• Title/Summary/Keyword: Polymer electrolyte membrane

Search Result 628, Processing Time 0.027 seconds

A Study on PWM Converter/Inverter Drive System by a Fuel Cell Simulator (연료전지 Simulator에 의한 PWM 컨버터/인버터 구동시스템에 관한 연구)

  • 이태원;장수진;김진태;구자성;원충연;김창현
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.222-230
    • /
    • 2004
  • In this paper, a 3㎾ fuel cell generation system with an active fuel cell simulator has been proposed. The developed fuel cell simulator generates the actual voltage and current output characteristics of the Polymer Electrolyte Membrane Fuel Cell (PEMFC), so that the overall performance and the dynamics of the proposed system could be effectively examined and tested. In This paper, at first, the system configuration and operational principle of the developed fuel cell simulator has been investigated and the design process of the fuel cell generation system is explained in detail. In addition, the validity of the proposed system has been verified lly the informative simulation and experimental result

A Study on Performance Improvement of PEMFC Using Wire Mesh Cell Structure (Wire Mesh 적용을 통한 PEMFC 성능 향상에 관한 연구)

  • Jin, Sang-Mun;Beack, Suk-Min;Heo, Seong-Il;Yang, Yoo-Chang;Kim, Sae-Hoon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.21 no.4
    • /
    • pp.295-300
    • /
    • 2010
  • Metal bipolar plate applied to Polymer Electrolyte Membrane Fuel Cell is getting most attractive due to their good feasibility of mass production and low cost. But it is one of the immediate causes of performance decline because it is difficult to reduce channel pitch of metal bipolar plate. In this study, mesh was inserted in between bipolar plate and GDL to obtain uniform contact pressure without reducing channel pitch. The section measuring and performance test were carried out to confirm the mesh structure distributes contact pressure equally in reacting area. The performance of 3 type mesh structures developed in this study were higher than the normal cell at all over the current range. Especially, it showed that the mesh cell performance was increased and pressure drop was decreased with diminishing mesh gap size. The Mesh structure was more sensitive to humidification and contact pressure change than the normal cell.

Synthesis and Characterization of Poly(ether Sulfone)s Containing Bisphenol-TP for PEMFC (고분자 전해질 막 연료전지를 위한 Bisphenol-TP를 포함한 Poly(ether sulfone)s 고분자 막의 합성과 특성)

  • Lim, Young-Don;Seo, Dong-Wan;Lee, Soon-Ho;Islam, Monirul;Kang, Da-Lib;Kim, Whan-Gi
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.21 no.4
    • /
    • pp.307-312
    • /
    • 2010
  • Poly (ether sulfone)s with Bisphenol-TP and Bisphenol-AF were prepared with Bisphenol-TP <4,4-dihydroxy tetraphenyl methane>, 4-Fluorophenyl sulfone, and Bisphenol-AF <4,4-(hexafluoroisopropylidene) diphenol> using Potassium carbonate in Sulfolane at $210^{\circ}C$. Sulfonated PBTP-AF were obtained by reaction of Chlorosulfuric acid with copolymers. A series of copolymers were studied by $^1H$-NMR spectroscopy, Differential Scanning Calorimeter (DSC), and Thermo Gravimetric Analysis (TGA). Sorption experiments were conducted to observe the interaction of polymers with water and methanol.

Lightweight Metallic Bipolar Plates of PEMFC for a Small Reconnaissance UAV (소형 정찰 UAV를 위한 고분자 전해질막 연료전지의 경량의 금속 분리판)

  • Kim, Ki-In;Lee, Jong-Kwang;Jang, Bo-Sun;Kwon, Se-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.10
    • /
    • pp.1031-1037
    • /
    • 2010
  • This paper proposed lightweight aluminum bipolar plates as an alternative for conventional graphite bipolar plates in fuel cell systems used as a power source for small reconnaissance UAVs. Since bipolar plates occupy more than 80% of the total weight of the fuel cell system, lightweight aluminum bipolar plates can improve the overall payload and flight time of the fuel cell UAV. The aluminum and graphite bipolar plates were fabricated to compare the performance of each of them. A 15% higher performance per weight was obtained from aluminum bipolar plates than the graphite bipolar plates. Also, the performance of a single cell using aluminum bipolar plates was evaluated under various operating conditions.

