• Title/Summary/Keyword: Polypropylene solution

검색결과 97건 처리시간 0.018초

방전처리에 의한 Polypropylene섬유의 표면개질 (Surface Modification of Polypropylene Fiber by Plasma Discharge)

  • 허만우;이창재;강인규;한명호;김삼수;임학상
    • 한국염색가공학회지
    • /
    • 제11권2호
    • /
    • pp.27-37
    • /
    • 1999
  • Polypropylene(PP) films were treated with plasma glow discharge to produce peroxy radicals on the surfaces. The peroxy radicals formed on the PP film surfaces were subsequently used for the graft polymerization of acrylic acid and acrylamide in an aqueous solution by heating, respectively. Introduction of acrylic acid and acrylamide on the PP film could be confirmed by the observation of carbonyl and primary amine absorptions based on carboxylic acid and amide, respectively. And introduction of functional group could be confirmed by weight analysis and ESCA. The water contact angle(90$^{\circ}$) of PP film was constant, irrespective of elapsed time, while plasma-treated and functional monomer-grafted PP films were slowly increased with elapsed time, showing the rearrangement of surface polar groups in air condition. The water contact angle$(90^\circ)$ of PP film was decreased by the plasma treatment$(56^\circ)$ and further decreased by the grafting of acrylic acid$(34^\circ)$ and acrylamide$(37^\circ)$, indicating increased hydrophilicity of the modified surfaces. The water contact angle of plasma-treated PP film increased a little as time elapsing. The half-life periods of surface voltage on acrylic acid-(31sec) and acrylamide-grafted PP(42sec) were significantly decreased when compared to those on PP(950sec) and plasma-treated PP film(241sec). In the experiments using acid, basic and disperse dyes, absorbance and $\Delta{E}$ values of functional monomer-grafted PP films were significantly increased than that of oxygen plasma-treated one.

  • PDF

Design and stress analysis of femur bone implant with composite plates

  • Ramakrishna, S.;Pavani, B.
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • 제5권1호
    • /
    • pp.37-50
    • /
    • 2020
  • Development of lightweight implant plates are important to reduce the stress shielding effect for a prosthesis of femur bone fractures. Stainless steel (SS-316L) is a widely used material for making implants. Stress shielding effect and other issues arise due to the difference in mechanical properties of stainless steel when compared with bone. To overcome these issues, composite materials seem to be a better alternative solution. The comparison is made between two biocompatible composite materials, namely Ti-hydroxyapatite and Ti-polypropylene. "Titanium (Ti)" is fiber material while "hydroxyapatite" and "polypropylene" are matrix materials. These two composites have Young's modulus closer to the bone than stainless steel. Besides the variety of bones, present paper constrained to femur bone analysis only. Being heaviest and longest, the femur is the most likely to fail among all bone failures in human. Modelling of the femur bone, screws, implant and assembly was carried out using CATIA and static analysis was carried out using ANSYS. The femur bone assembly was analyzed for forces during daily activities. Ti-hydroxyapatite and Ti-polypropylene composite implants induced more stress in composite implant plate, results less stress induced in bone leading to a reduction in shielding effect than stainless steel implant plate thus ensuring safety and quick healing for the patient.

Compatibility of Diazepam with Polypropylene Multilayer Infusion Container

  • Noh, Dong-Il;Park, Kyu-Nam;Chun, Heung-Jae;Park, Chong-Won;Jang, Ju-Woong;Ahn, Yun-Gyong
    • Macromolecular Research
    • /
    • 제17권7호
    • /
    • pp.516-521
    • /
    • 2009
  • Techflex$^{(R)}$, a polypropylene-lined, multilayer infusion bag, was studied for its compatibility with diazepam, in comparison to the conventional infusion bag, Safeflex$^{(R)}$, which is comprised of poly(vinyl chloride) (PVC). Diazepam was diluted in 0.9% sodium chloride isotonic solution and stored in the infusion bags for 24 h. To evaluate the sorption of diazepam into the infusion bags during storage, the concentration of the drug remaining in the bag was measured using gas chromatography-mass spectroscopy. The PVC bags exhibited a marked sorption of diazepam, with a drug loss reaching up to 90% of the initial concentration after 24 h of contact, whereas Techflex$^{(R)}$ inhibited the drug sorption, showing approximately 10%, under the same conditions. The differences in the sorption behaviors of the bags are discussed in terms of solubility parameters and crystallinities of the polymers.

