• Title/Summary/Keyword: Portable equipment

Search Result 235, Processing Time 0.02 seconds

Exposure Assessment of Dust, Ultra Fine Dust(Particulate Matter 2.5, PM2.5) and Black Carbon among Aircraft Cabin Cleaners (항공기 기내 청소노동자의 분진, 초미세먼지(PM2.5) 및 블랙카본 노출수준 평가)

  • Hyunhee Park;Sedong Kim;Sungho Kim;Seung-Hyun Park
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.2
    • /
    • pp.171-187
    • /
    • 2023
  • Objectives: Aircraft cabin cleaning work is characterized by being performed within a limited time in a narrow and enclosed space. The objective of this study was to evaluate the exposure levels to dust, ultra fine dust(PM2.5) and black carbon(BC) among aircraft cabin cleaners. Methods: Active personal air sampling for respirable dust(n=73) and BC(n=47) was conducted during quick transit cleaning(cabin general and vacuum-specific) and seat cover replacement and total dust and PM2.5 were area-air-sampled as well. Also, size distribution of particle was identified with the cleaning workers targeted. Dusts were collected with PVC filters using gravimetric analysis. The concentration of PM2.5 and the particle size distribution were measured with real-time direct reading portable equipment using light scattering analysis. The concentration of BC was measured by aethalometer(filter-based real-time light absorption analysis instrument). Results: The geometric mean of respirable dust was the highest at vacuum cleaning as 74.4 ㎍/m3, following by replacing seat covers as 49.3 ㎍/m3 and cabin general cleaning as 47.8 ㎍/m3 . The arithmetic mean of PM2.5 was 4.83 ~ 9.89 ㎍/m3 inside the cabin, and 28.5~44.5 ㎍/m3 outside the cabin(from bus and outdoor waiting space). From size distribution, PM2.5/PM10 ratio was 0.54 at quick transit cleaning and 0.41 at replacing seat covers. The average concentration of BC was 2~7 ㎍/m3, showing a high correlation with the PM2.5 concentration. Conclusions: The hazards concentration levels of aircraft cabin cleaners were very similar to those of roadside outdoor workers. As the main source of pollution is estimated to be diesel vehicles operating at airports, and it is necessary to replace older vehicles, strengthen pollutant emission control regulations, and introduce electric vehicles. In addition, it is necessary to provide as part of airport-inftastructure a stable standby waiting space for aircraft cabin cleaners and introduce a systematic safety and health management system for all workers in the aviation industry.

The Effects of Bilateral Chewing Exercise on Occlusion Force and Masseter Muscle Thickness in Community-Dwelling Elderly (양측저작 운동이 지역사회 거주 노인의 교합력과 깨물근에 미치는 효과)

  • Hong, Jun-Yong;Jung, Young-Jin;Kim, Min-Ji;Hwang, Se-Hyun;Park, Ji-Su;Lee, Gi-Hyoun;Kim, Tae-Hoon;Jung, Nam-Hae;Yoon, Tae-Hyung
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.10 no.1
    • /
    • pp.31-38
    • /
    • 2020
  • Objective : The purpose of this study is to investigate the effects of bilateral chewing exercise applied for 6 weeks on occlusion force and masseter muscle thickness in the elderly living in the community. Methods : This study recruited 25 community residents. All participants performed bilateral chewing exercise using equipment developed for the purpose of oral chewing exercise. The chewing exercise was divided into isometric and isotonic type and applied for about 20 minutes a day, five times a week for six weeks. For the evaluation, the masseter muscle thickness and the maximum occlusion force were measured three times at three week intervals using a portable ultrasound instrument and an occlusion force gauge. Results : As a result of the change in masseter muscle thickness, baseline, 3 weeks later, and 6 weeks later referred to 7.51±0.43, 7.63±0.44, and 7.83±0.46, respectively (F=3.819, p<.05). The post hoc test resulted in a significance between baseline and 6 weeks later (p=0.023). Similarly, as a result of the change in occlusion force, baseline, 3 weeks later, and 6 weeks later referred to 265±9.22, 268±9.57, and 271.59±10.16, respectively (F=3.031, p<.05). The post hoc test resulted in a significance between baseline and 6 weeks later (p=0.048). Conclusion : This study confirmed that bilateral chewing exercise was effective for increasing masseter muscle thickness and occlusion force in the elderly. Therefore, bilateral chewing exercise can be applied as a therapeutic exercise method for improving oral function.

