• Title/Summary/Keyword: Polymer electrolyte membrane fuel cell(PEMFC)

Search Result 282, Processing Time 0.032 seconds

A Study on the Strategy of Smart Charging System to Charge the PHEV in the House Which has a 1 kW Fuel Cell Cogeneration System (1 kW 급 가정용 연료전지 코제너레이션 시스템이 설치된 주택 내 플러그인 하이브리드 자동차의 스마트 충전전략 연구)

  • Roh, Chul-Woo;Kim, Min-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.838-843
    • /
    • 2008
  • Cause of struggling to escape from dependency of fossil fuels, the fuel cell and the Plug-in Hybrid Electric Vehicle (PHEV) draw attention in the all of the world. Especially, the Polymer Electrolyte Membrane Fuel Cell (PEMFC) systems have been anticipated for next generation's energy supplying system, and we can predict the PHEV will enlarge the market share in the next few years to reduce not only the air pollution in the metropolis but the fuel-expenses of commuters. This paper presents simulation results about the strategy of smart charging system for PHEV in the residential house which has 1 kW PEMFC cogeneration system. The smart charging system has a function of recommending the best time to charge the battery of PHEV by the lowest energy cost. The simulated energy cost for charging the battery based on the electricity demand data pattern in the house. The house which floor area is $132\;m^2$ (40 pyeong.). In these conditions, the annual gasoline, electricity, and total energy cost to fuel the PHEV versus Conventional Vehicle (CV) have been simulated in terms of cars' average life span in Korea.

  • PDF

Characterization of PVdF/Laponite Reinforced Composite Membranes for PEMFC Surpport (PEMFC 지지체용 PVdF/Laponite 강화 복합막의 특성평가)

  • Oh, Seul-Gi;Hwang, Hae-Young;Kim, Hyoung-Juhn;Nam, Sang-Yong
    • Membrane Journal
    • /
    • v.20 no.2
    • /
    • pp.159-168
    • /
    • 2010
  • In this study, high porous PVdF flat sheet membranes were prepared to obtain reinforced membrane support for polymer electrolyte membrane fuel cell. Nano-size laponite was randomly dispersed in the membranes to improve mechanical property which lowered by the high porosity. The morphology and porosity of prepared PVdF/Laponite composite membranes were examined using the SEM analysis and the weight method and all membranes showed over 60% porosity. The membrane thermal stability depending on the laponite contents in the composite membranes was evaluated by membrane heat shrinkage at $105^{\circ}C$ and $135^{\circ}C$. MD and TD heat shrinkage of the PVdF composite membrane containing 5 wt% laponite was 2~3% and 2~3.5% at $135^{\circ}C$, respectively. The mechanical strength was enhanced after incorporating laponite particles and 30% increase in the modulus compared to pure PVdF membrane was obtained.

Effect of Porous Flow Field on PEMFC Performance with Dead Ended Anode System (Dead ended anode 시스템에서 다공성 유로가 연료전지 성능에 미치는 영향)

  • Kim, Junseob;Kim, Junbom
    • Applied Chemistry for Engineering
    • /
    • v.33 no.6
    • /
    • pp.646-652
    • /
    • 2022
  • The dead-end anode (DEA) system is a method that closes the anode outlet and supplies fuel by pressure. The DEA method could improve fuel usage and power efficiency through system simplification. However, flooding occurs due to water and nitrogen back diffusion from the cathode to the anode during the DEA operation. Flooding is a cause of decreased fuel cell performance and electrode degradation. Therefore, tthe structure and components of polymer electrolyte membrane fuel cell (PEMFC) should be optimized to prevent anode flooding during DEA operation. In this study, the effect of a porous flow field with metal foam on fuel cell performance and fuel efficiency improvement was investigated in the DEA system. As a result, fuel cell performance and purge interval were improved by effective water management with a porous flow field at the cathode, and it was confirmed that cathode flow field structure affects water back-diffusion. On the other hand, the effect of the porous flow field at the anode on fuel cell performance was insignificant. Purge interval was affected by metal foam properties and shown stable performance with large cell size metal foam in the DEA system.

Improved Reduction of Carbon Monoxide by Highly Efficient Catalytic Shift for Fuel Cell Applications

  • Youn, M.J.;Chun, Y.N.
    • Environmental Engineering Research
    • /
    • v.13 no.4
    • /
    • pp.192-196
    • /
    • 2008
  • The generation of high purity hydrogen from reformed hydrocarbon fuels, or syngas, is essential for efficient operation of the fuel cell (PEMFC, Polymer Electrolyte Membrane Fuel Cell). Usually, major components of reformed gas are $H_2$, CO, $CO_2$ and $H_2O$. Especially a major component, CO poisons the electrode of fuel cells. The water gas shifter (WGS) that shifts CO to $CO_2$ and simultaneously produces $H_2$, was developed to a two stage catalytic conversion process involving a high temperature shifter (HTS) and a low temperature shifter (LTS). Also, experiments were carried out to reduce the carbon monoxide up to $3{\sim}4%$ in the HTS and lower than 5,000 ppm via the LTS.