표면처리된 PET 섬유와 PP 복합재료에 관한 연구 (A Study on Polypropylene and Surface Modified PET Fiber Composites)

  • 함문석;김창현;류주환
    • 폴리머
    • /
    • 제32권1호
    • /
    • pp.7-12
    • /
    • 2008
  • 폴리(에틸렌 테레프탈레이트) (PET) 섬유는 폴리프로필렌(PP)에 비해 높은 기계적 물성과 용융온도를 갖고있어 폴리프로필렌의 기계적 물성을 향상시키기 위한 섬유강화재료로 사용이 가능함을 확인하였다. 그러나 PP와 PET 섬유는 상용성이 부족하여 복합재료의 기계적 물성이 저하되었으며 PET 섬유의 구조적인 특성상 PP-g-MAH를 첨가하여도 효과가 부족하였다. 이러한 문제점을 해결하기 위해 NaOH 수용액으로 PET 섬유의 표면처리를 하여 PET 섬유의 표면에 친수성기를 도입하였으며 상용화제로서 PP-g-MAH를 첨가하여 기계적 물성이 우수한 PP/PET 섬유 복합재료를 제조하고 SEM과 IR의 결과와 물성의 거동을 상호 관련지었다.

Preparation of melamine-grafted graphene oxide and evaluation of its efficacy as a flame retardant additive for polypropylene

  • Monji, Parisa;Jahanmardi, Reza;Mehranpour, Milad
    • Carbon letters
    • /
    • 제27권
    • /
    • pp.81-89
    • /
    • 2018
  • The present study aimed to prepare a novel efficient flame retardant additive for polypropylene. The new flame retardant was prepared by chemical grafting of melamine to graphene oxide with the aid of thionyl chloride. Fourier-transform infrared spectroscopy and thermogravimetric analysis proved that melamine had been successfully grafted to the graphene oxide. The modified graphene oxide was incorporated into polypropylene via solution mixing followed by anti-solvent precipitatio. Homogeneous distribution as well as exfoliation of the nanoplatelets in the polymer matrix was observed using transmission electron microscopy. Thermogravimetric analysis showed a significant improvement in the thermo-oxidative stability of the polymer after incorporating 2 wt% of the modified graphene oxide. The modified graphene oxide also enhanced the limiting oxygen index of the polymer. However, the amount of improvement was not enough for the polymer to be ranked as a self-extinguishing material. Cone calorimetry showed that incorporating 2 wt% of the modified graphene oxide lowered total heat release and the average production rate of carbon monoxide during burning of the polymer by as much as 40 and 35%, respectively. Hence, it was concluded that the new flame retardant can retard burning of the polymer efficiently and profoundly reduce suffocation risk of exposure to burning polymer byproducts.

엔진커버용 폴리프로필렌/유리섬유/대나무섬유 복합체의 물리적 특성에 대한 대나무섬유의 용제 처리의 영향 (Effects of Solvent Treatment of Bamboo Fiber on Physical Properties of Polypropylene/Glass Fiber/Bamboo Fiber Composite)

  • 이수경;임성욱;신형식;우승건;박은영
    • 한국염색가공학회지
    • /
    • 제31권1호
    • /
    • pp.42-47
    • /
    • 2019
  • In this study, the effects of surface treatment of bamboo fiber on the physical properties of polypropylene(PP)/glass fiber(GF)/Bamboo fiber(BF) composite for engine cover were investigated. PP, GF and BF were fixed at 40%, 40% and 20% and the surface of bamboo fibers were treated to 0.5, 1.0 and 2.0% as an acid and alkali solution. PP/GF/BR composites using surface treated bamboo fibers were prepared and their tensile strength, bursting strength and impact strength were measured by universal testing machine(UTM). The composites with alkali treated bamboo fiber showed better mechanical properties than the acid treated composites. It was checked that the optimum alkali content was at 1.0% from the results of mechanical properties. The effect of surface treatment on the mechanical properties was confirmed by SEM images of fractured surface.

