Flame Spread Behavior near the End of Wire over Electrical-wire with Applied AC Electric Fields.

교류전기장이 인가된 전선위에서 전선 끝단 근처의 화염전파 거동

  • Published : 2012.04.13

Abstract

Experiments have been conducted to clarify flame spread behavior over electrical wire near the end of wire with applied AC electric fields. It is seen that the flame spread behavior near the end of wire with applied AC electric fields are quite different from that in temporally linearly-increasing flame position. The flame spread behavior can be categorized into three regimes based on the relevance of flame shape and the slanted direction of spread flame to spread rate. Detailed explanations on the characteristics are made through thermal balance mechanism. Also, the effect of drop of molten PE and fuel vapor-jet in flame spread is also discussed.