• Title/Summary/Keyword: Pond system

Search Result 219, Processing Time 0.029 seconds

Constructing Landscape as an Operational Multi-Environmental Control Utility and Green Infrastructure - Landscape Design for National Marine Biology Resource Institute - (작동하는 복합환경조절장치 및 녹색기반시설로서 조경 - 국립해양생물자원관 옥외공간 설계 -)

  • Sung, Jongsang
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.15 no.2
    • /
    • pp.41-56
    • /
    • 2012
  • Landscape space can and should play as a multi-functional agent : healing contaminated soil, reducing natural hazards, supporting living things, making comfortable environment for human, and appealing to human aesthetics, etc. This article aims to show the possibility and role of landscape space as such agent. In landscape design for National Marine Biology Resource Institute, distributed rain water treatment system and rain gardens are introduced to replace a mono-functioning large detention pond which was suggested by disaster impact assesment. Phytoremediation and vegetation filtering system with muti-cell wetlands are also adapted to heal the contaminated soil. This kind of landscape as a 'living machine' which can play as an operational control utility of multi-environment and thus can be combined effectively into green infrastructure is important for post-industrial city, especially in an era of climate change.

Efficiency of Apatite and Limestone in Removing Arsenic from Acid Rock Drainage at the Goro Abandoned Mine (인회석 및 석회석을 이용한 고로폐광산 ARD 내의 비소 저감효율 연구)

  • Park, Myung-Ho;Lee, Young-Woo;Hur, Yon-Kang;Park, Hae-Cheol;Sa, Sung-Oh;Choi, Jung-Chan
    • The Journal of Engineering Geology
    • /
    • v.21 no.3
    • /
    • pp.231-237
    • /
    • 2011
  • An active apatite drainage system has been developed at the Goro abandoned mine, comprising a grit cell, a reaction cell, and a precipitation pond. Leachate from an abandoned adit and tailing ponds is collected in a pipeline and is transported to the apatite drainage system under the influence of the hydraulic gradient. The results of a laboratory experiment performed in 2004 indicate that the reaction cell requires 38.8 ton/year of apatite and that precipitate will have to be removed from the precipitation pond every 3 months. The purpose of this study is to evaluate a laboratory test on the efficiency of limestone and apatite in removing arsenic from ARD (acid rock drainage), and to evaluate the suitability of materials for use as a precipitant for the leachate treatment disposal system. The laboratory tests show that the arsenic removal ratios of limestone and apatite are 67.4%-98.3%, and the arsenic removal ratio of apatite is inversely proportional to its grain size. The arsenic compounds are assumed to be Johnbaumnite and Ca-arsenic hydrate. Therefore, apatite and phosphorous limestone can be used as a precipitant for the removal of arsenic, although it is difficult to remove arsenic from ARD when it occurs in low concentrations.

An Experimental Study on the Pond Sediment and Water Quality Purification using Oxygen Solubilization Device(OSD) System (산소용해수를 이용한 호소 저질 및 수질개선에 관한 실험적 연구)

  • Kim, Young-Taek;Bae, Yoon-Sun;Roh, Eun-Kyung;Park, Chul-Hwi;Lee, Yeon-Ku
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.1
    • /
    • pp.94-103
    • /
    • 2006
  • The pollution in closing water can be caused by not only artificial factor like sewage but also natural factor like elution from sediment. In this study we analyzed Sediment Oxygen Demand (SOD) for verification of sediment purification effect and sediment elution experiment as well as general items like COD, TN, TP, SS to complement and assess the effect of sediment and water quality. The experiment result showed that the release rate of OSD system were 4 times and 3 times as large as control for P and Fe respectively. SOD for operated OSD system and control were $12.18gO_2{\cdot}m^{-2}{\cdot}d^{-1}$ and $47.95gO_2{\cdot}m^{-2}{\cdot}d^{-1}$. From water qualities analyzed by COD, TN, TP, SS, chlorophyll-a, the removal efficiency increase of TN, TP, chlorophyll-a and COD were about 10~20%, 40~50% and 10% respectively. In conclusion, OSD can contribute to improvement of both the waterbody and the sediment environment effectively.