The performance of PEMFC after hydrogen sulfide poisoning under various operating conditions (황화수소 피독이 고분자전해질 막 연료전지의 성능에 미치는 영향)

  • Lee, Soo;Jin, Seok-Hwan;Kim, Sang-Myoung
    • Journal of the Korean Applied Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.57-63
    • /
    • 2011
  • Polymer electrolyte membrane fuel cell (PEMFC) performance degrades when hydrogen sulfide ($H_2S$) is present in the fuel hydrogen gas; this is referred to as $H_2S$ poisoning. This paper reveals $H_2S$ poisoning on PEMFC by measuring electrical performance of single cell FC under various operating conditions. The severity of $H_2S$ poisoning depended on $H_2S$ concentration under best operating conditions($65^{\circ}C$ of cell temperature and 100% of anode humidification). $H_2S$ adsorption occured on the surface of catalyst layer on MEA, but not on the gas diffusion layer(GDL) by analyzing SEM/EDX data. In addition, MEA poisoning by $H_2S$ was cumulative but reversible. After poisoning for less than 150 min, performance of PEMFC was recovered up to 80% by just inert nitrogen gas purging.

Real-time and Power Hardware-in-the-loop Simulation of PEM Fuel Cell Stack System

  • Jung, Jee-Hoon
    • Journal of Power Electronics
    • /
    • v.11 no.2
    • /
    • pp.202-210
    • /
    • 2011
  • Polymer electrolyte membrane (PEM) fuel cell is one of the popular renewable energy sources and widely used in commercial medium power areas from portable electronic devices to electric vehicles. In addition, the increased integration of the PEM fuel cell with power electronics, dynamic loads, and control systems requires accurate electrical models and simulation methods to emulate their electrical behaviors. Advancement in parallel computation techniques, various real-time simulation tools, and smart power hardware have allowed the prototyping of novel apparatus to be investigated in a virtual system under a wide range of realistic conditions repeatedly, safely, and economically. This paper builds up advancements of optimized model constructions for a fuel cell stack system on a real-time simulator in the view points of improving dynamic model accuracy and boosting computation speed. In addition, several considerations for a power hardware-in-the-loop (PHIL) simulation are provided to electrically emulate the PEM fuel cell stack system with power facilities. The effectiveness of the proposed PHIL simulation method developed on Opal RT's RT-Lab Matlab/Simulink based real-time engineering simulator and a programmable power supply is verified using experimental results of the proposed PHIL simulation system with a Ballard Nexa fuel cell stack.

Geometrically Inhomogeneous Random Configuration Effects of Pt/C Catalysts on Catalyst Utilization in PEM Fuel Cells (연료전지 촉매층 내 촉매활성도에 대한 탄소지지 백금 촉매의 기하학적 비등방성 효과에 관한 연구)

  • Shin, Seungho;Kim, Ah-Reum;Jung, Hye-Mi;Um, Sukkee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.10
    • /
    • pp.955-965
    • /
    • 2014
  • Transport phenomena of reactant and product are directly linked to intrinsic inhomogeneous random configurations of catalyst layer (CL) that consist of ionomer, carbon-supported catalyst (Pt/C), and pores. Hence, electrochemically active surface area (ECSA) of Pt/C is dominated by geometrical morphology of mass transport path. Undoubtedly these ECSAs are key factor of total fuel cell efficiency. In this study, non-deterministic micro-scale CLs were randomly generated by Monte Carlo method and implemented with the percolation process. To ensure valid inference about Pt/C catalyst utilization, 600 samples were chosen as the number of necessary samples with 95% confidence level. Statistic results of 600 samples generated under particular condition (20vol% Pt/C, 30vol% ionomer, 50vol% pore, and 20nm particle diameter) reveal only 18.2%~81.0% of Pt/C can construct ECSAs with mean value of 53.8%. This study indicates that the catalyst utilization in fuel cell CLs cannot be identical notwithstanding the same design condition.

