• Title/Summary/Keyword: Pose Detection

Search Result 278, Processing Time 0.039 seconds

Environmental Risk Assessment of Polyhexamethyleneguanidine Phosphate by Soil Adsorption/Desorption Coefficient

  • Chang, Hee-Ra;Yang, Kyung-Wook;Kim, Yong-Hwa
    • Korean Journal of Environmental Agriculture
    • /
    • v.25 no.4
    • /
    • pp.365-370
    • /
    • 2006
  • This study was performed to determine the adsorption-desorption characteristics of polyhexame-thyleneguanidine phosphate in three different soil types of textural classification. Adsorption and desorption studies is impotent for prediction their fate and generating essential information on the mobility of chemicals and their distribution in the soil, water and air of our biosphere. The detection limit of the test substance quantified by a spectroscopic method using Eosin indicator was $0.25{\mu}g/mL$. The reproducibility of analytical method was confirmed by the preliminary test. The concentrations of polyhexamethylenequanidine phosphate in aqueous solution were $1.36{\pm}0.09,\;2.45{\pm}0.01,\;and\;$4.25{\pm}0.05{\mu}g/mL$ by a spectroscopic method using Eosin indicator. The adsorption percents of polyhexamethylenequanidine phosphate in soil were greater than 95.2% for all three test soils. The desorption percents from the adsorbed soil were less than 4.5, 4.7 and 4.7%. Therefore, the adsorption coefficient (K) were greater than 110, 111 and 116. The adsorption coefficient calculated as a function of the organic carbon content (Koc) of the test soils were greater than 9,181, 11,100, and 8,942, respectively. Therefore, the test substance, polyhexamethylenequanidine phosphate could be concluded as medium or high adsorption (>25%) and poorly desorption (<75%) in soil media. Therefore, this chemical is likely to be retained in soil media and may not pose a risk in the aquatic environment.

Automatic Person Identification using Multiple Cues

  • Swangpol, Danuwat;Chalidabhongse, Thanarat
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1202-1205
    • /
    • 2005
  • This paper describes a method for vision-based person identification that can detect, track, and recognize person from video using multiple cues: height and dressing colors. The method does not require constrained target's pose or fully frontal face image to identify the person. First, the system, which is connected to a pan-tilt-zoom camera, detects target using motion detection and human cardboard model. The system keeps tracking the moving target while it is trying to identify whether it is a human and identify who it is among the registered persons in the database. To segment the moving target from the background scene, we employ a version of background subtraction technique and some spatial filtering. Once the target is segmented, we then align the target with the generic human cardboard model to verify whether the detected target is a human. If the target is identified as a human, the card board model is also used to segment the body parts to obtain some salient features such as head, torso, and legs. The whole body silhouette is also analyzed to obtain the target's shape information such as height and slimness. We then use these multiple cues (at present, we uses shirt color, trousers color, and body height) to recognize the target using a supervised self-organization process. We preliminary tested the system on a set of 5 subjects with multiple clothes. The recognition rate is 100% if the person is wearing the clothes that were learned before. In case a person wears new dresses the system fail to identify. This means height is not enough to classify persons. We plan to extend the work by adding more cues such as skin color, and face recognition by utilizing the zoom capability of the camera to obtain high resolution view of face; then, evaluate the system with more subjects.

  • PDF

International Comparisons of Management Systems for Medical Waste and Suggestions for Future Direction of Medical Waste Management System in Korea (세계 각국의 의료폐기물 관리 제도 비교: 한국 의료폐기물 관리체계에 대한 시사점)

