• 제목/요약/키워드: Pool Type

검색결과 275건 처리시간 0.026초

GTA 용접시 발생하는 용융금속의 유동에 미치는 공기역학적 향력의 영향 (Effect of aerodynamic drag force on liquid metal convection in GTA welding)

  • 나석주;김성도
    • 대한기계학회논문집
    • /
    • 제15권2호
    • /
    • pp.575-583
    • /
    • 1991
  • The weld pool convection problem that occurs during the stationary GTA welding has been studied, considering the four driving forces for weld pool convection, i.e., the electromagnetic force, the buoyancy force, the aerodynamic drag force, and the surface tension force at the weld pool surface. In the numerical simulation, the difficulties associated with the irregular moving liquid-solid interface have been successfully overcome by adopting a Boundary-Fitted Coordinate system. In the experiments to show the validity of the numerical analysis, a deep periphery and shallow centerpentrated weld pool shape was observed from the etched specimen. It could be revealed that this type of weld pool shape could be simulated, only when some of aerodynamic drag force distributions are considered. Although slight disagreement arose, the calculated and the observed weld pool shapes were in a reasonable agreement.

원통형 문풀 구조물의 탑재 시 변형과 수정 (Welding Deformation and Its Correction of Cylindrical Moon Pool Structure)

  • 성우제;천광산
    • 대한조선학회논문집
    • /
    • 제56권5호
    • /
    • pp.389-395
    • /
    • 2019
  • Turret mooring type Floating Production Storage and Offloading (FPSO) is designed to rotate the hull around a turret system. The system is mounted inside a cylindrical moon-pool structure of the ship hull structure. The upper part of the moon-pool structure called Bogie Support Structure (BSS) is supported on ring type rail structure (bogie), so high roundness is required at the top of the structure. In this study, the deformation measured during BSS installation was compared with the predicted values through the thermal elasto-plastic analysis, and the causes of deformation were analyzed. Deformation behavior of cylindrical structure with a very large diameter compared to the thickness was investigated. In addition, a proper welding sequence and correction method for the deformed structure were proposed. This study can be an example of the solution to the tolerance problem of large cylindrical structures.

분무수 분무특성이 액체연료 Pool 화염의 소화에 미치는 영향 (Effects of Spray Characteristics of Water Mist on The Extinction of a Liquid Pool Fire)

  • 김호영;오상엽;정진택
    • 대한기계학회논문집B
    • /
    • 제28권12호
    • /
    • pp.1591-1599
    • /
    • 2004
  • A series of experiments were conducted to study the effectiveness of the extinction of a liquid pool fire with two different water atomizing nozzles. Fire source is a small-scale circular stainless steel pan of 120mm in diameter with the fuels of hexane and ethanol. K-type thermocouples were used to measure the flame and fuel temperature along the pool centerline and under fuel surface. A digital camera was used to visualize the process of the fire suppression. The experimental results show that water mist droplet size is l15∼180${\mu}{\textrm}{m}$ with nozzle A and 130∼190${\mu}{\textrm}{m}$ with nozzle B. The extinguishing time of pool fire was reduced with the increase of pressure. When water droplets are small, they do not reach the flame base since they may be deflected or evaporated by the fire plume. However, influence of flow rate is more important than droplet size on fire extinction. Among the fire extinction mechanisms, drop of flame temperature is superior to suffocation of $O_2$ concentration.

미분무수 분무특성이 액체연료 Pool 화염의 소화에 미치는 영향 (The Effects of Spray Characteristics of Water Mist on the Fire Suppression of Liquid Pool Fire)

  • 오상엽;김호영;정진택
    • 한국연소학회:학술대회논문집
    • /
    • 대한연소학회 2003년도 제27회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.215-221
    • /
    • 2003
  • A series of experiments were conducted to study the effectiveness of the extinction of a liquid pool fire with two different water atomizing nozzles. Fire source is small-scale circular stainless steel pan of 120mm in diameter with the fuels of hexane and ethanol. K-type thermocouples were used to measure the flame and fuel temperature along the pool centerline and under fuel surface. A digital camera was used to visualize the process of the fire suppression. The experimental results show that water mist droplet size is $115{\sim}180{\mu}m$ with nozzle A and $130{\sim}190{\mu}m$ with nozzle B. The extinguishing time of pool fire was reduced with the increase of pressure. When water droplets are small, they do not reach the flame base since they may be deflected or evaporated by the fire plume. However, influence of flow rate is more important than droplet size on fire extinction. Among the fire extinction mechanisms, drop of flame temperature is superior to suffocation of O2 concentration.

