• Title/Summary/Keyword: Polymer electrolyte membrane Fuel cell

Search Result 467, Processing Time 0.028 seconds

Analysis for Performance Deviation of Individual Cells in a Multi-Cell Test System for Rapid-Screening of Electrode Materials in PEMFCs (고분자전해질 연료전지용 전극물질의 빠른 스크리닝을 위한 멀티셀 테스트 시스템에서 개별셀의 성능편차에 대한 분석)

  • Zhang, Yan;Lee, Ji-Jung;Park, Gyung-Se;Lee, Hong-Ki;Shim, Joong-Pyo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.6
    • /
    • pp.842-851
    • /
    • 2011
  • A multi-cell test system with 25 independent cells is used to test different electrode materials simultaneously for polymer electrolyte membrane fuel cells (PEMFCs). Twenty-five segmented membrane electrode assemblies (MEAs) having the same or different Pt-loading are prepared to analyze the performance deviation of cells in the multi-cell test system. Improvements in the multi-cell test system are made by ensuring that the system performs voltage sensing for the cells individually and inserting optimum gaskets between the MEAs and the graphite plates. The cell performances are improved and their deviations are significantly decreased by these modifications. The performance deviations changed according to various cell configurations because the operating conditions of the cells, such as the gas flow and concentration, differed. This cell system can be used to test multiple electrodes simultaneously because it shows relatively uniform performance under the same conditions as well as linear correlation with various catalyst loadings.

Electrospun Poly(Ether Sulfone) Membranes Impregnated with Nafion for High-Temperature Polymer Electrolyte Membrane Fuel Cells

  • Lee, Hong Yeon;Hwang, Hyung Kwon;Lee, Jin Goo;Jeon, Yukwon;Park, Dae-Hwan;Kim, Jong Hak;Shul, Yong-Gun
    • Journal of the Korean Electrochemical Society
    • /
    • v.19 no.1
    • /
    • pp.9-13
    • /
    • 2016
  • Electrospun poly(ether sulfone) (PES) membrane impregnated with Nafion (PES-N) have been developed for high-temperature polymer-electrolyte membrane fuel cell (HT-PEMFC). The PES-N obtains highly thermal stability up to $430^{\circ}C$, which is higher than that of the commercial Nafion 212. The PES-N membrane shows a good proton conductivity of about $10^{-2}S\;cm^{-1}$ in a temperature range from $75^{\circ}C$ to $120^{\circ}C$. The membrane-electrode assembly (MEA) with the PES-N membrane exhibits a current density of $1.697A\;cm^{-2}$ at $75^{\circ}C$, and $0.813A\;cm^{-2}$ at $110^{\circ}C$ when the applied voltage is 0.6 V, whereas the MEA with the Nafion 212 membrane shows the current density of $0.647Acm^{-2}$ at $110^{\circ}C$. The results suggest that the PES-N can be a good candidate for a polymer electrolyte membrane of the HT-PEMFC.

Hydrocarbon-Organic Composite Membranes for Improved Oxidative Stability for PEMFC Applications (연료전지용 탄화수소 전해질 막의 산화안정성 향상을 위한 유기물 복합막의 제조 및 특성 분석)

  • Park, Satbyul;Lee, Hyejin;Bae, Byungchan
    • Journal of the Korean Electrochemical Society
    • /
    • v.19 no.2
    • /
    • pp.45-49
    • /
    • 2016
  • In order to mitigate oxidative degradation of polymer membrane during fuel cell operation, an organic radical quencher was introduced. Rutin was selected as a radical quencher and mixed with sulfonated poly(arylene ether sulfone) to prepare composite membrane. Physicochemical properties of the composite membranes such as water uptake and proton conductivity were characterized. Hydrogen peroxide exposure experiment, which can mimic accelerated oxidative stability test during fuel cell operation, was adopted to evaluate the oxidative stability of the membranes. The composite membranes containing Rutin showed similar proton conductivity and enhanced oxidative stability compared to pristine ones.

Resistance Analysis by Distribution of Relaxation Time According to Gas Diffusion Layers and Binder Amounts for Cathode of High-temperature Polymer Electrolyte Membrane Fuel Cell (고온 고분자 막 전해질 연료전지 캐소드의 가스 확산층 및 바인더 함량에 따른 완화 시간 분포(DRT) 저항 분석)

  • DONG HEE KIM;HYOEN SEUNG JUNG;CHANHO PAK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.3
    • /
    • pp.283-291
    • /
    • 2023
  • The physical properties were analyzed for four gas diffusion layers, and gas diffusion electrodes (GDEs) for the cathode of high-temperature polymer electrolyte membrane fuel cell were fabricated through bar coating with three binder to carbon (B/C) ratios. Among them, The GDE from JNT30-A6P showed a significant change in secondary pore volume at a B/C ratio of 0.31, which had the largest pore volume among all GDEs. In the polarization curve, JNT30-A6P GDE showed the best membrane electrode assembly (MEA) performance with a peak power density of 384 mW/cm2 at a a B/C ratio of 0.31. From the distribution of relaxation time analysis, the peak 1 corresponding to mass transfer resistance of oxygen reduction reaction (ORR) was significantly reduced in the JNT30-A6P GDE. This is the result that when the binder content decreased, the volume of the secondary pore increased, and the mass transfer resistance of ORR decreased, which played an essential role in the MEA performance.

