• Title/Summary/Keyword: Portable Program

Search Result 145, Processing Time 0.027 seconds

Development of a Portable Vibration Analyzer for Precision Diagnosis of Plant's Rotating Equipment (발전소 회전기기 정밀진단을 위한 휴대용 진동분석기 개발)

  • Noh, Hyungho;Y, Hoseon
    • Plant Journal
    • /
    • v.17 no.4
    • /
    • pp.53-60
    • /
    • 2021
  • The purpose of this study was to develop a portable vibration analyzer that is effective for acquiring and analyzing vibration data of rotating equipment of a power plant and a domestic vibration monitoring system manufacturer Nada Co., Ltd. The hardware of the developed portable vibration analyzer minimizes measurement errors by calibrating the measured values obtained through measurement uncertainty for calibration of the measuring devices in the system, and is composed of a signal processing device with high resolution through high speed data processing. The software structure implements a variety of vibration plots to execute a detailed analysis program, and applies algorithms to measure and remove noise caused by disturbances while operating a rotating machine. The developed product contributed greatly to increase the user's mobility and performance, as well as to reduce the purchase cost due to localization.

A Visual Concurrent Programming Based on Extended State Transition Graph (확장 상태 전이 그래프에 기반을 둔 시각 병렬 프로그래밍)

  • Chung, Won-Ho;Hur, Hye-Jung
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.8
    • /
    • pp.2430-2441
    • /
    • 2000
  • A visual concurrent programming environment, called ESTGVP is designed and implemented, which is easy to understand, highly portable, and can represent parallel behaviors. For our purpose, a conventional state transition graph is extended so as to enable both of synchronous and asynchronous parallel operations. We call it extended state transition graph (ESTG). ESTGVP uses the ESTG and texts for programming, and makes it easy programming sequential and parallel behaviors. Also, it is easy to understand the control structure of a program because ESTGVP is a visual programming environment based on the graph. ESTGVP is written in Tel language and thus it is highly portable on various operating systems. It consists of three major components; edition, transformation and execution. If necessary, ESTG can be transformed into C or Tel language, and its execution is based on Tel.

  • PDF

Machining Technology of pinnacle Cutter Edge for Flexible Sheet Die (필름시트 절단용 다이의 절인 가공 기초연구)

  • Je T.J.;Choi D.S.;Whang K.H.;Lee E.S.;Hong S.M.;Choi J.S.;Song B.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.19-20
    • /
    • 2006
  • As the Mobile and Display technology are being developed quickly, new wireless devices are released in great numbers. They reduce existing devices' life time and demand a reduction of developing period of portable devices. With these demands, existing film cutting mold used many films of portable devices, especially LCD Display, needs to be more precise, and cheaper. In this research, we have analyzed machining characteristics of cutter shapes, materials, and cutting conditions for application to other films. Cutter edge was machined by slot cutting method and CAD program to select the cutter shape and cutter angle. Also, we have determined the optimal cutting conditions using high speed machining experiments to improve the productivity.

  • PDF

Development of Controlling and Analyzing Software for Portable Atomic Emission Spectrometry (휴대용 원자 방출 분광계를 위한 제어 및 분석용 소프트웨어 개발)

  • Lee, Sang Chun;Lee, Chang-Soo;Jung, Min-Soo;Ryu, Dong-Hang
    • Analytical Science and Technology
    • /
    • v.11 no.1
    • /
    • pp.1-7
    • /
    • 1998
  • This study focuses on developing a controlling and analyzing software for the portable atomic emission spectrometer equipped with an electrothermal vaporizer(ETV) that can perform the in-situ trace analysis of heavy metal ions dissolved in water. The software works well for a notebook PC and it is exclusively developed for the real time analysis with a line filter and a photomultiplier light detector. The program is designed to operate under Windows 95 environment and either Korean or English can be used as a main language. The Delphi 2.0 language software is mainly used for programing. The program is designed to make a calibration curve and the system users can get the analytical data in a short time. And a final report can be generated without having difficulties. This software can be easily modified for other analytical atomic spectrometers.