  • PDF

파형 단면을 가진 유하식 집열기의 열적 성능에 대한 이론 및 실험 연구(I) (An Analytical & experimental study on the thermal performance of trickle solar collector with Sinuous Cross-section)

  • 이종호;정모;백남춘;오정무
    • 대한설비공학회지:설비저널
    • /
    • 제12권4호
    • /
    • pp.240-251
    • /
    • 1983
  • The municipal government of Daejeon, Korea set up a plan to retrofit solar energy to the existing swimming pool. The pool was constructed in 1980, and meets the requirements of International standard. It will be used for the 1986 Asian Games and the 1988 Seoul Olymipics. The roof structure of the existing pool is to be modified to accomodate trickle solar collectors. In addition, various energy conserving ideas will be applied to the existing building structure. For the prevention of over heating of collectors on the roof, natural air convection scheme will be adopted within the collector system. Natural convection of passive type heating would be also adopted for the space heating of the pool when the system is idle. At present, the pool can be utilized only for two months a year without auxilairy heating. With oil heating, the energy cost would be too high for the normal operation. When this project completed in March 1984, it would be expected to be openable for seven months a year without a significan amount of auxiliary heating. In this project, two dimensional numerical analysis technic have been used to analyse the characterisitics of thermal performance of the swimming pool system. An experimental tat verification of the theoretical analysis have been also attempted.

  • PDF

남한강 수계 양화천의 서식처 유형별 어류상 및 분포특성 (The Characteristic of Fish Fauna and Distribution by Habitat Type in the Yanghwa Stream of the Namhan River Basins)

  • 이승현;이황구;신현선;최준길
    • 한국환경생태학회지
    • /
    • 제26권6호
    • /
    • pp.884-891
    • /
    • 2012
  • 2008년 8월부터 2009년 6월까지 양화천의 8개 미소서식처 유형에 따른 어류상 및 군집의 분포특성을 조사하였으며, 조사기간 동안 채집된 어류는 총 8과 30종 2,797개체가 확인되었다. 출현한 어종 중 한국고유종은 Rhodeus uyekii 등 총 10종(33.3%)으로 확인 되었으며, 우점종은 Rhodeus notatus, 아우점종은 Pseudorasbora parva였다. 서식처 유형별 우점종은 댐형 웅덩이, 개방형 하도습지에서 Pseudorasbora parva, 평여울에서 Pseudogobio esocinus, 급여울에서 Zacco platypus, 샛강, 낙차형 웅덩이에서 Rhodeus notatus, 사행형 웅덩이에서 Squalidus gracilis majimae, 폐쇄형 하도습지에서 Carassius auratus가 우점하였다. 군집분석 결과 우점도지수는 낮고, 다양도지수, 균등도지수, 풍부도지수는 높게 나타나 서식처 유형별 비교적 안정적인 군집구조를 유지하고 있는 것으로 분석되었다. 유사도 분석과 주성분 분석 결과 8개의 서식처 유형들이 유수역 특성이 나타나는 서식처와 정수역 특성이 나타나는 서식처로 구분되어 분석되었다.

