• Title/Summary/Keyword: Portable power

Search Result 585, Processing Time 0.021 seconds

Fabrication and Test of Micro Direct Methanol Fuels using Platinum Sputtered Microcolumn Electrodes with a Limited Fuel Source (백금 촉매가 증착된 미소돌기 전극과 유한 연료를 가지는 극소형 직접메탄을 연료전지의 제작 및 성능 평가)

  • 서영호;조영호
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.4
    • /
    • pp.218-224
    • /
    • 2004
  • We present a miniature Direct Methanol Fuel Cell (micro-DMFC) using platinum sputtered microcolumn electrodes with a limited amount of fuel. We use the microcolumn electrode in order to improve the power density of the micro-DMFC that consists of two electrodes and polymer electrolyte. We also design the built-in fuel chamber in the anode for the portable electronics applications. We design and fabricate both microcolumn and planar electrodes, having an identical projective area of 5mm${\times}$5mm. The diffusion current density of the microcolumn electrode is 1.73 times higher than that of the planar electrode at electrode potential of 1.1V in the half-cell test. The micro-DMFC based on the microcolumn electrodes shows the maximum power of 10.8$\pm$7.54㎼(43.23$\pm$0.16㎼/$\textrm{cm}^2$) at the projective area of 5mm${\times}$5mm, while the planar electrode micro-DMFC shows the maximum power of 0.81$\pm$0.42㎼(3.24$\pm$1.68㎼/$\textrm{cm}^2$) at the same projective area. The micro-DMFC based on the microcolumn electrodes shows 13 times higher power density that the micro-DMFC based on the planar electrodes does.

Development of Portable Dissolved Gas Analyzer Using photoacoustic spectroscopy (광음향 분광법을 이용한 휴대용 유중가스분석장치 개발)

  • Kim, Choon-Dong;Kim, Chol-Gyu;Park, Sh-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.10
    • /
    • pp.2431-2438
    • /
    • 2013
  • The paper presents a procedure for how to development and theoretical review on Dissolved Gas Analyzer. the information of abnormal thermal stress on electrical power equipment by testing the gas is validated to easy by the gas analyzer presented in the paper. the analyzed information is used to evaluate the stability of electrical power equipment. the existing and selling DGA(dissolved gas analyzer) is so expensive and vast that all DGA product comes from foreign country. The objective of the paper is to prove that PAS(photoacoustic spectroscopy) based on a compact portable DGA solve the fixed type of DGA in order to eliminate the occurring issue directly or indirectly. the proposed DGA is easy to handle, and this can also analysis in real time for testing electrical power equipment. By applying the proposed portable, DGA be utilized in the currently electrical power equipment that are being implemented to reduce cycle of analysis of dissolved gas, it can contribute to improving safety by providing the agility of the evaluation of degradation.

Development of Portable Cable Fault Detection System with Automatic Fault Distinction and Distance Measurement (자동 고장 판별 및 거리 측정 기능을 갖는 휴대용 케이블 고장 검출 장치 개발)

  • Kim, Jae-Jin;Jeon, Jeong-Chay
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.10
    • /
    • pp.1774-1779
    • /
    • 2016
  • This paper proposes a portable cable fault detection system with automatic fault distinction and distance measurement using time-frequency correlation and reference signal elimination method and automatic fault classification algorithm in order to have more accurate fault determination and location detection than conventional time domain refelectometry (TDR) system despite increased signal attenuation due to the long distance to cable fault location. The performance of the developed system method was validated via an experiment in the test field constructed for the standardized performance test of power cable fault location equipments. The performance evaluation showed that accuracy of the developed system is less than 1.34%. Also, an error of automatic fault type and location by detection of phase and peak value through elimination of the reference signal and normalization of correlation coefficient and automatic fault classification algorithm not occurred.

Implementation of The Mini-type Pico Projector Platform mounting Multimedia (멀티미디어 탑재 초소형 LCOS 피코 프로젝터 플랫폼 구현)

  • Koo, Je-Gil
    • 전자공학회논문지 IE
    • /
    • v.48 no.4
    • /
    • pp.19-24
    • /
    • 2011
  • Advances in mobile communications, portable computing and personal electronics have led consumers to demand large viewing area, bright, high resolution, compact and long life portable displays. Pico projectors are the latest technology to prove that big things often do come in small packages. Our goal in this paper was to implement a portable, low power, and highly adaptable miniature pico projector system. The pico projector is designed many functions of the pico projector solutions, multimedia, and T-DMB broadcasting.

Flash Memory based Indexing Scheme for Embedded Information Devices (내장형 정보기기를 위한 플래시 메모리 기반 색인 기법)

  • Byun, Si-Woo;Roh, Chang-Bae;Huh, Moon-Haeng
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.267-269
    • /
    • 2006
  • Recently, flash memories are one of best media to support portable computer's storages in mobile computing environment. The features of non-volatility, low power consumption, and fast access time for read operations are sufficient grounds to support flash memory as major database storage components of portable computers. However, we need to improve traditional Indexing scheme such as B-Tree due to the relatively slow characteristics of flash operation as compared to RAM memory. In order to achieve this goal, we devise a new indexing scheme called F-Tree. F-Tree improves tree operation performance by compressing pointers and keys in tree nodes and rewriting the nodes without a slow erase operation in node insert/delete processes.

