• Title/Summary/Keyword: Polyethylene liner

Search Result 25, Processing Time 0.034 seconds

A Dielectric Characteristics of Linear Low Density Polyethylene and Ethylene Vinyl Acetate (Hot Press를 이용한 선형저밀도 플리에틸렌과 비닐아세테이트의 유전 특성)

  • 조경순;오세영;이종필;홍능표;이용우
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.556-559
    • /
    • 1999
  • In order to investigate the influence on dielectric characteristic due to physical structural change of specimens, we investigated the frequency and temperature dependency of tan $\delta$ for virgin specimen and mixtured specimens in the temperature range of 25[$^{\circ}C$] ~ 120[$^{\circ}C$], frequency range of 300(mv) ~ 1500[mV] An experimenatal specimen is selected as Low Liner Density Polyethylene (LLDPE) and Ethylene Vinyl Acetate(EVA) (thickness 200[$\mu$m]) produced by mixture ratio of 50:50, 60:40, 70:30 and 80:20. From the results of XRD it can be confirmed that the peak of LLDPE and EVA made by mixture ratio of 70:30 at 2$\theta$= 21.4$^{\circ}$is higher and the peak made by amorphous contribution at 2$\theta$= 19.5[$^{\circ}$] is almostly constant without no concern.

  • PDF

Pseudotumor and Subsequent Implant Loosening as a Complication of Revision Total Hip Arthroplasty with Ceramic-on-Metal Bearing: A Case Report

  • Naik, Lokesh Gudda;Shon, Won Yong;Clarke, I.C.;Moon, Jun-Gyu;Mukund, Piyush;Kim, Sang-Min
    • Hip & pelvis
    • /
    • v.30 no.4
    • /
    • pp.276-281
    • /
    • 2018
  • Pseudotumors are not uncommon complications after total hip arthroplasty (THA) and may occur due to differences in bearing surfaces of the head and the liner ranging from soft to hard articulation. The most common causes of pseudotumors are foreign-body reaction, hypersensitivity and wear debris. The spectrum of pseudotumor presentation following THA varies greatly-from completely asymptomatic to clear implant failure. We report a case of pseudo-tumor formation with acetabular cup aseptic loosening after revision ceramic-on-metal hip arthroplasty. The patient described herein underwent pseudotumor excision and re-revision complex arthroplasty using a trabecular metal shell and buttress with ceramic-on-polyethylene THA. Surgeons should be aware of the possibility of a pseudotumor when dealing with revisions to help prevent rapid progression of cup loosening and implant failure, and should intervene early to avoid complex arthroplasty procedures.

인공관절의 수명 향상을 위해 Plasma Immersion Ion Implantation & Deposition 공정으로 증착된 NbN 박막에 대한 UHMWPE Liner 소재의 마모량 평가

  • Park, Won-Ung;Kim, Eun-Gyeom;Jeon, Jun-Hong;Choe, Jin-Yeong;Mun, Seon-U;Im, Sang-Ho;Han, Seung-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.137-137
    • /
    • 2012
  • 인공관절은 노인성 질환이나 자가 면역질환, 신체적인 외상 등으로 인하여 발생하는 관절의 손상 부위를 대체하기 위하여 고안된 관절의 인공 대용물이다. 인공 관절 중 인공 고관절의 경우 라이너(Liner)와 헤드(Head) 부분이 직접적인 마모 운동을 수행하게 되므로, 이 부분의 소재 특성에 따라 인공관절의 수명이 결정 되게 된다. 현재 헤드 소재로서는 Co-Cr-Mo 합금이, 라이너 소재로서는 고분자 소재인 UHMWPE (Ultra High Molecular Weight Polyethylene)가 주로 사용되고 있다. 이러한 MOP (Metal-On-Polymer) 구조의 인공관절의 경우, 충격흡수의 장점이 있는 반면, 관절 운동시 발생하는 UHMWPE 의wear debris에 의해 골용해가 발생하게 되어 인공관절의 수명이 저하되는 문제점이 있으며, 금속 헤드의 마모로 인한 금속이온의 용출은 세포 독성의 문제를 야기하여 인공관절의 수명을 저하시키는 또 다른 원인이 되고 있다. 따라서 본 연구에서는 PIII&D (Plasma Immersion Ion Implantation & Deposition) 공정을 이용하여 금속 (Co-Cr-Mo 합금)소재 위에 세라믹 (niobium nitride) 박막을 증착하여 상대재인 UHMWPE의 마모를 줄이고자 하는 연구를 진행하였다. 금속 소재 위에 증착된 세라믹 박막은 상대재인 UHMWPE의 마모량을 줄여줄 뿐만 아니라 금속이온의 용출을 막아준다는 장점이 있으나, 장시간의 마모 운동에 의하여 발생하는 박막의 박리 현상은 인공관절의 수명을 급격히 저하시키는 또 다른 원인이 된다. 이러한 단점을 해결하기 위하여, 박막의 증착 초기에 이온주입과 증착을 동시에 수행하는 dynamic ion mixing공정을 수행하였다. Dynamic ion mixing 공정을 수행함에 따라 박막과 금속 사이의 접착력이 증가하게 되어, UHMWPE의 마모량이 2배 가까이 감소하는 것을 확인할 수 있었으며, 장시간의 마모시험에서도 우수한 결과를 얻을 수 있었다. 또한 UHMWPE의 마모량을 감소시키기 위하여 박막을 증착하기 전에 금속 소재에 질소 이온주입을 수행하는 pre-ion implantation 공정을 도입하였다. 질소 이온주입 결과 Co-Cr-Mo 합금 표면에 부분적으로 CrN, Cr2N의 세라믹 상이 형성 되는 것을 확인할 수 있었으며, 그에 따라 UHMWPE의 마모량이 2배 이상 감소 되는 것을 확인 할 수 있었다.