Humidification Characterization of water-to-gas Membrane Humidifier for Polymer Electrolyte Membrane Fuel Cell (고분자 전해질 연료전지용 water-to-gas 막 가습기의 투과 특성)

  • Chang, Dae-Kwon;Lee, Yong-Taek
    • Membrane Journal
    • /
    • v.20 no.4
    • /
    • pp.326-334
    • /
    • 2010
  • In this study, characterization and performance of membrane humidifier using membrane distillation was evaluated for moisture of fuel gas in the PEMFC. The data were expressed dew point. The best results show $51.19^{\circ}C$ at $60^{\circ}C$ of water temperature, $54.22^{\circ}C$ at 900 mL/min and $60.03^{\circ}C$ at 100 strands. The mass transfer modelling of membrane humidifier were able to predict humidification of fuel gases for operating PEMFC. When the membrane humidifier was applied to the 100 W stack, it showed stable voltage and power. The volume of membrane humidifier was small however, showed better performance than bubble humidifier.

Experimental Evaluation of Hydrophilic Membrane Humidifier with Isolation of Heat Transfer Effect (친수성 막을 통한 수분 전달 특성 연구)

  • Tak, Hyun Woo;Kim, Kyoung Teck;Han, Jae Young;Im, Seok Yeon;Yu, Sang Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.9
    • /
    • pp.815-821
    • /
    • 2013
  • The efficiency and lifetime of a polymer electrolyte membrane fuel cell (PEMFC) system is critically affected by the humidity of the incoming gas, which should be maintained properly under normal operating conditions. Typically, the incoming gas of a fuel cell is humidified by an external humidifier, but few studies have reported on the device characteristics. In this study, a laboratory-scale planar membrane humidifier is designed to investigate the characteristics of water transport through a hydrophilic membrane. The planar membrane humidifier is immersed in a constant temperature bath to isolate the humidifier from the effect of temperature variations. The mass transfer capability of the hydrophilic membrane is first examined under isothermal conditions. Then, the mass transfer capability is investigated under various conditions. The results show that water transport in the hydrophilic membrane is significantly affected by the flow rate, operating temperature, operating pressure, and flow arrangement.

Corrosion Characteristics of 316L Stainless Steel with Chloride Concentrations in Cathode Operating Conditions of Metallic Bipolar Plate for PEMFC (고분자 전해질 연료전지 금속분리판용 316L 스테인리스강의 양극작동조건에서 염화물 농도에 따른 부식 특성)

  • Shin, Dong-Ho;Kim, Seong-Jong
    • Corrosion Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.435-450
    • /
    • 2021
  • The interest in eco-friendly energy is increasing, and polymer electrolyte membrane fuel cell (PEMFC) is attracting attention as alternative power sources. Research on metallic bipolar plates, a fuel cell component, is being actively conducted. However, since the operating conditions of PEMFC, in which sulfuric acid (H2SO4) and hydrofluoric acid (HF) are mixed, are strong acidity, the durability of the metallic bipolar plate is very important. In this research, the electrochemical characteristics and corrosion damage behavior of 316L stainless steel, a material for metallic bipolar plates, were analyzed through potentiostatic corrosion tests with test times and chloride concentrations. As the test times and chloride concentrations increased, the current density and corrosion damage increased. As a result of observation with scanning electron microscope(SEM) and 3D microscope, both the depth and width of pitting corrosion increased with increases in test times and chloride concentrations. In particular, the pitting corrosion damage depth at test conditions of 6 hours and 1000 ppm chloride increased the most. The growth of the pitting corrosion damage was not directly proportional to time and increased significantly after a certain period.

Decal Method with High Catalyst Transfer Ratio and Its Performance in PEMFC

  • Park, Hyun-Seo;Cho, Yong-Hun;Cho, Yoon-Hwan;Sung, Yung-Eun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.169-171
    • /
    • 2007
  • A breaking layer was introduced to conventional decal transfer method in membrane electrolyte assembly fabrication for high catalyst transfer ratio. In this study, the modified decal transfer method with high catalyst transfer ratio was introduced and its performance is studied. The structural features of electrodes made by decal method were investigated using scanning electron microscopy and current-voltage polarization measurement.

  • PDF

Research on Improving in Mass Transfer Characteristics by Cathode Wave-Form Channel (Wave 형상 채널을 통한 연료전지 Cathode에서의 물질전달 특성 향상에 관한 연구)

  • Lee, Kyu-Ho;Nam, Ki-Hoon;Byun, Jae-Ki;Choi, Nam-Hyun;Choi, Young-Don
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.1
    • /
    • pp.69-76
    • /
    • 2011
  • PEMFC (polymer electrolyte membrane fuel cell) is device that generates electricity from hydrogen. It is one of the subjects related to renewable energy and various research has been conducted on the PEMFC. PEMFC has low operating temperature and high efficiency among fuel cells, and is given attention as means for automobile and domestic use. Analysis of flow field pattern in supplying hydrogen and oxygen is part of the research to increase PEMFC efficiency. In this study, separation plate currently used in PEMFC is transformed to wave shape and mass transfer characteristics in the channel is examined through numerical and experimental analysis. Wave shape separation plate yielded 18% increase of efficiency compared to separation plate used in normal channel. And improvements in mass transfer characteristics were verified.