• Title/Summary/Keyword: Portal image

Search Result 148, Processing Time 0.024 seconds

Development of Immobilization Devices for Patients with Pelvic Malignancies and a Feasibility Evaluation during Radiotherapy (골반부 암 환자를 위한 고정기구 개발 및 방사선치료 시 효용성 평가)

  • Park, Jong-Min;Park, Yang-Kyun;Cho, Woong;Park, Charn-Il;Ha, Sung-Whan
    • Radiation Oncology Journal
    • /
    • v.25 no.2
    • /
    • pp.134-144
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: Immobilization devices that improve the setup reproducibility of pelvic cancer patients and that provide comfort to patients during radiotherapy were designed and the feasibility of the devices was evaluated. $\underline{Materials\;and\;Methods}$: A customized device was designed to immobilize a knee, thigh, and foot of a patient. Sixty-one patients with prostate cancer were selected and were divided into two groups-with or without devices. The setup errors were measured with respect to bony landmarks. The difference between digitally reconstructed radiographs (DRR) and simulation films, and the differences between DRR and portal films were measured. $\underline{Results}$: The left-right (LR), anterior-posterior (AP) and craniocaudal (CC) errors between the DRR and simulation films were $1.5{\pm}0.9\;mm$, $3.0{\pm}3.6\;mm$, and $1.6{\pm}0.9\;mm$, respectively without devices. The errors were reduced to $1.3{\pm}1.9\;mm$, $1.8{\pm}1.5\;mm$ and $1.1{\pm}1.1\;mm$, respectively with the devices. The errors between DRR and portal films were $1.6{\pm}1.2\;mm$, $4.0{\pm}4.1\;mm$, and $4.2{\pm}5.5\;mm$, respectively without the devices and were reduced to $1.0{\pm}1.8\;mm$, $1.2{\pm}0.9\;mm$, and $1.2{\pm}0.8\;mm$, respectively, with the devices. The standard deviations among the portal films were 1.1 mm, 2.1 mm, and 1.0 mm at each axis without the devices and 0.9 mm, 1.6 mm and 0.8 mm with the devices. The percentage of setup errors larger than 3 mm and 5 mm were significantly reduced by use of the immobilization devices. $\underline{Conclusion}$: The designed devices improved the setup reproducibility for all three directions and significantly reduced critical setup errors.

The Role of Radiotherapy in the Treatment of Portal Vein Thrombosis from Advanced Hepatocellular Carcinoma (진행된 간세포암에서의 간문맥 혈전증에 대한 방사선치료 효과)

  • Kim, Jung-Hoon;Choi, Eun-Kyung;Ahn, Seung-Do;Lee, Sang-Wook;Shin, Seong-Soo;Choi, Won-Sik;Lim, Young-Suk;Kim, Kang-Mo;Suh, Dong-Jin;Chung, Young-Wha;Lee, Young-Sang;Won, Hyung-Jin;Kim, Jong-Hoon
    • Radiation Oncology Journal
    • /
    • v.25 no.3
    • /
    • pp.170-176
    • /
    • 2007
  • Purpose: To determine the role of radiotherapy for the treatment of portal vein thrombosis (PVT) from hepatocellular carcinoma (HCC). Material and Methods: A retrospective analysis was performed on 70 patients that had been diagnosed with HCC and were treated with three-dimensional conformal radiotherapy (3D-CRT) for the PVT. The radiation dose ranged from 40 Gy to 60 Gy (median dose: 48 Gy) and the biological effective dose (BED) ranged from 31.3 Gy to 78.0 $Gy_{10}$ (median dose: 61.6 $Gy_{10}$). Response was determined by measuring the extent of the PVT on a CT image at 0, 1 and 3 months after completion of the radiotherapy. The median follow-up period was 9 months. Results: The response rate was 47.1% (33 patients), with two patients (2.9%) showing a complete response, 31 patients (44.3%) showing a partial response, and 35 patients (50%) showing stable disease or no response. The 1-year progression-free survival rate was 60%, and the median progression-free survival time was 17 months. The median overall survival time was 11 months, the median survival time in the responders was 15 months and in the nonresponders was 8 months (p=0.032). Four patients (5.7%) had transient liver function impairment during treatment. Radiation induced liver disease (RILD) was observed in only one patient (1.4%). Conclusion: Three-dimensional conformal radiotherapy for the treatment of PVT from advanced HCC was a relatively effective and safe method.

