• Title/Summary/Keyword: Polyurethane.

Search Result 1,615, Processing Time 0.022 seconds

Design of $2{\times}1$ Array Antenna Using Stack Structure for IEEE 802.11a (적층구조를 이용한 IEEE 802.11a용 $2{\times}1$ 배열 안테나 설계)

  • Park, Jung-Ah;Bu, Chong-Bae;Kim, Kab-Ki
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.849-852
    • /
    • 2007
  • In this paper, the high gain and the broadband microstrip patch antenna, which is applicable to 5 GHz band wireless LAN, is designed in order to integrate IEEE 802.11a's detailed standards($a:5.15{\sim}5.25$, $b:5.25{\sim}5.35$, $c:5.725{\sim}5.875$ [GHz]). Designed patch antenna has settled resonance frequency by insert substance(polyurethane: ${\varepsilon}_r=6.5$) between the separated parasitic patch and radiation patch for the purpose of miniaturize. And the form (${\varepsilon}_r=1.03$) were to fix the separated radiation patch and ground plans by air. Designed frequency bandwidth(VSWR 2:1) of the antenna showed broadband characteristic of $4.9[GHz]{\sim}6.1[GHz]$ to about 1.2[GHz]. Also the E-plan and H-plan profit 12[dBi] above, the 3[dB] beamwidth showed the characteristic over the E-plan $30^{\circ}$ and H-plan $60^{\circ}$ to be improved.

  • PDF

Preparation and Properties of Bio-inspired Waterborne Polyurethanes Containing Different Amount of Paraffin Wax

  • Kim, Hye-Lin;Kim, Ae-Li;Lee, Young-Hee;Kim, Sung Yeol;Park, Cha-Cheol;Rahman, Mohammad Mizanur;Kim, Han-Do
    • Textile Coloration and Finishing
    • /
    • v.30 no.1
    • /
    • pp.9-19
    • /
    • 2018
  • To prepare bio-inspired antifouling coating materials having similar structure with lotus, self-crosslinkable waterborne polyurethanes emulsions containing paraffin wax (CWPU/P0, 0.25, 0.5, 1.0, 1.5, 2.0, the number indicated the wt% of wax) were prepared by an emulsifier-free/solvent free prepolymer mixing process. The as-polymerized CWPU/P emulsions containing 0 - 1.00wt% of paraffin wax were found to be stable after 4 months, however, CWPU/P emulsions containing 1.50 and 2.00wt% of paraffin wax were unstable within 1 month storage. Considering the stability of emulsions, the optimum paraffin wax content was found to be about 1wt% to obtain stable antifouling coating emulsion material. The surface topology of CWPU/P film samples was characterized by atomic force microscopy (AFM). This study examined the effect of paraffin wax content on the surface roughness, water contact angle/surface energy, water swelling, light transmittance and tensile properties of CWPU/P film samples.

Capsular Contracture after Breast Augmentation: An Update for Clinical Practice

  • Headon, Hannah;Kasem, Adbul;Mokbel, Kefah
    • Archives of Plastic Surgery
    • /
    • v.42 no.5
    • /
    • pp.532-543
    • /
    • 2015
  • Capsular contracture is the most common complication following implant based breast surgery and is one of the most common reasons for reoperation. Therefore, it is important to try and understand why this happens, and what can be done to reduce its incidence. A literature search using the MEDLINE database was conducted including search terms 'capsular contracture breast augmentation', 'capsular contracture pathogenesis', 'capsular contracture incidence', and 'capsular contracture management', which yielded 82 results which met inclusion criteria. Capsular contracture is caused by an excessive fibrotic reaction to a foreign body (the implant) and has an overall incidence of 10.6%. Risk factors that were identified included the use of smooth (vs. textured) implants, a subglandular (vs. submuscular) placement, use of a silicone (vs. saline) filled implant and previous radiotherapy to the breast. The standard management of capsular contracture is surgical via a capsulectomy or capsulotomy. Medical treatment using the off-label leukotriene receptor antagonist Zafirlukast has been reported to reduce severity and help prevent capsular contracture from forming, as has the use of acellular dermal matrices, botox and neopocket formation. However, nearly all therapeutic approaches are associated with a significant rate of recurrence. Capsular contracture is a multifactorial fibrotic process the precise cause of which is still unknown. The incidence of contracture developing is lower with the use of textured implants, submuscular placement and the use of polyurethane coated implants. Symptomatic capsular contracture is usually managed surgically, however recent research has focussed on preventing capsular contracture from occurring, or treating it with autologous fat transfer.