A Stable Supported Liquid membrane Composed of Polypropylene Glycol and Tributyl Phosphate for Phenol Separation from Aqueous Solution

  • Ahn, Hyo-Seong;Lee, Yong-Taek;Kim, Myung-Soo
    • Korean Membrane Journal
    • /
    • 제1권1호
    • /
    • pp.81-85
    • /
    • 1999
  • Tributyl phyosphate(TBP) polypropylene glycol 4000(PPG-4000) and the mixture of two compounds were examined as a liquid membrane in a supported liquid membrane (SLM) to separate phenol from aqueous solution.The feed concentration of phenol was varied in a broad range from 500 mg/L to 5000 mg/L and different types of liquid membrane were prepared to elucidate their effects on separation of phenol. It was found that the modified PPG 4000 with TBP and toluene diisocyanate(TDI) might be used as a proper liquid membrane because the mass transfer rate examined with this membrane was higher than that through methyl isobutyl ketone (MIBK) which has been used as a conventional solvent in a solvent extraction process. The breakthrough pressure of the SLM is defined to be the pressure difference across the membrane at which the supported liquid membrane is not kept in the pores any more. it indicates how the SLM is stable., It was found that the breakthrough pressure of the modified PPG-4000 was much higher than those of typical organic solvents.

  • PDF

합성섬유보강 콘크리트의 내구특성 (Durability of Concrete Reinforced by Polypropylene Fivers)

  • 박제선;정영화;윤경구;이주형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.449-454
    • /
    • 1999
  • Pavement concrete subjected to severe environmental condition may be vulnerable to frost attack practically where de-icing chemicals are used. This study focused on the investigation of durability characteristics of pavement concrete incorporation polypropylene fibers and application feasibility of these into the pavements of local roads and highway. A series of labortory tests were performed with main experimental variable such as fiber types, fiber contents. and type of concrete mix. The test of compressive strength was executed as primary tests, before the durability tests such as a scaling resistance were performed. De-icing salt resistance test was progressed by recycling freeze and thaw in the presence of a 4% calcium chloride solution. The deteriorated surfaces were rated by visual inspection and the loss weight were measured at every 5 cycles.

  • PDF

Determination of Toxic Elements in Polymer Materials Using Instrumental Neutron Activation Analysis

  • Park, Kwang-Won;Lee, Joung-Hae;Cho, Kyung-Haeng;Min, Hyung-Sik;Lim, Myung-Chul;Choi, Duk-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권7호
    • /
    • pp.1391-1394
    • /
    • 2008
  • Polymer materials are very difficult to decompose for the purpose of chemical analysis. Nondestructive analysis without pretreatment provides a suitable solution that will overcome this obstacle. In this study, CRM candidate samples that contained toxic elements such as As, Cd, Cr and Zn in a polypropylene (PP) were analyzed using instrumental neutron activation analysis (INAA). The analytical results were obtained from ten samples selected by random sampling at two different concentration levels (low and high). Particular attention was paid to reducing analytical errors and evaluating the associated uncertainty.

Preparation of $TiO_2$-Coated Polypropylene Beads by PCVD Process for Phenol Removal

  • Pham, Hung-Cuong;Kim, Dong-Joo;Kim, Kyo-Seon
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2009년도 추계학술대회 초록집
    • /
    • pp.185-185
    • /
    • 2009
  • Polypropylene beads (PP) coated with $TiO_2$ thin films were prepared by a rotating cylindrical plasma chemical vapor deposition (PCVD) reactor and were used to remove phenol in aqueous solution. The $TiO_2$ thin films of 416 nm thickness were coated on the PP particles uniformly. As the number of $TiO_2$-coated PP beads increases, the phenol is degraded faster, because of larger total surface area of photocatalysts for photodegradation. This study shows that a rotating cylindrical PCVD reactor can be a good method to prepare the particles coated with high-quality $TiO_2$ thin films, which can be applied to the pollutant removal by a photodegradation reaction of $TiO_2$ with high efficiency.

  • PDF