• Title/Summary/Keyword: Pool 길이

Search Result 55, Processing Time 0.029 seconds

Numerical simulations of turbulent flow on the pool and weir type fishway and analysis of ascending possibility of fishes (계단식 어도의 난류흐름 수치해석 및 어류 소상 가능성 분석)

  • Kwon, Yong-Joon;Ryu, Yonguk;Kim, Hyung Suk
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.spc1
    • /
    • pp.1037-1048
    • /
    • 2023
  • Fishways are constructed to ensure the fish migration because river-crossing structures such as dams and weirs cut off the stream longitudinal connectivity and influence on aquatic ecosystems. However, the passage efficiency of fishes varies depending on flow characteristics in the fishway and fish species. In this study, three-dimensional numerical simulations are carried out using a RANS model and the volume of fluid method for resolving free surface fluctuations to calculate the turbulent flow in the pool and weir type fishway. The Flow velocity and turbulent kinetic energy in the pool of fishway are analyzed according to variation of the upstream water level and the length of pool. The present numerical simulations reasonably well reproduce the stream flow and plunging flow characteristics in the pool. The simulation results show that the stream flow changes to the plunging flow as the length of the pool increases. When the upstream level increases, the stream flow becomes more evident. Key parameters related to the fish migration within the fishway such as the flow velocity and the turbulent kinetic energy are examined to assess the ascending possibility of fishes.

Pool Boiling Heat Transfer in a Vertical Annulus with a Longer Outside Tube (외부 튜브 길이가 긴 수직 환상공간 내부의 풀비등 열전달)

  • Kang, Myeong-Gie
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.8
    • /
    • pp.775-782
    • /
    • 2012
  • To investigate pool boiling heat transfer in a vertical annulus with closed bottoms, the length of an outer tube was varied between 0.3 and 0.6 m. For the test, a heated tube of 0.2-m length and 19.1-mm diameter and water at atmospheric pressure were used. To elucidate the effects of the outer tube length on heat transfer, the results for the annulus were compared with data for a single unrestricted tube. The increase in the outer tube length resulted in an increase or decrease in heat transfer depending on the gap size. This tendency is mainly attributed to the difference in the intensity of liquid agitation.

Characteristics of step-pool structure in the mountain streams around Mt. Jiri (지리산 주변 산지하천의 step-pool 구조 특성)

  • Kim, Ki Heunga;Jung, Hea Reyn
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.4
    • /
    • pp.313-322
    • /
    • 2018
  • The height of the steps was almost the same as the grain size of bed materials and increased with channel slope. The step widths and step wavelengths are almost the same size, and the step wavelength was decreased when the channel slope was increased. It was analyzed that there was a clear correlation between channel width and step width, and the step width increases with channel width. In addition, the step wavelength was scaled by channel width, and the step height is governed by the grain size of the rock forming the step, so that the profile structure of the step-pool was changed according to the channel slope. the scale of the pool was found to be highly correlated with the channel width, grain size, and slope gradient. Therefore, the characteristics of step-pool structure in mountain streams were influenced by various factors, but it can be explained as the grain size, channel width and channel slope.

A Study of Smoke Spread and Flow in a Long Corridor (복도에서의 연기 확산 및 유동에 관한 연구)

  • 김충익;유홍선;김명배;한용식;김진곤;윤명오;김상욱
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1998.11a
    • /
    • pp.29-39
    • /
    • 1998
  • 복도는 사무실용 건물, 호텔 등 공중이용 건물에서 중요한 피난경로의 일부이다. 화재로 복도에 연기가 확산되면 그 온도, 연층의 높이, 유해물질의 농도 등에 따라 피난에 심각한 장애를 가져올 수 있다. 본 연구는 이러한 복도에서의 연기의 확산 및 유동에 관하여 연구하기 위하여 길이 40m의 복도에서 pool fire로부터의 연기 유동에 관한 실제크기의 실험과 수치해석을 수행하였다. 화재실과 그에 접해있는 긴 복도가 있는 실험장치에 직경 15, 20, 30cm의 가솔린 pool을 화재실 중앙에서 점화 시켰다. 연기의 온도 및 이동을 측정하기 위해 전장 중앙선을 따라 열전대를 설치하였고 연층의 두께를 측정하기 위하여 수직방향으로 세곳에 열전대가 부착된 수직봉을 설치하였다. 아르곤 레이저 sheet 과 비디오 카메라를 이용해 연기의 유동을 가시화 하였다.

  • PDF

Dimensional Measurement of Spent Fuel Assemblies Using Image Processing Technique (영상처리기술에 의한 사용후핵연료 집합체의 제원 측정)

  • Koo, Dae-Seo;Park, Seong-Won
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.1
    • /
    • pp.9-13
    • /
    • 2002
  • A pool image processing measurement method has been developed to improve the examination efficiency and to minimize the errors of dimensional measurements of spent fuel assemblies in pool. Diameter and length measurements of mock-up fuel rods using the image processing system are $-0.24{\pm}0.03mm,\;0.34{\pm}0.06mm$ on the basis of the true value and their maximum errors are within -0.3 and 0.4mm, respectively, According to the result of dimensional measurement of spent fuels in pool, the upper and lower part diameter and mid part diameter of fuel rods of the J44 fuel assembly irradiated for 2 cycles in the Kori-2 nuclear reactor were decreased by about 2.0 and 3.0% in comparison with design values, respectively. The length of fuel rods was elongated by about 0.4%. The change behavior of diameter and length. of fuel rods of the F02 fuel assembly irradiated for 3 cycles in the Kori-1 nuclear reactor showed a trend similar to the results of J44.