Comparison of Noise Power Spectrum Methodologies in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료시 전자포털영상장치를 이용한 잡음전력스펙트럼 방법론 측정비교)

  • Son, Soon-Yong;Choi, Kwan-Woo;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.99-105
    • /
    • 2016
  • The noise power spectrum (NPS) is one of the most general methods for measuring the noise amplitude and the quality of an image acquired from a uniform radiation field. The purpose of this study was to compare different NPS methodologies by using megavoltage X-ray energies. The NPS evaluation methods in diagnostic radiation were applied to therapy using the International Electro-technical Commission standard (IEC 62220-1). Various radiation therapy (RT) devices such as TrueBeam$^{TM}$(Varian), BEAMVIEW$^{PLUS}$(Siemens), iViewGT(Elekta) and Clinac$^R$ iX (Varian) were used. In order to measure the region of interest (ROI) of the NPS, we used the following four factors: the overlapping impact, the non-overlapping impact, the flatness and penumbra. As for NPS results, iViewGT(Elekta) had the higher amplitude of noise, compared to BEAMVIEW$^{PLUS}$ (Siemens), TrueBeam$^{TM}$(Varian) flattening filter, Clinac$^{R}$iXaS1000(Varian) and TrueBeam$^{TM}$(Varian) flattening filter free. The present study revealed that various factors could be employed to produce megavoltage imaging (MVI) of the NPS and as a baseline standard for NPS methodologies control in MVI.

Precision Analysis of Geotechnical Information for the 3D Integrated Underground Space Map (3차원 지하공간통합지도 구축을 위한 지반정보 정밀도 분석)

  • Lee, Boyoung;Hwang, Bumsik;Cho, Wanjei
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.4
    • /
    • pp.5-12
    • /
    • 2017
  • Since 2000, the national geotechnical information DB has been constructed by Transport and Maritime Affairs (present Ministry of Land) and recently, it provides more than 210 thousands borehole informations through the geotechnical information DB portal systems. The initial project of underground space information computerization was begun in 2007, focusing on collecting the informations after then additional studies had been conducted to verify the precision and accuracy of collected informations in 2013~2014. In accordance with the recent initiation of the 3D integrated underground space mapping project, it is necessary to construct 3D image of the geotechnical information and evaluate the accuracy and precision of the information. Therefore, in this research, the basic information regarding the precision of the geotechnical DB is provided by kriging method and analysis of RMSE for the systematic 3D construction of geotechnical information. In addition, the elevation data errors of boring information are verified by analysis of elevation data such as boring information data and DEM data.

Virtual Non-Contrast Computer Tomography (CT) with Spectral CT as an Alternative to Conventional Unenhanced CT in the Assessment of Gastric Cancer

  • Tian, Shi-Feng;Liu, Ai-Lian;Wang, He-Qing;Liu, Jing-Hong;Sun, Mei-Yu;Liu, Yi-Jun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.6
    • /
    • pp.2521-2526
    • /
    • 2015
  • Objective: The purpose of this study was to evaluate computed tomography (CT) virtual non-contrast (VNC) spectral imaging for gastric carcinoma. Materials and Methods: Fifty-two patients with histologically proven gastric carcinomas underwent gemstone spectral imaging (GSI) including non-contrast and contrast-enhanced hepatic arterial, portal venous, and equilibrium phase acquisitions prior to surgery. VNC arterial phase (VNCa), VNC venous phase (VNCv), and VNC equilibrium phase (VNCe) images were obtained by subtracting iodine from iodine/water images. Images were analyzed with respect to image quality, gastric carcinoma-intragastric water contrast-to-noise ratio (CNR), gastric carcinoma-perigastric fat CNR, serosal invasion, and enlarged lymph nodes around the lesions. Results: Carcinoma-water CNR values were significantly higher in VNCa, VNCv, and VNCe images than in normal CT images (2.72, 2.60, 2.61, respectively, vs 2.35, $p{\leq}0.008$). Carcinoma-perigastric fat CNR values were significantly lower in VNCa, VNCv, and VNCe images than in normal CT images (7.63, 7.49, 7.32, respectively, vs 8.48, p< 0.001). There were no significant differences of carcinoma-water CNR and carcinoma-perigastric fat CNR among VNCa, VNCv, and VNCe images. There was no difference in the determination of invasion or enlarged lymph nodes between normal CT and VNCa images. Conclusions: VNC arterial phase images may be a surrogate for conventional non-contrast CT images in gastric carcinoma evaluation.

