• 제목/요약/키워드: Portable hydrogen application

검색결과 7건 처리시간 0.027초

휴대용 수소 저장체 성능 특성 연구 (A Performance Study of Portable Hydrogen Storage Tank)

  • 박준호;황용신;지상훈;김성한;차석원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.315-318
    • /
    • 2009
  • Hydrogen is the ideal candidate as an alternative energy carrier, so many hydrogen storage methods are investigated. The hydrogen storage method using metal hydride is good candidate as energy sources for portable devices because hydrogen-storage as metal hydride shows large volumetric storage density. In this study, we investigated the variations of hydrogen charging/discharging performance of metal hydride tanks at different temperature conditions. We charged metal hydride tanks with hydrogen in low temperature because of the exothermic reactions of hydrogen absorption while we discharged in high temperature to provide sufficient heat because of the endothermic reactions of desorption. In addition, we investigated the difference of hydrogen charging/discharging performance between two tanks having different sizes.

  • PDF

Electrochemical Oxidation of Hydrazine in Membraneless Fuel Cells

  • Durga, S.;Ponmani, K.;Kiruthika, S.;Muthukumaran, B.
    • Journal of Electrochemical Science and Technology
    • /
    • 제5권3호
    • /
    • pp.73-81
    • /
    • 2014
  • This paper describes the continuous flow operation of membraneless sodium perborate fuel cell using acid/alkaline bipolar electrolyte. Here, hydrazine is used as a fuel and sodium perborate is used as an oxidant under Alkaline-acid media configuration. Sodium perborate affords hydrogen peroxide in aqueous medium. In our operation, the laminar flow based microfluidic membranleless fuel cell achieved a maximum power density of $27.2mW\;cm^{-2}$ when using alkaline hydrazine as the anolyte and acidic perborate as the catholyte at room temperature with a fuel mixture flow rate of $0.3mL\;min^{-1}$. The simple planar structured membraneless sodium perborate fuel cell enables high design flexibility and easy integration of the microscale fuel cell into actual microfluidic systems and portable power applications.

Influence of the cathode catalyst layer thickness on the behaviour of an air breathing PEM fuel cell

  • Ferreira-Aparicio, Paloma;Chaparro, Antonio M.
    • Advances in Energy Research
    • /
    • 제2권2호
    • /
    • pp.73-84
    • /
    • 2014
  • Fuel cells of proton exchange membrane type (PEMFC) working with hydrogen in the anode and ambient air in the cathode ('air breathing') have been prepared and characterized. The cells have been studied with variable thickness of the cathode catalyst layer ($L_{CL}$), maintaining constant the platinum and ionomer loads. Polarization curves and electrochemical active area measurements have been carried out. The polarization curves are analyzed in terms of a model for a flooded passive air breathing cathode. The analysis shows that $L_{CL}$ affects to electrochemical kinetics and mass transport processes inside the electrode, as reflected by two parameters of the polarization curves: the Tafel slope and the internal resistance. The observed decrease in Tafel slope with decreasing $L_{CL}$ shows improvements in the oxygen reduction kinetics which we attribute to changes in the catalyst layer structure. A decrease in the internal resistance with $L_{CL}$ is attributed to lower protonic resistance of thinner catalyst layers, although the observed decrease is lower than expected probably because the electronic conduction starts to be hindered by more hydrophilic character and thicker ionomer film.

'LTCC를 소재로 하는 마이크로 리포머의 최적 설계에 관한 연구: (다양한 채널구조에 따른 성능변화 고찰)' (A Study on the Optimum Design for LTCC Micro-Reformer: (Performance Evaluation of Various Flow Channel Structures)

  • 정찬화;오정훈
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.551-552
    • /
    • 2006
  • The miniature fuel cells have emerged as a promising power source for applications such as cellular phones, small digital devices, and autonomous sensors to embedded monitors or to micro-electro mechanical system (MEMS) devices. Several chemicals run candidate at a fuel in those systems, such as hydrogen. methanol, ethanol, acetic acid, and di-methyl ether (DME). Among them, hydrogen shows most efficient fuel performance. However, there are some difficulties in practical application for portable power sources. Therefore, more recently, there have been many efforts for development of micro-reformer to operate highly efficient micro fuel cells with liquid fuels such as methanol, ethanol, and DME In our experiments, we have integrated a micro-fuel processor system using low temperature co-fired ceramics (LTCC) materials. Our integrated micro-fuel processor system is containing embedded heaters, cavities, and 3D structures of micro- channels within LTCC layers for embedding catalysts (cf. Figs. 1 and 2). In the micro-channels of LTCC, we have loaded $CuO/ZnO/Al_2O_3$ catalysts using several different coating methods such as powder packing or spraying, dipping, and washing of catalyst slurry.