Experimental Study on Characteristics of Steam Condensation in a Sub-cooled Water Pool (과냉각수조에서 증기응축 특성에 관한 실험적 연구)

  • Kim, Hwan-Yeol;Cho, Seok;Song, Chul-Hwa;Chung, Moon-Ki;Choi, Sang-Min
    • Journal of Energy Engineering
    • /
    • v.8 no.2
    • /
    • pp.298-308
    • /
    • 1999
  • Experimental study on characteristics of direct contact condensation of steam discharged into a sub-cooled water pool has been performed using five different sizes of horizontal nozzle over a wide range of steam mass fluxes and pool temperatures. Steam condensation phenomena have been observed visually and by taking pictures of steam jets using a high speed video camera. Two different steam jet shapes such as ellipsoidal shape and conical shape were typically observed for a stable steam jet, depending on the steam mass flux and pool temperature. The steam jet expansion ratio and the steam jet length as well as the condensation heat transfer coefficients were determined. The effect of steam mass flux, pool temperature, and nozzle diameter on these parameters were also discussed. Empirical correlations for the steam jet lengths and the condensation heat transfer coefficients as a function of steam mass flux and condensation driving potential were established. The axial and radial temperature distributions in steam jet and in surrounding water were measured. The effect of steam mass flux, pool temperature, and nozzle diameter were also discussed. The condensation regime map, which consists of six regimes such as chugging, transient chugging, condensation oscillation, stable condensation, bubble condensation oscillation, and intermittent oscillation condensation, were established. In addition, the dynamic pressures at the pool wall were measured. The close relation of dynamic pressure and steam condensation mode, which is also dependent on steam mass flux and pool temperature, was found.

  • PDF

Physio-biochemical changes correlated with cadmium adaptation and detoxification mechanism in klebsiella aerogenes (Klebsiella aerogenes의 카드뮴 적응 및 해독기작에 관련된 생리생화학적인 변화)

  • 이기성;송인극;박영식;윤성녀;최영길
    • Korean Journal of Microbiology
    • /
    • v.28 no.3
    • /
    • pp.249-257
    • /
    • 1990
  • In the course of operating the accommodative and detoxifying mechanism against cadmium, its physio-biochemical changes were observed in Klebsiella aerogenes ATCC 10031. Changes of enzyme activity concerned phosphate metabolism, changes of phospholipid composition and in view of energy metabolism the changes of the nucleotide pool were examined. Activities of both alkaline and acid phosphatase were derepressed 4-10 folds under cadmium added cultures. Moreover, production of phospholipid such as lysophosphatidyl choline (LPC), phosphatidyl serine (PS) and phosphatidyl ethanolamone (PE) was increased and uridylate nucleotide pool was increased under Cd-surplus culture. These results i.e. overproduction of phosphatase catalyzing phosphate residue, increase of the production of PE and PS which have a close affinity with cadmium, and indrease of uridylate nucleotide pool used as a carrier of polysaccharide synthesis like bacterial capsule exhibited cellular responses for active defence against Cd-pressure. It was postulated that these phenomena should play another assistant roles in Cd-detoxifing mechanism.

  • PDF

Calculation of the Dispersion Coefficient by the Dissolution Experiment of DNAPL Pool (DNAPL Pool의 용해실험에 의한 분산계수 산정)

  • 정경영;배열호;최상일
    • Journal of Korea Soil Environment Society
    • /
    • v.1 no.1
    • /
    • pp.19-27
    • /
    • 1996
  • Nonaqueous phase liquids(NAPL) not readily dissolved in water exist as a separate fluid phase. Groundwater contamination by NAPL such as organic solvents and petroleum hydrocarbons becomes major public concerns because of their long-term persistence in the subsurFace and their ability to contaminate large volumes of wate. Dense.-than-water NAPL(DNAPL) spilled into the subsurface penetrate through the saturated zone and ultimately form DNAPL pools on the bottom of the aquifer. The dissolution of DNAPL from these pools depends on the molecular diffusion coefficient, the vertical dispersivity, the groundwater velocity, the solubility, and the pool length. In this study, the vertical transverse dispersion coefficients for simulating the dissolution of DNAPL from such pools were obtained from the dissolution experiment. Under the experimental conditions used, the vertical transverse dispersion coefficients calculated were 1.86$cm^2$/day, 2.90$cm^2$/day and 4.51$cm^2$/4ay for seepage velocities of 59.2cm/day, 94.3cm/day and 158.0cm/day, respectively. And the vertical transverse dispersivity was 0.03024cm.

  • PDF

Effects of Outer Tube Length on Pool Boiling in an Annulus with Closed Bottoms (하부폐쇄 환상공간의 외부 튜브길이가 풀비등에 미치는 영향)

  • Kang Myeong-Gie
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.8 s.251
    • /
    • pp.749-755
    • /
    • 2006
  • To improve pool boiling heat transfer in an vertical annulus with closed bottoms, the length of an outer tube has been changed from 0.2m to 0.6m. For the test, a heated tube of 19.1mm diameter and water at atmospheric pressure have been used. Annular conditions are made using glass tubes fabricated around the heated tube. The gap size of the annulus is 3.65mm. To elucidate effects of the outer tube length on heat transfer results of the annulus are compared with the data of a single unrestricted tube and the annulus with wider gap size of 6.35mm. Throughout the tests much higher heat transfer coefficients are observed for the annulus of 3.65mm gap size comparing to the other two cases. The change in the outer tube length results in much variation in heat transfer coefficients. Moreover, with shortening the length of outer tube the possibility of the CHF occurrence can be removed.