• Title/Summary/Keyword: Position Errors

Search Result 1,164, Processing Time 0.029 seconds

Error Analysis for a Cubic Parallel Device Moving at Uniform Velocity (등속 운동을 하는 육면형 병렬기구의 오차 해석)

  • 임승룡;최우천;송재복;홍대희
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.211-214
    • /
    • 2000
  • An error analysis is very important for a precision machine tool to estimate its performance. This study proposes a new parallel device, a cubic parallel manipulator. Errors of the proposed cubic parallel manipulator include universal joint errors, errors occurring due to changes in the fore directions in the links, and actuation errors. An error analysis is performed for the manipulator platform moving at uniform velocity. The analysis shows how the position and orientation of the platform influences the directional link forces that change the errors in the manipulator. The analysis shows that the method can be used in predicting the accuracy of parallel devices.

  • PDF

The role of surgical clips in the evaluation of interfractional uncertainty for treatment of hepatobiliary and pancreatic cancer with postoperative radiotherapy

  • Bae, Jin Suk;Kim, Dong Hyun;Kim, Won Taek;Kim, Yong Ho;Park, Dahl;Ki, Yong Kan
    • Radiation Oncology Journal
    • /
    • v.35 no.1
    • /
    • pp.65-70
    • /
    • 2017
  • Purpose: To evaluate the utility of implanted surgical clips for detecting interfractional errors in the treatment of hepatobiliary and pancreatic cancer with postoperative radiotherapy (PORT). Methods and Materials: Twenty patients had been treated with PORT for locally advanced hepatobiliary or pancreatic cancer, from November 2014 to April 2016. Patients underwent computed tomography simulation and were treated in expiratory breathing phase. During treatment, orthogonal kilovoltage (kV) imaging was taken twice a week, and isocenter shifts were made to match bony anatomy. The difference in position of clips between kV images and digitally reconstructed radiographs was determined. Clips were consist of 3 proximal clips (clip_p, ${\leq}2cm$) and 3 distal clips (clip_d, >2 cm), which were classified according to distance from treatment center. The interfractional displacements of clips were measured in the superior-inferior (SI), anterior-posterior (AP), and right-left (RL) directions. Results: The translocation of clip was well correlated with diaphragm movement in 90.4% (190/210) of all images. The clip position errors greater than 5 mm were observed in 26.0% in SI, 1.8% in AP, and 5.4% in RL directions, respectively. Moreover, the clip position errors greater than 10 mm were observed in 1.9% in SI, 0.2% in AP, and 0.2% in RL directions, despite respiratory control. Conclusion: Quantitative analysis of surgical clip displacement reflect respiratory motion, setup errors and postoperative change of intraabdominal organ position. Furthermore, position of clips is distinguished easily in verification images. The identification of the surgical clip position may lead to a significant improvement in the accuracy of upper abdominal radiation therapy.

A Generalized Analysis of Volumetric Error of a Machine Tool Machining a Sculpture (자유곡면을 가공하는 공작기계 체적오차의 일반화 해석)

  • 고태조
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.4 no.3
    • /
    • pp.39-47
    • /
    • 1995
  • This paper suggests generalize mathematica mode for the benefit of volumetric error analysis of a multi-axis machine tool machining a sculptured surfaces. The volumetric error, in this paper, is defined as a three dimensional error at the cutting point, which is caused by the geometric errors and the kinematic errors of each axis and alignment errors of the cutting tool. The actual cutting position is analyzed based on the form shaping model including a geometric error of the moving carriage, where a form shaping model is derived from the homogeneous transformation matrix. Then the volumetric error is obtained by calculating the position difference between the actual cutting position and the ideal one calculated from a Nonuniform Rational B-Spline named as NURES. The simulation study shows the effectiveness for predicting the behavior of machining error and for the method of error compensation.

  • PDF

Sensorless IPMSM Drives based on Extended Nonlinear State Observer with Parameter Inaccuracy Compensation

  • Mao, Yongle;Liu, Guiying;Chen, Yangsheng
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.3
    • /
    • pp.289-297
    • /
    • 2014
  • This paper proposed a novel high performance sensorless control scheme for IPMSM based on an extended nonlinear state observer. The gain-matrix of the observer has been derived by using state linearization method. Steady state errors in estimated rotor position and speed due to parameter inaccuracy have been analyzed, and an equivalent flux error is defined to represent the overall effect of parameter errors contributing to the wrong convergence of the estimated rotor speed as well as rotor position. Then, an online compensation strategy was proposed to limit the estimation errors in rotor position and speed. The effectiveness of the extended nonlinear state observer is validated through simulation and experimental test.

Correction-Dead Reckoning using Map Matching Information in an Underground Parking Lot

  • Myung Hwan Seo;Jeeseon Kim;Sojin Park;Dongkwon Suh
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.12 no.4
    • /
    • pp.391-398
    • /
    • 2023
  • In this paper, we propose a Correction Dead Reckoning (CDR) solution using correction information such as Map Matching FeedBack (MMFB) in an underground parking lot. In order to correct position errors in an underground parking lot, vehicle position and heading errors are corrected using MMFB information in road link properties. The proposed method was applied to an in-vehicle navigation system and tested. The experimental results show that the proposed robust dead reckoning solution corrects Dead Reckoning (DR) position errors that occur when driving for a long time in an underground parking lot.

