• 제목/요약/키워드: Polyethylene-insulated Electric Wire

검색결과 9건 처리시간 0.021초

전기장이 인가된 상태에서 폴리에틸렌으로 피복된 기울어진 전선을 통해 전파하는 화염에 대한 실험적 연구 (Experimental Study on Spreading Flame over Slanted Polyethylene Insulated Electrical Wire with AC Electric Field)

  • 임승재;김민국;박정;정석호
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2014년도 제49회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.187-190
    • /
    • 2014
  • An experimental study on downwardly and upwardly spreading flames over slanted electrical wire, which is insulated by Polyethylene(PE), was conducted with applied AC electric field. The result showed that downwardly and upwardly spreading flames with angle of inclination leaned toward burnt side and unburned side, respectively. With applied AC electric fields, size of downwardly spreading flame decreased slightly and that of upwardly spreading flame increased significantly. Flame spread rate showed various trends in terms of inclination, applied voltage and frequency.

  • PDF

폴리에틸렌으로 피복된 전선을 통해 위로 전파하는 화염에 대한 교류전기장 효과에 대한 실험적 연구 (Experimental Study on Effect of AC Electric Field on Upwardly Spreading Flame over Polyethylene insulated Electrical Wire)

  • 임승재;김민국;박정;정석호
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2014년도 제49회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.363-365
    • /
    • 2014
  • An experimental study on effect of AC electric field on upwardly spreading flame over electrical wire, which is insulated by Polyethylene(PE), was conducted. The result showed that upwardly spreading flame leaned toward unburned side with angle of inclination. With applied electric field, size of upwardly spreading flame increased significantly. Flame spread rate showed various trends with inclination, applied voltage and frequency.

  • PDF

폴리에틸렌으로 피복된 전선화염의 전파에 교류전기장이 미치는 영향에 관한 실험적 연구 (Experimental Study on the Effects of AC Electric Fields on Flame Spreading over Polyethylene-insulated Electric-Wire)

  • 진영규;김민국;박정;정석호;김태형;박종호
    • 대한기계학회논문집B
    • /
    • 제34권11호
    • /
    • pp.1015-1025
    • /
    • 2010
  • 본 연구는 교류전기장이 인가된 전선에서의 화염전파특성에 전기장이 미치는 영향에 대한 실험적 연구이다. 폴리에틸렌으로 피복된 전선에서 인가된 교류전압과 주파수에 따라 화염전파율을 도출하였다. 그리고 화염전파는 선형적 화염 전파와 비선형적으로 가속된 화염 전파로 구분되어졌다. 이것은 전선에 인가된 교류전기장에 따라 형성된 전기장 세기의 축방향 분포가 원인이 된다. 그리고 기울어진 전선화염의 화염전파율이 상대적으로 높게 나타났다. 이러한 현상은 온도균형메커니즘으로 설명이 가능하다.

교류전기장이 인가된 폴리에틸렌으로 피복된 기울어진 전선을 통해 하향으로 전파하는 화염에 대한 실험적 연구 (Experimental Study on Downwardly Spreading Flame over Inclined Polyethylene-insulated Electrical Wire with Applied AC Electric Fields)

  • 임승재;박정;김민국;정석호
    • 한국연소학회지
    • /
    • 제19권4호
    • /
    • pp.1-7
    • /
    • 2014
  • An experimental study on downwardly spreading flame over slanted electrical wire, which is insulated by Polyethylene (PE), was conducted with applied AC electric fields. The result showed that the flame spread rate decreased initially with increase in inclination angle of wire and then became nearly constant. The flame shape was modified significantly with applied AC electric field due to the effect of ionic wind. Such a variation in flame spread rate could be explained by a thermal balance mechanism, depending on flame shape and slanted direction of flame. Extinction of the spreading flame was not related to angle of inclination, and was described well by a functional dependency upon the frequency and voltage at extinction.

교류전기장이 인가된 전선위에서 전선 끝단 근처의 화염전파 거동 (Flame Spread Behavior near the End of Wire over Electrical-wire with Applied AC Electric Fields.)

