• Title/Summary/Keyword: Portable Program

Search Result 145, Processing Time 0.031 seconds

A Chi-Square-Based Decision for Real-Time Malware Detection Using PE-File Features

  • Belaoued, Mohamed;Mazouzi, Smaine
    • Journal of Information Processing Systems
    • /
    • v.12 no.4
    • /
    • pp.644-660
    • /
    • 2016
  • The real-time detection of malware remains an open issue, since most of the existing approaches for malware categorization focus on improving the accuracy rather than the detection time. Therefore, finding a proper balance between these two characteristics is very important, especially for such sensitive systems. In this paper, we present a fast portable executable (PE) malware detection system, which is based on the analysis of the set of Application Programming Interfaces (APIs) called by a program and some technical PE features (TPFs). We used an efficient feature selection method, which first selects the most relevant APIs and TPFs using the chi-square ($KHI^2$) measure, and then the Phi (${\varphi}$) coefficient was used to classify the features in different subsets, based on their relevance. We evaluated our method using different classifiers trained on different combinations of feature subsets. We obtained very satisfying results with more than 98% accuracy. Our system is adequate for real-time detection since it is able to categorize a file (Malware or Benign) in 0.09 seconds.

Prototype Development of Design for Toxic Gas Detecting Electrochemical Sensor (유독가스 감지용 전기화학식 센서 디자인 및 시제품 개발)

  • Kim, Jin-Mo;Kim, Tae-Kyu
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.3 no.1
    • /
    • pp.59-62
    • /
    • 2003
  • The death from suffocation due to the gas from various disaster is frequent very and it occurs. Specially only from the company which treats the gas and only the enterprise which maintains the gas the many greeting accident occurs. Also accidents could occur when working around the toxic gas without one's noticing Therefore a development of the portable gas ditectoror is very essential. Specially with development of design and the new product of the electric chemical sensor might help reducing the many accidents. From the side which protects a worker's life, it isn't just simple equipment but also it must be connected directly to life saving is very important. Therefore, the key technical contents of development must be focused on sensor which is simple and easy to carry and able to detect varieties of toxic gas. So, this study is about the product design which is simple and easy to carry and to use.

  • PDF

Dynamic Power Management System Considering Process Status, Battery Characteristics and Application Program Type (프로세스 상태, 배터리 특성, 응용프로그램 종류를 고려한 동적 전력관리 시스템)

  • Kim, Kwang-Jung;Park, Chang-Hyeon
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2007.06b
    • /
    • pp.238-242
    • /
    • 2007
  • 최근들어 휴대용 미디어 플레이어(Portable Media Player)와, 노트북 컴퓨터, PDA(Personal Data Assistant)의 사용이 늘어나면서 얼마나 오랜 시간동안 휴대용 장치를 사용하는가에 대한 문제가 큰 이슈로 떠오르고 있다. 그에 대해 많은 연구가 이루어져 있으며, 현재도 활발히 연구가 진행되고 있다. 본 논문에서는 프로세스 상태, 배터리 상태 그리고 응용프로그램 종류로 이루어진 상황을 고려한 동적 전력관리 시스템에 대해서 제안하고 그에 따른 세부적인 모듈에 관한 설명과 실험 결과를 보여준다. 실험결과 제안한 시스템을 적용하지 않았을 경우와 비교하여 약 14%의 전력 손실 감소 효과를 볼 수 있었다.

  • PDF

Eye Management Program using Detection of Eyes Blink Frequency (눈 깜빡임 수 검출을 이용한 안구 관리 프로그램)

  • Han, Sang-Wook;Won, Ye-Ji;Lee, Hwa-Min
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2019.05a
    • /
    • pp.693-696
    • /
    • 2019
  • IT 기술은 끊임없는 발전을 거듭하고 있으며 현 인류는 기계와 더불어 살고 있다. Desktop, 스마트폰, 노트북 및 태블릿PC는 물론이고, 스마트 워치와 같은 '웨어러블 디바이스(Wearable Device)'의 등장으로 기계 속 세상에 그들과 함께 살고 있다하여도 과언이 아니다. 단연 잦은 기기 사용으로 인해 가장 영향을 크게 받는 인간의 신체 부위는 '눈'이다. 휴대용 기기(Portable Device)는 휴대에 용이해야 한다는 특징 때문에 그 크기가 점차 작아지고 있다. 따라서 작은 기기에 부착된 화면 역시 크기가 감소하였다. 장시간 작은 화면을 집중하여 보게 되면 눈의 피로가 금방 쌓이게 된다. 이로 인해 안구 건조 증 및 시력 저하 발생률이 증가하게 되는데, 영상처리 기술을 이용하여 안구의 깜박임을 감지하고 일정 수치 이하로 깜박임 횟수가 미달될 경우에 안구 운동을 권장하는 프로그램을 개발 하였다.