Gender-fluid images expressed in the contemporary fashion collections with the theme of feminism (페미니즘 테마 패션 컬렉션에 표현된 젠더 플루이드 이미지)

  • Im, Min-Jung
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.20 no.3
    • /
    • pp.63-78
    • /
    • 2018
  • This study analyzed gender-fluid images as expressions of feminism and gender identity expressed in fashion collections. As for the research method, this study searched the fashion collections, with the theme of feminism, utilizing key words related to feminism on an online portal, and collected the photo materials of fashion collections provided by vogue.com. This study classified the photo materials of 31 fashion collections, with the theme of feminism, into femininity, masculinity, androgyny, and avant-garde, according to the fashion design elements that divide gender identity. As a result of the classification, 326 photos were collected, in which gender identity was expressed ambiguously. This study reclassified the collected photos according to their fashion items and styles. As a result of the study, it was noticed that the fashion collections with the theme of feminism expressed the messages, using lettering graphic images, and performance. In addition, they showed a form in which men's collections and women's collections were integrated according to the change of the perceptions of gender identity, of feminism, and delivered body positive expressions, respecting differences and diversity as individual subjects, by casting diverse models in terms of age, body size, race, and culture. As for the gender identity expressed in the fashion collections, the gender-fluid images were classified into empowerment images, that expresses social rights and dignity; agender images that expresses the possibility of a gender-flexible transition; rational images that expresses the rational and practical characteristics that removed the boundary of fashion; and images of pro-sexism that expresses a new gender identity.

DETERMINANTS OF US CVB'S WEBSITE SERVICE QUALITY (미국 컨벤션뷰로의 웹사이트 서비스 품질결정요인)

  • Kim, Min-Sook;Bang, Ho-Yeol
    • International Commerce and Information Review
    • /
    • v.10 no.4
    • /
    • pp.125-151
    • /
    • 2008
  • Website service quality is widely accepted as one of the key determinants of online business success. Several studies identified key factors that determine the website service quality factors appropriate for online business environments. A convention and visitors bureau (CVB) website is a service portal that delivers information online about a destination so users can develop an overall image of the location. CVBs struggle to deliver positive destination images because the competition among destinations to host conventions is intense. In spite of the important role of CVBs and the beneficial spillover effect of CVBs, there are few studies available reporting on the unique service qualities of a CVB website. The primary purpose of this study was to examine the determining factors that are appropriate for CVB websites from the meeting planners' perspective. The research questions arc: What are the determining factors of service quality of a CVB website? Do the determining factors of CVB website service quality positively influence meeting planners' satisfaction? The new conceptual framework was developed from a variety of destination marketing and Internet marketing concepts: e-servicescape management, web community network, Internet service encounter management, and online system quality. Empirical results indicate that three of the four factors, that is, e-servicescape, web community network, and online system quality are important determinants in evaluating CVB website service quality. The findings also show that three determinants have significant and positive influence on meeting planners' satisfaction. The findings from this study will provide meaningful advice for CVB website quality management. To enhance the CVB website service quality and satisfaction level of meeting planners, these three determinants' should be considered of the utmost strategic importance and priority.

