezo Actuator)

  • 김재열;김영석;곽이구;한재호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.118-122
    • /
    • 2000
  • Recently, High accuracy and precision are required in various industrial field especially, semiconductor manufacturing apparatus, Ultra precision positioning apparatus, Information field and so on. Positioning technology is a very important one among them. For composition of this technology, the development of system with high speed and high resolution is needed. At start point and end position vibration must be repressed on this system for composition of position control. This vibration is arisen nose, is increased setting time, is reduced accuracy. Especially, repressed for the lead with high speed. The small actuator with high speed and high resolution is need to repression against this residual vibration. This actuator is, for example, piezo actuator, piezoelectric material that converting from electronic signal to mechanical force is adequate material, beacause of control of control to position and force. In this study, piezo electric material is used to actuator, ultra precision positioning apparatus with stage of hinge structure is designed, simulation is performed, control performance is tested by producing apparatus. For easy usage and stability in industrial field, we perform to simulation and to position control test by digital PID controller.

  • PDF