Development of Obesity Management Application Based on Android -Focused on BMI and Calculate Momentum- (안드로이드 기반 비만 관리 애플리케이션 개발 - BMI 및 운동량 산출을 중심으로 -)

  • Hyun, Dong-Lim;Song, Kyung-Chul;Kim, Eun-Gil;Kim, Jong-Hoon
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.23 no.4
    • /
    • pp.568-581
    • /
    • 2011
  • This thesis is the study about application development for management obesity and personal health matters systematically based on Android smart phone system. Growing obesity problem for students organized by the lack of a device or program to manage at home has been favored as a serious problem. Currently developed smart phones has come into wide use by portable features and many applications. And to support populations of these features smart phones will be available for obesity management in your home without any equipment using. Accordingly, this paper is the study about application development for management obesity for growing students at home based on the latest smart phone platform Android.

Literature Review on Cosmic Radiation Exposure to Air Craft Cabin Crew (항공기 객실승무원의 우주방사선 노출에 관한 고찰)

  • Jang, Ryeo-Jin
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.643-649
    • /
    • 2018
  • Recently, together with advancement of domestic aviation industry, overseas tourists using planes have been soared. This study aimed to investigate the risk of diseases for the passengers and flight attendants from the exposed cosmic radiation during the flight by domestic and international literature reviews, as follows. Airliners should develop the program to measure the actual radiation dose and prepare the portable devices for radiation measurement in flight to lower the accumulated dose of cosmic radiation by the attendants. Regulation should be prepared to check the exposed dose during the flight for the passengers by announcement of individual exposed radiation dose which has been provided only to the flight attendants. Passengers and flight attendants should recognize they are exposed to excessive cosmic radiation during the flight and civilians should be protected by the cosmic radiation when they use the flights, which should be prepared by the regulations.

An Analysis of Factors That Affect Image Quality Deterioration in The Potable X-ray Examination on using Digital Wireless Detector (디지털 무선 검출기를 이용한 이동형 X선검사에서 영상품질 저하의 요인분석)

  • Yu, Young-Eun;Lim, Cheong-Hwan;Ko, Joo-Young
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.93-100
    • /
    • 2014
  • Recently the development of portable digital wireless imaging system, which acquires digital radiation images by using wireless LAN telecommunications function in an easy and fast way, provides lots of convenience for people. Considering the characteristics of portable imaging tests on emergency and critical patients, this study aims to suggest guidelines for Digital wireless detector by evaluating the effect of de-centering of focus-grid and displacement of subject in detector on the quality of image. The equipments used for this study were Elmo-T6 Digital Mobile X-ray system (SIMAZU Corp.), el' Tor ($14{\times}17$ "Wireless detector), Grid (10:1) and Chest & head phantom. After acquiring post-processing image according to dose increase and de-centering image of grid-focus and head phantom displacement image, this study compared, analyzed and evaluated these images by using a digital image analysis program by Image J. In the change of images based on dose increase, images were rough in the dose of 0.5 mAs, while there was no difference among images in the proper dose of 1~2 mAs and, especially from 2.5 mAs, average value of pixels radically decreased, affecting contrast. Over 3 mAs, contrast dropped due to saturation phenomenon of lungs. As the result of analysis using Image J program, with the increase of displacement between focus-grid and head phantom, the frequency of low pixel value also increase, causing the outline of surface image to disappear, which in turn affects contrast. For better quality imaging, a radiographer must be aware before the time of test that the image quality can be changed based on the critical patient's posture, movement, respiration, displacement of X-ray tube and distance of imaging.