Preliminary Analysis on Design Parameters and Application Effects of Surface Water Heat Exchanger (SWHE) (지표수 열교환기 설계 변수와 적용 효과에 대한 선행 분석)

  • Sohn, Byonghu
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.12 no.3
    • /
    • pp.24-32
    • /
    • 2016
  • Commercial buildings and institutions are generally cooling-dominated and therefore reject more heat to a borehole ground heat exchanger (BHE) than they extract over the annual cycle. Shallow ponds can provide a cost-effective means to balance the thermal loads to the ground and to reduce the length of BHE. This paper presents the analysis results of the impact of design parameters on the length of SWHE pipe and its application effect on geothermal heat pump (GHP) system using BHE. In order to analysis, we applied ${\varepsilon}-NTU$ method on designing the length of SWHE pipe. Analysis results show that the required pipe length of SWHE was decreased with the increase of approach temperature difference and with the decrease of pipe wall thickness. In addition, when the SWHE was applied to the GHP system, the temperature of BHE was more stable than that of standalone BHE system.

Basic Study on Conditions and Analytical Methods of Biofilm Formation for the Bioassessment of Artificial Groundwater Recharge System (지하수 인공함양시스템의 생물학적 평가를 위한 생물막 형성 조건 및 형성도 분석 방법에 관한 기초연구)

  • Kong, In Chul;Lee, So Ra;Ha, Kyoochul;Ko, Kyung-Seok
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.4
    • /
    • pp.22-30
    • /
    • 2015
  • For the preliminary investigations of the bioclogging on groundwater artificial recharge system, studies for conditions and analytical methods of biofilm formation on sediments were performed. Based on the tested results, following conditions were determined for biofilm formation on batch process: optimum period for biofilm formation (30 days), the proper inoculating water (pond water), medium (minimum salt medium with 0.1% yeast extract). Procedures for the measurement of ATP and DHA were also determined. Biomass extract was used for ATP measurement, while sediment itself for DHA. Effects of metals on the biofilm formation were investigated under the determined conditions. Different sensitivities and orders were found depending on tested metals and measurement methods. In general, biomass measurement by ATP and viable cell count showed higher sensitivity than that of DHA. Following toxicity orders were also appeared for ATP and viable cell: Cu ≈ Cd > As(III).

Constructed Wetland Design Method to Treat Agricultural Drainage from Tidal Reclaimed Paddy Areas (간척지 논 농업배수 처리에 적합한 인공습지 설계 기법)

  • Jang, Jeong-Ryeol;Shin, Yu-Ri;Jung, Ji-Yeon;Choi, Kang-Won
    • KCID journal
    • /
    • v.18 no.1
    • /
    • pp.4-17
    • /
    • 2011
  • The standard design methodology was suggested to construct wetland system for reducing non-point source pollution from Saemangeum reclaimed paddy land. To set for the design flow and concentrations, runoff and water quality survey were conducted during the irrigation period in 2008 at Gyehwa reclaimed paddy land located at near Saemangeum lake. It is rational that 1ha is the optimum constructed wetland size. To meet this size, the moderate drainage area of reclaimed paddy field was 50ha under the conditions that rainfall is 30mm, average runoff coefficient is 0.83, and runoff capture ratio is 0.6. At these condition, the runoff volume from 50ha was 10,520 $m^3/d$ including base flow during irrigation period. To select the optimum wetland system, several case studies were conducted by focusing on the tidal reclaimed land areas having wetland systems in Seokmun. Pond-Wetland system was selected as the standard model because of showing the highest reduction efficiency. Single variable regression equation were delivered to estimate effluent water concentrations from the designed wetland by using long-term monitoring data from the Seokmun experiment site. The effluent concentration from the designed wetland using these equation were showed moderately range.