Comparison Study of the Use of Absorbable and Nonabsorbable Materials as Internal Splints after Closed Reduction for Nasal Bone Fracture

  • Yi, Chang Ryul;Kim, Young Joon;Kim, Hoon;Nam, Sang Hyun;Choi, Young Woong
    • Archives of Plastic Surgery
    • /
    • v.41 no.4
    • /
    • pp.350-354
    • /
    • 2014
  • Background The authors sought to compare the use of the nonabsorbable polyvinyl alcohol sponge (PVA, Merocel) and absorbable synthetic polyurethane foam (SPF, Nasopore Forte plus) as intranasal splints after closed reduction of fractured nasal bones during the hospitalization period. Methods The medical records of 111 patients who underwent closed reduction for nasal bone fracture at Sanggye Paik Hospital, Inje University College of Medicine, from 2012 to 2013 were reviewed retrospectively. PVA (group A) or SPF (group B) was packed as an internal splint after closed reduction. The efficacy of the materials was compared and statistically analyzed. Results PVA was used in 82 patients, and SPF was used in 29 patients. The patients in group B complained significantly more of nasal pain on the first day after operation than the patients in group A. Headaches on the operation day were significantly more painful in group B than in group A. Bleeding on the fourth postoperative day was significantly reduced in group B as compared to group A. The patients in group B exhibited significantly more intensive nasal obstruction on the operation day and the following day than the patients in group A. However, on the third and fourth postoperative days, the nasal obstruction in group B was less than that in group A. The pain and bleeding related to the packing material was significantly reduced in group B as compared to group A. Conclusions The use of SPF as an absorbable packing material is a reasonable substitute for the traditional nonabsorbable material.

Animal Experiment and Blood Biocompatibility Study of Polymer Valve (고분자판막의 동물실험 및 생체내 혈액적합성 연구)

  • 김상현;홍유선
    • Journal of Chest Surgery
    • /
    • v.30 no.4
    • /
    • pp.357-362
    • /
    • 1997
  • In vivo testings of the monoleaflet polymer valve were performed in seven dogs to prove its blood biocompatibility. The monoleaflet polymer valve used in this study was developed for short-term usage n the ventricular assist device. The frame and leaflet of the polymer valve were made of polyurethane. The inter-aortic valved conduit were implanted in four dogs and the ventriculo-atrial valved conduit was implanted in one dog. The ventricular assist devices with polymer valve were implanted in two dogs. The longest survival was 20 days. Main causes of death were bleeding and infection. To examine the blood compatibility, each blood sample was collected and RBC, WBC, hematocrit, hemoglobin, platelet and lactic acid dehydrogenase were analyzed. These studies thus far demonstrated that, with further development, a reliable and inexpensive polymer valve will be used in the ventricular assist device as short term usage.

  • PDF

A Study on the Development of Dance Sportswear with Cool-touch Function (냉감 기능성 댄스스포츠 웨어 개발에 관한 연구)

  • Jun, Mi-Hwa;Jang, Jeong-Ah;Koo, Young-Seok
    • Fashion & Textile Research Journal
    • /
    • v.22 no.1
    • /
    • pp.66-75
    • /
    • 2020
  • This study helps develop cool-touch functional dance sportswear. We suggest a draft design for dance sportswear that chooses appropriate cool-touch functional materials based on an investigation of the changes of body surface temperature before and after exercise, the physical properties of cool-touch materials on the market, and the preference for cooling tools. The results are as follows. First, cool-touch functional sportswear products on the market utilize materials such as PCM, Delta fabric, high gauge fabric, and ice chips as well as incorporate functions such as UV block and eyelets for enhanced breathability. Polyester and polyurethane fibers are mainly used for cool-touch functional sportswear. Second, the neck area showed the highest surface temperatures (32.7℃ and 32.1℃) before and after exercise. Body surface temperatures measured after exercise were also lower than temperatures measured before exercise when wearing dance sportswear. Third, as for the physical properties of cool-touch materials, material 1 showed amaximum drying speed (130 min), material 3 the best moisture absorption speed (122 × 132 min), and material 4 the best thermal conductivity (0.013 7 w/m·K). Fourth, a draft design for a cool-touch functional dance sportswear was suggested, including a neckband made of removable soft PVC material on the neck area and applying material 4 in F1, B4, S2 and lower arm areas and material 1 in the armpit area. Deodorant tape was also attached to the armpit area for added comfort and antibacterial deodorant effect.

Negative Pressure Wound Therapy of Chronically Infected Wounds Using 1% Acetic Acid Irrigation