Ultra Precise Position Estimation of Servomotor using Analog Quadrature Encoder

  • Kim Ju-Chan;Hwang Seon-Hwan;Kim Jang-Mok;Kim Cheul-U;Choi Cheol
    • Journal of Power Electronics
    • /
    • v.6 no.2
    • /
    • pp.139-145
    • /
    • 2006
  • This paper describes the ultra precise position estimation of a servomotor using a sinusoidal encoder based on Arcsine Interpolation Method for the cost reduction of circuit design. The amplitude and offset errors of the sinusoidal encoder output signals, from the encoder itself and analog signal processing procedures, are effectively compensated and on-line tuned by utilizing a low cost programmable differential amplifier without any special expensive equipment. For a theoretical evaluation of the practical resolution of this system, the relationship between the amplitude of ADC(Analog to Digital Converter) input signal errors and the anticipated resolution is also addressed. The performance of the proposed method is verified by comparing it with speed control characteristics of the servomotor driving system using a digital incremental 50,000ppr encoder in the experiments.

Analysis of Position Error Variance on GNSS Augmentation System due to Non-Common Measurement Error (비공통오차 증가로 인한 위성항법보강시스템 위치 오차 분산 변화 분석)

  • Jun, Hyang-Sig;Ahn, Jong-Sun;Yeom, Chan-Hong;Lee, Young-Jae;Choi, Young-Kiu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.197-200
    • /
    • 2008
  • A GNSS augmentation system provides precise position information using corrected GNSS pseudorange measurements. Common bias errors are corrected by PRC (Pseudorange Correction) between reference stations and a rover. However non-common errors (Ionospheric and Tropospheric noise error) are not corrected. Using position error variance this paper analyzes non-common errors (noise errors) of ionosphere and troposphere wet vapor.

  • PDF

Denasalization error pattern for typically developing and SSD children (일반 및 말소리장애 아동의 탈비음화 오류패턴)

  • Kim, Min Jung
    • Phonetics and Speech Sciences
    • /
    • v.7 no.2
    • /
    • pp.3-8
    • /
    • 2015
  • Denasalization that nasals are replaced by stops is an unusual error pattern related to manner of articulation. The purpose of this study is to investigate the prevalence of denasalization and to scrutinize the nasal production according to phonological context for typically developing children and children with speech sound disorders(SSD). 220 typically developing children and 48 SSD children from 2~6 years of age were tested with a formal word test, and those who demonstrate denasalization were selected. In addition, the nasal production of SSD children with denasalization were analyzed for the correctness and the error types using the formal word test and spontaneous conversation. The results were as follows: (1) Denasalization was shown in below 10% of 2-3 years of age with typically developing children and in above 20% of 2-5 years of age with SSD. (2) The SSD children who demonstrate denasalization were categorized into 4 types according to the error context of nasals; nasal errors with all word positions, nasal errors with word-final and word-medial positions, nasal errors with word-medial position preceding vowels, and nasal errors with word-medial position preceding obstruents. These results indicate that denasalization is a clinically important error pattern, and word-medial position preceding obstruents is an essential context for denasalization in terms of Korean phonotactics.

Classification and Compensation of DC Offset Error and Scale Error in Resolver Signals

  • Lee, Won;Moon, Jong-Joo;Im, Won-Sang;Park, June-Ho;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.1190-1199
    • /
    • 2016
  • This study proposes a classification and compensation algorithm of two non-ideal output signals of a resolver to reduce position errors. Practically, a resolver generates position errors because of amplitude imbalance and quadrature imperfection between the two output signals of the resolver. In this study, a digital signal processor system based on a resolver-to-digital converter is used to reconstruct the two output signals of the resolver. The two output signals, "sin" and "cos," can be represented by a unit circle on the xy-plot. The classification and compensation of the errors can be obtained by using the radius and area of the circle made by the resolver signals. The method computes the integration of the areas made by the two resolver output signals to classify and compensate the error. This system cannot be applied during transient response given that the area integration during the transient state causes an error in the proposed method. The proposed method does not need any additional hardware. The experimental results verify the effectiveness of the proposed algorithm.

Quantification of Acoustic Pressure Estimation Error due to Sensor and Position Mismatch in Planar Acoustic Holography (평면 음향 홀로그래피에서 센서간 특성 차이와 측정 위치의 부정확성에 의한 음압 추정 오차의 정량화)

  • 남경욱;김양한
    • Journal of KSNVE
    • /
    • v.8 no.6
    • /
    • pp.1023-1029
    • /
    • 1998
  • When one attempts to construct a hologram. one finds that there are many sources of measurement errors. These errors are even amplified if one predicts the pressures close to the sources. The pressure estimation errors depend on the following parameters: the measurement spacing on the hologram plane. the prediction spacing on the prediction plane. and the distance between the hologram and the prediction plane. This raper analyzes quantitatively the errors when these are distributed irregularly on the hologram plane The sensor mismatch and inaccurate measurement location. position mismatch. are mainly addressed. In these cases. one can assume that the measurement is a sample of many measurement events. The bias and random error are derived theoretically. Then the relationship between the random error amplification ratio and the parameters mentioned above is examined quantitatively in terms of energy.

  • PDF