  • PDF

Toege and the Architecture of Dosan Sodang (퇴계(退溪)의 건축관(建築觀)과 도산서당(陶山書堂))

  • Kim, Dong-Uk
    • Journal of architectural history
    • /
    • v.5 no.1 s.9
    • /
    • pp.18-38
    • /
    • 1996
  • Dosan Sedans was built in 1560, when Toege I Whang(1500-1571) was 60, as a place in which to study and teach disciples. The building was built to a humble 3-kan system which was a popular form of sodang in the 16th century, There found an enlargement of space by attaching outer walls around three sides which was designed by Toege himself. Minimum in space, moderation in form, conrol of embellishment, hermit scholar's aethetics became basic concept of the architecture of Dosan Sodang. After completion of sodang, Toege wrote many poems about pond, walls, flower bed and natural surroundings like sheer cliff, winding river and even rural daily life of villagers around the building. It could be sud that ,for Toege, architecture was cogniged as a whole complex of building and its surrounding natural, artificial and human circumstances.

  • PDF

Heavy Rain and Flood Prevention in Urban (뉴스초점: 집중호우와 도시지역 홍수방어)

  • Jeong, Sun-Gil
    • Journal of the Korean Professional Engineers Association
    • /
    • v.43 no.6
    • /
    • pp.31-34
    • /
    • 2010
  • Recently, due to localized heavy rain and flash floods in urban areas is becoming more frequent flood damage. To prevent flood inundation damage, to formulate the diverse directions in connection with the drainage system of buildings, roads, sewerage, pump stations, detention (retention) pond, and streams is very important. In addition, it is important for the uniform design criteria, the consistent of hydrologic and hydraulic analysis method, and a flood disaster mitigation systems connected with structural and nonstructural measures. To accomplish this, the method such as installation of storage facilities, infiltration facilities, and underground water tank, the optimal size of the design gutter and grate of the road, ensure the capacity of pumping stations, and the installation of a flood control channel into the deep underground requires comprehensive measures dimension in urban areas.

  • PDF

The Meaning, Method and Tool to Build the Ewha Music Database (EMDB)

  • Kim, Eun-Ha;Chae, Hyun Kyung
    • International journal of advanced smart convergence
    • /
    • v.9 no.3
    • /
    • pp.239-245
    • /
    • 2020
  • The Ewha Music Database (EMDB) is an online database comprised of primary source materials related to music education from East Asia during the modern era (1880 to 1945) when Korea, Japan, and China were geopolitically and culturally intertwined. We developed the incipit search in EMDB as an embedded tool. This is the first attempt in Korea to implement a unique search function of musical data using alphabets of musical notes. Unlike in traditional search system that uses general literature information search conditions, such as author, title, publisher, year, number of pages, etc., it offers a new way of searching a musical piece/work and sheet music. This study confirms that digital information technology is an important methodology for research of music culture as a field of humanities.

Present and Future of Green Hospitals in Korea (종합병원의 친환경적 시설 실태와 향후 과제)

  • Seo, Youngjoon;Kang, Shinhee;Kim, Yeon-Hee;Lee, Yong-Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.16 no.1
    • /
    • pp.43-53
    • /
    • 2010
  • This study purports to investigate the status quo of the environmentally-friendly green healthcare in teaching hospitals through the questionnaire survey. Data were collected from a total of 46 hospitals. The survey results revealed that most teaching hospitals did not meet the global standard of environmentally-friendly green hospitals. Especially, such items as alternative energy system, water recycling, CO2 emission reduction, green building construction, installation of pond or spring were found to be significantly below global standard. Based upon the study results, various strategies for establishing green hospitals were discussed. For example, energy saving design, such as solar heating, natural wind cooling, automatic temperature controller, green material use, wall surrounded by ivy, were recommended. In conclusion, the strategy and evaluation tool developed in the study will provide a good guide for establishing environmentally-friendly green hospitals.