  • 황상석;김민국;박정;정석호;권오붕
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제44회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.249-252
    • /
    • 2012
  • Experiments have been conducted to clarify flame spread behavior over electrical wire near the end of wire with applied AC electric fields. It is seen that the flame spread behavior near the end of wire with applied AC electric fields are quite different from that in temporally linearly-increasing flame position. The flame spread behavior can be categorized into three regimes based on the relevance of flame shape and the slanted direction of spread flame to spread rate. Detailed explanations on the characteristics are made through thermal balance mechanism. Also, the effect of drop of molten PE and fuel vapor-jet in flame spread is also discussed.

  • PDF

대용량 XLPE 케이블 고찰 (Progress in Technology of Ultrahigh-voltage XLPE Cable)

  • 최창수;이갑중;권병일;남정세
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1356-1358
    • /
    • 1995
  • About 20 years have passed since cross-linked polyethylene(XLPE) came into practical use for power transmission cables. In 1969, We were the first to product 33kV XLPE insulated cables, and in 1984 produced XLPE cable for 154kV. To meet the increasing demand for electric power in large cities, and to improve reliability of the power supply, plans are being made to introduce ultrahigh-tension power cable for long distance underground lines in urban areas. Studies are currently under way to develop more than 154kV XLPE cables to meet increasing demand. In this paper presents the progress in the production and design of XLPE cables, and describes ways in which further improvements seems likely.

  • PDF

교류전기장이 인가된 전선을 통해 전파하는 화염에 있어서 기울어진 각도가 미치는 영향에 대한 실험적 연구 (Experimental Study on effect of inclination angle for Spreading Flame over Wire with AC Electric Fields)

  • 임승재;김민국;박정;권오붕;정석호
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2015년도 제51회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.185-188
    • /
    • 2015
  • An experimental study on downwardly and upwardly spreading flames over slanted electrical wire, which is insulated by Polyethylene(PE), was conducted with applied AC electric field. The result showed that downwardly and upwardly spreading flames with angle of inclination leaned toward burnt side and unburned side, respectively. With applied AC electric fields, size of downwardly spreading flame decreased slightly and that of upwardly spreading flame increased significantly. Flame spread rate showed various trends in terms of inclination, applied voltage and frequency.

  • PDF

교류전기장이 인가된 상태에서 전선을 통해 전파하는 화염에 대한 전선직경의 영향 (Effect of Diameter on Spreading Flame over Electrical Wire with Applied AC Electric Fields)

  • 박순호;임승재;권오붕;박정;정석호
    • 한국연소학회지
    • /
    • 제22권3호
    • /
    • pp.1-7
    • /
    • 2017
  • An experimental study on spreading flame over electrical wire, which was insulated by Polyethylene(PE) and had different diameters, was conducted with applied AC electric field. The result showed that the flame spread rate decreased in increase of the diameter of insulator at a fixed electric field. The flame spread rate exhibited increase or decrease tendency with applied AC electric field, having three distinct regimes depending on applied voltage and frequency. In each regime, the flame spread rate was characterized by physical parameters of applied electric fields and wire dimensions, and the behaviors could be explained by a thermal balance mechanism.

도체 수밀형 전력케이블의 가교잔사 가스에 의한 직선접속재 부풀음 현상 방지 대책 (The solution for preventing the expansion of cable joint caused by methane($CH_4$) gas to Water proof type of power cable)

  • 김종원;이기수;백흠수;최봉남;박희철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2020-2022
    • /
    • 2000
  • The cross-linked polyethylene(herein after XLPE) insulated power cable emit the methane($CH_4$)gas in the course of chemical cross-linking process. The general stranded conductor easily discharge this methane gas through the gap of each stranded wires. But the special stranded conductor that filled with semi-conducting rubber compound to prevent water penetration which is applied to water proof type of cable(22.9kV CN/CV-W), disturb the methane gas emission. The pre-mold type cable joint shall be expanded gradually by emit of gas left in XLPE insulation. For example, sometimes the corona problem outbreak on a new power distribution line, resulted from the gap between the sleeve and semi-conductive layer of cable joint. If above mentioned problem especially happened on the way of operating. We have to shut down the line and try to discharge the methane gas in cable joint. In this point, we would like to explain the mechanism of methane gas & cable joint and our test result briefly. At last, we are pleased to introduce the solution for preventing reoccurrence of this problem.

  • PDF