• 제목/요약/키워드: Polymer Sensor

검색결과 431건 처리시간 0.029초

Polymer/Metal Based Flexible MEMS Biosensors for Nerve Signal Monitoring and Sensitive Skin

  • Kim, Yong-Ho;Hwang, Eun-Soo;Kim, Yong-Jun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제5권1호
    • /
    • pp.11-16
    • /
    • 2005
  • This paper presents fabrication process and experimental results of two different types of flexible MEMS biosensors based on polymer/metal multilayer processing techniques. One type of a biosensor is a microelectrode array (MEA) for nerve signal monitoring through implanting the MEA into a living body, and another is a tactile sensor capable of being mounted on an arbitrary-shaped surface. The microelectrode array was fabricated and its electrical characteristics have been examined through in vivo and in vitro experiment. For sensitive skin, flexible tactile sensor array was fabricated and its sensitivity has been analyzed. Mechanical flexibility of these biosensors has been achieved by using a polymer, and it is verified by implanting a MEA to an animal and mounting the tactile sensor on an arbitrary-shaped surface.

초탄성 마이크로 그리퍼의 제작 및 압전폴리머 센서를 이용한 센서화 (Fabrication and Sensorization of a Superelastic Alloy Microrobot Gripper using Piezoelectric Polymer Sensors)

  • 김덕호;김병규;강현재;김상민
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.251-255
    • /
    • 2003
  • This paper presents the design, fabrication, and calibration of a piezoelectric polymer-based sensorized microgripper. Electro discharge machining technology is employed to fabricate super-elastic alloy based micro gripper. It is tested to present improvement of mechanical performance. For integration of force sensor on the micro gripper, the sensor design based on the piezoelectric polymer PVDF film and fabrication process are presented. The calibration and performance test of force sensor integrated micro gripper are experimentally carried out. The force sensor integrated micro gripper is applied to perform fine alignment tasks of micro opto-electrical components. It successfully supplies force feedback to the operator through the haptic device and plays a main role in preventing damage of assembly parts by adjusting the teaching command.

  • PDF

Polymer based adherent differential output sensor를 이용한 전자 청진 시스템 설계 (An Electronic Auscultation System Design using a Polymer Based Adherent Differential Output Sensor)

  • 한철규;고성택;최민주
    • 융합신호처리학회논문지
    • /
    • 제2권1호
    • /
    • pp.108-112
    • /
    • 2001
  • Heart sound contains rich information regarding the dynamics of the heart and the auscultation has been a first choice of routine procedures for diagnosis of the heart. However, heart sounds captured using a conventional stethoscope are not often loud or clear enough for doctors to precisely classify their characteristics, especially, under the noisy environments of the hospital. A simple auscultation device that removed shortcomings of the conventional stethoscope was constructed in the study. The device employed a polymer based adherent differential output sensor which was on contact with skin through a coupling medium and appropriated electronic circuits for signal amplification and conditioning An ordinary headphone is taken to hear the captured heart sounds and the volume can be adjusted to hear well. It is also possible that the device sends the captured heart sound signals to a PC where the signals are further processed and viualized.

  • PDF

Ionic Polymer Transducers in sensing: the streaming potential hypothesis

  • Weiland, Lisa Mauck;Akle, Barbar
    • Smart Structures and Systems
    • /
    • 제6권3호
    • /
    • pp.211-223
    • /
    • 2010
  • Accurate sensing of mechanical strains in civil structures is critical for optimizing structure reliability and lifetime. For instance, combined with intelligent control systems, electromechanical sensor output feedback has the potential to be employed for nondestructive damage evaluation. Application of Ionic Polymer Transducers (IPTs) represents a relatively new sensing approach with more than an order of magnitude higher sensitivity than traditional piezoelectric sensors. The primary reason this sensor has not been widely used to date is an inadequate understanding of the physics responsible for IPT sensing. This paper presents models and experiments defending the hypothesis of a streaming potential sensing mechanism.

Ultra-thin Film Assembly of a Novel Biomaterial Containing Protein and Functionalized Polymer for Sensor Application

  • 임정옥;손병기;허증수
    • 센서학회지
    • /
    • 제4권4호
    • /
    • pp.81-87
    • /
    • 1995
  • A novel biomaterial capable of incorporating biotinylated biomolecule has been synthesized. Our strategy is to biotinylate one-dimensional electroactive polymers and use a bridging streptavidin protein on Langmuir-Blodgett (LB) organized films. These copolymers are derivatized with long alkyl chains and biotin moieties to bind, respectively, to the hydrophobic surface and the biotinylated species, through the biotin and streptavidin complexation. We utilize the polymer assembly approach to attach a signal transducing biomolecule biotinylated phycoerythrin (B-PE) into this novel biomaterial by binding the unoccupied biotin binding sites on the bound streptavidin (4 sites total). The pressure-area isotherm of the protein injected monolayer showed area expansion. A characteristic fluorescent emission peak at 576nm was detected from the monolayer transferred onto a solid substrate. These observations demonstrated the promise of the organized thin polymer assemblies for their application to the sensor system.