  • PDF

Development of Portable Colorimeter and Size Analyzer by Using Smartphone (스마트폰을 이용한 휴대용 색차계와 입도계 개발)

  • Yoo, Sanggyu;Park, Hyunmin;Kim, Hyungu;Kim, Sayeom;Song, Simon
    • Journal of the Korean Society of Visualization
    • /
    • v.17 no.3
    • /
    • pp.19-23
    • /
    • 2019
  • The purpose of this research is to develop a facile measurement system for colorimetric analysis for zinc powder and size analyzer for zeolite particles in order to reduce the process time for their characteristic analysis. We present facile smartphone-based analysis methods to measure and estimate the size of zinc power by using colorimeteric method and the size of zeolite particles by using ImageJ program which is an open-source program. The results show a possibility of our methods to replace the previous professional analysis processes with them.

In-transit development of color abnormalities in turkey breast meat during winter season

  • Carvalho, Rafael H.;Honorato, Danielle C.B.;Guarnieri, Paulo D.;Soares, Adriana L.;Pedrao, Mayka R.;Oba, Alexandre;Paiao, Fernanda G.;Ida, Elza I.;Shimokomaki, Massami
    • Journal of Animal Science and Technology
    • /
    • v.60 no.1
    • /
    • pp.30.1-30.10
    • /
    • 2018
  • Background: The poultry industry suffers losses from problems as pale, soft and exudative (PSE), and dark, firm and dry (DFD) meat can develop in meat as a result of short- and long-term stress, respectively. These abnormalities are impacted by pre-slaughter animal welfare. Methods: This work evaluated the effects of open vehicle container microclimate, throughout the $38{\pm}10km$ journey from the farm to the slaughterhouse, on commercially turkey transported during the Brazilian winter season. The journey was initiated immediately after water bath in truck fitted with portable Kestrel anemometers to measure air ventilation, relative humidity, temperature and ventilation. Results: The inferior compartments of the middle and rear truck regions showed highest temperature and relative humidity, and lower air ventilation. In addition, the superior compartments of the front truck regions presented lower temperature and wind chill, and highest air ventilation. The breast meat samples from animals located at the inferior compartments of the middle and rear truck regions and subjected to with water bath (WiB) treatment presented highest DFD-like and had lowest PSE-like meat incidence than those from animals located at other compartments within the container. Lower incidence of PSE-like meat was observed in birds without water bath (WoB). Conclusions: Assessment on turkeys transported under Brazilian southern winter conditions revealed that breast meat quality can be affected by relative humidity, air ventilation, temperature, and transport under subtropical conditions promoting color abnormalities and the formation of simultaneously PSE-like and DFD-like meat.

Effects of a Portable Computerized Cognitive Training System on the Visual-perceptual Function of Stroke Patients with Mild Cognitive Impairment : A Pilot Study (휴대용 전산화 인지훈련 시스템이 경도인지손상이 있는 뇌졸중 환자의 시지각에 미치는 효과)

  • Jeon, Min-Jae;Moon, Jong-Hoon
    • Journal of Korea Entertainment Industry Association
    • /
    • v.13 no.8
    • /
    • pp.603-610
    • /
    • 2019
  • This pilot study investigated the effects of a portable computerized cognitive training system on the visual-perceptual function of stroke patients with mild cognitive impairment. Subjects were twelve stroke patients with mild cognitive impairment, who were assigned to an experimental group (n=6) or a control group (n=6). All subjects were trained in their respective groups for 30 min/day, five times a week, for four weeks. In each session, the experimental group received a portable computerized cognitive training program, and the control group received conventional cognitive training. The Motor-Free Visual Perception-3 (MVPT-3) was used to measure subjects' visual-perceptual ability. The MVPT-3 total scores for both groups significantly improved after the intervention (p<.05). The total score on the MVPT-3 and the score on the visual short-term memory subcategory of the MVPT-3 significantly improved for the experimental group compared to the control group (p<.05). These findings suggest that the portable computerized cognitive training system might be effective to improve the visual-perceptual function of stroke patients with mild cognitive impairment.

Optimization of In-vivo Monitoring Program for Radiation Emergency Response

  • Ha, Wi-Ho;Kim, Jong Kyung
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.333-338
    • /
    • 2016
  • Background: In case of radiation emergencies, internal exposure monitoring for the members of public will be required to confirm internal contamination of each individual. In-vivo monitoring technique using portable gamma spectrometer can be easily applied for internal exposure monitoring in the vicinity of the on-site area. Materials and Methods: In this study, minimum detectable doses (MDDs) for $^{134}Cs$, $^{137}Cs$, and $^{131}I$ were calculated adjusting minimum detectable activities (MDAs) from 50 to 1,000 Bq to find out the optimal in-vivo counting condition. DCAL software was used to derive retention fraction of Cs and I isotopes in the whole body and thyroid, respectively. A minimum detect-able level was determined to set committed effective dose of 0.1 mSv for emergency response. Results and Discussion: We found that MDDs at each MDA increased along with the elapsed time. 1,000 Bq for $^{134}Cs$ and $^{137}Cs$, and 100 Bq for $^{131}I$ were suggested as optimal MDAs to provide in-vivo monitoring service in case of radiation emergencies. Conclusion: In-vivo monitoring program for emergency response should be designed to achieve the optimal MDA suggested from the present work. We expect that a reduction of counting time compared with routine monitoring program can achieve the high throughput system in case of radiation emergencies.