Fabrication and Characterization of Portable Electronic Nose System for Identification of CO/HC Gases (CO/HC 가스 인식을 위한 소형 전자코 시스템의 제작 및 특성)

  • Hong, Hyung-Ki;Kwon, Chul-Han;Yun, Dong-Hyun;Kim, Seung-Ryeol;Lee, Kyu-Chung;Kim, In-Soo;Sung, Yung-Kwon
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.6
    • /
    • pp.476-482
    • /
    • 1997
  • A portable electronic nose system has been fabricated and characterized using an oxide semiconductor gas sensor array and pattern recognition techniques such as principal component analysis and back-propagation artificial neural network. The sensor array consists of six thick-film gas sensors whose sensing layers are Pd-doped $WO_{3}$, Pt-doped $SnO_{2}$, $TiO_{2}-Sb_{2}O_{5}-Pd$-doped $SnO_{2}$, $TiO_{2}-Sb_{2}O_{5}-Pd$-doped $SnO_{2}$ + Pd coated layer, $Al_{2}O_{3}$-doped ZnO and $PdCl_{2}$-doped $SnO_{2}$. The portable electronic nose system consists of an 16bit Intel 80c196kc as CPU, an EPROM for storing system main program, an EEPROM for containing optimized connection weights of artificial neural network, an LCD for displaying gas concentrations. As an application the system has been used to identify 26 carbon monoxide/hydrocarbon (CO/HC) car exhausting gases in the concentration range of CO 0%/HC 0 ppm to CO 7.6%/HC 400 ppm and the identification has been successfully demonstrated.

  • PDF

Development and Assesment of an Embedded Portable A-ABR System (임베디드 기반의 휴대용 A-ABR 시스템 개발 및 평가)

  • Noh, Hyung-Wook;Nam, Ki-Chang;Jang, Kyung-Hwan;Cha, Eun-Jong;Kim, Deok-Won
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.3
    • /
    • pp.48-55
    • /
    • 2010
  • Hearing impairment is one of the most common birth defects among infants. Significant bilateral hearing impairment have profound effects on speech and language development. But it can be prevented, if a hearing impairment is identified and treated in its early stage. ABR (auditory brainstem response) is useful screening tool for new born hearing test. However, the interpretation of conventional ABR should be done by a experienced audiologist and testing takes some time. Therefore, A-ABR(automated ABR) which detect ABR peak automatically have been developed recently. In contrast to A-ABR researches became active in overseas, there has been little study in Korea. In this study, we have developed a portable A-ABR system based on the results of our previous study. For the evaluation of the developed system, the clinical trials were performed on adults and infants. As a results, it showed good sensitivity (94.4%) and specificity (92.2%), and accuracy (93.0%) between clinical diagnosis and the developed A-ABR test.

Development and Utility Evaluation of Portable Respiration Training Device for Image-guided Stereotactic Body Radiation Therapy (SBRT) (영상유도 체부정위방사선 치료시 호흡동조를 위한 휴대형 호흡연습장치의 개발 및 유용성 평가)

  • Hwang, Seon Bung;Park, Mun Kyu;Park, Seung Woo;Cho, Yu Ra;Lee, Dong Han;Jung, Hai Jo;Ji, Young Hoon;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.264-270
    • /
    • 2014
  • This study developed a portable respiratory training device to improve breathing stability, which is an important element in using the CyberKnife Synchrony respiratory tracking device, one of the typical Stereotactic Radiation Therapy (SRT) devices. It produced an interface for users to be able to select one of two displays, a graph type and a bar type, supported an auditory system that helps them expect next respiration by improving a sense of rhythm of their respiratory period, and provided comfortable respiratory inducement. By targeting 5 applicants and applying individual respiratory period detected through a self-developed program, it acquired signal data of 'guide respiration' that induces breathing through signal data gained from 'free respiration' and an auditory system, and evaluated the usability by comparing deviation average values of respiratory period and respiratory amplitude. It could be identified that respiratory period decreased $55.74{\pm}0.14%$ compared to free respiration, and respiratory amplitude decreased $28.12{\pm}0.10%$ compared to free respiration, which confirmed the consistency and stability of respiratory. SBRT, developed based on these results, using the portable respiratory training device, for liver cancer or lung cancer, is evaluated to be able to help reduce delayed treatment time due to respiratory instability and improve treatment accuracy, and if it could be applied to developing respiratory training applications targeting an android-based portable device in the future, even use convenience and economic efficiency are expected.