EMERGING POSSIBILITIES FOR NIRS TO CONTRIBUTO TO ENVIRONMENTAL ANALYSIS

  • Malley, Diane
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1071-1071
    • /
    • 2001
  • Near-infrared spectroscopy (NIRS) is potentially a powerful and revolutionary technology for environmental analysis. It is supported by a large body of scientific and experiential knowledge. The instrumentation is well-developed, with easy-to-use, highly dependable instruments, but at the same time it is still developing, particularly with the production of more portable and rapid instruments, and more powerful software. NIRS is used globally in numerous industries for commodity analysis. Yet NIRS is largely unknown in the field of environmental chemistry and monitoring, and is not even routinely used in soil analysis, where the research literature on NIRS extends over four decades. Part of the explanation for the poor visibility of NIRS is the fact that NIRS is not routinely taught in Chemistry programs in universities, where most environmental chemists and environmental technicians are trained. This presentation examines the unique capabilities of NIRS, such as rapid, real-time analysis; analysis of whole samples; simultaneous analysis of multiple constituents; cost-effectiveness, and portability, as they match needs for analysis in several environmental areas. Examples of NIRS usage and published and unpublished results will be described for such areas as soil and sediment analysis; water quality monitoring; and nutrient loading in application of manures and sewage sludge (biosolids) to land. Present barriers to the use of NIRS in environmental analysis will be discussed. It is argued that emerging environmental problems and increasing attention to some traditional problems will enhance the application of NIRS in the future.

  • PDF

Development of a Hybrid fNIRS-EEG System for a Portable Sleep Pattern Monitoring Device (휴대용 수면 패턴 모니터링을 위한 복합 fNIRS-EEG 시스템 개발)

  • Gyoung-Hahn Kim;Seong-Woo Woo;Sung Hun Ha;Jinlong Piao;MD Sahin Sarker;Baejeong Park;Chang-Sei Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.392-403
    • /
    • 2023
  • This study presents a new hybrid fNIRS-EEG system to meet the demand for a lightweight and low-cost sleep pattern monitoring device. For multiple-channel configuration, a six-channel electroencephalogram (EEG) and a functional near-infrared spectroscopy (fNIRS) system with eight photodiodes (PD) and four dual-wavelength LEDs are designed. To enhance the convenience of signal measurement, the device is miniaturized into a patch-like form, enabling simultaneous measurement on the forehead. Due to its fully integrated functionality, the developed system is advantageous for performing sleep stage classification with high-temporal and spatial resolution data. This can be realized by utilizing a two-dimensional (2D) brain activation map based on the concentration changes in oxyhemoglobin and deoxyhemoglobin during sleep stage transitions. For the system verification, the phantom model with known optical properties was tested at first, and then the sleep experiment for a human subject was conducted. The experimental results show that the developed system qualifies as a portable hybrid fNIRS-EEG sleep pattern monitoring device.

Evaluation of Field Application of Portable Near Infrared Reflectance Spectrometer (NIRS) for Quality Evaluation of Italian Ryegrass Silages (신속한 이탈리안라이그라스 사일리지의 품질평가를 위한 소형 근적외선분광기(NIRS)의 현장 적용성 평가)

  • Park, Hyung-Soo;Lee, Sang-Hoon;Kim, Jong-Gun;Choi, Ki-Choon;Seo, Sung;Kim, Won-Ho;Lee, Hyo-Won;Lim, Young-Chul
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.31 no.4
    • /
    • pp.415-422
    • /
    • 2011
  • This study evaluated the feasibility of using a portable near infrared reflectance spectrometer working in the 900~1,600 nm range for the measurement of quality-related parameters (moisture, pH, Acid detergent fiber (ADF), Neutral detergent fiber (NDF), Crude protein (CP), lactic acid) in intact silage. The calibration result for the Phazir (handheld, Polychromix) was compared with the result for the Spectrastar (Lab. based, Unity). A total of 67 Italian ryegrass silages were used to build calibration models using different spectral signal pre-treatments and the partial least squares regression (PLS) method. The good calibration statistics in two instruments was obtained for moisture content of Italian ryegrass silages with over $R^2$ = 0.95. The Phazir spectrometer was less accurate in measuring of ADF, NDF and CP contents. The Spectrastar instrument yielded greater precision for pH and lactic acid content; statistic values were over $R^2$ = 0.82 and the standard error of calibration (SEC) = 0.21% and 0.24%. Thus, the NIR measurement of forage quality in the field by portable NIR analyzers was shown not to be feasible, but additional investigations are required to discern the key instrumental and operational parameters that may influence the portable NIR measurement.