구형 면진유체저장조의 지진시 거동해석 (Seismic Response Analysis of Rectangular Tank with Base-Isolation System)

  • 전영선;최인길;황신일;김진웅
    • 전산구조공학
    • /
    • 제8권1호
    • /
    • pp.107-113
    • /
    • 1995
  • 사용후핵연료 저장조는 지진하중에 대하여 운영기간중 자체의 구조적 건전성 및 저장된 사용후핵료의 안전성을 확보할 수 있어야 한다. 본 연구에서는 LRB 면진장치를 설치한 사용후핵연료 면진저장조의 지진시 거동특성을 파악하기 위하여 서로 다른 특성을 갖는 두종류의 지진에 대하여 지진해석을 하여 그 결과를 비면진 저장조에서의 응답과 비교하였다. 면진장치를 사용함으로써 지진시 상부구조로 전달되는 지진력과 응답을 크게 감소시켜 저장조와 저장된 사용후액연료의 안전성 확보에 유리한 것으로 나타났다.

  • PDF

물-$TiO_2$ 나노유체 풀비등에서의 임계열유속 (Critical heat flux behavior in pool boiling of $water-TiO_2$ nanofluids)

  • 김형대;김무환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1470-1474
    • /
    • 2004
  • 'Nanofluids' means suspension of common fluids with particles of the order of nanometers in size. The present research is an experimental study of critical heat flux (CHF) behavior in pool boiling of $water-TiO_2$ nanofluids under atmospheric pressure. CHF for pure water and $water-TiO_2$ nanofluids were respectively measured using disk-type copper block heater with 10mm diameter, and CHF of water with surfactant was also measured to consider the effect of surfactant used to disperse nanoparticle. The results show a large increase in CHF for $water-TiO_2$ nanofluids compared to pure water. After CHF occurred, heat flux in pool boiling for $water-TiO_2$ nanofluids was maintained in considerable value, but not for pure water.

  • PDF

5MW 연구용 원자로의 1차 냉각 계통 유동 특성 (Flow Characteristics of a Primary Cooling System in 5 MW Research Reactor)

  • 박용철;이용섭
    • 한국유체기계학회 논문집
    • /
    • 제13권5호
    • /
    • pp.5-10
    • /
    • 2010
  • 5MW, open pool type research reactor, is commonly used to education and experimental purpose. It is necessary to prepare a standardization of system designs for considering a demand. HANARO has prepared the standardization of 5MW research reactor system designs based on the design, installation, commissioning and operating experiences of HANARO. For maintaining an open pool type reactor safety, a primary cooling system (after below, PCS) should remove the heat generated by the reactor under a reactor normal operation condition and a reactor shutdown condition. For removing the heat generated by the reactor, the PCS should maintain a required coolant flow rate. For a verification of the required flow rate, a flow network analysis of the PCS was carried under a normal operating condition. Based on the flow network analysis result, this paper describes the PCS flow characteristics of a 5MW open pool type research reactor. Through the result, it was confirmed that the PCS met design requirements including design flow rate without cavitation.

DESIGN STUDY OF AN IHX SUPPORT STRUCTURE FOR A POOL-TYPE SODIUM-COOLED FAST REACTOR

  • Park, Chang-Gyu;Kim, Jong-Bum;Lee, Jae-Han
    • Nuclear Engineering and Technology
    • /
    • 제41권10호
    • /
    • pp.1323-1332
    • /
    • 2009
  • The IHX (Intermediate Heat eXchanger) for a pool-type SFR (Sodium-cooled Fast Reactor) system transfers heat from the primary high temperature sodium to the intermediate cold temperature sodium. The upper structure of the IHX is a coaxial structure designed to form a flow path for both the secondary high temperature and low temperature sodium. The coaxial structure of the IHX consists of a central downcomer and riser for the incoming and outgoing intermediate sodium, respectively. The IHX of a pool-type SFR is supported at the upper surface of the reactor head with an IHX support structure that connects the IHX riser cylinder to the reactor head. The reactor head is generally maintained at the low temperature regime, but the riser cylinder is exposed in the elevated temperature region. The resultant complicated temperature distribution of the co-axial structure including the IHX support structure may induce a severe thermal stress distribution. In this study, the structural feasibility of the current upper support structure concept is investigated through a preliminary stress analysis and an alternative design concept to accommodate the IHTS (Intermediate Heat Transport System) piping expansion loads and severe thermal stress is proposed. Through the structural analysis it is found that the alternative design concept is effective in reducing the thermal stress and acquiring structural integrity.