• Title/Summary/Keyword: Posco e&c

Search Result 151, Processing Time 0.025 seconds

Assessment of Structural Performance for a Lightweight Soundproof Tunnel Composed of Partitioned Pipe Truss Members (격벽화된 파이프 트러스 요소로 구성된 경량방음터널의 구조적 성능 평가)

  • Noh, Myung-Hyun;Ahn, Dong-Wook;Joo, Hyung-Joong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.7 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • In this paper, the full-size structural performance test for a lightweight soundproof tunnel composed of partitioned pipe truss members is carried out to investigate the structural performance. In addition, a nonlinear structural analysis of the same finite element model as the full-size testing model is performed to compare the test result. The test and analysis results showed that the lightweight soundproof tunnel ensures the structural safety against wind loads, snow loads and load combinations. As a result, the full-size test and analysis results meet all the design load conditions, hence the proposed lightweight soundproof tunnel is ready for the field application.

Permeability recovery and changes in fouling layer characteristics of PTFE membrane by enhanced backwash cleaning using NaOCl during coagulation and microfiltration (응집 및 정밀여과공정의 강화역세정시 NaOCl에 따른 PTFE막 투과능 회복과 막오염층 변화)

  • Kang, Sun Gu;Park, Keun Youg;Kwark, Dong-Geun;Kim, Yun-Jung;Kweon, Jihyang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.2
    • /
    • pp.233-241
    • /
    • 2015
  • Polytetrafluoroethylene (PTFE) membrane has high resistance to chlorine, which is a great advantages in chemical cleaning to recover water flux during membrane processes in drinking water systems. A humic kaolin water with approximately 4 mg/L of DOC and 10 NTU of turbidity was prepared as a feed water. Coagulation pretreatment with or without settling was applied. The coagulation with settling showed the greatest water production. The reduced flux was effectively recovered by NaOCl cleaning, i.e., 21% recovery by 50 mg/L of NaOCl cleaning and 49% recovery by 500 mg/L NaOCl cleaning. The images of SEM and AFM analyses were corresponded to the water flux variation. However, when the floc was accumulated on the membrane surfaces, the efficiency of NaOCl cleaning was substantially limited. In addition, dynamic contact angle became greater after cleaning, which indicates changes in characteristics of fouling layer such as surface hydrophobicity. Proper cleaning technologies during enhanced backwash using NaOCl would expand application of PTFE membranes in drinking water systems.

The Corrosion Study of Al Current Collector in Phosphonium Ionic Liquid as Solvent for Lithium Ion Battery

  • Cha, Eun-Hee;Mun, Jun-Young;Cho, E.-Rang;Yim, Tae-Eun;Kim, Young-Gyu;Oh, Seung-M.;Lim, Soo-A;Lim, Jea-Wook
    • Journal of the Korean Electrochemical Society
    • /
    • v.14 no.3
    • /
    • pp.152-156
    • /
    • 2011
  • A room temperature ionic liquid (RTIL) based on trihexyl (tetradecyl)phosphonium bis(trifluoromethanesulfonyl) imide ([$(C_6H_{13})_3P(C_{14}H_{29)}$] [TFSI];P66614TFSI) was synthesized and analyzed to determine their characteristics and properties. The bis(trifluoromethanesulfonyl)imide (TFSI) anion is widely studied as an ionic liquid (IL) forming anion which imparts many useful properties, notably electrochemical stability. Especially its electrochemical and physical characteristics for solvent of lithium ion battery were investigated in detail. $P_{66614}$ TFSI exhibits fairly low conductivity (0.89 mS $cm^{-1}$) and higher viscosity (298 K: 277 cP; 343 K: 39 cP) than other ionic liquids, but it exhibits a high thermal stability (over $400^{\circ}C$). Especially corrosion behavior on Al current collector was tested at room temperature and further it was confirmed that thermal resistivity for Al corrosion was highly increased in 1.0M LiTFSI/$P_{66614}$-TFSI electrolyte comparing with other RTILs by linear sweep thermometry.