A Study on the Protective Function Performance Evaluation of Grid-Connected Power Conditioning System for Residential Fuel Cell System (가정용 연료전지시스템 계통연계형 전력변환장치의 보호기능 성능평가에 관한 연구)

  • Lee, Jung-Woon;Seo, Won-Seok;Kim, Young-Gyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.341-344
    • /
    • 2009
  • In this paper, protective function evaluation was conducted to determine the performance and safety of a power conditioning system(PCS) for 1kW residential fuel cell system. It is essential to have a power quality, grid-connection and safety of PCS. Even though it is under 500ms by KGS-A410 standard, it is shown a rapid response time of 25ms from input under-voltage test. In terms of output over/under-voltage test, it is shown 29.15 and 79.4ms. Especially using anti-islanding test, it is shown all times under 100ms for combination cases of real and reactive power. We confirmed a rapid response characteristics and safety of PCS. The results of this evaluation are being used to develop a new test protocols of PCS.

  • PDF

Operating characteristics of an air cooling PEMFC for portable application (이동 전원용 공랭식 고분자 연료전지의 제작 및 운전 특성 연구)

  • Sohn Young-Jun;Park Gu-Gon;Yang Tae-Hyun;Yoon Young-Gi;Lee Won-Yong;Yim Sung-Dae;Kim Chang-Soo
    • New & Renewable Energy
    • /
    • v.1 no.1 s.1
    • /
    • pp.72-78
    • /
    • 2005
  • Optimal design and proper operation are important to get aimed output power of a polymer electrolyte membrane fuel cell (PEMFC) stack. An air cooling fuel cell stack is widely used in sub kW PEMFC systems. The purpose of this study is to analyze operating conditions affecting the performance of the air cooling PEMFC which is designed for portable application. In portable applications, air cooling stack is difficult to maintain well balanced operating conditions. The importart parameters are the relative humidity, the temperature of the stack, the utilization of reactant gas and so on. in this study, a 500W air cooling PEMFC was fabricated and tested to evaluate the design performance and to determine optimal operating conditions. Moreover, basic modeling also is carried out. These results can be used 3s design criteria and optimal operating conditions for portable PEMFCs

  • PDF

Electrocatalytic activity of Carbon-supported near-surface alloys (NSAs) for Electode reaction of Fuel cell (연료전지 전극 반응을 위한 카본 담지 표면 합금의 전기촉매 활성)

  • Park, In-Su;Lee, Kug-Seung;Choi, Baeck-Beom;Sung, Yung-Eun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.316-319
    • /
    • 2006
  • There is a worldwide interest in the development and commercialization of Polymer Electrolyte Membrane Fuel Cells (PEMFCs) for vehicular and stationary applications. One of the major objectives is the reduction of loaded electrode materials, which is comprise of the Pt-based noble metals. In this paper, a novel chemical strategy is described for the preparation and characterization of carbon-supported and surface-alloys, which were prepared by using a successive reduction process. After preparing Au colloid nanoparticles, the deposition of Au colloid nanoparticles occurred spontaneously in the carbon black-dispersed aqueous solution. Then nano-scaled active materials were formed on the surface of carbon-supported Au nanoparticles. The structural and electrochemical analyses indicate that the active materials were deposited on the surface of Au nanoparticles selectively and that an at toying process occurred during the successive reducing process The carbon-supported & surface-alloys showed the higher electrocatalytic activity than those of the particle-alloys and commercial one (Johnson-Matthey) for the reaction of methanol and formic acid oxidation. The increased electrocatalytic activity might be attributed to the effective surface structure of surface-alloys, which have a high utilization of active materials for the surface reaction of electrode.

  • PDF