Comparison of Balance and Fall Efficacy of Virtual Reality Program in Elderly Women with Fall Experience

  • Park, Seong-Doo;Kim, Jin-Young;Yu, Seong-Hun;Yang, Kyung-Hee;Song, Hyun-Seung
    • The Journal of Korean Physical Therapy
    • /
    • v.26 no.6
    • /
    • pp.430-435
    • /
    • 2014
  • Purpose: The objective of this study was a virtual reality-based balance training program effective for improvement in physical function, examined the balance ability and fall efficacy of elderly women with experienced falls, intending to examine the program's usefulness as an exercise program to prevent the recurrence of a fall. Methods: The participants were 30 elderly women aged 65 or older who met the conditions. The participants were randomly assigned to either a balance training group (BT) or a virtual reality-based balance training group (VT) and received the training three times per week, 30 minutes per day, for six weeks. To measure static balance, the Tetrax Portable Multiple System (Tetrax Ltd, Israel) were used. To measure dynamic balance, the Berg Balance Scale (BBS) and functional reach test (FRT) was used, and regarding fall efficacy, the Korean Fall Efficacy Scale (K-FES) was used. Results: Tetrax significantly improved after the intervention in both the BT group and the VT group (p<0.05). The comparison between the two groups was not significantly. BBS and FRT result significantly improved after the intervention in both the BT and VT groups (p<0.001), while K-FES was significantly ameliorated in the VT group only (p<.05). Comparing the groups, there were more significant changes in the BBS (p<0.05) and FRT (p<0.01) result of the VT group than the BT group. Conclusion: A virtual reality-based balance training program is considered to be usable as an exercise program to prevent recurrence of falls in elderly women.

Pressure Regulation System for Optimal Operation of the Pneumatic VAD with Bellows-Type Closed Pneumatic Circuit (벨로우즈 방식의 폐회로를 가진 공압식 심실 보조장치의 최적 작동을 위한 압력 조절 시스템)

  • Kim, Bum-Soo;Lee, Jung-Joo;Nam, Kyung-Won;Jeong, Gi-Seok;Ahn, Chi-Bum;Sun, Kyung
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.4
    • /
    • pp.569-576
    • /
    • 2007
  • Ventricular Assist Device(VAD) has switched its goal from a short-tenn use for bridge-to-transplantation to a long-tenn use for destination therapy, With this goal, the importance of long-tenn reliability gets more interests and importances, H-VAD is an portable extracorporeal biventricular assist device, and adopts an electro-pneumatic driving mechanism. The pneumatic pressure to pump out blood is generated with compression of bellows, and is transmitted in a closed pneumatic circuit through a pneumatic line. The existing pneumatic VAD adopts a air compressor which can generate stable pressures but has defects such as a noise and a size problem. Thus, it is not suitable for being used as a portable device, These problems are covered with adopting a closed pneumatic circuit mechanism with a bellows which has a small size and small noise generation, but it has defects that improper pneumatic setting causes a failure of adequate flow generation. In this study, the pneumatic pressure regulation system is developed to cover these defects of a bellows-type pneumatic VAD. The optimal pneumatic pressure conditions according to various afterload conditions for an optimal flow rate were investigated and the afterload estimation algorithm was developed, The final pneumatic regulation system estimates a current afterload and regulate the pneumatic pressure to the optimal point at a given afterload condition. The afterload estimation algorithm showed a sufficient performance that the standard deviation of error is 8.8 mmHg, The pneumatic pressure regulation system showed a sufficient performance that the flow rate was stably governed to various afterload conditions. In a further study, if a additional sensor such as ultrasonic sensor is developed to monitor the direct movement of diaphragm in a blood pump part, the reliability would be greatly increased. Moreover, if the afterload estimation algorithm gets more accuracy, it would be also helpful to monitor the hemodynamic condition of patients.