  • PDF

다파장 광원을 이용한 폴리머 광도파로형 SPR 센서 (The polymer waveguide type SPR sensor using a multi-wavelength light source)

  • 박창섭;염세혁;김도억;강병호;김규진;김학린;강신원
    • 센서학회지
    • /
    • 제16권6호
    • /
    • pp.401-406
    • /
    • 2007
  • In this paper, we fabricated the polymer waveguide type surface plasmon resonance (SPR) sensor using a white light source and optical spectrum analyzer (OSA). Fabricated sensor uses the principle of phase matching between evanescent wave and surface plasmon wave. According to the measuring result, the shift of resonance wavelength conducts the change of the refractive index. The proposed SPR sensor is expected to apply the integrated multichannel SPR sensor and the realtime monitoring system.

부착형 고분자 압전센서를 이용한 탄성파 검출 연구 (A Study on Detection of Elastic Wave Using Patch Type Piezo-Polymer Sensor)

  • 김기복;윤동진;권재화;이영섭
    • 비파괴검사학회지
    • /
    • 제24권3호
    • /
    • pp.268-274
    • /
    • 2004
  • 스마트 구조물에 적합한 탄성파 검출 센서로서 고분자 압전센서를 이용한 부착형 센서에 대한 연구를 수행하였다. PVDF와 P(VDF-TrFE)에 대하여 센서로서의 특성을 평가하였으며 상용화된 PZT 센서와 비교하였다. 음향임피던스가 서로 다른 여러 가지 재료에 고분자 압전센서를 부착하여 연필심 파괴 시 발생하는 탄성파를 검출하여 분석하였다. 센서의 직경이 증가함에 따라 검출 신호의 최대 진폭 값은 증가하였으나 센서의 주파수 검출한계는 감소하는 것으로 나타났다. 시편의 음향임피던스가 감소할수록 검출신호의 최대 진폭 값은 증가하였으며 주로 저주파수의 주파수 성분의 신호에 민감한 것으로 분석되었다. 전반적으로 P(VDF-TrFE) 센서가 PVDF 센서보다 감도 면에서 다소 양호한 것으로 나타났다.

Carbon Monoxide Sensor Based on a B2HDDT-doped PEDOT:PSS Layer

  • Memarzadeh, R.;Noh, Hui-Bog;Javadpour, S.;Panahi, F.;Feizpour, A.;Shim, Yoon-Bo
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권8호
    • /
    • pp.2291-2296
    • /
    • 2013
  • An efficient carbon monoxide (CO) sensor was developed based on poly(3,4-ethylenedioxy)thiophenepoly(styrenesulfonate) (PEDOT:PSS) modified with a new pyrimidine-fused heterocyclic compound, bis(2-hydroxyphenyl)dihydropyrido[2,3-d:6,5-d]dipyrimidine-tetraone (B2HDDT). B2HDDT remains stable in the polymer matrix through interactions with functional groups of the polymer. It created prominent sites that captured CO gas, and the experimental parameters, including the amount of doped B2HDDT in the PEDOT:PSS film, were optimized. The sensor probe was also examined to verify its reliability for detecting CO in the presence of atmospheric gases in a discriminating manner. NMR, AFM, and FT-IR spectra were obtained to evaluate the structure and morphology of the B2HDDT-doped PEDOT:PSS (PEDOT:PSS/B2HDDT) film. The content of 35 vol % B2HDDT (7.0 mM) in PEDOT:PSS provided the largest response factor (${\Delta}R/R_o$) for the CO gas. The sensor response was reproducible, with a relative standard deviation < 5% (n = 5). The detection limit was determined to be $0.44{\pm}0.05$ vol %.

폴리머 마이크로머시닝 기술에 의한 폴리이미드 촉각 센서 모듈 (Polyimide-based Tactile Sensor Module by Polymer Micromachining Technology)

  • 김건년;이강열;금창욱;박정호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1524-1525
    • /
    • 2007
  • A flexible tactile sensor module based on polyimide matrix integrated with sensing elements and pluggable terminals connector was fabricated by polymer micromachining technology for robotic applications. The tactile sensor arrays are composed of $4{\times}4$, $8{\times}8$ and $16{\times}16$ sensing elements connected with pluggable terminals connector, respectively. Especially, both the tactile sensor array and the pluggable terminals are formed in the sensor module during the fabrication process. The fabricated tactile sensor module is measured continuously in the normal force range of $0{\sim}1N$ with tactile sensor auto-evaluation system. The value of resistance is relatively increased linearly with normal force in the overall range. The variation rate of resistance is about 2.0%/N in the range of $0{\sim}0.6N$ and 1.5%/N in the range of $0.6{\sim}1N$. Also, the flexibility of the sensing module is adequate to be placed on any curved surface as cylinder because the matrix consists of polymer and metal thin film.

  • PDF

Solvent-Assisted Soft-Lithographic Patterning of Lyotropic Liquid Crystalline Polymer Film by Flow Control through Patterned Channels

  • Park, Chang-Sub;Park, Kyung-Woo;Kang, Shin-Won;Kwak, Gi-Seop;Kim, Hak-Rin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.641-644
    • /
    • 2009
  • We demonstrated a solvent-assisted soft-lithographic patterning method for producing patterned structure and patterned ordering with lyotropic liquid crystalline polymer (LCP) film. Experimental results showed that the liquid crystalline ordering of lyotropic film could be controlled by shearing effects of the fluidic solvent though the patterned mold channels. In this work, two types of lyotropic LCPs were used to investigate the effects of the alkyl chain length of the lyotropic LCP on producing liquid crystalline ordering through the solvent-assisted fluidic patterning.

  • PDF