  • Oh, Se-Eun;Ji, Kyung-hee;Park, Seokhwan;Kim, Pangyi;Lee, Kyoung-Mu
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.6
    • /
    • pp.532-544
    • /
    • 2017
  • Objectives: Because the amount of medical waste (i.e., health-care waste) generated in Korea is rapidly increasing and social concern against its safety is widespread, a number of issues related with medical wastes are being discussed. The purpose of this study is to compare diverse medical waste management systems worldwide and propose future directions of a medical waste management system in Korea. Methods: Literature review was conducted mainly on the WHO, and developed countries such as the European Union (Germany, Belgium and UK), Japan and the United States. For these countries, the data with respect to their systems for medical waste management ranging from the definition of medical waste to the whole processes of collection, transportation and disposal were summarized and compared. Results: The terminology and classification of medical wastes were not consistent for WHO recommendation, EU, Japan, US and Korea. Comparison of the collection, storage, transportation and disposal of medical waste showed that Korea had rather stronger regulations for medical waste management compared to developed countries including Belgium (Flanders region), Germany, Japan and the US. Considering that developed countries adopt rather flexible disposal system especially for general medical wastes which pose lower possibility of infection, Korean government could consider diversifying disposal methods other than incineration. It may also be very important to try to reduce the amount of medical wastes and enough capacity for off-site incineration are secured. Conclusion: Our study of international comparisons suggests that it is necessary to continue to identify advantages and disadvantages of the current medical waste management systems and establish more effective one in Korea.

Bacteriological Hazard Analysis in Minimally Processed Shellfish Products Purchased from Korean Seafood Retail Outlets (유통 중인 패류 단순가공품의 세균학적 위해요소 분석)

  • Kim, Hyun-Jung;Lee, Dong-Soo;Lee, Ji-Min;Kim, Young-Mog;Shin, Il-Shik
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.51 no.2
    • /
    • pp.121-126
    • /
    • 2018
  • The purpose of this study was to assess bacteriological hazards in the following 7 kinds of minimally processed shellfish products purchased from Korean seafood retail outlets: raw oysters stored with seawater in polyethylene bags, frozen oysters, raw mussels, frozen mussels, boiled mussels, raw short-necked clam, and frozen short-necked clams, obtained from Korean seafood retail outlets. The total coliform and Escherichia coli counts determined in all samples were detected below regulation limit of the Korean government guidelines (Food Code). In addition, the high-risk bacterial pathogens, Listeria monocytogenes, Salmonella spp., and E. coli O157:H7 were not detected in any samples. Low-risk pathogens such as Staphylococcus aureus and Vibrio parahaemolyticus were detected at levels above $1.0{\times}10^2$ colony forming unit (CFU)/g in some minimally processed shellfish products. Notably, S. aureus was detected in all samples. Raw oysters stored with seawater in polyethylene bags, frozen oysters, and boiled blue mussels are commonly ingested without heating, and therefore these minimally processed shellfish products pose bacteriological hazards. The detection of S. aureus in all shellfish products, an organism indicative of poor personal hygiene, which can grow and multiply during distribution, indicates the necessity of improving the food safety of minimally processed shellfish products.

Altered Gene Profiles using KISTCHIP-400 in MCF-7 cells after Exposure to Di(2-ethylhexyl) Phthalate (DEHP) and Dibutyl Phthalate (DBP)

  • Yun, Hye-Jung;Kim, Youn-Jung;Kim, Eun-Young;Ryu, Jae-Chun
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2003.10a
    • /
    • pp.174-174
    • /
    • 2003
  • There are many synthetic chemicals, such as di(2-ethylhexyl) phthalate (DEHP) and dibutyl phthalate (DBP), used in chemical reaction processes in industry. The establishment of toxicity and detection of synthetic chemicals that may pose a genetic hazard in our enviornment is subjects of great concern at present DEHP, a ubiquitous phthalate plasticizer, induces a wide range of developmental and reproductive toxicities in mammals. DEHP belongs to the large diverse class of peroxisome proliferator compounds, which include herbicides, hypolipidemic drugs. DBP is a plasticizer used to products containing nitrocellulose, polyvinyl acetate, and polyvinyl chloride such as food wraps and blood bags. DBP is also used in cosmetics as a solvent and fixative for perfumes, a suspension agent for solids, an antifoamer, a skin emollient, and hair spray The present study was performed to examine patterns of gene expression in MCF-7 cells following DEHP and DBP exposure. Changes in gene expression were determined by microarray analysis using KISTCHIP-400 including 401 endocrine related genes based on public database and research papers. Of the genes analysis, we determined that genes detected by array showed a 2-fold or greater change in their expression level(increase or decrease). The results of this study demonstrate that a number of genes were differentially expressed in MCF-7 cells but these changes were not significant. Therefore, we keep going this study using microarray analysis and future studies will examine changes of gene expression on time-course and does treatment in variable cell lines.