Development and Application of CFT without Fire Protection using High Performance Steel and Concrete

  • Hong, Seok-Beom;Kim, Woo-Jae;Park, Hee-Gon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.3
    • /
    • pp.272-281
    • /
    • 2013
  • Concrete filled tube (CFT) columns, which consist of a steel tube filled with concrete, combine the benefits of the two materials. The steel tube provides a confining pressure to the concrete, while the local buckling of steel plate can be prevented by the concrete core. CFT columns also have a high fire resistance due to the heat storage effect of concrete under fire. For this reason, it is possible to develop CFT columns without fire protection measures. CFT columns without fire protection have many advantages, including quality control, cost reduction, better space efficiency and a shorter construction period. Due to these advantages, studies on the development of CFT columns without fire protection measures have been performed. However, CFT columns lose their bearing capacity under fire because the steel tube is exposed to the outside. As a result, the structure is collapsed, causing significant damage. In this research, we made a CFT column using high strength concrete (100 MPa) and high strength steel (800 MPa). We use steel fiber and nylon fiber with concrete to provide fire resistance. We perform the fresh concrete experiment and investigate the fire resistance of the CFT column (${\Box}400{\times}400{\times}15{\times}3000mm$) under loading. To investigate the effect of steel fiber on increasing fire resistance, we compare the fire resistance time according to the steel fiber. Through the test, it was found that the CFT specimen with steel fiber had better fire resistance performance than other cases.

Economic Evaluation of High-Strength Steel for Structural Member Types in Building Structures (부재 종류에 따른 고강도 강재의 경제성 평가)

  • Kim, In Ho;Cho, So Hoon;Kim, Jong Ho;Lee, Chul Woo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.2
    • /
    • pp.113-121
    • /
    • 2013
  • The structural steel produced in domestic is classified into 5 grades. For economic structural design, the structural engineers need to choose optimal steel grades for structural member types, but the related data is not sufficient. Recently, high strength steel with yield strength in 650MPa was developed in domestic. It provides structural engineers with the wider range of structural steel strength, which leads to the larger difference in economic evaluation. In this paper, the economic evaluation of high-strength steel in building structures is investigated, by applying structural steel with 235MPa, 325MPa and 650MPa in yield strength to various types of structural members, and can be used as basic data for economic structural design.

Effectiveness of Wave Resonator for Secondary Undulation under Real Sea Conditions (실해역에서 공진장치를 이용한 부진동의 제어)

  • Jeong, Jin-Woo;Kim, Do-Sam;Park, Jong-Bae;An, Sung-Wook
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.6
    • /
    • pp.51-60
    • /
    • 2010
  • In this study, the performance evaluation of a conventional wave resonator at the entrance of a port or a pier against secondary undulation has been performed using 2D hydrodynamic modeling within port. A wave resonator has been designed for the attenuation of the secondary undulation induced by the long-periodic waves. The controlled performance of the wave resonator has been numerically investigated for CGWAVE MODULE of finite-element model of SMS (Surface water Modeling System) based on the elliptic mild-slope wave equation. SMS was verified though the comparisons with analytical solution performed by Ippen and Goda (1963). Also, It was confirmed that a wave resonator of a rectangular model harbor is effective enough to control the secondary undulation when it compares variation of water level with the case of no resonance system. From the above results, amplification phenomenon induced by long-period waves transferred from 1900 sec to 2100 sec when it applied a wave resonator in Busan Gamcheon Port which is a deep-sea. And it was confirmed that a wave resonator of Pohang New Port attenuates largely long-period waves which are within the range of 300 sec induced by long-period motion of the moored ship.