  • PDF

Ceramic-Ceramic Wear Zirconia/Alumina Composites For The Application Of Total Hip Joint Implant (인공 고관절 골두용 세라믹 복합재료에 대한 세라믹-세라믹 접촉 마멸 특성 분석)

  • Kim H.;Lee K.Y.;Kim D. J.;Lee M. H.;Seo W. S.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.355-361
    • /
    • 2004
  • Ceramic femoral heads in the total hip replacement have been developed to reduce the polyethylene liner wear, Alumina and zirconia (3Y-TZP) having the excellent tribological properties are coupled against acetabular cups of polyethylene and are used in clinical application worldwide. However, alumina has a risk of catastrophic failure, and zirconia has the low temperature degradation in spite of enhanced fracture toughness. Recently, novel zirconia/alumina composite is very attractive due to the low temperature degradation (LTD)-free character and high fracture toughness. In the present study, we focus on the wear of ceramic on ceramic, which are able to be used as femoral heads and acetabular cups. Therefore, LTD-free zirconia/alumina composites with three compositions are made in a form of disk and cylinder, and the wear of the composites is performed on pin-on-disk type wear tester. The wear is conducted with or without lubricant. All the composites fabricated with the different composition show the good wear resistance.

  • PDF

Effects of film liners, ethylene scrubber, alcohol releaser and chlorine dioxide on the berry quality during simulated marketing in 'Campbell Early' grapes

  • Kim, Sung-Joo;Choi, Cheol;Ahn, Young-Jik;Lim, Byung-Sun;Chun, Jong-Pil
    • Korean Journal of Agricultural Science
    • /
    • v.47 no.3
    • /
    • pp.415-424
    • /
    • 2020
  • This study investigated the effects of an ethylene scrubber (ES) with a micro-perforated polypropylene (MP-PP, 30 ㎛) or a high density polyethylene (MP-HDPE, 30 ㎛) film liner for the export carton packaging box in 'Campbell Early' grapes. Rachis browning was highest in the untreated group, followed by MP-PP and MP-HDPE for 14 days of simulated marketing at 20℃. The combination treatment of ES with the film liners showed a partial inhibition of the rachis browning regardless of the film liners. The effects of an alcohol releaser (AR) sachet or chlorine dioxide (CD) diffuser co-packaging were also investigated in the 'Campbell Early' grapes packed with the MP-HDPE (40 × 99 pin hole·m-2) film liner. The CD 1 g treatment showed a very limited weight loss of 1.1%, which was significantly lower than the 4.7% of the untreated control after 14 days of simulation marketing at 20℃. The berry shatter was 0.7% for the MP-HDPE + CD 1 g treatment and 1.8% for the MP-HDPE + CD 5 g treatment on the 10th day of the simulated marketing, which was significantly lower than the 8.9% of the control. The stem browning was significant suppressed until the 10th day of the simulated marketing. In particular, the CD 1 g treatment in combination with the MP-HDPE showed a low rachis and pedicel browning index of 2.0, which is 50% and 40% lower than that of the untreated control and the MP-HDPE single treatment, respectively. In addition, the CD 1 g treatment group showed a higher decay reduction effect than the CD 5 g treatment group, which caused high concentration damage.

The Effects of HDPE by Landfill Settlements in the Final Cover System (침하에 의한 폐기물 매립지 최종복토층 HDPE의 영향에 관한 연구)

  • Moon, Chul-Hwan;Lee, Jai-Young;Jeon, Han-Yong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.2 no.3
    • /
    • pp.11-18
    • /
    • 2003
  • The one of the most important concerns in the design of the final cover system is to restrict percolation of water into the waste body. To minimize entering the water, the final cover system has the barrier layer that consists of a single compacted clay liner(CCL) or a composite liner with high density polyethylene(HDPE) overlying CCL. The HDPE as well as CCL can be damaged by landfill settlements. Therefore, this study was conducted to assess the effects of HDPE induced by settlements in the final cover system after closure. The results of the three test that is field test, lysimeter test in laboratory, and prediction of settlement represent that the HDPE in the final cover system is not pretty much affected by settlements and stable on settlements.