  • PDF

A Comparison of Iopamidol with Iopromide and Iohexol Contrast Media in Hepatic CT Angiography in Beagle Dogs (비글견의 간 CT 혈관조영상에서의 Iopamidol과 Iopromide, Iohexol 조명제의 비교실험)

  • Jeong Yu-Cheol;Lim Chang-Yun;Kim Gyeong-Min;Lee Sung-Ok;Jung Joo-Hyun;Chang Jin-Hwa;Oh Sun-Kyoung;Song Kyoung-Jin;Yoon Jung-Hee;Choi Min-Cheol
    • Journal of Veterinary Clinics
    • /
    • v.23 no.2
    • /
    • pp.129-132
    • /
    • 2006
  • The purpose of this paper was to compare the clinical efficacy of iopamidol and iopromide, iohexol nonionic contrast media in terms of their image quality in Beagle dogs with hepatic CT angiography and their application in veterinary clinics. With 9 Beagle dogs, contrast media of iopamidol (pamiray-$300^(R)$) and iopromide (ultravist-$300^(R)$, iohexol (omnipaque-$300^(R)$) were induced intravenously (600 mg I/kg, BW) and CT angiography was done under general anesthesia. CT scan included scout, pre-contrast and cine examinations. During CT angiography, peak HU (Hounsfield unit) and peak time were examined on each site (ROI; region of interest) of the aorta, caudal vena cava, potral vein and liver parenchyma. Any side effects were also examined. After experiments, it was found that there were no significant changes of HU and maximal enhancing time of each ROIs of aorta, caudal vena cava, portal vein and liver parenchyma between these contrast media. And any side effects were not noted. So it is concluded that iopamidol has similiar contrast enhancement like as iopromide and iohexol in hepatic angiography and and it is thought to be useful for evaluation of the abdominal organs by CT scan in veterinary clinics.

A Conceptual Design of Spatial and Non-spatial Information for Water Hazard Information Management and Service (수재해 정보관리 및 서비스를 위한 공간, 비공간 정보 자료 개념 설계)

  • Lee, Jeong-Ju;Kim, Dong-Young;Jung, Young-Hun;Hwang, Eui-Ho;Chae, Hyo-Sok
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.58 no.2
    • /
    • pp.21-29
    • /
    • 2016
  • This study conducted a basic design of system and interface which provide both of spatial and non-spatial data for water hazard information management. This helps to decide directions of the future integrated water hazard information platform and possible technical examinations of the web-based system for the realization of the prototype. For user friendly system, this study did a survey to investigate the data format, service environment, image processing level and visualization type that users prefer. Also, authorization range was set up by type of the user group. In the water hazard information platform, the data and analysis algorithm were classified by the fields. Furthermore, the platform was consisted with six block systems according to the function and the interface and designed to flexibly mount or modify the additional functions. For a basic design of the data exchange method and protocols, a prototype was constructed by using the spatial information web service technology. The portal service system to visualize and provide spatial data was designed by the WMS/WFS type of OGC standard interface and the FTP/HTTP interface type through open source GIS software for server environment.

Long Distance Vehicle License Plate Region Detection Using Low Resolution Feature of License Plate Region in Road View Images (로드뷰 영상에서 번호판 영역의 저해상도 특징을 이용한 원거리 자동차 번호판 영역 검출)

  • Oh, Myoung-Kwan;Park, Jong-Cheon
    • Journal of Digital Convergence
    • /
    • v.15 no.1
    • /
    • pp.239-245
    • /
    • 2017
  • For privacy protection, we propose a vehicle license plate region detection method in road view image served from portal site. Because vehicle license plate regions in road view images have different feature depending on distance, long distance vehicle license plate regions are not detected by feature of low resolution. Therefore, we suggest a method to detect short distance vehicle license plate regions by edge feature and long distance vehicle license plate regions using MSER feature. And then, we select candidate region of vehicle license plate region from detected region of each method, because the number of the vehicle license plate has a structural feature, we used it to detect the final vehicle license plate region. As the experiment result, we got a recall rate of 93%, precision rate of 75%, and F-Score rate of 80% in various road view images.