  • PDF

Measurement of Fine 6-DOF Displacement using a 3-facet Mirror (삼면반사체를 이용한 6자유도 미소 변위 측정)

  • 박원식;조형석;변용규;박노열
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.50-50
    • /
    • 2000
  • In this paper, a new measuring system is :proposed which can measure the fine 6-DOF displacement of rigid bodies. Its measurement principle is based on detection of laser beam reflected from a specially fabricated mirror that looks like a triangular pyramid having an equilateral cross-sectional shape. The mirror has three lateral reflective surfaces inclined 45$^{\circ}$ to its bottom surface. We call this mirror 3-facet mirror. The 3-facet mirror is mounted on the object whose 6-DOF displacement is to be measured. The measurement is operated by a laser-based optical system composed of a 3-facet mirror, a laser source, three position-sensitive detectors(PSD). In the sensor system, three PSDs are located at three corner points of a triangular formation, which is an equilateral triangular formation tying parallel to the reference plane. The sensitive areas of three PSDs are oriented toward the center point of the triangular formation. The object whose 6-DOF displacement is to be measured is situated at the center with the 3-facet mirror on its top surface. A laser beam is emitted from the laser source located at the upright position and vertically incident on the top of the 3-fatcet mirror. Since each reflective facet faces toward each PSD, the laser beam is reflected at the 3-facet mirror and splits into three sub-beams, each of which is reflected from the three facets and finally arrives at three PSDs, respectively. Since each PSD is a 2-dimensional sensor, we can acquire the information on the 6-DOF displacement of the 3-facet mirror. From this principle, we can get 6-DOF displacement of any object simply by mounting the 3-facet mirror on the object. In this paper, we model the relationship between the 6-DOF displacement of the object and the outputs of three PSDs. And, a series of simulations are performed to demonstrate the effectiveness of the proposed method. The simulation results show that the proposed sensing system can be an effective means of obtaining 3-dimensional position and orientation of arbitrary objects.

  • PDF

Thwarting Sybil Attackers in Reputation-based Scheme in Mobile Ad hoc Networks

  • Abbas, Sohail;Merabti, Madjid;Kifayat, Kashif;Baker, Thar
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.12
    • /
    • pp.6214-6242
    • /
    • 2019
  • Routing in mobile ad hoc networks is performed in a distributed fashion where each node acts as host and router, such that it forwards incoming packets for others without relying on a dedicated router. Nodes are mostly resource constraint and the users are usually inclined to conserve their resources and exhibit selfish behaviour by not contributing in the routing process. The trust and reputation models have been proposed to motivate selfish nodes for cooperation in the packet forwarding process. Nodes having bad trust or reputation are detected and secluded from the network, eventually. However, due to the lack of proper identity management and use of non-persistent identities in ad hoc networks, malicious nodes can pose various threats to these methods. For example, a malicious node can discard the bad reputed identity and enter into the system with another identity afresh, called whitewashing. Similarly, a malicious node may create more than one identity, called Sybil attack, for self-promotion, defame other nodes, and broadcast fake recommendations in the network. These identity-based attacks disrupt the overall detection of the reputation systems. In this paper, we propose a reputation-based scheme that detects selfish nodes and deters identity attacks. We address the issue in such a way that, for normal selfish nodes, it will become no longer advantageous to carry out a whitewash. Sybil attackers are also discouraged (i.e., on a single battery, they may create fewer identities). We design and analyse our rationale via game theory and evaluate our proposed reputation system using NS-2 simulator. The results obtained from the simulation demonstrate that our proposed technique considerably diminishes the throughput and utility of selfish nodes with a single identity and selfish nodes with multiple identities when compared to the benchmark scheme.