  • PDF

Effect of Heat Treatment on Mechanical Properties of Cross-Linked Ultra-High Molecular Weight Polyethylene Used for Artificial Joint Liner (인공관절 라이너용 가교된 초고분자량폴리에틸렌(UHMWPE)의 열처리 조건에 따른 기계적 특성 변화)

  • Kim, Hyun-Mook;Kim, Dong-Hoon;Gu, Ja-Uk;Choi, Nak-Sam;Kim, Sung-Kon
    • Composites Research
    • /
    • v.22 no.2
    • /
    • pp.1-6
    • /
    • 2009
  • The mechanical characteristics of gamma-ray irradiated UHMWPE specimens were investigated under various heat treatment conditions. The heat treatment was performed in the range of annealing and remelting temperatures. The annealing treatment below the temperature of $130^{\circ}C$ hardly induced changes in the tensile strength, the strain at the failure and the hardness. However the remelting treatment above $140^{\circ}C$ deteriorated those mechanical properties. It was shown in an FTIR analysis that the annealing treatment caused some oxidation of free radicals created by the pretreatment of the irradiation. These quantitative data represented by the behavior of mechanical properties might be used as basic informations for the design and analysis of various artificial joints.

Effects of harvest times with polyethylene (PE) film liner, 1-methylcyclopropene (1-MCP) and aminoethoxyvinylglycine (AVG) treatments on fruit quality in 'Sangjudungsi' persimmon during cold storage (수확시기에 따른 수확 후 PE필름, 1-MCP 및 AVG 처리가 '상주둥시' 감과실의 저온저장동안 과실품질에 미치는 영향)

  • Win, Nay Myo;Yoo, Jingi;Ryu, Seulgi;Lee, Jinwook;Jung, Hee-Young;Choung, Myoung-Gun;Park, Kyeung-il;Cho, Young-Je;Kang, Sang-Jae;Kang, In-Kyu
    • Food Science and Preservation
    • /
    • v.24 no.7
    • /
    • pp.898-907
    • /
    • 2017
  • This study was aimed to test harvest time effect with polyethylene (PE) film liner, 1-methylcyclopropene (1-MCP) and aminoethoxyvinylglycine (AVG) treatments on fruit quality attributes in 'Sangjudungsi' persimmon fruit during cold storage. The fruits were harvested 10 days earlier in 2016 than the mature harvest time in 2015. The ethylene production was significantly lower in early harvested fruits than in mature harvested ones. Flesh firmness was maintained higher in 1-MCP treated fruit than in other treatments during cold storage. The rate of fruit weight loss was significantly inhibited by PE film liner treatment during storage, regardless of harvest time. 1-MCP treatment showed less change in fruit peel color variables ($L^*$ and $b^*$) from the calyx-end and equatorial regions during cold storage, compared with those from the control and PE film treatments. The incidence rate of fruit decay and softening was higher in PE film treated fruits than in the other treatments. However, there was no decay detected in AVG treated fruit. The early harvested fruits were maintained higher flesh firmness, compared with mature harvested fruits. Nevertheless, the mature harvested fruits showed much higher soluble solids content, the redness (Hunter a value) of the fruit peel and respiration rate, compared with early harvested fruits. Furthermore, the rate of weight loss in the fruit was remarkably inhibited in the PE film treatment.

Preparation of Heterogeneous Ion Exchange Membranes and Evaluation of Desalination Performance in Capacitive Deionization (불균질 이온교환막의 제조와 축전식 탈염에서의 탈염 성능 평가)

  • Choi, Jae-Hwan;Lee, Joo-Bong
    • Membrane Journal
    • /
    • v.26 no.3
    • /
    • pp.229-237
    • /
    • 2016
  • We prepared heterogeneous ion exchange membranes (hetero-IEMs) for the application of membrane capacitive deionization (MCDI). Hetero-IEMs were fabricated by compressing the mixture of ion exchange resin powders and liner low density polyethylene (LLDPE). Characterization and MCDI desalination experiments were carried for the fabricated membranes. Electrical resistance of membrane decreased and water content increased with increasing the resin content in the hetero-IEMs. However, transport number indicating permselectivity of membrane was similar with that of commercial homogenesous ion exchange membrane. The results of MCDI desalination experiments showed that the adsorption amount for hetero-IEM was about 90% of that of homogeneous membrane due to the high electrical resistance of hetero-IEM. Although desalination performance of hetero-IEM decreased compared with homogeneous membrane, it was thought to be applicable to MCDI because of simple preparation and low price.

A Study on Design of Type IV Hydrogen Pressure Vessels with Filament Winding Method (필라멘트 와인딩 공법을 적용한 타입 IV 수소 압력용기 설계 연구)

  • Sungjin Ahn;Hyunbum Park
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.6
    • /
    • pp.127-132
    • /
    • 2023
  • In this study, designing of a Type 4 pressure vessel using the filament winding method was conducted. In order to prevent leakage in consideration of the design of the hydrogen storage tank, a liner was designed by applying high-density polyethylene (HDPE), and the composite structure was designed by stacking carbon/epoxy in the hoop and helical directions. As a theoretical approach, the angle of the helical fiber and fiber thickness of each hoop and helix were designed. The safety of the design was verified using the commercial software ANSYS.