Arterial and Venous Blood Gas, Electrolytes, Biochemical and Hematological Values in Healthy Korean Native Calves (건강한 한우 송아지의 동맥과 정맥 혈액의 혈액가스, 전해질, 생화학 및 혈액학적 측정치)

  • Lee, Sung-hwan;Ok, Seung-hoon;Kwon, Hyeok-ho;Kim, Doo
    • Journal of Veterinary Clinics
    • /
    • v.32 no.6
    • /
    • pp.499-503
    • /
    • 2015
  • The objective of this study was to investigate arterial and venous blood gas, electrolytes, biochemical, and hematological values in healthy Korean native calves (KNC). The healthy 62 KNC within 3 weeks-old were examined. The arterial blood was collected from caudal auricular artery and the venous blood from jugular vein. The blood samples were analyzed immediately using a portable blood gas analyzer. The pH, $pO_2$, $pCO_2$, $cHCO_3{^-}$, BE, $cSO_2$, $Na^+$, $Ca^{2+}$, $Cl^-$, anion gap potassium (AgapK), Hct, cHgb, glucose, lactate and creatinine were determined. The normal values for blood gas, electrolytes, biochemical, and hematological variables determined in this study agree with other published values for normal calves. The mean concentration of glucose and lactate within 3 weeks old of KNC is higher than those of adult cattle. The blood values according to weeks of age within 3 weeks-old of arterial and venous blood variables were not significantly different (P > 0.05). Glucose (r = 0.927) had the strongest correlations between arterial and venous values. The correlation between the values of the arterial and the venous blood was strong in creatinine (r = 0.925), lactate (r = 0.815), $Ca^{2+}$ (r = 0.806), Hct (r = 0.799), $Na^+$ (r = 0.790), cHgb (r = 0.786), base excess (r = 0.749), pH (r = 0.710), $HCO_3{^-}$ (r = 0.710), and $cTCO_2$ (0.663). Analysis of blood samples in a field condition, using hand-held analyzer is rapid and useful in bovine practice.

A Study of Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET-CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Kim, Bit-Na;Cho, Suk Won;Lee, Juyoung;Lyu, Kwang Yeul;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.23-30
    • /
    • 2015
  • Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to 99mTc emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radio technologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radio technologists. Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8cm$, mean weight: $65.9{\pm}1.4kg$). Radiation was measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150, and 200 cm, respectively. Then, all the procedure was given with a portable radiation shielding on the location of head, chest, and abdomen at the distance of 100, 150, and 200 cm and transmittance was calculated. In 10 cm, head ($105.40{\mu}Sv/h$) was the highest and foot($15.85{\mu}Sv/h$) was the lowest. In 200 cm, head, chest, and abdomen showed similar. On head, the measured dose rates were $9.56{\mu}Sv/h$, $5.23{\mu}Sv/h$, and $3.40{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.24{\mu}Sv/h$, $1.67{\mu}Sv/h$, and $1.27{\mu}Sv/h$ in 100, 150, and 200 cm on head. On chest, the measured dose rates were $8.54{\mu}Sv/h$, $4.90{\mu}Sv/h$, $3.44{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.27{\mu}Sv/h$, $1.34{\mu}Sv/h$, and $1.13{\mu}Sv/h$ in 100, 150, and 200 cm on chest. On abdomen, the measured dose rates were $9.83{\mu}Sv/h$, $5.15{\mu}Sv/h$, and $3.18{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.60{\mu}Sv/h$, $1.75{\mu}Sv/h$, and $1.23{\mu}Sv/h$ in 100, 150, and 200 cm on abdomen. Transmittance was increased as the distance was expanded. As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the technologists.

A Study to Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET/CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Cho, Seok-Won;Park, Hoon-Hee;Kim, Jung-Yul;Ban, Yung-Kak;Lim, Han-Sang;Oh, Ki-Beak;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.159-165
    • /
    • 2010
  • Purpose: Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to $^{99m}Tc$ emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radiotechnologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radiotechnologists. Materials and Methods: Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8$ cm and mean weight: $65.9{\pm}1.4$ kg). Radiation were measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150 and 200 cm. Then, all the procedure was given with a portable radiation shielding on the location of head, chest and abdomen at the distance of 100, 150 and 200 cm and transmittance was calculated. Results: In 10 cm, head (105.40 ${\mu}Sv/h$) was the highest and foot (15.85 ${\mu}Sv/h$) was the lowest. In 200 cm, head, chest and abdomen showed similar. On head, the measured dose rates were 9.56 ${\mu}Sv/h$, 5.23 ${\mu}Sv/h$, and 3.40 ${\mu}Sv/h$ in 100, 150 and 200 cm respectively. When using shielder, it shows 2.24 ${\mu}Sv/h$, 1.67 ${\mu}Sv/h$, and 1.27 ${\mu}Sv/h$ in 100, 150 and 200 cm on head. On chest, the measured dose rates were 8.54 ${\mu}Sv/h$, 4.90 ${\mu}Sv/h$, 3.44 ${\mu}Sv/h$ in 100, 150 and 200 cm, respectively. When using shielder, it shows 2.27 ${\mu}Sv/h$, 1.34 ${\mu}Sv/h$, and 1.13 ${\mu}Sv/h$ in 100, 150 and 200 cm on chest. On abdomen, the measured dose rates were 9.83 ${\mu}Sv/h$, 5.15 ${\mu}Sv/h$ and 3.18 ${\mu}Sv/h$ in 100, 150 and 200cm respectively. When using shielder, it shows 2.60 ${\mu}Sv/h$, 1.75 ${\mu}Sv/h$ and 1.23 ${\mu}Sv/h$ in 100, 150 and 200 cm on abdomen. Transmittance was increased as the distance was expanded. Conclusion: As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the radiotechnologists.

  • PDF