Determination of Aflatoxin M1 and Heavy Metals in Infant Formula Milk Brands Available in Pakistani Markets

  • Akhtar, Saeed;Shahzad, Muhammad Arif;Yoo, Sang-Ho;Ismail, Amir;Hameed, Aneela;Ismail, Tariq;Riaz, Muhammad
    • Food Science of Animal Resources
    • /
    • v.37 no.1
    • /
    • pp.79-86
    • /
    • 2017
  • Aflatoxin $M_1$ ($AFM_1$) after its bioconversion from aflatoxin $B_1$ in animal liver becomes the part of milk while heavy metals get entry into milk and milk products during handling in the supply chain. Aflatoxin $M_1$ and heavy metals being toxic compounds are needed to be monitored continuously to avoid any ailments among consumers of foods contaminated with such toxicants. Thirteen commercially available infant formula milk (IFM) brands available in Pakistani markets were analyzed for the quantitative determination of $AFM_1$ and heavy metals through ELISA and atomic absorption spectrophotometer, respectively. $AFM_1$ was found positive in 53.84% samples while 30.76% samples were found exceeding the maximum EU limit i.e. $0.025 {\mu}g/kg$ for $AFM_1$ in IFM. Heavy metals lead (Pb) and cadmium (Cd) were found below the detection limits in any of the sample, whereas the concentrations of iron (Fe), zinc (Zn) and nickel (Ni) ranged between 45.40-97.10, 29.72-113.50 and <$0.001-50.90 {\mu}g/kg$, respectively. The concentration of Fe in all the tested brands was found in normal ranges while the concentrations of Zn and Ni were found exceeding the standard norms. Elevated levels of $AFM_1$, Zn and Ni in some of the tested IFM brands indicated that a diet completely based on these IFM brands might pose sever health implications in the most vulnerable community i.e., infants.

Model-based Body Motion Tracking of a Walking Human (모델 기반의 보행자 신체 추적 기법)

  • Lee, Woo-Ram;Ko, Han-Seok
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.44 no.6
    • /
    • pp.75-83
    • /
    • 2007
  • A model based approach of tracking the limbs of a walking human subject is proposed in this paper. The tracking process begins by building a data base composed of conditional probabilities of motions between the limbs of a walking subject. With a suitable amount of video footage from various human subjects included in the database, a probabilistic model characterizing the relationships between motions of limbs is developed. The motion tracking of a test subject begins with identifying and tracking limbs from the surveillance video image using the edge and silhouette detection methods. When occlusion occurs in any of the limbs being tracked, the approach uses the probabilistic motion model in conjunction with the minimum cost based edge and silhouette tracking model to determine the motion of the limb occluded in the image. The method has shown promising results of tracking occluded limbs in the validation tests.

Risk Assessment for Non-Cancer Effects of Volatile Organic Compounds in Children's Products (어린이용품에 함유된 휘발성유기화합물의 비발암 위해성평가)

  • Kim, Jungkon;Seo, Jung-Kwan;Kim, Taksoo;Park, Gun-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.3
    • /
    • pp.178-186
    • /
    • 2014
  • Background: This study was conducted to assess health risks in regard to exposure by children to volatile organic compounds (VOCs) in children's products. Methods: Ten VOCs were measured by head-space gas chromatography in children's products, including toys, oil pastels, sign pens, furniture, ball pools, and playmats. We estimated the average daily dose (ADD) via inhalation during the use of these children's products and calculated hazard quotient (HQ) by dividing ADD by reference dose of VOCs. Results: Among the measured VOCs, five compounds were identified in children's products: benzene, ethylbenzene, styrene, toluene, and xylene. The detection rates of VOCs in toys, ball pools, furniture, playmats, sign pens, and oil pastels were 85%, 100%, 100%, 30%, 100%, and 60%, respectively. The maximum levels of VOCs were 0.18 mg benzene/kg in toys, 5.92 mg toluene/kg in playmats, 10.37 mg ethylbenzene/kg in ball pools, 24.85 mg xylene/kg in toys, and 118.29 mg styrene/kg in ball pools. From exposure levels of VOCs in the children's products HQs were calculated within a range of $5.71{\times}10^{-10}$ to $4.77{\times}10^{-4}$. The HQ of xylene was the highest for children aged 0-6 playing on the playmats. However, the HQ via inhalation exposure to VOCs in individual products did not exceed 1.00. Conclusion: Based on the results, it was concluded that the use of these children's products do not pose health risks to children.