  • PDF

5kW 급 주택용 고분자 연료전지 시스템 (Development of the 5kW Class Polymer Electrolyte Fuel Cell System for Residential Power Generation)

  • 양태현;박구곤;윤영기;이원용;윤왕래;김창수
    • 한국수소및신에너지학회논문집
    • /
    • 제14권1호
    • /
    • pp.35-45
    • /
    • 2003
  • Polymer electrolyte fuel cells(PEFC) have been considered to be a suitable candidate for residential, portable and mobile applications, due to their high efficiency and power density, even at low operating temperature. KIER developed a 5kW class PEFC system for residential application and operated the system for over 1,000 hours. To develop a 5kW PEFC system, performance of a cell was improved through successive tests of single cell of small and large area. Fabrication of three 2,5 kW class stacks, design and fabrication of natural gas reformer, design of auxiliary equipments such as DC/DC converter, DC/AC inverter and humidifying units were carried out along with integration of components, operation and evaluation of total system. During the development period from 1999 to 2001, MEA(membrane electrode assembly) fabrication technologies, design and fabrication technologies for separators, stacking technologies and so on were developed, thereby providing basis for developing stacks of higher efficiency and power density in the future. Experience of development of natural gas reformer opened possibilities to use various kinds of fuels. Main results obtained from the development of a 5kW class PEFC system for residential application are summarized.

유체소자가 집적화된 면역검사용 휴대용 CMOS 바이오칩의 분석 (ANALYSIS OF FLUIDIC BEAD CUBE EMBEDDED PORTABLE CMOS SENSING SYSTEM FOR IMMUNO REACTION MONITORING)

  • 정용원;박세완;김진석;김현철;전국진
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.755-758
    • /
    • 2005
  • This paper describes the novel immunoassay sensing system for a portable clinical diagnosis system. It consists of a bead cage reactor and a CMOS integrated biosensor. It showed the simple and easy antibody coating method on beads by flow-through avidin biotin complex technology in a microfluidic device. It showed just 90 nL sample consumption and good result for the application of alpha feto protein. The bead cage reactor has the role of the antibody coating, antigen binding and enzyme linking for the electrochemical sensing method. The CMOS biosensor consists of ISFET (ion selective field effect transistor) biosensor and temperature sensor for detecting pH that is the byproduct of enzyme reaction. The sensitivity is 8 $kHz/^{\circ}C$ in a temperature sensor and 33 mV/pH in a pH sensor. After filling the 15 um polystyrene beads in bead cage, antibody flowed and reacted to beads. Subsequently, the biotinylated antigen flowed and bound to the antibody and GOD (glucose oxidase)-avidin conjugate flowed and reacted to the biotin of the biotinylated antigen. After this reaction process, glucose solution flowed and reacted to the GOD on beads. The hydrogen was generated by glucose-GOD reaction. And it was detected by the pH sensor.

  • PDF

화학사고 발생에 따른 주민대피 의사결정 지원을 위한 과학조사장비 활용방안 연구 (A Study on the Use of Scientific Investigation Equipment to Support Decision-making of the Resident Evacuation in the Event of a Chemical Accident)

  • 오주연;이태욱;조국
    • 대한원격탐사학회지
    • /
    • 제38권6_3호
    • /
    • pp.1817-1826
    • /
    • 2022
  • 2012년 구미 불화수소 누출사고 이후 정부는 화학사고의 대응과 수습 등 재난관리를 체계화하고 있다. 특히, 행정안전부는 재난 및 안전관리 기본법을 근거로 화학사고 발생에 따른 주민대피에 대한 명령을 소관하고 있으므로 본 연구에서는 국립재난안전연구원의 화학사고 조사장비를 활용한 화학사고 이후 주민대피 의사결정 지원 및 활용방안을 제시하였다. 화학사고로 인한 과학적 정보수집을 위한 장비 운용체계는 상시와 비상시로 구분하여 원거리 측정장비와 근거리 측정장비의 역할 및 활용목적을 중심으로 제시하였다. 원·근거리 측정장비를 통해 취득된 데이터를 활용하여 비상시에는 화학물질의 검출여부를 모니터링하고, 상시에는 업체별 검출물질에 대한 데이터를 관리함으로써 주민대피 의사결정을 위한 기초자료로 활용할 수 있다. 상시 운용체계에 한하여 장비별로 현장 활용성을 검증하기 위해 화학물질을 측정한 결과, 원거리 측정장비에서는 화학물질의 실시간 검출이 가능함을 확인하였으며, 추후 장비의 측정가능 거리 및 범위에 대한 확인이 필요하다는 점을 확인할 수 있었다. 근거리 측정장비의 경우, 탄화수소 계열의 물질이 주로 검출되며, 온산국가산업단지에 비해 울산·미포국가산업단지에서 높은 수준으로 측정된 것을 확인하였다. 향후 지속적인 데이터 구축을 통해 화학사고 발생에 따른 의사결정 지원을 위한 기초자료로 활용될 수 있을 것으로 기대된다.