  • Jeong, Hii Sun;Lee, Byeong Ho;Lee, Hye Kyung;Kim, Hyoung Suk;Moon, Min Seon;Suh, In Suck
    • Archives of Plastic Surgery
    • /
    • v.42 no.1
    • /
    • pp.59-67
    • /
    • 2015
  • Background Negative-pressure wound therapy (NPWT) induces angiogenesis and collagen synthesis to promote tissue healing. Although acetic acid soaks normalize alkali wound conditions to raise tissue oxygen saturation and deconstruct the biofilms of chronic wounds, frequent dressing changes are required. Methods Combined use of NPWT and acetic acid irrigation was assessed in the treatment of chronic wounds, instilling acetic acid solution (1%) beneath polyurethane membranes twice daily for three weeks under continuous pressure (125 mm Hg). Clinical photographs, pH levels, cultures, and debrided fragments of wounds were obtained pre- and posttreatment. Tissue immunostaining (CD31, Ki-67, and CD45) and reverse transcription-polymerase chain reaction (vascular endothelial growth factor [VEGF], vascular endothelial growth factor receptor [VEGFR]; procollagen; hypoxia-inducible factor 1 alpha [HIF-1-alpha]; matrix metalloproteinase [MMP]-1,-3,-9; and tissue inhibitor of metalloproteinase [TIMP]) were also performed. Results Wound sizes tended to diminish with the combined therapy, accompanied by drops in wound pH (weakly acidic or neutral) and less evidence of infection. CD31 and Ki-67 immunostaining increased (P<0.05) post-treatment, as did the levels of VEGFR, procollagen, and MMP-1 (P<0.05), whereas the VEGF, HIF-1-alpha, and MMP-9/TIMP levels declined (P<0.05). Conclusions By combining acetic acid irrigation with negative-pressure dressings, both the pH and the size of chronic wounds can be reduced and infections be controlled. This approach may enhance angiogenesis and collagen synthesis in wounds, restoring the extracellular matrix.

The Textiles and the Performance Level in Developing the Pesticide Proof Clothing (기능성 농약방제복 개발을 위한 소재 및 성능에 관한 연구)

  • Hwang, Kyoung-Sook;Kim, Kyung-Ran;Lee, Kyung-Suk;Kim, Hyo-Cher;Kim, Kyung-Su;Baek, Yoon-Jeong
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.11
    • /
    • pp.1611-1620
    • /
    • 2007
  • The precaution to spray with agricultural chemicals is very important, in particular personal protective equipment against pesticide in order to protect farmers# pesticide poisoning. The Ministry of Agriculture and Forestry has proclaimed the announcement of pesticide proof clothing(PPC) in 1983, and revised it in 1987. The announcement had many performance items to achieve the high-quality protective clothing for pesticide including weight, density, force strength, dimensional change(in washing and drying), fastness(dyeing, washing, sweating and rubbing) and water resistance of clothes. Announcement of the PPC has better durability and penetration resistance function than former days, but the plenty of farmers didn#t wear it because of the intolerable heat. To increase wearing rates, the pesticide proof clothing must be estimated the water-vapour resistance. From the results, the developed PPC with polyester treated water-repellent showed the more excellent comfort than an existing PPC with nylon coated polyurethane. But the developed PPC appeared to have the low water-vapour resistance. Therefore, it is suggested that the property of pesticide penetration must be evaluated through the field test in the future study.

Preparation and Properties of Glass Fiber-Reinforced Poly(olefin ketone) Composites (유리섬유 강화 폴리올레핀케톤 복합재료의 제조 및 특성에 대한 연구)

  • Cho, Hae-Souk;Chung, Jae-Seung;Baek, Seung-Jo;Choi, Won Jae;Kim, Jin-joo;Yoon, Sung Kyun;Lee, Jong-Chan
    • Applied Chemistry for Engineering
    • /
    • v.23 no.3
    • /
    • pp.339-343
    • /
    • 2012
  • Poly(olefin ketone) terpolymer having excellent mechanical properties was synthesized and composite materials of poly(olefin ketone) containing polyurethane/amino silane functionalized glass fibers were prepared. The compatibilities between the functionalized glass fiber and the polymer were characterized by observing the fracture surfaces of the composites using scanning electron microscopy (SEM). Mechanical properties of composites with different contents, diameters, lengths, and binders of glass fibers were also studied using universal testing machine (UTM). The introduction of suitably functionalized glass fiber into the poly(olefin ketone) produces composite materials having excellent mechanical properties and they are very promising alternative materials for the engineering plastic applications.

Large Eddy Simulation of Fire and Smoke Control in a Compartment with Large Openings (큰 개구부가 있는 공간의 화재와 제연의 대와류모사)

  • 박외철
    • Fire Science and Engineering
    • /
    • v.17 no.3
    • /
    • pp.7-12
    • /
    • 2003
  • A 50 kW polyurethane fire in a compartment of 4 m ${\times}$ 1 m ${\times}$ 1.5m with large openings similar to a subway station was simulated by a large eddy simulation to investigate the fire and smoke control. The NIST FDS, which employed a mixture fraction combustion model and a finite volume method for radiation, was utilized. Distribution of temperature and smoke particles was compared with in the lower and upper corridors for three different smoke control systems, ventilation, purge, and extraction, starting in 5 sec from the ignition of the fire. For the given geometries, the ventilation system showed the best smoke removal rate and lowest temperature distribution in the both corridors. It was confirmed that the purge system is not recommended for a subway station since the smoke removal rate of the purge system was worse than that without a smoke control system.