Characterization of Carbon Composite Bipolar Plates far Polymer Electrolyte Membrane Fuel Cells (고분자 전해질 연료전지용 탄소 복합체 Bipolar Plates의 기체 투과 특성 연구)

  • Hong Seong Uk;Kim Hyun Seon;Choi Won Seok;Kim Jeong Heon
    • Membrane Journal
    • /
    • v.15 no.2
    • /
    • pp.141-146
    • /
    • 2005
  • In this study, carbon composites were prepared using carbon graphite, thermoset resin, and carbon black. Oxygen permeability was measured using the continuous flow gas permeation analyzer as a function of composition and processing conditions. The experimental results showed that the oxygen permeability increased as the carbon black content increased, whereas the oxygen permeability decreased as the pressing time increased. The oxygen permeability was not affected by the processing pressure.

Prediction of Chemical Acceleration Durability Time of Polymer Membrane in Polymer Electrolyte Membrane Fuel Cells (고분자 전해질 연료전지에서 고분자막의 화학적 가속 내구 시간 예측)

  • Sohyeong Oh;Donggeun Yoo;Sunggi Jung;Jihong Jeong;Kwonpil Park
    • Korean Chemical Engineering Research
    • /
    • v.61 no.1
    • /
    • pp.26-31
    • /
    • 2023
  • For durability improvement of polymer electrolyte membrane fuel cell (PEMFC) polymer membrane, accelerated durability evaluation methods that can evaluate durability in a short time have been researched and developed. However, the lifespan of fuel cells for large commercial vehicles such as trucks and buses is more than three times that of passenger cars, and the chemical accelerated stress test (AST) time is also longer, reaching 1,500 hours or more. Therefore, in this study, as a method to evaluate the chemical durability of a membrane within a short time, it was examined whether the durability could be predicted by the pristine membrane characteristics. Hydrogen crossover current density (HCCD) and short resistance (SR) were estimated as initial characteristics, and AST time was predicted through the Fenton experiment, which was possible as an out-of-cell experiment for 3 hours. As the HCCD and fluoride ion emission concentration increased, the AST time tended to be linearly shortened, but there was a deviation (R2 ≒0.65). When the SR decreased, the AST time showed a linear increase, and the accuracy was high (R2 =0.93), so the AST time could be predicted with the initial SR of the membrane.

Studies on the characteristics of the catalyst layer of the PEMFC Electrode (고분자전해질막 연료전지의 촉매층 특성에 대한 연구)

  • Sridhar Parthasarathi;Ihm Jae Wook;Yu Hyung Kyun;Ryu Hojin
    • 한국전기화학회:학술대회논문집
    • /
    • 2002.07a
    • /
    • pp.129-134
    • /
    • 2002
  • The present paper highlights on the need to understand the correlation of the characteristics of the catalyst layer with the performance of the polymer electrolyte membrane fuel cell. The paper deals with the correlation of the platinum loading in the catalyst layer and the performance of the Polymer Electrolyte Membrane Fuel Cell(PEMFC) and also the correlation of the required hydrophiliticityihydrophobicity in the catalyst layer to get the optimum performance under given operating conditions.

  • PDF

Non-Pt transition metal electrode catalyst for Oxygen Reuction Reaction of Polymer Electrolyte Membrane Fuel Cell (고분자 전해질 연료전지의 산소환원반응을 위한 비백금계 전이금속 전극 촉매)

  • Kim, Jy-Yeon;Lee, Sang-Beom;Park, Kyung-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.383-385
    • /
    • 2009
  • 비백금계 코발트 전이금속 촉매를 탄소지지체에 담지한 뒤, 암모니아 분위기에서 $500^{\circ}C$에서 3시간 동안 열처리하는 과정을 통해 코발트 질화물 촉매를 제조했다. 제조된 촉매들의 구조와 형태를 각각 XRD, HE-TEM등을 통해 분석하였고, 전위 측정기를 이용한 CV, LSV 결과로부터 촉매의 전기화학적 산소 환원특성을 분석하여, 기존의 연료전지 양극 촉매로 사용되는 고가의 백금촉매를 대체하기 위한 비백금계로서의 가능성을 확인하였다.

  • PDF

Studies on the Characteristics of the Catalyst Layer of the PEMFC Electrode (고분자전해질용 연료전지의 전극 촉매중 특성에 관한 연구)

  • Sridhar, Parthasarathi;Ihm, Jae-Wook;Yu, Hyung-Kyun;Ryu, Ho-Jin
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.1
    • /
    • pp.65-67
    • /
    • 2003
  • The present paper highlights on the need to understand the correlation of the characteristics of the catalyst layer with the performance of the polymer electrolyte membrane fuel cell (PEMFC). This paper deals with the correlation of the platinum loading in the catalyst layer and the performance of the polymer electrolyte membrane fuel cell and also the correlation of the required hydrophilicity/hydrophobicity in the catalyst layer to get the optimum performance under given operating conditions.