A Study on the Control of Solitary Waves by Resonator (공진장치에 의한 고립파의 제어에 관한 연구)

  • Lee, Kwang-Ho;Beom, Seong-Sim;Kim, Do-Sam;Park, Jong-Bae;An, Seong-Wook
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.24 no.1
    • /
    • pp.48-57
    • /
    • 2012
  • In this study, 3-dimensional hydraulic model experiment and 3-dimensional numerical analysis were carried out to review the control performance on the solitary waves by attaching the resonator suggested in this study to the openings of the existing rectangular harbors and breakwaters placed in a straight line. In the numerical analysis, TWOPM-3D of 3-D one-field Model for immiscible TWO-Phase flows method using 3-dimensional numerical wave tank was applied, and the validity of the numerical analysis method was verified through comparative analysis between hydraulic experimental results and numerical analysis results. In addition, the effectiveness of the resonator was identified as a result of review on the control performance to control solitary waves of the resonance devices through comparison with cases where the resonators are attached or not.

A Study on the Control of Short-period Waves by Resonator (공진장치에 의한 단주기파랑의 제어에 관한 연구)

  • Lee, Kwang-Ho;Beom, Seong-Sim;Kim, Do-Sam;Park, Jong-Bae;An, Seong-Wook
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.24 no.1
    • /
    • pp.36-47
    • /
    • 2012
  • In this study, the control performance of resonator was reviewed through numerical analysis and 3-dimensional hydraulic model experiments by attaching the resonator suggested in the existing studies to the openings of rectangular harbor and breakwater placed in a straight line to reduce short-period waves. In the numerical analysis, linear analysis method of singularity distribution method based on vertical-line Green function and full non-linear analysis method by 3D-NIT model were applied, and the validity of the numerical analysis methods was verified through comparative analysis between results of hydraulic experiments and numerical analysis results. In addition, effectiveness of the resonator was confirmed by reviewing its control performance on the short-period waves through review on the comparison with the case in which the resonator is not attached.

Dynamic Stability of a Railroad Bridge Using Bi-prestressing Technology (바이프리스트레싱 기법을 이용한 철도교량의 동적안정성)

  • Choi, Sanghyun;Lee, Changsoo;Lim, Jaehoon;Lee, Seungjoon;Yang, Sungdon
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.2
    • /
    • pp.188-194
    • /
    • 2013
  • As the high speed railroad line increases, researches on developing a more economic high speed railroad bridge system have been actively conducted. In this paper, a new type of prestressed concrete girder based on the bi-prestressing technique, which can introduce additional prestress, is presented. The additional prestress can be introduced using a wedge-shaped pin bar into the upper part of the girder section. The applicability of the new girder technique to the high speed railroad bridge is verified via the dynamic stability analysis. Dynamic moving load analyses using the KTX train load are conducted on bridge systems with the span lengths of 30m, 35m, and 40m, respectively. The results of the analysis show that all bridge systems satisfy the limits prescribed in the design specifications to ensure structural stability, driving safety, and ride quality.

Design Optimization of an Ozone Contactor Using Ozone Contactor Model (OCM) Software

  • Kim, Doo-Il;Lee, Chae-Young;Joe, Woo-Hyeun;Lee, Seock-Heon
    • Environmental Engineering Research
    • /
    • v.14 no.4
    • /
    • pp.244-249
    • /
    • 2009
  • Designing an ozone contactor is complicated because the residual ozone, log C. parvum inactivation, and bromate formation should be optimized with fluctuating water quality. OCM software was developed to assist a plant designer or an operator to fulfill the sophisticated optimization required in the design or operation of a new or an existing plant. In this article, numerical simulations were carried out using the OCM software for the design of a new ozone contactor under diverse design factors (i.e., three pHs, three temperatures, low and high dispersion numbers, and four and ten cells with complete mixing) with kinetic parameters obtained from the sand-filter effluent of a water treatment plant treating water from the Paldang impoundment. The results of the simulation suggested that a high residual ozone concentration at low pH and low temperature would be challenging, and PFR-like hydrodynamics could lower the residual ozone concentration. The inactivation of C. parvum oocysts increased at a lower pH. A lower dispersion number and more cell division increased the inactivation efficiency. Bromate was instantaneously formed during the initial ozonation stage. The effluent concentration was much lower than the regulatory levels imposed by the USEPA because of the low bromide level in raw water.