  • PDF

The Analysis of the Operating Characteristics In A 500W Portable Air Cooled Polymer Electrolyte Membrane Fuel Cell (PEMFC) (500W급 공냉식 고분자 연료전지 설계, 제작 및 운전 특성)

  • Son Yeong Jun;Yang Tae Hyeon;Park Gu Gon;Im Seong Dae;Yun Yeong Gi;Lee Won Yong;Kim Chang Su
    • 한국전기화학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.37-42
    • /
    • 2004
  • To maintain proper operating conditions is important to get optimal output power of a PEMFC stack. The air cooled fuel cell stack is widely used in sub kW PEMFC systems. A 500W air cooled PEMFC stack was experimentally investigated to evaluate the design performance and to get optimal operating conditions for the portable application. The relationship between the operating conditions and the performance was analyzed. The results can be used as design criteria for portable PEMFC under various conditions.

  • PDF

Computation of Absorbed Power adiated from a Portable Phone Using FDTD (FDTD 방법을 이용한 휴대폰 전파의 인체 흡수전력량 산출)

  • 김채영;이승학;정백호
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.4
    • /
    • pp.491-498
    • /
    • 1998
  • Based on FDTD(Finite-Difference Time-Domain) method the human head absorbed power radiated from a 1.8 GHz portable phone is computed. For this computation the 7 layered media for the human head modeling and the monopole antenna attached to metallic box for the portable phone are used. To reflect the real circumstances typical sizes of human heads and portable phones are considered in the calculation. The length of monopole antenna is 4.5 cm. Under the predetermined model the distribution of SAR over the human head are calculated, and from which the place of maximum SAR is near the head skin surface, not deep places far into the head. The computation shows the maximum SAR to be 1.4 mWg somewhat less than the internationally adopted value of 1.6 mW/g.

  • PDF

Design of a DC-DC Converter for Portable Device (휴대기기용 DC-DC 부스트 컨버터 집적회로설계)

  • Lee, Ja-kyeong;Song, Han-Jung
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.22 no.2
    • /
    • pp.71-78
    • /
    • 2017
  • In This Paper, A DC-DC Boost Converter for Portable Device has been Proposed. The Converter Which is Operated with 1 MHz High Switching Frequency is Capable of Reducing Mounting Area of Passive Devices Such as Inductor and Capacitor, Consequently is Suitable for Portable Device. This Boost Converter Consists of a Power Stage and a Control Block and a Protect Block. Proposed DC-DC Boost Converter has been Designed a 0.18 um Magnachip CMOS Process Technology, we Examined Performances of the Fabricated Chip and Compared its Measured Results with SPICE Simulation Data. Simulation Results Show that the Output Voltage is 4.8 V in 3.3 V Input Voltage, Output Current 95 mA Which is Larger than 20~50 mA.

Economical Gas Chamber for In-situ Gas Measurement and Analysis of Gas Response Characteristics according to Sensor Voltage (인시투 가스 측정이 가능한 경제적 가스 챔버 구현 및 센서 전압에 따른 가스 응답 특성 분석)

  • Choi, Yun-Suk;Lee, In Hwan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.5
    • /
    • pp.1-8
    • /
    • 2019
  • Breath analysis using a portable device is better than the classical breath analysis system in terms of installation and operation. There is an increasing need to develop cost-effective equipment for testing gas sensors from the viewpoint of functionalities that can be applied applicable to portable devices. In the present study, an economical gas chamber for in-situ gas measurement is implemented with a single gas chamber without using expensive gas storage and control equipment; the gas response characteristics are analyzed using the above-described chamber. The main features of the implemented gas chamber are simple injection procedure, improved gas diffusion, easy measurement and cleaning, support for low-power mode measurement function for portable devices, and open source platform. Moreover, an analysis of gas response characteristics based on changes in sensor voltage show that the sensitivity and 90% response time are affected by the sensor voltage. Furthermore, the sensitivity graph has an inflection point in a specific range. The gas sensor applied in this study showed fast response speed and high sensitivity for sensor voltages of 3.0-3.5 V, regardless of the concentration of acetone gas, the target gas used in this study.

Operating Characteristics on Coupling of Fuel-Cell System with Natural Gas Reformer (휴대전원용 직접알코올 연료전지의 OCV특성 연구)

  • Park, Se-Joon;Choi, Yong-Sung;Lee, Kyung-Sup
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.592-596
    • /
    • 2009
  • DAFC(direct alcohol fuel cell) takes the same structure and operational principle with PEMFC(Proton exchange membrane fuel cell). However, DAFC, which uses liquid alcohol instead of hydrogen as fuel, is able to be used as a portable power for small-scaled electronic devices such as MP3, PMP, and mobile phone because alcohol is quite convenient steady-state compound to carry and store it. This paper presents the OCV(open circuit voltage) characteristics of the cases which are alcohol species and different weight rate of ethanol, respectively. The OCV of methanol fuel cell is slightly higher 0.2V than ethanol one, and 8% wt. rate ethanol is rated as the most appropriate fuel for DAFC.