Clinical Applications of Functional Near-Infrared Spectroscopy in Children and Adolescents with Psychiatric Disorders

  • Lee, Yeon Jung;Kim, Minjae;Kim, Ji-Sun;Lee, Yun Sung;Shin, Jeong Eun
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.32 no.3
    • /
    • pp.99-103
    • /
    • 2021
  • The purpose of this review is to examine the clinical use of functional near-infrared spectroscopy (fNIRS) in children and adolescents with psychiatric disorders. Many studies have been conducted using objective evaluation tools for psychiatric evaluation, such as predicting psychiatric symptoms and treatment responses. Compared to other tools, fNIRS has the advantage of being a noninvasive, inexpensive, and portable method and can be used with patients in the awake state. This study mainly focused on its use in patients with attention-deficit/hyperactivity disorder and autism spectrum disorder. We hope that research involving fNIRS will be actively conducted in various diseases in the future.

Near-infrared Spectroscopy and an Example of HAM Study;Brain Activation in the Development of Drawing Skills

  • Kobayashi, Harumi;Yasuda, Tetsuya;Suzuki, Satoshi;Takase, Hiroki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1745-1748
    • /
    • 2005
  • Near-infrared spectroscopy (NIRS) can be used to monitor brain activation by measuring changes in the concentration of oxy- and deoxy-hemoglobin (Hb) by their different spectra in the near-infrared range. Because NIRS is a noninvasive, highly flexible and portable device, it is very suitable to study brain activation when a human repeatedly performs a manipulative task, and possibly provides useful information to construct human adaptive mechatronics (HAM). There is some evidence that the dorsolateral prefrontal cortex (DLPFC) plays a major role in working memory and it is proposed that the use of working memory decreases as a human develops manipulative skills. In the present study, we investigated the activation of the dorsolateral prefrontal cortex (DLPFC) of the brain in Brodmann's areas 9 and 46 in drawing tasks to examine whether NIRS can measure the changes of DLPFC activation as a human develops manipulative skills. Subjects performed a mirror image drawing task and a square drawing task by ones' left hands. In the mirror image task the subject drew following a star shape based on a mirror image of it, but square drawing did not involve mirror image and was estimated to be simpler. The changes of the concentration of oxy-Hb was higher in the mirror image drawing than the square drawing in most subjects. The changes of oxy-Hb decreased as the subject repeated the drawing task in most subjects. In conclusion, The activation of DLPFC measured by NIRS can reflect the brain activity in the development of manipulative skills.

  • PDF

Determination of the water content in Citrus leaves by portable near infrared (NIR) system

  • Suh, Eun-Jung;Lim, Hun-Rang;Woo, Young-Ah;Kim, Hyo-Jin
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.405.1-405.1
    • /
    • 2002
  • The amount of water for the cultivation of citrus is different based on the growing period. The water content in the leaves of citrus can be a index for watering during cultivation. The purpose of this study is to determine non-destructively the water content of Citrus leaves by using near infrared spectroscopy (NIRS). Citrus leaves were prepared from satsuma mandarin leaves (Citrus unshiu Marc. var. okitsu) ranging from 62.20 to 69.98% of water content by loss on drying, NIR reflectance spectra of Citrus leaves were acquired by using a fiber optic probe. (omitted)

  • PDF

Determination of the water content in citrus leaves by portable near infrared (NIR) system (근적외분광분석법을 이용한 감귤잎의 수분 측정)

  • Suh, Eun-Jung;Woo, Young-Ah;Lim, Hun-Rang;Kim, Hyo-Jin;Moon, Doo-Gyung;Choi, Young-Hun
    • Analytical Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.277-282
    • /
    • 2003
  • The amount of water for the cultivation of citrus is different based on the growing period. The effect of water stress induces to enhance of sugar accumulation in citrus. The water content in the leaves of citrus can be a index for watering during cultivation. The purpose of this study is to determine the water content of citrus leaves non-destructively by using near infrared spectroscopy (NIRS). Citrus leaves were prepared from 'Okitsu' Satusuma mandarin leaves (Citrus unshiu Marc.) ranging from 20.80 to 69.98% of water content by loss on drying method, and NIR reflectance spectra of citrus leaves were acquired by using a fiber optic probe. It was found that the variation of absorbance band 1450 nm from OH vibration of water depending on the water content change. Partial least squares regression (PLSR) was applied to develop a calibration model over the spectral range 1100-1700 nm. The calibration model predicted the water content for the validation set with a standard errors of prediction (SEP) of 0.97%. In order to validate the developed calibration model, routine analyses were performed using independently prepared citrus leaves. The NIR routine analyses showed good results with those of loss on drying method with a SEP of 0.81%. The rapid and non-destructive determination of the water content in citrus leaves was successfully performed by portable NIR system.